Caen A3484, A3484S, A3584, A3485S Technical Information Manual

Technical
Information
Manual
4 July 2017
Revision n. 3
NPO:
00120/04:A348x.MUTx/03
CAEN will repair or replace any product within the guarantee period if the Guarantor declares that the product is defective due to workmanship or materials and has not been caused by mishandling, negligence on behalf of the User, accident or any abnormal conditions or operations.
CAEN declines all responsibility for damages or injuries caused by an improper use of the Modules due to negligence on behalf of the User. It is strongly recommended to read thoroughly the CAEN User's Manual before any kind of operation.
CAEN reserves the right to change partially or entirely the contents of this Manual at any time and without giving any notice.
Disposal of the Product
The product must never be dumped in the Municipal Waste. Please check your local regulations for disposal of electronics products.
Document type:
Title:
Revision date:
Revision:
User's Manual (MUT)
A3484-A3485 AC/DC Converter 400 V 3-phase 48 V 2.5/5kW
04/07/2017
3
NPO:
Filename:
Number of pages:
Page:
00120/04:A348x.MUTx/03
A3485_REV3.DOC
21
3
TABLE OF CONTENTS
1. EASY EMBEDDED ASSEMBLY SYSTEM .............................................................................................. 5
1.1 FUNCTIONAL DESCRIPTION ....................................................................................................................... 5
1.2 THE CAEN MULTICHANNEL POWER SUPPLY SYSTEM OVERVIEW ........................................................... 6
1.3 THE MOD. A1676A BRANCH CONTROLLER OVERVIEW............................................................................ 8
2. MOD. A3484 AND A3485 AC/DC CONVERTERS ................................................................................... 9
2.1 FRONT PANEL COMPONENTS ................................................................................................................... 10
2.1.1 OUTPUT± ..................................................................................................................................................... 10
2.1.2 Power/Monitor .............................................................................................................................................. 10
2.1.3 EASY BUS ...................................................................................................................................................... 11
2.1.4 Interlock ......................................................................................................................................................... 11
2.1.5 48V IN............................................................................................................................................................ 12
3. SAFETY INFORMATION AND INSTALLATION REQUIREMENTS .............................................. 13
3.1 GENERAL SAFETY INFORMATION ............................................................................................................ 13
3.1.1 Injury Precautions ......................................................................................................................................... 13
3.2 SAFETY TERMS AND SYMBOLS ON THE PRODUCT .................................................................................. 13
3.3 INSTALLATION ........................................................................................................................................ 14
4. OPERATING MODES ............................................................................................................................... 15
4.1 OUTPUT CONTROL AND MONITORING ...................................................................................................... 15
4.1.1 Internal Channel OPC Items ......................................................................................................................... 17
4.1.2 Output Channel OPC Items ........................................................................................................................... 18
LIST OF FIGURES
FIG. 1.1 SYSTEMS BLOCK DIAGRAM ...................................................................................................................... 6
FIG. 2.1 MOD. A348X FRONT PANEL ..................................................................................................................... 9
FIG. 2.2 OUTPUT± SECTION ............................................................................................................................... 10
FIG. 2.3 OUTPUT± SECTION ............................................................................................................................... 10
FIG. 2.4 EASY BUS SECTION .............................................................................................................................. 11
FIG. 2.5 INTERLOCK SECTION ............................................................................................................................... 11
FIG. 2.6 INTERLOCK DIAGRAM ............................................................................................................................. 12
FIG. 2.7 48V IN SECTION ..................................................................................................................................... 12
FIG. 2.8 A3484/A3485 GROUND SCHEMES .......................................................................................................... 12
Document type:
Title:
Revision date:
Revision:
User's Manual (MUT)
A3484-A3485 AC/DC Converter 400 V 3-phase 48 V 2.5/5kW
04/07/2017
3
NPO:
Filename:
Number of pages:
Page:
00120/04:A348x.MUTx/03
A3485_REV3.DOC
21
4
LIST OF TABLES
TABLE 1.1 TECHNICAL SPECIFICATIONS OF THE SY 1527 MAINFRAME .................................................................. 7
TABLE 2.1 TECHNICAL SPECIFICATIONS OF THE A3484 AND A3485 48 V POWER SOURCES .................................. 9
TABLE 4.1 CH0 PARAMETERS (BOARD PARAMETERS) ........................................................................................ 15
TABLE 4.2 CH1..2 PARAMETERS (OUTPUT CHANNEL PARAMETERS) ................................................................... 16
TABLE 4.3 STATUS WORD SIGNIFICANT BITS ........................................................................................................ 16
TABLE 4.4 INTERNAL CHANNEL ITEMS ................................................................................................................ 18
TABLE 4.5 OUTPUT CHANNEL ITEMS ................................................................................................................... 20
Document type:
Title:
Revision date:
Revision:
User's Manual (MUT)
A3484-A3485 AC/DC Converter 400 V 3-phase 48 V 2.5/5kW
04/07/2017
3
NPO:
Filename:
Number of pages:
Page:
00120/04:A348x.MUTx/03
A3485_REV3.DOC
21
5
1. EASY Embedded Assembly System
1.1 Functional description
EASY (Embedded Assembly SYstem) is the new CAEN power supply solution for
operation in magnetic field and radioactive environment. CAEN has been involved for
more than a decade in developing different solutions for the main LHC experiments, where the electronic equipment of the experiment is dealing with high dose radiation and
intense magnetic field. In order to provide safe and reliable operations in such hostile
areas, CAEN started tests with rad-tolerant components and magnetic field resistant solutions, patenting the new technology that is now used in this new line of products. Moreover, though designed for harsh environment, the EASY modules can work also in normal condition with excellent performance. In the new architecture, the power supply can be located directly in the hostile area, where the EASY modules provide a wide variety of output voltages to satisfy the requirements of most detectors and front-end electronics. The control of the EASY power supply system is done remotely using a Branch Controller (Mod. A1676A) plugged in a SY1527 or SY2527 mainframe located in the control room. Each A1676A branch controller can handle up to 6 EASY crates: in this way, one SY1527 power supply system, for example, housing up to 16 A1676A boards, can handle up to 96 EASY systems. The EASY crate can house up to 10 boards,
depending on the boards’ width. The branch controller is the interface between the
mainframe (SY1527 or SY2527) and the remote boards in the EASY crate: its role is to configure the EASY channels as if they belong to the supply unit slot in which the branch controller is located. All the channels of the EASY boards will be considered as channels of the branch control board, thus hugely increasing the number of channels the system can handle. Through the mainframe, the provided and fully reliable OPC server permits
an immediate and “automatic” interfacing with the custom control software; moreover, a
C-library for Windows and Linux is available as well. The EASY crate can be used with an air and/or water intercooler and its standard width fit the rack mounting. Fig. 1.1 shows the system’s block diagram.
Document type:
Title:
Revision date:
Revision:
User's Manual (MUT)
A3484-A3485 AC/DC Converter 400 V 3-phase 48 V 2.5/5kW
04/07/2017
3
NPO:
Filename:
Number of pages:
Page:
00120/04:A348x.MUTx/03
A3485_REV3.DOC
21
6
Fig. 1.1 – System’s block diagram
1.2 The CAEN Multichannel Power Supply System Overview
The SY1527 system is the fully equipped experiment version of a new line of power supply systems which represent CAEN's latest proposal in the matter of High Voltage and Low Voltage Power Supplying. This system outlines a completely new approach to power generation and distribution by allowing the housing, in the same mainframe, of a wide range of boards with different functions, such as High/Low Voltage boards, generic I/O boards (temperature, pressure monitors, etc.) and branch controllers, where the latter are used to control other remote generators and distributors. Modularity, flexibility and reliability are the key-points of its design, enabling this module to meet the requirements needed in a wide range of experimental conditions, which range from those of LHC experiments, where the features of this model find prior application, to those of other less challenging, but still demanding, High Energy Physics experiments. The mainframe is housed in a 19"-wide, 8U-high euro-mechanics rack and hosts four main sections:
- the Board Section, with 16 slots to house boards, distributors and branch controllers;
- the Fan Tray Section, housing 6 fans arranged on two rows;
- the Power Supply Section, which consists of the primary power supply and up to 3
power supply units;
- the CPU and Front Panel Section which includes all interface facilities. The User Software Interface features the usual friendliness of the previous CAEN systems which now also includes a 7.7" colour LCD. A wide choice of interface facilities provides full communication compatibility with the previous systems and the feasibility of controlling heterogeneous external devices. Modularity has been one of the leading criteria in the design and development of the system: both the Power Supply Section and the Board Section are completely modular. The Power Supply Section allows different configurations with up to 3 power supply units per mainframe (up to 2250 W), while the Board Section can house up to 16 boards able to fulfil different functions. A complete line of power supply boards and distributors has been specially developed for this new system. The minimum system configuration consists of the primary power supply, one
Document type:
Title:
Revision date:
Revision:
User's Manual (MUT)
A3484-A3485 AC/DC Converter 400 V 3-phase 48 V 2.5/5kW
04/07/2017
3
NPO:
Filename:
Number of pages:
Page:
00120/04:A348x.MUTx/03
A3485_REV3.DOC
21
7
Power Supply Unit and one board. The system allows also to deal with power supply
solutions composed by “branch controllers” (housed in the system main frame) and on-
detector “remote boards” (manufactured in order to be magnetic field and radiation
tolerant). Channel trip control on other crates is performed via four external differential trip lines. A sophisticated trip handling via software allows to control and correlate trip conditions on the channels of the crate as well as of other crates connected to it. Live insertion and extraction of the boards, which reduces the down time of the global system, and easy access to the computing core and peripherals of the system complete the system flexibility. Easy interfacing is another key-point of the SY1527 system, which can be connected to SY127 and SY527 systems. The Ethernet interface (TCP/IP) allows both an easy Telnet access and the connection via OPC Server to a SCADA control system. Enhanced software programming features a unified command set independent from the interface used to communicate with the system. The Power Supply Section and Board Section can be externally synchronised via front panel connectors. Multi-layered access to the system via Intranet is foreseen through the management of several custom user profiles. In particular, three different access levels have been implemented: Guest, User and Administrator, each of which with password protection. Handy maintenance and upgrading, which constitute a major issue in the reliability of a system, are further guaranteed by the possibility of accessing and servicing the system via network facilities. Actually, the Telnet access facility allows remote debugging and technical support of the system, including future firmware upgrading. For a detailed description of the SY 1527 Universal Multichannel Power Supply System please refer to the SY 1527 User's Manual.
Table 1.1 Technical specifications of the SY 1527 mainframe
Packaging
- 19"-wide, 8U-high Euro-mechanics rack;
- Depth: 720 mm.
Weight
-Mainframe (*): 24 kg
-Mod. A1532: 3.2 kg
Power requirements
Voltage range: 100/230 V Frequency: 50/60 Hz Power: 3400 W
Max. number of boards per crate
16
Max. nr. of power supply units per crate
3
Primary power supply output (Mod. A 1531)
12 V, 8 A
+5 V, 20 A
Power supply unit output (Mod. A 1532)
+48 V, 15.6 A
Max. output power
2250 W
Operating temperature
From 0°C (dry atmosphere) to +40°C
Storage temperature
From -20°C (dry atmosphere) to +50°C
(*) One Primary Power Supply (Mod. A 1531) and one Power Supply Unit (Mod. A 1532) are included; boards are not included.
Loading...