CADDX NX-4 SCHEMATICS

Page 1
SECURITY SYSTEM NOTES
Installing/Service Company _________________________________ For Service Call __________________________________________ Central Station ___________________________________________
Duress Code ____________________
FUNCTION CODES
Function Code Controls Function
Fire Auxiliary Emergency Police
PROGRAMMED FUNCTIONS
 Abort Delay (V)  Cancel Alarm  Group Bypass (V)  Auto Bypass (V)  Chime  Quick Arm (V)  Auto Instant  Communicator Test  Re Exit  Battery Test  Forced Arming (V)  Siren Test
(V) These features should not be enabled on UL listed systems.
ENTRY / EXIT DELAY TIMES
Exit Delay Time __________ Secondary Exit Delay Time ________ Entry Delay Time _________ Secondary Entry Delay Time _______
ZONE DESCRIPTIONS
01 _______________________ 05 ________________________ 02 _______________________ 06 ________________________ 03 _______________________ 07 ________________________ 04 ________________________ 08 ________________________
Installer: Mark wireless zones with an “X”
1
as required by UL.
Page 2
THIS MANUAL IS FURNISHED TO HELP YOU UNDERSTAND YOUR SECURITY SYSTEM AND BECOME PROFICIENT IN ITS OPERATION. ALL USERS OF YOUR SECURITY SYSTEM SHOULD READ AND FOLLOW THE INSTRUCTIONS AND PRECAUTIONS IN THIS BOOKLET. FAILURE TO DO SO COULD RESULT IN THE SECURITY SYSTEM NOT WORKING PROPERLY. THIS BOOKLET SHOULD BE KEPT IN AN ACCESSIBLE LOCATION FOR THE LIFE OF THE SECURITY SYSTEM. IF YOU DO NOT UNDERSTAND ANY PART OF THIS MANUAL YOU SHOULD NOTIFY YOUR INSTALLING COMPANY.
The SECURITY CONTROL can be turned on (ARMED) and off (DISARMED) by entering a 4 or 6 digit code into the Keypad Control, which is similar to a telephone keypad. If your Security Control has been so programmed, you may be able to turn on (ARM) your System by simply pressing the [STAY] or [EXIT] key. The system must always be disarmed using a 4 or 6 digit code. The LED keypad includes up to 35 lights and a built-in electronic sounder. These provide specific information relating to the status of the security system which is described in the booklet. Understanding what the lights and sounds mean will help you to easily operate your system.
READ THE ENTIRE MANUAL AND, IF POSSIBLE, PRACTICE ON THE KEYPAD CONTROL WHILE YOUR PROFESSIONAL INSTALLER IS ON SITE.
KEEP IN MIND, THE LEVEL OF SECURITY YOU WILL OBTAIN WITH THIS SYSTEM RELATES SPECIFICALLY WITH TWO MAJOR FACTORS:
1. The quantity, quality, and placement of security devices attached to this system.
2. The knowledge you have of the security system and how that knowledge is utilized in a weekly test of the complete system.
YOU SHOULD BE AWARE OF THE FOLLOWING FACTS WHEN PREPARING A SAFETY/SECURITY PLAN FOR YOUR HOME/BUSINESS.
Your security system is an electronic device and is subject to failure or
malfunction. Do not rely on it as your single source of security.
Your system should be tested weekly.  Your system will not work without power.  Warning devices will need to be loud enough, wired correctly, and properly
placed to provide notification of an alarm event.
Smoke and heat detectors may not detect heat and smoke in all situations.  Use qualified security professionals to install and maintain your security system.  It may be possible to arm the security system without the backup battery
connected. Your periodic test should be done with A.C. Power removed to verify the battery is connected and adequately charged.
Care should be taken to plug in and restrain the A.C. Transformer after testing.
PLEASE READ THE FOLLOWING INFORMATION AND INSTRUCTIONS CAREFULLY BEFORE OPERATING YOUR SECURITY CONTROL SYSTEM. IF YOU DO NOT UNDERSTAND ANY PORTION OF THIS MANUAL, OR IF YOU HAVE ANY QUESTIONS ABOUT YOUR SYSTEM, CONTACT THE INSTALLING COMPANY LISTED ON PAGE 1 OF THIS BOOKLET.
2
Page 3
TABLE OF CONTENTS
GLOSSARY OF TERMS..........................................................................4
UNDERSTANDING THE LIGHTS............................................................5
Armed Light ....................................................................................................5
Bypass Light...................................................................................................5
Cancel Light....................................................................................................5
Chime Light.....................................................................................................5
Exit Light.........................................................................................................5
Fire Light.........................................................................................................5
Instant Light....................................................................................................5
Power Light.....................................................................................................5
Ready Light.....................................................................................................6
Stay Light........................................................................................................6
Zone Light.......................................................................................................6
EMERGENCY ACTIVATION KEYS.........................................................6
KEYPAD FUNCTIONS.............................................................................7
Arming Your System In The “Away” Mode .....................................................7
Arming Your System In The “Stay” Mode.......................................................7
Using The Quick Arm......................................................................................8
Disarming Your System..................................................................................9
Cancel / Abort Feature ...................................................................................9
Bypassing Zones............................................................................................9
Group Bypass.................................................................................................9
Unbypassing.................................................................................................10
Turning The Door Chime On And Off...........................................................10
CHANGING USER CODES ...................................................................10
ASSIGNING USER CODE AUTHORITY LEVELS................................11
OTHER KEYPAD FUNCTIONS.............................................................12
Setting The Keypad Tone.............................................................................12
View Alarm Memory......................................................................................12
Test Function................................................................................................12
Reset Function..............................................................................................12
Setting The System Date..............................................................................13
Setting The System Clock ............................................................................13
KEYPAD CONTROL TONES (BEEPS).................................................14
SERVICE MENU ....................................................................................15
EMERGENCY EVACUATION PLANS...................................................16
3
Page 4
GLOSSARY OF TERMS
Abort Delay Authority Level
panel.
Central Station:
Chime Feature:
whenever an entry/exit door is opened.
Codes:
toggle switch to turn specific functions on/off). NOTE: A system may have either 8 four (4) digit codes or 8 six (6) digit codes, but not a mixture of the two.
Duress Code:
station that indicates the alarm system is being operated under duress.
Forced Arming:
one or more zones open. A system that is ready to be “force armed” will flash the
ready light
Function Code:
been programmed by the installer to operate a device.
Group Bypass:
single operation.
Instant/Delay:
doors, or grants a delay to allow someone to enter/exit the building without an alarm, or before entering a user code to disarm.
: An option that allows a delay in reporting to the central station.
: The level of access an individual has when using an alarm
Location where alarm data is sent during an alarm report An option that allows the keypad to sound a ding-dong
Can be either User Codes (relating to a person) or Function Codes (a
An option that allows a special code to be sent to the central
An option that allows the system to be turned on (ARMED) with
. (Note: Those zones that are not ready will not create an alarm.)
A Function Code is either a four (4) or six (6) digit code that has
An option that allows the user to bypass multiple zones with a
An option that allows an instant alarm condition for Entry/Exit
.
Master Code: Perimeter: Quick Arm:
pressing either the [ only) as programmed by the installing company.
User Code:
A master arm/disarm code that can program other user codes.
The outer edge of the protected area.
An option that allows you to turn on (ARM) the security system by
] or [
STAY
A four (4) or six (6) digit entry used to arm or disarm the system.
] key on the keypad control (for ARMING
EXIT
4
Page 5
UNDERSTANDING THE LIGHTS
Armed Light
The
armed light
when it is disarmed. The during the previous arm cycle.
Bypass Light
The
bypass light
bypassed will also be illuminated. If the bypassed.
Cancel Light
The
cancel light
followed by the [ will stop the communication process.
enabled
alarm report to the central station will cause the stay on until the central station has received the cancel report.
cancel feature must be enabled.
Chime Light
The c
Exit Light
The during the last 10 seconds of the exit delay as a warning that the time is running out. (The user may want to disarm the system if the flashing in order to prevent an alarm. The user may then re-arm the system and exit before the delay expires.)
Fire Light
A steady
light
Instant Light
The
time the of an entry/exit door will produce an immediate alarm
be toggled on or off by pressing the [ When the
Power Light
The system has a low battery condition.
. Entering a code followed by the [
hime light
exit light
means that a fire zone is in a trouble condition.
instant light
power light
is “on” when the system is armed. The
armed light
is “on” when any zone is bypassed. The zone(s) that is
will flash when there has been an alarm
bypass light
will flash during an abort delay time. If a code is entered
CANCEL
] key while this light is flashing, all abortable reports
Note: The abort feature must be
CANCEL
cancel light
is “on” when the chime feature is “on”; “off” otherwise.
is “on” during the exit delay. Please note that the light will flash
armed light
is “off”, no zones are
] key during or after an
to come on. It will
exit light
fire light
instant light
instant light
means a fire zone has been faulted. A rapidly flashing
is “on” when there is no delay on your entry/exit door(s).
is “on” and the exit delay has expired, the opening
. The
instant light
] key while the system is armed.
Stay
is “off”, the entry/exit door(s) is delayed.
is on if the primary power is on. The
power light
will flash if the
is “off”
Note: The
is
fire
Any
can
5
Page 6
Ready Light
The
ready light
force arm. The of a zone(s) being faulted.
Stay Light
The
stay light
bypassed.
Zone Light
The
zone lights
the zone has been bypassed. If a or has been faulted. If a in a trouble condition. Trouble conditions are:
Tamper
(A combination of Alarm/Fault and Tamper/Trouble will produce a rapid “flashing” light for a short period of time, followed by a slow “flashing” light.)
is “on” when the system is ready to arm and “flashes” if ready to
ready light
is “on” when the all interior (motion detector) zones are
are “off” when everything is normal. A
is off when the system is not ready to arm because
zone light
zone light
Hardware
zone light
is “flashing” rapidly, it means that the zone is
Low Battery
is “flashing”, that zone is in alarm
Loss of Supervision
will be “on” if
EMERGENCY ACTIVATION KEYS
NOTES: You must press and hold these keys for 2 seconds to activate these functions. Your system may not be programmed for these activation keys (see page 1)
that requires response by emergency personnel. If your system is programmed for these functions, the following reports can be sent.
Fire Key – This key can activate the fire alarm when pressed for two seconds. If your system is connected to a monitoring center, an emergency report could be sent to that center.
Auxiliary Emergency Key – This key can activate the auxiliary alarm when pressed for two seconds. If your system is connected to a monitoring center, an emergency report could be sent to that center.
Police (Panic/Hold-Up) Key - This key can sound a local audible alarm when pressed for two seconds. If your system is connected to a monitoring center, an emergency report could be transmitted to that center. NOTE: Some Panic/Hold­Up alarms are programmed to be silent at the protected site while reporting an alarm to the monitoring center. Check with your installing company to determine how your security system will respond to the Panic/Hold-Up activation.
. You should press these keys only in an emergency situation
6
Page 7
KEYPAD FUNCTIONS
g
g
g
g
g
g
g
g
ARMING YOUR SYSTEM IN THE “AWAY” MODE
AWAY is used when the user is away from the premise and wants the interior protected. Listed below are the steps to arm in the AWAY Mode:
Step 1 Close all protected doors and windows.
Ready li sensors are secure.
in that zone can be violated without affecting the
The security system will not arm if the flashing.
If the possible. If not, contact your installin this booklet for service.
ht will be on or flashing when all protected zones and
NOTE: If any zones are bypassed, a sensor
ready light.
power light
ready light
is off, you have no AC power. Restore power if
company listed on page 1 of
is not on or
Step 2
Note: The exit light will flash rapidly for the last 10 seconds of the exit delay as a warning to the user that the exit time is about to expire. The user may wish to disarm and rearm the system if more time is needed.
ARMING YOUR SYSTEM IN THE “STAY” MODE
STAY is used when the user is inside the premise and wants protection around the perimeter. Listed below are the steps to arm in the STAY Mode:
Step 1 Close all protected doors and windows.
Step 2
Enter your user code to arm the system.
The armed and exit lights will illuminate.
You may now leave the building.
Ready li
sensors are secure.
in that zone can be violated without affecting the
The security system will not arm if the flashing.
If the possible. If not, contact your installin this booklet for service.
Enter your 4 or 6 digit user code.
If “Auto Bypass” is enabled, all interior zones will be bypassed if you
do not leave throu enabled, omit Step 3.
When “Auto Instant” is enabled, if you do not leave throu desi that the entry/exit doors no longer have an entry delay. If “Auto Instant” is enabled, omit Step 4.
ht must be on or flashing when all protected zones and
NOTE: If any zones are bypassed, a sensor
ready light.
power light
nated entry/exit door the
is off, you have no AC power. Restore power if
h a designated entry/exit door. If Auto Bypass is
ready light
company listed on page 1 of
instant light
will illuminate indicatin
is not on or
h a
7
Page 8
Step 3
g
g
g
gg
Press the [STAY] key.
stay light
The bypassed. (All interior devices will bypass automatically, user freedom of movement within the interior area.)
bypass light
The zone(s) have been bypassed previously by the user, the li correspondin user that a zone(s) may be unprotected and can be faulted without an alarm.
will illuminate indicating that all interior zones are
iving the
will illuminate if any zone(s) are bypassed. If any
to the bypassed zone(s) will illuminate, alerting the
ht(s)
Step 4
USING THE QUICK ARM (Optional, see page 1) The Quick Arm feature may be used if it is enabled. Quick Arm will allow the user
to arm the security system in the AWAY mode by pressing the [EXIT] key, or arm in the STAY mode by pressing the [STAY] key. This feature is used for ARMING ONLY, and will not disarm the security system. This is ideal for a maid or baby sitter code, etc.
CHANGING MODES WHILE YOUR SYSTEM IS ARMED
Pressing the [STAY] key will turn on/off (toggle) a delay on entry/exit doors
(Optional) Press the [BYPASS] key at this time to turn on/off (toggle) all
(Optional) When armed, pressing the [EXIT] key will start the exit delay,
To to the [STAY] key again.
The have no entry delay.
and turn on/off (toggle) the
designated interior zones.
enabling you to leave the building.
le from a “delayed entry” mode to an “Instant” mode, press
instant light
will illuminate indicating that the entry/exit doors
instant light
.
IMPORTANT !
The
instant light
the building; otherwise you will create an alarm. You may restore an
needs to be off at this time if you plan on re-entering
entry delay by pressing the [STAY] key again.
8
Page 9
DISARMING YOUR SYSTEM
When you enter the protected area through one of the designated Entry/Exit doors, the keypad control will sound a continuous tone for the duration of the entry delay time, or until you enter a valid code. The red and the tone will stop. The security system is now DISARMED. If a valid code is not entered before the end of the entry delay, an alarm will occur. (NOTE: If the
red
armed light
been activated in your absence. Leave the building immediately and call your alarm company and/or the police from a safe location.)
CANCEL / ABORT FEATURE (Optional, see page 1)
is flashing during the entry delay, the alarm system has
armed light
will go off
cancel light
The followed by the [CANCEL] key while this light is flashing, all abortable reports will stop the communication process. Entering a code followed by the [CANCEL] key during or after an alarm report to the central station will cause the come on. It will stay on until the central station has received the cancel report.
BYPASSING ZONES
If you wish to bypass one or more zones, this must be done while the system is in the disarmed state. The following steps are used for bypassing zones:
Step 1 Press the [BYPASS] key. Step 2 Enter user code, if required (optional). The Step 3 Enter the 1-digit number for the zone you wish to bypass. (Example:
Step 4 Press the [BYPASS] key again. Step 5 The corresponding
Step 6 Press the [BYPASS] key again -or- press the [#] key to exit the
will flash during an abort delay time. If a code is entered
cancel light
bypass light
Press the [1] key for zone 1, press [4] for zone 4.)
zone light
been bypassed. Repeat steps 3 and 4 for any other zone(s) that need to be bypassed.
Bypass Mode. The Bypass Mode.
bypass light
will illuminate indicating the zone has
will stop flashing upon exiting the
flashes.
to
GROUP BYPASS
By pressing the [BYPASS] key, followed by the [0] key, then the [BYPASS] key again, all zones that are designated as group bypass zones will be bypassed. Press the [BYPASS] key again to exit group bypassing.
9
Page 10
UNBYPASSING
To unbypass zones, perform the bypassing procedure on the zone(s). The corresponding light for that zone will go off when unbypassed. NOTE: All zones
will automatically be unbypassed each time the system is disarmed.
TURNING THE DOOR CHIME ON AND OFF
The door chime is turned on or off by pressing the [CHIME] key while the system is in the disarmed state. If the chime is on the chime is off, the the chime feature on/off and produce a momentary ding-dong sound.
chime light
will be off. Each press of the [CHIME] key will toggle
chime light
will be illuminated. If the
CHANGING USER CODES
Step 1 Your system must be in the Disarmed state to change user codes. Step 2 Press [U]-[5]. Step 3 Enter a “Master Arm/Disarm Code”. Step 4 The Step 5 Enter the 2 digit “user number” (always enter 2 digit such as [0] - [3]
Step 6 Enter the new four (4) or six (6) digit “user code”.
ready light
for user 3, or [5] - [2] for user 52).
Series LED Keypad:
first digit of the “user code”. (Lights 1-8 on = code is blank; lights 1-8 off = “0”; lights 1 and 8 = “9”.) Use the up and down scroll keys to view the next digit or enter a new 4- or 6-digit “user code”. While using the up and down scroll keys you can change any digit by entering a new digit. This will advance you to the next digit. NOTE: To delete a user code, enter [U]-[U]-[U]-[U] for a 4-digit code, or [U]-[U]-[U]-[U]-[U]-[U] for a 6-digit code.
Step 7 The
Step 8 If another “user code” needs to be programmed, return to Step 5. Step 9 Press the [#] key while the
ready light
the code is rejected, the sounder will beep 3 times.
Code Programming Mode.
will flash.
Note for NX1300
The zone lights will illuminate specifying the
will flash indicating you are back at Step 4 above. If
ready light
10
is flashing to exit the User
Page 11
ASSIGNING USER CODE AUTHORITY LEVELS
Assign authority levels to users by following the steps below. Assign user codes before assigning authority levels.
Step 1 Press [U]-[6]. Step 2 Enter a “Master Arm/Disarm Code”. Step 3 The Step 4 Enter the 2 digit “user number” to be assigned authority (always 2
ready light
digits such as 03 for user 3). The
instant light
Step 5 Lights illuminated indicate the authority levels assigned to this code.
An explanation of the lights is listed below. You may toggle (turn on/off) the authority level by pressing the number for that authority level.
LIGHT AUTHORITY LEVELS IF LIGHT 8 IS OFF
1 2 3 4 5 6 7
8
Step 6 Press [U] [U].
This returns you to Step 3 above. At this point you may enter another user number to assign authority level. Repeat Steps 4 - 6 until you have assigned authority levels to all user numbers.
will flash.
ready light
will flash.
Reserved ( Arm Only Arm Only After Closing Time Master Arm/Disarm (can program other codes) Arm/Disarm Bypass Zones Open / Close Reporting
If this light is on, this code is programmed as a function code. Do not change! Press [#] - [#] to exit.
Note: Do not change if on.)
is constant and the
Step 7 Press the [#] key to exit the Assigning Authority Level Program.
11
Page 12
OTHER KEYPAD FUNCTIONS
SETTING THE KEYPAD TONE
Step 1 Press [U]-[0]. Keypad is now in the “Adjust Tone” mode. Step 2 Pressing the [1] key will make the keypad sounder go to higher
tones, pressing the [2] key will make the keypad sounder go to lower tones.
Step 3 When the desired tone is reached, press the [#] key to set this tone
and exit from the “Adjust Tone” mode.
VIEW ALARM MEMORY
Step 1 Press [U]-[3]. The zone(s) that created the last alarm will be
displayed on the keypad.
Step 2 The
TEST FUNCTION
If programmed, this function will perform a battery test, communicator test, and/or a siren test. No alarms will be sent and no reports will be sent unless a communicator test is performed, at which time a test signal will be sent.
Step 1 Press [U]-[4]. The test will be performed as programmed. Step 2 If the siren test is performed, enter a user code to silence the siren.
RESET FUNCTION
This function is used to reset Smoke Detectors, Zone Troubles, and Zone Tampers.
Step 1 Disarm the system if not disarmed. Step 2 Press [U]-[7]. Resets have now been performed. Step 3 If the keypad begins beeping, the reset did not execute properly.
ALARM MEMORY
alarms and will light steady those zones that were bypassed during the last alarm.
– Optional
Enter your code to silence the keypad. Wait a few minutes and repeat step 2 to attempt another reset. If the keypad still beeps after repeated attempts, please contact your installer.
feature will flash those zones that created
12
Page 13
SETTING THE SYSTEM DATE
g
Step 1 Press the [U]-[9]-[6]. Step 2 Enter the “Master Code”. Step 3 Enter the “Day of Week “
1 = Sunday 3 = Tuesday 5 = Thursday 7 = Saturday 2 = Monday 4 = Wednesday 6 = Friday
Step 4 Enter the “Month Code”. Must always be two (2) digits.
01 = January 05 = May 09 = September 02 = February 06 = June 10 = October 03 = March 07 = July 11 = November 04 = April 08 = August 12 = December
Step 5 Enter the “Day Code”. Must always be two (2) digits.
Example: The 5
th
would be entered as [0]–[5].
Step 6 Enter the last two digits of the “Year Code”.
Example: For 1997 enter [9]–[7].
SETTING THE SYSTEM CLOCK
Step 1 Press [U]-[9]-[7]. Step 2 Enter the “Master Code “. Step 3 Enter the “hour code” which must be two (2) digits. Note: The clock
is a 24-hour clock. Refer to the following table.
Step 4 Enter the “minutes code” which must be two (2) digits.
Example: 7 minutes after would be entered [0]–[7].
Time Hour Code Time Hour Code Time Hour Code
12:00
ht
Midni 1:00 AM 01 9:00 AM 09 5:00 PM 17
2:00 AM 02 10:00 AM 10 6:00 PM 18 3:00 AM 03 11:00 AM 11 7:00 PM 19
4:00 AM 04 5:00 AM 05 1:00 PM 13 9:00 PM 21
6:00 AM 06 2:00 PM 14 10:00 PM 22 7:00 AM 07 3:00 PM 15 11:00 PM 23
00 8:00 AM 08 4:00 PM 16
12:00 Noon
12 8:00 PM 20
13
Page 14
KEYPAD CONTROL TONES (BEEPS)
A sounder is built into the keypad. If programmed, your system keypad may sound for any of the following reasons:
Beeps for all keypresses.  Sounds a continuous tone during the Entry delay time.  Pulses when a day zone is violated while the system is disarmed.  Pulses when a FIRE zone has a trouble condition.  Beeps 3 times for trying to arm with the “Ready” light off, if “Force Arming”
has not been selected.
Beeps for 1 second or emits a “ding-dong” sound for the “Chime” feature.  Beeps during an exit delay; beeps rapidly for the last 10 seconds of an exit
delay; and beeps 1 second at the end of the exit delay.
Pulses when the armed status changes and the AC power is off.  Pulses when the armed status changes and any zone(s) are bypassed.  Pulses when the armed status changes and a low battery is detected.  Pulses when the armed status changes and a Tamper condition is detected.  Pulses when one or more of the following conditions are detected: Zone or
Box Tamper, Low Battery, AC Power Fail, or Expander trouble.
Entering a valid code will silence the keypad sounder when it is pulsing. The arm/disarm state of your system will not change when entering a code to silence a pulsing keypad sounder. Please contact your installer if a trouble condition exists.
14
Page 15
SERVICE MENU
g
g
The
service light
light
is “on”, press the [U] key followed by the [2] key to determine the service condition. One or more zone lights will illuminate indicating what service(s) is required. Call your service provider immediately for these problems. Below is a listing of what each light means in a service condition.
LIGHT PROBLEM
1
2 ZONE TAMPER -
3 ZONE LOW BATTERY -
4 ZONE LOSS OF SUPERVISION -
5 ZONE TROUBLE -
6 RESERVED 7 FAILURE TO COMMUNICATE -
8 LOSS OF SYSTEM TIME
EXIT
will be “on” if the security system requires service. If the
SYSTEM FAULT -
illuminated corresponds to the system fault(s) below:
Over Current Fault
1
Siren Trouble
2
Box Tamper
3
Expander Power
4
Press the [#] key to return to the 1 of 8
illuminate showing the zone(s) that are tampered. Press the [#] key to return to the 1 of 8
illuminate showin applies to wireless zones. Press the [#] key to return to the 1 of 8
service lights li
ht(s)
will illuminate showing which zone(s) has loss of supervision. This only applies to wireless zones. Press [#] key to return to the 1 of 8
illuminate showing which zone(s) has a trouble condition. Press the [#] key to return to the 1 of 8
.
is a failure to communicate between your system and the central station.
been a loss of power and your system clock needs to be reset. Instructions are on page 13.
Press the [#] key to exit the Service Light mode.
Press the [1] key. The
service lights
Press the [2] key and the
service lights
Press the [3] key. The
which zone(s) has a low battery. This only
.
service lights
Press the [5] key and the
.
Press the [4] key and the
.
service lights
This light will illuminate when there
- This light will illuminate when there has
zone light(s)
Expander Low Battery
5
Expander Box Tamper
6
Expander Trouble
7
Reserved
8
.
zone light(s)
zone light(s)
zone light(s)
.
service
that is
will
will
zone
will
15
Page 16
EMERGENCY EVACUATION PLANS
An emergency evacuation plan should be established for an actual fire alarm condition. For example, the following steps are recommended by the National Fire Protection Association and can be used as a guide in establishing an evacuation plan for your building.
Draw up a floor plan of your home. Show windows, doors, stairs, and rooftops that can be used for escape. Indicate each occupant's escape routes. Always keep these routes free from obstruction. Determine two means of escape from each room. One will be the normal exit from the building. The other may be a window that opens easily. An escape ladder may have to be located near the window if there is a long drop to the ground below. Set a meeting place outdoors for a headcount of the building occupants. Practice escape procedures. In a home, sleep with bedroom door closed; this will increase your escape time. If you suspect fire, test the door for heat. If you think it is safe, brac e your shoulder against the door and open it cautiously. Be ready to slam the door if smoke or heat rush in. Practice escaping to the outdoors and meeting in an assigned spot. Call the Fire Department from a neighbor's phone.
NOTE: After the installation of your Security System has been completed, notify your local Fire and Police Departments to give them your name and address for their records. Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms. This equipment should be installed in accordance with the National Fire Protection Association's Standard 72. For additional information write the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
The following are examples of evacuation plans. A plan unique to your home or business should be drawn and memorized by each occupant.
16
Page 17
SYSTEM NOTES
17
Page 18