CAC / BDP 40GRQ, 38GRQ, 538FR, 619FB Owner's Manual

40GRQ / 619FB / 38GRQ / 538FR High- Wall Ductless Split System Sizes 09 - 18
Owner’s Manual
TABLE OF CONTENTS
PAGE
SAFETY PRECAUTIONS 2.....................................................................................
GENERAL 2.................................................................................................
DISPLAY PANELS 5..........................................................................................
REMOTE CONTROL 6........................................................................................
CLEANING, MAINTENANCE AND TROUBLESHOOTING 9........................................................
NOTE TO EQUIPMENT OWNER:
Please read this Owner’s Information Manual carefully before installing and using this appliance and keep this manual for future reference.
For your convenience, please record the model and serial numbers of your new equipment in the spaces provided. This information, along with the installation data and dealer contact information, will be helpful should your system require maintenance or service.
UNIT INFORMATION
Model # ___________________________________
Serial # ___________________________________
INSTALLATION INFORMATION
Date Installed _____________________________
DEALERSHIP CONTACT INFORMATION
Company Na me: _________________________________
Address:_________________________________________
________________________________________________
Phone Number:__________________________________
Technician Name:_________________________________
________________________________________________
SAFETY PRECAUTIONS
!
WARNING
PERSONAL INJURY, DEATH, OR PROPERTY
DAMAGE HAZARD
Failure to follow this warning could result in personal injury, death, or property damage.
Read and follow all instructions and warnings, including labels shipped with or attached to unit before operating your new air conditioner.
Any time you see this symbol in manuals, instructions and on the unit, be aware of the potential for personal injury. There are three levels of precaution:
DANGER identifies the most serious hazards which will result in severe personal injury or death.
WARNING signifies hazards that could result in personal injury or death.
CAUTION is used to identify unsafe practices which would result in minor personal injury or product and property damage.
NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.
!
PERSONAL INJURY, DEATH AND / OR PROPERTY
Failure to follow this warning could result in personal injury, death or property damage.
Improper installation, adjustment, alteration, service, maintenance, or use can causeexplosion,fire,electricalshock, or other conditions which may cause personal injury or property damage.
Consult a qualified installer, service agency, your distributor or branch for information orassistance. The qualified installer or service agency must use factory-authorized kits or accessories when modifying this product.
WARNING
DAMAGE HAZARD
GENERAL
The high wall fan coil unit provides quiet, maximum comfort. In addition to cooling and/or heating, the high wall fan coil unit matched with an outdoor condensing unit will filter and dehumidify the air in the room to provide maximum comfort.
IMPORTANT: The high wall fan coil unit should be installed by authorized personnel only; using approved tubing and accessories. If technical assistance, service or repair is needed, contact the installer.
The high wall fan coil unit can be set up and operated from the remote control (provided). If the remote is misplaced, the system
can be operated from the “Auto” setting on the unit.
Operating Modes:
The high wall fan coil unit has five operating modes.
S Fan only S Auto S Heating S Cooling S Dehumidification (DRY)
Fan Only
In Fan Only mode, the system filters and circulates room air without changing room air temperature.
Auto
In Auto mode, the system will automatically cool or heat the room according to the user- selected set point.
Heating
In Heating mode, the system heats and filters room air.
Cooling
In Cooling mode, the system cools, dries and filters room air.
Dehumidification (DRY)
In Dehumidification mode, the system dries, filters and slightly cools room air temperature. Use of this mode does not take the place of a dehumidifier.
Remote Control
The remote control transmits commands to set up and operate the system. The control has a window display panel that shows the current system status. The control can be secured to a surface when used with the mounting bracket provided.
2
INDOOR UNIT PART NAMES
Indoor unit
3
Par t Name
1. Front Panel
2. Aux. Button
3. Filter
4. Remote Controller
5. I nter-Connection Wi re
6. Drain Hose
7. Refrigerant Lines
Air inlet
1
2
Air outlet
4
Air inlet
Outdoor uni t
Air outlet
Fig. 1 - Indoor/Outdoor Unit
7
5
6
DISPLAY PANELS
NOTE: The display panel on the indoor unit can be turned on or off using the LIGHT button on the remote control.
* The temperature readout will be replaced by an error code if there is a malfunction.
3
REMOTE CONTROL PART NAMES
1
3
56
7
10
11
12
15
16
2
4
8
9
13
14
17
1 ON/OFF button
+/- button
2
Cool button
3
Heat button
4
Fan button
5
6 I Feel button
Up down swing button
7
8
Mode button
9
Left right swing button
10
T-ON/T-OFF button
11
Clock button
12
"Blank"
13
Temp button
14
X-Fan button
15
Light button
16
Sleep button
17
Wifi button
Remote Control Display
Fig. 2 - Remote Control
Fig. 3 - Remote Control Display
4
REMOTE CONTROL
!
CAUTION
EQUIPMENT DAMAGE HAZARD
Failure to follow this caution may result in equipment damage. Handle the control with care and avoid getting the control wet.
NOTE: To switch between _Cand_F, push the “MODE” and “- ” button simultaneously while the remote controller is off.
IMPORTANT: The remot e control can operate the unit from a
distance of up to 25 ft. (7.6 m) as long as there ar e no obstructions. This is one way communication only (from remote control to fan coil).
The remote control can perform the following basic functions:
S Turn the system ON and OFF
S Select operating mode
S Adjust room air temperature set point and fan speed
S Adjust airflow direction
Battery Installation
Two AAA 1.5 v alkaline batteries (included) are required for operation of the remote control.
To install or replace batteries:
1. Slide the back cover off the control to open the battery compartment.
2. Remove old batteries if you are replacing the batteries.
3. Insert batteries. Follow the polarity markings inside the battery compartment.
4. Replace battery compartment cover.
A08299
NOTE:
1. When replacing batteries, do not use old batteries or a different type battery. This may cause the remote control to malfunction.
2. If the remote is not going to be used for several weeks, remove the batteries. Battery leakage may damage the remote control.
3. The average battery life under normal use is about 6 months.
4. Replace the batteries when there is no audible beep from the indoor unit or if the Transmission Indicator fails to light.
REMOTE CONTROL MATCHING
The System require the wireless remote controller to be matched to the indoor High wall unit before beginning any operations, othe rwise the indoor High wall unit will not accept commands from the remote controller. Follow the instructions below to automatically match the remot e controlle r to the indoor high wall unit:
1. Turn on electrical power to the indoor and outdoor units. The indoor high wall unit powers up in the Off (or Sta ndby) mode.
2. Hold the remote controller 5 to 6 feet from the indoor high wall unit.
3. Point the remote controller at the indoor wall unit and press the Blank button for 3 seconds.
4. The indoor high wall unit provides 3 beeps to signal a successful match.
5. Press the Power ON button on the remote controller. The green indicator light displays on the indoor high wall unit.
6. The remote controller is matched and ready for use. If the indoor unit and remote controller fail to match, check the remote controller batteries, move closer and repeat the matching process again.
NOTE: This is a one- time requirement only. The remote controller and indoor high wall unit need to be successfully matched only o nce.
Remote Control Operation - Quick Start
NOTE: When transmitting a command from the remote control to
the unit, be sure to point the control toward the LED display on the front panel of the unit. The unit confirms receipt of a command by sounding an audible beep.
1. Turn the unit on by pushing the ON/OFF button.
2. Select the desired mode by pushing the mode button.
Fig. 4 - Modes
3. Select the temperat ure set point by pointing the cont r ol toward the unit and pressing the “+” or “- ” temperature set point buttons until the desired temperature appears on screen.
4. Select the desired fan speed by pressing the FAN SPEED button to select desired fan speed.
NOTE: If unit is operating in Dry mode (X- FAN), low fan speed will be displayed and the fan speed cannot be changed.
5. Set the airflow direction. When the unit is turned on, the louvers default to the cooling or heating position. The user can adjust the default louver position by pushing the “SWING” buttons. For details on operating the SWING louvers, refer to the Remote Control Functions section.
Emergency Operation
If the remote control is lost, damaged, or the batteries are exhausted, the ON/OFF button on the unit can be used to run the unit.
Press the ON/OFF button once briefly when the system is off. T o stop emergency operation, push the ON/OFF button once.
panel
Display panel
Warning: Use insulated object to press the auto button
aux. button
Fig. 5 - Emergency Operation
Combination of “MODE” and “ - ” Buttons:
Switch between Fahrenheit and Centigrade. At unit OFF, press the “MODE’” and “- ” buttons simultaneously to switch between _Cand _F.
5
REMOTE CONTROL FUNCTIONS
The remote control is the interface between the user and the high- wall systems. Commands are entered by the user to control the system. Any command that has been entered with the remote control will remain in the memory until it is changed by the user or the batteries are replaced.
NOTE: When entering commands, point the remote control in
the direction of the LED display on the front panel. The appears for a short period of time on the remote control when the command is entered. The unit only emits an audible beep when the signals are received correctly.
ON/OFF:
Press this button to turn unit on and off.
MODE:
Each time this button is pressed, a mode is select ed in a se quence that goes from AUTO, COOL, DRY, FAN and HEAT, as shown below:
T ANRY AT
Fig. 6 - Modes
AUTO mode is the default setting at start- up. In AUTO mode, the set temperature will not be displayed on the LCD, and the unit automatically selects the suitable operation mode to provide comfort based on parameters set from the factory.
—:
Press this button once to decre ase the setpoi nt by 1_F. If the button is pressed for more than two seconds, the setpoint decr eases rapidly in increments of 1_F. In AUTO mode, set temperature is not adjustable.
+:
Press this button to increase the setpoint by 1_F. If the button is pressed for more than two sec onds, the setpoint increases rapidly in increments of 1_F. In AUTO mode, set temperature is not adjustable.
COOL:
To cool to the selected set point and remove moisture. System varies compressor speed to maintain desired temperature.
HEAT
:
To heat to selected room set point. System varies compressor speed to maintain desired room temperature.
FAN:
This button is used to set the fan speed in the following sequence.
Fig. 7 - Fan speed
:
Press the Vertical Swing Louver button to select five different vertical (up and down) air discharge directions including Continuous Sweep. The Swing Louver icon appears. Press this button to set swing angle, which changes directions as shown below.
Indicates louver swings back and forth in the five directions, as shown.
1
1023
OFF
5
Fig. 8 - Swing buttons
4
OPER
:
Press the Horizontal Swing Louver button to select five different horizontal (left and right) air discharge directions including Continuous Sweep. The Horizontal Swing Louver icon appears. Press this button to set swing angle, which changes in direction as shown in the following figure.
no display
(stops at current
position)
Fig. 9 - Horizontal Swing Louver Angles
FEEL:
I
Press this button to use the I FEEL functi on, and the icon appears. The unit senses room tempe rature at the remote controlle r ins tead of at the indoor unit. It then adjusts airfl ow and temperature accordingly for the ultimate in personal comfort control and energy savings.
Press the button again to exit this function. For best performance, keep remote controller away from heat or cold temperature sources while using this function.
TEMP:
Each time this button is pressed, the display on the indoor unit is switched in a sequence that goes from No display > Set Temperature > Indoor Ambient Temperature, as shown below.
no display
Fig. 10 - Temp Modes
When selecting temperature indicator on indoor unit displays the set temperature.
When selecting indicator on indoor unit displays indoor ambient temperature; 3s later or within 3s it receives another remote controller signal that will return to display the setting temperature.
NOTE: This model does not have an outdoor ambient temperature function. While the remote controller can operate
and the indoor unit displays the set temperature. It’s defaulted to display the set temperature when turning on the unit.
X- F
AN:
Press the X- FAN button in COOL or DRY mode to activate the DRY function and the X- FAN icon appears. When this function is activated, the indoor fan continues to run for 2 minutes to dry the indoor coil after the unit is turned off. X - FAN is not available in AUTO, FAN and HEAT mo d e.
with remote controller or no display, the
with the remote controller, the temperature
T- ON button (Timer ON)
To set when you want the unit to turn On at the end of a selected time period, use the button labeled “T- ON” on the remote controller. Press this button to make the clock icon disappear, replaced with the word “ON” (blinking). Press “+” or“- ” buttons to adjust timer setting 1 minute at a time. Press and hold “+” or “- ” button to set timer more quickly. Press“T- ON” button again to confirm setting, and the word “ON” stops blinking. To cancel, press“T- ON” button again.
T- OFF button (Timer OFF)
NOTE: Under Timer On and Off status, you can set T- ON and T- OFF simultaneously. Before setting timer, be sure to set clock to correct time.
6
CLOCK SETTING
Press this button to set clock time. The Clock icon on remote controller blinks. Within 5 seconds, press “+” or “- ” button to set clock time. With each press of the “+” or “- ” buttons, the clock time increases or decreases by 1 minute. To quickly adjust the time setting, press and hold “+” or “- ” button for 2 seconds.
Release the button when you have reached the desired time setting. Press the “CLOCK” button to confirm the time, and clock icon stops blinking.
NOTE: Clock time adopts 24- hour mode. A 12- hour format is not available.
SLEEP MODE:
The unit automat icall y adjusts room tempe r ature during your sleep time. This slight change in tempe r ature will not affe ct your comfort level due to the natural eff ects that sleeping has on the body , however it saves on energy cons umption and lowers your electr i c bill.
The unit has four Sleep Modes to select from. Press the SLEEP button to select Sleep 1, Sleep 2, Sleep 3, Sleep 4 modes or Cancel. The SLEEP icon appears.
TRADITIONAL MODE - SLEEP
In Traditional Mode the unit slowly relaxes the room set temperaturebyupto4_F until Sleep Mode is cancelled.
1
At any time, you may press the “ON/OFF,” “Mode,” “Timer,” “Sleep” or “Turbo” buttons to cancel the Sleep 3 Mode.
NOTE: During this procedure, if no button is pressed within 10 seconds, the remote controller automatically exits the sleep curve setting and resumes the original display. If the ON/OFF, MODE, TIMER, SLEEP, COOLING or HEATING button is pressed during the setting or inquiry procedure, the remote controller exits the sleep curve setting.
SIESTA MODE 4:
In Siesta Mode the unit automatically changes the room temperature every 30 minutes based on the room temperature setting. The Sleep Mode continues until cancelled.
Cooling Mode Heating Mode
Cooli ng Mode
Fig. 11 - Cooling and Heating Modes
EXPERT MODE - SLEEP
In Expert Mode the unit adjusts the room set temperature at a rate based on the starting set temperature value. Sleep Mode continues until cancelled.
Cooling Mode Heat ing Mode
Fig. 12 - Cooling and Heating Modes
2
Heat ing Mode
DIY MODE SLEEP 3
You are required to enter eight (8) room set point values for eight (8) hours of run time. The last room set point value is maintained until the sleep mode is cancelled.
In Sleep Mode 3, press the “Prog” button to enter the setup mode. The remote control l er displays “1:00” in the time location. Use the “+” and “-” buttons to select the desired room set point for the firs t hour of run time. Then press the “Prog” button to save the set point.
Repeat this sequence for the eight (8) room set point values. After all eight (8) values have been entered, the remote controller automatically reverts to standard time and temperature display, and the Sleep 3 Mode starts.
Fig. 13 - Siesta Mode
NOTE: Sleep function can not be set in AUTO mode.
LIGHT:
This function allows the user to turn the display ON or OFF on the front panel.
Press the light icon OFF. The remote control displays the Light Icon
to turn the indoor unit front panel ON or
.
WIFI Button:
Press and hold this button for three seconds to turn WIFI function on or off. See the “Operation of Smart Control” section for more information.
Only the set point temperature appears on the front panel and on the remote controller.
COMBINATION BUTTONS
Combination of “+” and “- ” Buttons:
Press “+” and “- ” buttons simultaneously for 8 seconds to lock or
unlock the keypad. If the remote control is locked,
In this case, pressing any button, acknowledge the keypad is locked. Repeat the process to unlock the remote controller.
46
_F Heating Functions:
Under the heating mode, press the “TEMP” and “CLOCK” buttons simultaneously to start the 46_F heating function. When this function starts, the “$” and 46_F icons appear on the remote controller, and the air conditioner maintains the heating status. Press the “TEMP” and “CLOCK” buttons simultaneously again to exit the 46_F heating function.
NOTE: Under the 46_F heating function, the fan speed defaults to the auto speed and it can not be adjusted. Under the 46_F heating function, the set temperature can not be adjusted. Press the TURBO button and the remote controller will not send the signal. The Sleep function and the 46_F heating function can not operate at the same time. If the 46_F heating function has been set under the Cooling mode, press the Sleep button to cancel the 46_F heating function. If the Sleep function was set under the Cooling mode, the 46_F heating function cancels the Sleep function.
7
blinks three times to
is displayed.
CLEANING, MAINTENANCE AND TROUBLESHOOTING
!
CAUTION
ELECTRICAL SHOCK HAZARD
Failure to follow this caution may result in personal injury or death. Always turn off power to the system before performing any cleaning or maintenance to the system. Turn off the outdoor disconnect switch located near outdoor unit. Be sure to disconnect indoor unit if on a separate switch
!
CAUTION
EQUIPMENT DAMAGE/OPERATION HAZARD
Failure to follow this caution may result in equipment damage or improper unit operation. Operating the system with dirty air filters may damage the indoor unit and could cause reduced cooling performance, intermittent system operation, frost build- up on indoor coil or blown fuses.
Periodic Maintenance
Periodic maintenance is recommended to ensure proper operation of the unit. Recommended maintenance intervals may vary depending on the installation environment, e.g., dusty zones, etc. Refer to Table 1.
!
CAUTION
CUT HAZARD
Failure to follow this caution may result in personal injury.
The coil fins are very sharp. Use caution when cleaning.
Always wear safety protection.
Cleaning the Coil
Clean the coil at the beginning of each cooling season, or when necessary. Use a vacuum cleaner or a long- bristle brush to avoid damage to the coil fins.
Air Filters
Remove and clean the air filters once a month. NOTE: If air filters show signs of excessive wear or are torn, they must be replaced. Contact your local dealer for replacement filters.
1. Open front panel on unit.
2. Pull filters down to remove.
3. Vacuum filters.
4. Clean with warm water.
5. Shake filter to remove excess water and dry thoroughly.
6. Replace filter by sliding into rack until filter snaps in place.
7. Close front panel on unit.
!
CAUTION
EQUIPMENT DAMAGE HAZARD
Failure to follow this caution may result in equipment damage. When cleaning the front panel, do not use water hotter than 105_F (40.56_C) and do not pour water onto the fan coil. Do not use abrasive or petroleum based cleaners as they may damage the front panel.
Indoor Unit Front Panel
To clean the front panel on the indoor unit, wipe the outside with a soft, dry cloth. If necessary, a mild liquid detergent can be applied and wiped off with a dry cloth.
Preparing for Extended Shutdown Period
Clean the filters and reposition them in the unit. Operate the unit in Fan only mode for 12 hours to dry all internal parts.
Turn main power supply off and remove batteries from the remote control.
System Operation Recommendations
The items outlined in the following list helps to assure proper system operation:
S Replace both remote control batteries at the same time. S Point the remote control toward the unit display panel when
transmitting a command.
S Keep doors and windows closed while unit is operating. S Contact an authorized service representative if a problem arises
that cannot be easily resolved.
S Do not perform cleaning or maintenance activities while unit
is on.
S Keep display panel on unit away from direct sunlight and heat
as this may interfere with remote control transmissions.
S Do not block air intakes and outlets on the indoor or outdoor
units.
Energy Saving Recommendations
The following recommendations add greater efficiency to the ductfree system:
S Select a comfortable thermostat setting and leave it at chosen
setting. Avoid continually raising and lowering the setting.
S Keep unit filter clean. Frequent cleaning may be necessary
depending on indoor air quality.
S Use drapes, curtains or shades to keep direct sunlight from
heating room on very hot days.
S Do not obstruct air intake on front panel. S Turn on air conditioning before indoor air becomes too
uncomfortable.
Troubleshooting
Refer to Table 2 before contacting your local dealer.
8
Table 1—Periodic Maintenance
INDOOR UNIT EVERY 3 MONTHS EVERY 6 MONTHS EVERY YEAR
Clean Air Filter* Change Remote Control Batteries
OUTDOOR UNIT EVERY 3 MONTHS EVERY 6 MONTHS EVERY YEAR
Clean Outdoor Coil from Outside Clean Outdoor Coil from Inside† BlowAirOverElectricParts† Check Electric Connection Tightening† Clean Fan Wheel† Check Fan Tightening† Clean Drain Pans†
* Increase frequency in dusty zones.
{ Maintenance to be carried out by qualified service personnel. Refer to the Installation Manual
S
Table 2—Troubleshooting
PROBLEM POSSIBLE CAUSE SOLUTION
Indoor unit emits a bad odor on start- up
You hear water flowing noise when the unit is running
Indoor unit produces a mist when the air conditioner is running
Wireless remote control does not work
Water leaks into room from Indoor unit
Unit/System Does Not Work To protect the unit upon an immediate restart
Cooling is Not Working Properly
Heating is Not Working Properly
Unit Stops During Operation The Off timer is not operating correctly.
Air filter dirtyOutput air still has odor after cleaning filter.This is normal and is the refrigerant flowing
through the system.
This is normal cooling and is caused by high
humidity and temperature in the room.
Batteries are dead.
Unit needs to be reset.
Condensing water has overflowed Check indoor condensing drain or call your
after a stop, the system controller delays the unit for 3 minutes before allowing the unit to start back up.
The circuit breaker has tripped or a fuse
has blown.
Power failure.Error codes displayedVoltage is too low.The filter is blocked with dust.Temperature is not set properly.A window or door is open.The outdoor unit is obstructed.The fan speed is too low.The operation mode is in Fan instead of
Cool.
The filter is blocked with dust.Temperature is set too low.A window or door is open.The outdoor unit is obstructed.
Error codes displayed
S
S
S
S S S S S S
Clean the air filterContact your service representative.No maintenance required
No maintenance required. Mist should stop as
room is cooled down and the humidity is removed.
See battery replacement section in this manual
and replace batteries.
Turn off power to indoor unit. Remove plug from
wall and then reinsert plug. Restart unit.
representative.
After turning unit off, wait at least 3 minutes before
trying to restart.
Reset the circuit breaker or replace the fuse with
the specified replacement fuse.
Restart operation when the power is restored.Call your service representative.Call your service representative.
Clean the air filter .Check the temperature and reset if necessary.Close the window or door.Remove the obstruction.Change the fan speed selection.Change the operating mode to Cool or reset the
unit.
Clean the air filter .Check the temperature and reset if necessary.Close the window or door.Remove the obstruction.Restart the operating mode.
Call your service representative.
9
Copyright 2015 CAC / BDP S 7310 W. Morris St. S Indianapolis, IN 46231
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Edition Date: 06/15
10
Catalog No:OM38- 40GR - 03
Replaces:OM38- 40GR - 02
Loading...