CAC KSACN0601AAA, KSACN0701AAA Installation Instructions

Installation Instructions
Wired Remote Controller 7 Day Programmable Thermostat Ductless Systems KSACN0601AAA (High Wall / Console Models) KSACN0701AAA (Cassette / Ducted / Console / Air Handler Models)
Fig. 1 — Wired Controller
NOTES: Read the entire instruction manual before installing the wired controller.
Images are for illustration purposes only. Actual models may differ slightly.
IM-KSACN0 6(7 )01 -01 Specifications subject to change without notice. 1

TABLE OF CONTENTS

PAGE
SAFETY CONSIDERATIONS...........................................................................................3
COMPATIBILITY ..............................................................................................................5
PREPARATION BEFORE INSTALLATION ................................................................... 6
WIRED CONTROLLER INSTALLATION PRECAUTION.............................................7
CONTROLLER DIMENSIONS .........................................................................................7
INSTALLATION ................................................................................................................8
APPENDIX 1.....................................................................................................................14
APPENDIX 2.....................................................................................................................22
TROUBLESHOOTING..................................................................................................... 23
SPECIFICATION ..............................................................................................................24
TECHNICAL INDICATIONS AND REQUIREMENT...................................................24
2 Specifications subject to change without notice. IM-KSACN06(7)01-01

SAFETY CONSIDERATIONS

Failure to follow this warning could result in personal injury or death. Before beginning any modification or installation of this kit, ensure the main electrical disconnect is in the OFF position. Ensure power is disconnected to the fan coil unit. On some systems both the fan coil and the outdoor unit may be on the same disconnect. Tag the disconnect switch with a suitable warning label. There may be more than one to disconnect.
CAUTION
INSTALLATION
Only the distributor or authorized professionals should install the unit. Installation by unskilled persons may lead to improper installation, electric shock, or fire. Re-installation must be performed by authorized professionals. Non-compliance may lead to electric shock or fire.
CAUTION
Read these instructions thoroughly and follow all warnings or cautions included in the literature and attached to the wired controller. Consult local building codes and National Electrical Code (NEC) for special requirements.
Recognize safety information. This is the safety-alert symbol . When you see this symbol on the wired controller and in instructions or manuals, be alert to the potential for personal injury. Understand these signal words: DANGER, WARNING, and CAUTION. These words are used with the safety-alert symbol.
DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.
IM-KSACN0 6(7 )01 -01 Specifications subject to change without notice. 3
NOTES: Save this manual for future reference.
• This manual provides a detailed description of the precautions that the user should be mindful of during operation. Keep this manual, after reading it, for future reference.
• To ensure correct service of the wired controller, read this manual carefully.
NOTES:
• Do not install the wired controller in a location vulnerable to flammable gas leaks. A fire may occur if there is a gas leak around the controller.
• Do not operate with wet hands or allow water to enter the wired controller, otherwise an electric shock may occur.
• The wiring should be a compatible connection cable for the current wired controller. Otherwise, electric leakage or heating may occur and result in a fire.
• Use the specified cables for wiring. Do not allow any external force to be applied to the connection wire terminals. Use this wiring to ensure there is no mechanical damage. Ensure the wire insulation is rated for the temperature it will sustain during operation. Failure to use this wire could result in a fire.
4 Specifications subject to change without notice. IM-KSACN06(7)01-01

COMPATIBILITY

Table 1 — Compatibility

Indoor Unit Type Indoor Model Number KSACN0601AAA KSACN0701AAA
HIGH WALL
CASSETTE
DUCTED
CONSOLE
AIR HANDLER
Optional
Standard
40MPHA
619PHA
DHMPHA
DLFPHA
40MAQ
619P*B
DHMSHA
DLFSHA
40MHH
DLFEHA
40MBQB*C
40MBCQ
DLFSCA
DLFLCA
40MBQB*D
40MBDQ
DLFSDA
DLFLDA
40MBQB*F
40MBFQ 9 - 12 18 - 58
DLFSFA 12 18 - 24
DLFLFA
40MBAA
DLFSAA
DLFLAA
NOTES:
+ 7 Day programmable compatible with indoor units starting with Serial Number 0216V10001
Not Compatible
‡ Compatible with indoor units starting with Serial Number 0117V10001
Units built prior to these serial numbers require a Control Board Replacement on the indoor unit.
IM-KSACN0 6(7 )01 -01 Specifications subject to change without notice. 5

PREPARATION BEFORE INSTALLATION

1. Confirm the following required parts have been supplied.

Table 2 — Parts

NO. NAME QTY. REMARKS
1 Wired controller 1 2 Installation and owner's manual 1 3 Screws 3 M4X20 (for mounting on the wall) 4 Wall plugs 3 For mounting on the wall 5 Screws 2 M4X25 (for mounting on the switch box) 6 Plastic screw bars 2 For fixing on the switch box 7 Battery 1 CR2032 3 VDC 8 Connection Extension Cable 1 19 feet (6 meters) 9 Adapter Board 1 Required for High Wall 40MAQ/619P*B/DHMPHA
10 Display Board 1 Required for High Wall 40MAQ/619P*B/DHMPHA
11 EMC Ferrite core (magnetic ring) 1
NOTES:
Extension wire available through RCD (Replacement Components)
- Part Number: 17401204000769.

2. Prepare the following assemblies on site.

Table 3 — Assemblies

No. Name
1 Switch box 1
2
Wiring tube
(insulating sleeve and
tightening screw)
(Embedded into Wall)
wrap the wires between the indoor unit and the wired remote controller after installation and around the Ferrite core twice.
QTY.
1
Specification
(Only for Reference)
Only Only
Remarks
6 Specifications subject to change without notice. IM-KSACN06(7)01-01

WIRED CONTROLLER INSTALLATION PRECAUTION

0.75 (19mm)
3.3in (84mm)
1.8in (46mm)
4.7in. (120mm)

1. This manual provides the wired controller installation method. Refer to the wiring diagram (see Fig. 7 — on page 11) for guidance on wiring the wired controller to the indoor unit.

2. The wired controller works in a low voltage circuit (5-12 VDC). DO NOT connect directly to any line voltage. Wiring clearance between the configured tubes should range 11.81-19.69 inches (30-50 cm) or above.

3. The shielded wire of the wired controller must be properly grounded.

NOTE: Upon completion of the wired controller connection, do not use any device to test the insulation.

CONTROLLER DIMENSIONS

0.79in (20mm)
4.7in (120mm)
2.4in (60mm)

Fig. 2 — Wired remote controller structural dimensions

IM-KSACN0 6(7 )01 -01 Specifications subject to change without notice. 7
1.7in (44mm)

INSTALLATION

Buckling position
Back plate
Flat head screwdriver
Front cover
Use the following steps to install the wired controller.

1. Remove the back plate of the wired controller.

2. Insert a flat head screwdriver into the slots in the bottom of the wired controller (2 slots).

Fig. 3 — Remove the back plate of the wired controller

NOTE: The PCB is mounted to the front cover of the wired controller. Be careful not to damage the board with the screwdriver.
8 Specifications subject to change without notice. IM-KSACN06(7)01-01