Cabletron Systems 9F122-12, 9F120-08, 9F125-08, SmartSwitch 9000 9F122-12, SmartSwitch 9000 9F120-08, SmartSwitch 9000 9F125-08 User Manual
Specifications and Main Features
Frequently Asked Questions
User Manual
SmartSwitch 9000
9F120-08, 9F122-12 & 9F125-08
User’s Guide
9031174-02
Notice
Notice
Cabletron Systems reserves the right to make changes in specifications and other information
contained in this document without prior notice. The reader should in all cases consult Cabletron
Systems to determine whether any such changes have been made.
The hardware, firmware, or software described in this manual is subject to change without notice.
IN NO EVENT SHALL CABLETRON SYSTEMS BE LIABLE FOR ANY INCIDENTAL, INDIRECT,
SPECIAL, OR CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING BUT NOT LIMITED
TO LOST PROFITS) ARISING OUT OF OR RELATED TO THIS MANUAL OR THE INFORMATION
CONTAINED IN IT, EVEN IF CABLETRON SYSTEMS HAS BEEN ADVISED OF, KNOWN, OR
SHOULD HAVE KNOWN, THE POSSIBILITY OF SUCH DAMAGES.
All Rights Reserved
Printed in the United States of America
Order Number:9031174-02
LANVIEW
CompuServe
i960 microprocessor
Ethernet
is a registered trademark, and
is a registered trademark of CompuServe, Inc.
is a registered trademark of Intel Corp.
is a trademark of Xerox Corporation.
SmartSwitch
is a trademark of Cabletron Systems, Inc.
i
Notice
FCC Notice
This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
NOTE:
device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial environment.
This equipment uses, generates, and can radiate radio frequency energy and if not installed in
accordance with the operator’s manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause interference in which case the user
will be required to correct the interference at his own expense.
WARNING:
party responsible for compliance could void the user’s authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class A digital
Changes or modifications made to this device which are not expressly approved by the
VCCI Notice
This is a Class A product based on the standard of the Voluntary Control Council for Interference by
Information Technology Equipment (VCCI). If this equipment is used in a domestic environment,
radio disturbance may arise. When such trouble occurs, the user may be required to take corrective
actions.
DOC Notice
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital
apparatus set out in the Radio Interference Regulations of the Canadian Department of
Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables
aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique
édicté par le ministère des Communications du Canada.
ii
Notice
DECLARATION OF CONFORMITY
ADDENDUM
Application of Council Directive(s):
89/336/EEC
73/23/EEC
Manufacturer’s Name:Cabletron Systems, Inc.
Manufacturer’s Address:35 Industrial Way
PO Box 5005
Rochester, NH 03867
European Representative Name:Mr. J. Solari
European Representative Address:Cabletron Systems Limited
Nexus House, Newbury Business Park
London Road, Newbury
Berkshire RG13 2PZ, England
Conformance to Directive(s)/Product Standards:
EC Directive 89/336/EEC
EC Directive 73/23/EEC
EN 55022
EN 50082-1
EN 60950
Equipment Type/Environment:
Networking Equipment, for use in a
Commercial or Light
Industrial Environment.
We the undersigned, hereby declare, under our sole responsibility, that the equipment packaged with
this notice conforms to the above directives.
Manufacturer Legal Representative in Europe
Mr. Ronald Fotino Mr. J. Solari
The 9F120-08, 9F122-12 and 9F125-08 are Class 1 Laser Products
CLASS 1 LASER TRANSCEIVERS
CLASS 1
LASER PRODUCT
The 9F120-08, 9F122-12 and 9F125-08 use Class 1 Laser transceivers.
Read the following safety information before installing or operating these
adapters.
The Class 1 laser transceivers use an optical feedback loop to maintain Class 1 operation
limits. This control loop eliminates the need for maintenance checks or adjustments. The
output is factory set, and does not allow any user adjustment. Class 1 Laser transceivers
comply with the following safety standards:
• 21 CFR 1040.10 and 1040.11 U.S. Department of Health and
Human Services (FDA).
• IEC Publication 825 (International Electrotechnical Commission).
• CENELEC EN 60825 (European Committee for Electrotechnical
Standardization).
When operating within their performance limitations, laser transceiver output meets the
Class 1 accessible emission limit of all three standards. Class 1 levels of laser radiation are not
considered hazardous.
Link Distance................................................................................................................. 5-2
v
Contents
vi
Introduction
The 9F120-08, 9F122-12 and 9F125-08 MicroLAN™ Modules are Dual Attached
Concentrator modules for the SmartSwitch 9000 (see Figure 1-1). The 9F120-08
provides eight multi-mode fiber Master ports, the 9F122-12 provides twelve
unshielded twisted pair Master ports, and the 9F125-08 provides eight single
mode fiber Master ports. All allow connections of Single or Dual Attached
Stations. The 9F120-08, 9F122-12 and 9F125-08 are ANSI FDDI-compliant with
SMT (version 7.3), MAC, PHY, and PMD. These modules attach directly to the
SmartSwitch 9000 FNB backplane, delivering up to 400 Mbps of bandwidth. The
modules use the Intel i960 microprocessor for all SMT and local/remote SNMP
management functions.
Chapter 1
Features
Processor
The concentrator modules are equipped with an advanced Intel i960
microprocessor. This microprocessor provides a platform for all management
functions within a scalable RISC-based architecture.
Management
Management features include the following:
•Module insert/bypass control
•MAC placement
•MAC level and network level statistics
•An FDDI station list
•Individual Master port assignments
1-1
Loading...
+ 19 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.