Cabletron Systems MMAC-Plus 9A128-01, MMAC-Plus 9A129-01 User Manual

Page 1
MMAC-Plus
ATM Access Module
9A128-01 & 9A129-01
User’s Guide
Page 2
i
Notice
Notice
Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made.
The hardware, firmware, or software described in this manual is subject to change without notice.
IN NO EVENT SHALL CABLETRON SYSTEMS BE LIABLE FOR ANY INCIDENTAL, INDIRECT, SPECIAL, OR CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING BUT NOT LIMITED TO LOST PROFITS) ARISING OUT OF OR RELATED TO THIS MANUAL OR THE INFORMATION CONTAINED IN IT, EVEN IF CABLETRON SYSTEMS HAS BEEN ADVISED OF, KNOWN, OR SHOULD HAVE KNOWN, THE POSSIBILITY OF SUCH DAMAGES.
© Copyright May 1995 by:
Cabletron Systems, Inc. 35 Industrial Way Rochester, NH 03867-0505
All Rights Reserved Printed in the United States of America
Order Number: 9031304-01 May 95
LANVIEW is a registered trademark of Cabletron Systems, Inc. MMAC-Plus is a trademark of Cabletron Systems, Inc. CompuServe is a registered trademark of CompuServe, Inc.
Page 3
ii
Notice
FCC Notice
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment uses, generates, and can radiate radio frequency energy and if not installed in accordance with the operator’s manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause interference in which case the user will be required to correct the interference at his own expense.
WARNING: Changes or modifications made to this device which are not expressly approved by the
party responsible for compliance could void the user’s authority to operate the equipment.
VCCI Notice
This equipment is in the 1st Class Category (information equipment to be used in commercial and/or industrial areas) and conforms to the standards set by the Voluntary Control Council for Interference by Information Technology Equipment (VCCI) aimed at preventing radio interference in commercial and/or industrial areas.
Consequently, when used in a residential area or in an adjacent area thereto, radio interference may be caused to radios and TV receivers, etc.
Read the instructions for correct handling.
Page 4
Notice
DOC Notice
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
iii
Page 5
Safety Notice
Safety Information
CLASS 1 LASER TRANSCEIVERS
The 9A129-01 is a Class 1 Laser Product
CLASS 1 LASER PRODUCT
The 9A129-01 uses Class 1 Laser transceivers. Read the f ollo wing saf ety
information before installing or operating these adapters.
The Class 1 laser transceivers use an optical feedback loop to maintain Class 1 operation limits. This control loop eliminates the need for maintenance checks or adjustments. The output is factory set, and does not allow any user adjustment. Class 1 Laser transceivers comply with the following safety standards:
21 CFR 1040.10 and 1040.11 U.S. Department of Health and Human Services (FDA).
IEC Publication 825 (International Electrotechnical Commission).
CENELEC EN 60825 (European Committee for Electrotechnical Standardization).
When operating within their performance limitations, laser transceiver output meets the Class 1 accessible emission limit of all three standards. Class 1 levels of laser radiation are not considered hazardous.
iv
Page 6
Safety Information
CLASS 1 LASER TRANSCEIVERS
Laser Radiation and Connectors
Safety Notice
When the connector is in place, all laser radiation remains within the fiber. The maximum amount of radiant power exiting the fiber (under normal conditions) is -12.6 dBm or 55 x 10
-6
watts.
Removing the optical connector from the transceiver allows laser radiation to emit directly from the optical port. The maximum radiance from the optical port (under worst case conditions) is 0.8 W cm
-2
or 8 x 10
3
W m
2
sr-1.
Do not use optical instruments to view the laser output. The use of optical instruments to view laser output increases eye hazard. When viewing the output optical port, power must be removed from the network adapter.
v
Page 7
Chapter 1 Introduction
Features........................................................................................................................... 1-1
Related Manuals............................................................................................................ 1-4
Getting Help ..................................................................................................................1-4
Chapter 2 Installing the MMAC-Plus Modules
Contents
The Reset Switch ...........................................................................................................2-3
User-Accessible Components...................................................................................... 2-4
Setting the Module Card DIP Switch.........................................................................2-5
Chapter 3 Operation
ATM ................................................................................................................................ 3-1
Flexible Network Bus (FNB)........................................................................................ 3-2
System Management Buses .........................................................................................3-2
SMB-1 Bus............................................................................................................... 3-2
SMB-10 Bus............................................................................................................. 3-2
System Diagnostic Controller...................................................................................... 3-2
DC/DC Converter ........................................................................................................3-3
FNB Interface.................................................................................................................3-3
i960 Core......................................................................................................................... 3-3
Chapter 4 LANVIEW LEDs
Chapter 5 General Specifications
Safety............................................................................................................................... 5-1
Service............................................................................................................................. 5-1
Physical........................................................................................................................... 5-2
Dimensions ............................................................................................................. 5-2
Weight...................................................................................................................... 5-2
Temperature............................................................................................................ 5-2
Relative Humidity .................................................................................................5-2
v
Page 8
Introduction
The 9A128-01 and 9A129-01 ATM Access Modules (shown in Figure 1-1) provide an ATM Uplink that allows connecting an external ATM network to the MMAC-Plus.
Chapter 1
Features
The 9A128-01 and 9A129-01 are used to connect an external ATM network or workstation to one of the two FNB networks, FNB-1 or FNB-2, on the MMAC-Plus FNB backplane. External connections are made via a front panel, 155 Mbps SONET ATM interface.
The 9A128-01 and 9A129-01 are fully compatible with all ATM Forum specifications, including UNI 3.0, ILMI and LAN Emulation. The 9A128-01 and 9A129-01 act as a ATM Forum LAN Emulation Client, allowing Ethernet, Token Ring and FDDI users to access an ATM backbone.
Processor
The 9A128-01 and 9A129-01 are equipped with an advanced Intel i960 microprocessor. This microprocessor provides a platform for all management functions within a scalable RISC-based architecture.
System Management
The 9A128-01 and 9A129-01 interface to the two System Management Buses (SMB-1 and SMB-10) for intermodule management. Management features include the following:
Module Insert/Bypass Control
MAC Placement
Station Management (SMT) Statistics
Bridging Statistics (for all interfaces) including
- Frames Filtered
- Frames Forwarded
- All STA Parameters
1-1
Page 9
Introduction
Hardware Bridging Logic
Hardware frame filter/forward logic increases the bridging performance of the 9A128-01 and 9A129-01, allowing the modules to achieve higher throughputs (up to 20,000 packets per second).
Spanning T ree Algorithm
The 9A128-01 and 9A129-01 support both IEEE 802.1d and DEC Spanning Tree Algorithm (STA) protocols.
Connectivity
For ATM, the 9A128-01 uses a 155 Mbps SONET OC3 Multimode Fiber front panel interface and the 9A129-01 uses a single mode fiber interface. These have a SC type connector. In addition, the 9A128-01 and 9A129-01 have two physical FDDI interfaces (FNB-1, and FNB-2) and allows bridging one of these to the front panel interface.
LANVIEW LEDs
The 9A128-01 and 9A129-01 use LANVIEW: the Cabletron Systems built-in visual diagnostic and status monitoring system. With LANVIEW LEDs, you can quickly identify the device, port, and physical layer status at a glance.
Hot Swapping
The 9A128-01 and 9A129-01 can be installed or removed from the chassis while the MMAC-Plus is powered up without affecting the operation of the rest of the network.
1-2
Page 10
9A128-01
ATM
FNB
ATM
1
A T M
1
9A129-01
ATM
FNB
ATM
1
A T
M
1
Features
SMB
CPU
SMB
CPU
MMAC PLUS MMAC PLUS
Figure 1-1. The 9A128-01 and 9A129-01 Modules
1-3
Page 11
Introduction
Related Manuals
The manuals listed below should be used to supplement the procedures and technical data contained in this manual.
MMAC-Plus Installation Guide
MMAC-Plus Operations Guide
MMAC-Plus 9C300-1 Environmental Module User’s Guide
MMAC-Plus 9C214-1 AC Power Supply User’s Guide
MMAC-Plus Module Local Management User’s Guide
Getting Help
If you need additional support with the MMAC-Plus, or if you have any questions, comments or suggestions concerning this manual, feel free to contact Cabletron Systems Technical Support:
By phone: (603) 332-9400
By CompuServe
By Internet mail: support@ctron.com
By mail: Cabletron Systems, Inc.
®
: GO CTRON from any ! prompt
P.O. Box 5005 Rochester, NH 03867-0505
1-4
Page 12
Chapter 2
Installing the MMAC-Plus Modules
MMAC-Plus Modules can be installed in any of the 14 slots that are available. To install, follow the steps below:
1. Remove the blank panel, covering the slot in which the MMAC-Plus Module
will be installed. All other slots must remain covered to ensure proper airflow
and cooling.
2. Unpack the MMAC-Plus Module by carefully removing it from the shipping
box. (Save the box and packing materials in the event the module must be
reshipped.)
3. Attach one end of the ESD wrist strap packaged with the MMAC-Plus chassis
to your wrist. Plug the other end into the ESD Wrist Strap Grounding
receptacle in the lower right corner of the MMAC-Plus Chassis shown in
Figure 2-1.
4. Remove the MMAC-Plus Module from the plastic bag. (Save the bag in the
event the module must be reshipped.) Observe all precautions to prevent
damage from Electrostatic Discharge (ESD).
5. Examine the MMAC-Plus Module, carefully checking for damage. If any
damage exists, DO NOT install the module. Immediately contact Cabletron
Systems Technical Support.
6. Install the MMAC-Plus Module in the chassis by sliding it in any available
slot and locking down the top and bottom plastic tabs, as shown in Figure 2-1.
Take care that each module slides in straight and properly engages the
backplane connectors. When installing a module, ensure that the circuit card
is between the card guides, as shown in Figure 2-1. Check both the upper and
lower tracks.
2-1
Page 13
Installing the MMAC-Plus Modules
7
FLNK
8
FLNK
FLNK
10
RX
FLNK
INS
TX
11
RX
FLNK
INS
TX
12
RX
Metal Back-Panel
Figure 2-1. Installing the MMAC-Plus Module
Jack for ESD wrist strap
Circuit Card
Card Guides
2-2
Page 14
The Reset Switch
SMB
CPU
The Reset switch is located on the front panel, under the top plastic tab as shown in Figure 2-2. It serves two functions:
Pressing the Reset switch twice within three seconds causes the processor
(i960) to reset.
Pressing and holding the switch on for three or more seconds causes the
module to shutdown. Pressing and holding again for three seconds restarts the
module.
SNMP management may be used to disable this switch to enhance module security.
The Reset Switch
Reset Switch
Figure 2-2. The Reset Switch
2-3
Page 15
Installing the MMAC-Plus Modules
User-Accessible Components
Figure 2-4 shows the various components that are accessible to the user. These consist of an eight position dip switch (explained in the next section), replaceable PROMs, and sockets for RAM. These will be used for future upgrades. Instructions for installing the components will be supplied with the upgrade kit.
SMB-1 PROM
i960 Processor
DIP Switch
Local DRAM Socket
Shared DRAM Socket
Flash SIMM Socket
Boot PROM
2-4
Figure 2-3. User-Accessible Components
Page 16
Setting the Module Card DIP Switch
Setting the Module Card DIP Switch
An eight switch DIP switch is located on the module card as shown in Figure 2-4 and Figure 2-4. The functions of the switches are listed in Table 2-1.
1 2 3 4 5 6 7 8
Figure 2-4. Location of Module DIP Switch
2-5
Page 17
Installing the MMAC-Plus Modules
See the Cautions at the end of this table.
Table 2-1. Function of DIP Switch
Switch
8
7
6
5 Reserved For Factory Use Only
Function Description
When toggled, this switch clears user-entered
Clear
Password
Clear
NVRAM
Force BootP
Download
passwords stored in NVRAM and restores the
1
default passwords. Once reset you can use the defaults or enter new passwords.
The module uses NVRAM to store user­entered parameters such as IP addresses, device name, etc. To reset these parameters to the factory defaults, toggle this switch. Once
2
reset you can use the defaults or enter new parameters, which are stored in NVRAM when the module is powered down, and remain there until the switch is toggled again.
Toggling this switch after pulling the board out of the MMAC-Plus clears download information from NVRAM and forces image files to be downloaded from the station configured to act as that module’s BootP server.
2-6
!
CAUTION
4 Reserved For Factory Use Only
3 Reserved For Factory Use Only
2 Reserved For Factory Use Only
1 Reserved For Factory Use Only
1. Caution: Do not toggle Switch 8 unless you intend to reset the user­configured passwords to their factory default settings.
2. Caution: Do not toggle Switch 7 unless you intend to reset the user parameters to the factory default settings.
Page 18
Operation
The 9A128-01 and 9A129-01 provide bridging between the front panel SONET ATM interface and one of the FDDI rings on the FNB backplane (FNB-1 or FNB-2) as shown in Figure 3-1. The factory default configuration is bridging between the front panel and FNB-1.
Chapter 3
ATM
DC/DC
Converter
SONET
ATM
Interface
Figure 3-1. 9A128-01 and 9A129-01 Block Diagram
The 9A128-01 and 9A129-01 use a 155 Mbps SONET OC3 Fiber front panel interface. The 9A128-01 is for multi-mode fiber and the 9A129-01 is for single-mode fiber. The 9A128-01 and 9A129-01 are fully compatible with all ATM Forum specifications, including UNI 3.0, ILMI and LAN Emulation. The 9A128-01 and 9A129-01 act as an ATM Forum LAN Emulation Client, allowing Ethernet Token Ring and FDDI users to access an ATM backbone.
System
Diagnostic
Controller
i960 PLUS Core
SMB-1
SMB-10
FNB-1 or
FNB-2
3-1
Page 19
Operation
Flexible Network Bus (FNB)
The FNB consists of two dual FDDI networks, FNB-1 and FNB-2, providing up to 400 Mbps of data bandwidth. These FDDI networks are 100% ANSI FDDI-compliant supporting SMT (version 7.3), MAC, PHY, and PMD standards. This allows the FNB to traverse multiple MMAC-Plus systems, or connect to any ANSI FDDI-compliant device, through standard A/B port connections.
System Management Buses
There are two management channels within the MMAC-Plus system: the SMB-1 and the SMB-10. These buses provide out-of-band management and inter-module management communication.
SMB-1 Bus
SMB-10 Bus
The SMB-1 is a 1 Mbps management bus located within the MMAC-Plus. This bus is utilized by all diagnostic controllers in the system including connectivity modules, power supply modules and the environmental module. The SMB-1 transports inter-chassis information between system components, such as power and environmental information, as well as diagnostic messages. Periodic loop-back tests are performed by all modules that share this bus to ensure the validity of SMB-1. In the event a failure is detected on SMB-1, the SMB-10 may be used as an alternate communication channel.
The SMB-10 is a 10 Mpbs management bus located within the MMAC-Plus which is also used for inter-chassis communication of modules, as well as serving as an out-of-band management channel into the MMAC-Plus. The SMB-10 is externalized from the chassis via an optional Ethernet Port Interface Module (EPIM) located on the front of the Environmental Module. Through an EPIM connection, full SNMP management of the MMAC-Plus is available out-of-band from user data. Modules that share the SMB-10 bus periodically send out loop­back packets to ensure the validity of SMB-10. In the event a fault is detected on the SMB-10, the SMB-1 can be used as an alternate communication channel by the modules.
3-2
Page 20
System Diagnostic Controller
This diagnostic controller is composed of a Z-80 microprocessor and its supporting logic. The diagnostic controller is designed to control the power-up sequencing of modules, monitor the 9A128-01 and 9A129-01 input and output power parameters, keep watch over the main host processor, as well as monitor the temperature and control the SMB LANVIEW diagnostic LED. Although the diagnostic controller and the main host processor can operate independently of each other if needed, they exchange information about each other’s status and overall module condition. The information gathered by the diagnostic controller is available to the network manager via local/remote management and the LCD located on the environment module. The 9A128-01 and 9A129-01 have been designed so that in the event of a diagnostic controller fault, the modules continue to function.
System Diagnostic Controller
DC/DC Converter
The DC/DC converter converts the 48 VDC on the system power bus to the necessary operating voltages for its host network services module. The diagnostic controller controls the operation of the DC/DC converter.
FNB Interface
MMAC-Plus modules are designed with one of two attachment policies. One allows dual attachment of a module to either FNB-1 or FNB-2; the second allows dual attachment to both FNB-1 and FNB-2. The 9A128-01 and 9A129-01 have two dual attachments to the FNB backplane, connecting to either FNB-1 or FNB-2. The module can insert into the FNB or bypass it. These flexible configuration options make the MMAC-Plus ideal for networks designed to Bridge/Route multiple lower speed LANs to FDDI and/or networks designed using an FDDI collapsed backbone.
i960 Core
The i960 core in the FNB module serves two major functions: it provides the packet forwarding logic and performs all network management services. FNB modules can be configured to run as layer 2 bridges, layer 3 routers or as SecureFast options concurrently, but the SFPS option cannot run with bridging and routing.
Packet Switches. It is possible to run the bridging and routing
The i960 core provides the SNMP protocol stacks, as well as support for industry standard MIBs. Additionally, Cabletron enterprise extension MIBs are supported for each media type. Advanced management services, such as the Distributed LAN Monitor, RMON, telnet, and network address to MAC address mapping, are also provided by the i960 core.
3-3
Page 21
LANVIEW LEDs
ATM
FNB
SMB
CPU
ATM
1
A T
M
The front panel LANVIEW LEDs indicate the status of the module and may be used as an aid in troubleshooting. Shown in Figure 4-1 are the LANVIEW LEDs of the 9A128-01 and 9A129-01 modules.
Chapter 4
System Status
FNB Receive
ATM Receive
ATM Link
Figure 4-1. 9A128-01 and 9A129-01 LANVIEW LEDs
FNB Transmit
ATM T ransmit
ATM Status
4-1
Page 22
LANVIEW LEDs
The functions of the System Management Bus (SMB) and CPU LEDs are listed in Table 4-1.
Table 4-1. SMB and CPU LEDs
LED Color
State Description
Green Functional Fully operational
Yellow Crippled Not fully operational (i.e., one bad port)
Yellow/Green Booting Blinks yellow and green while booting
Red Reset Normal power-up reset
Red (Flashing) Failed Fatal error has occurred
Off Power off Module powered off
The function of the FNB Receive LEDs is listed in Table 4-2.
Table 4-2. FNB Receive LEDs
LED Color
State
Yellow (Flashing) Activity
Off No Activity
4-2
The function of the FNB Transmit LEDs is listed in Table 4-2.
Table 4-3. FNB Transmit LEDs
LED Color
State
Green (Flashing) Activity
Off No Activity
Page 23
The function of the ATM Receive LED is listed in Table 4-2.
Table 4-4. ATM Receive LEDs
LANVIEW LEDs
LED Color
State
Yellow (Flashing) Activity
Off No Activity
The function of the ATM Transmit LED is listed in Table 4-2.
Table 4-5. ATM Transmit LEDs
LED Color
State
Green (Flashing) Activity
Off No Activity
The function of the ATM Link LED is listed in Table 4-1.
Table 4-6. ATM Link LEDs
LED Color
Link
Green Link
Off No Link
The function of the ATM Status LEDs is listed in Table 4-1.
Table 4-7. ATM Status LEDs
LED Color
Status
Green Port Enabled and OK
Yellow Standby
Red Port Enabled and Error
Off -
4-3
Page 24
General Specifications
The specifications of the 9A128-01 and 9A129-01 ATM Access Module are as follows:
Chapter 5
Safety
CAUTION
It is the responsibility of the person who sells the system to which the module will
!
be a part to ensure that the total system meets allowed limits of conducted and radiated emissions.
This equipment meets the following safety requirements:
UL 1950
CSA C22.2 No. 950
EN 60950
IEC 950
EMI Requirements of FCC Part 15 Class A
EN 55022 Class A
VCCI Class I
EMC the following requirements:
EN 50082-1 IEC 801-2 ESD IEC 801-3 Radiated susceptibility IEC 801-4 EFT
Service
MTBF (MHBK-217E): >200,000 hrs.
MTTR: <0.5 hr.
5-1
Page 25
General Specifications
Physical
Dimensions:
35.0 D x 44.0 H x 3.0 W centimeters (13.8 D x 17.4 H x 1.2 W inches)
Weight:
Unit: 1.36 kg. (3 lb)
Shipping: 1.81 kg. (4 lb)
Temperature:
Operating Temp: 5 to 40° C Storage Temp: -30 to 90° C
Relative Humidity:
5% to 95% non-condensing
5-2