Cabletron Systems 36, FOMIM-32, FOMIM-36, FOMIM-38 User Manual

Page 1
FOMIM-32/36/38 FIBER OPTIC
MEDIA INTERFACE MODULE
USER’S GUIDE
Page 2
Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made.
The hardware, firmware, or software described in this manual is subject to change without notice. IN NO EVENT SHALL CABLETRON SYSTEMS BE LIABLE FOR ANY INCIDENTAL,
INDIRECT, SPECIAL, OR CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING BUT NOT LIMITED TO LOST PROFITS) ARISING OUT OF OR RELATED TO THIS MANUAL OR THE INFORMATION CONTAINED IN IT, EVEN IF CABLETRON SYSTEMS HAS BEEN ADVISED OF, KNOWN, OR SHOULD HAVE KNOWN, THE POSSIBILITY OF SUCH DAMAGES.
Copyright 1996 by Cabletron Systems, Inc., P.O. Box 5005, Rochester, NH 03866-5005 All Rights Reserved Printed in the United States of America
Order Number: 9030524-01 July 1996
SPECTRUM, LANVIEW, MicroMMAC Manager, EPIM, EPIM-A, EPIM-F1, EPIM-F2, EPIM-F3, EPIM-T, EPIM-X, FOMIM, FOT-F, FOT-F3, HubSTACK, SEH, SEHI
All other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies.
, and
, and
BRIM
TMS-3
are registered trademarks and
are trademarks of Cabletron Systems, Inc.
Element
FCC NOTICE
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE:
device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment uses, generates, and can radiate radio frequency energy and if not installed in accordance with the operator’s manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause interference in which case the user will be required to correct the interference at his own expense.
WARNING:
party responsible for compliance could void the user’s authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class A digital
Changes or modifications made to this device which are not expressly approved by the
FOMIM User’s Guide i
This document was created with FrameMaker 4.0.2
Printed on Recycled Paper
Page 3
Notice
DOC NOTICE
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
VCCI NOTICE
This equipment is in the 1st Class Category (information equipment to be used in commercial and/or industrial areas) and conforms to the standards set by the Voluntary Control Council for Interference by Information Technology Equipment (VCCI) aimed at preventing radio interference in commercial and/or industrial areas.
Consequently , when used in a residential area or in an adjacent area thereto, radio interference may be caused to radios and TV receivers, etc.
Read the instructions for correct handling.
CABLETRON SYSTEMS, INC. PROGRAM LICENSE AGREEMENT
IMPORTANT:
This document is an agreement between you, the end user, and Cabletron Systems, Inc. (“Cabletron”) that sets forth your rights and obligations with respect to the Cabletron software program (the “Program”) contained in this package. The Program may be contained in firmware, chips or other media. BY UTILIZING THE ENCLOSED PRODUCT, YOU ARE AGREEING TO BECOME BOUND BY THE TERMS OF THIS AGREEMENT, WHICH INCLUDES THE LICENSE AND THE LIMITATION OF WARRANTY AND DISCLAIMER OF LIABILITY. IF YOU DO NOT AGREE TO THE TERMS OF THIS AGREEMENT, PROMPTLY RETURN THE UNUSED PRODUCT TO THE PLACE OF PURCHASE FOR A FULL REFUND.
Before utilizing this product, carefully read this License Agreement.
ii FOMIM User’s Guide
Page 4
CABLETRON SOFTWARE PROGRAM LICENSE
Notice
1. LICENSE
package subject to the terms and conditions of this License Agreement. You may not copy, reproduce or transmit any part of the Program except as permitted by the
Copyright Act of the United States or as authorized in writing by Cabletron.
2. OTHER RESTRICTIONS. You may not reverse engineer, decompile, or disassemble the
Program.
3. APPLICABLE LA W. This License Agreement shall be interpreted and governed under the laws
and in the state and federal courts of New Hampshire. You accept the personal jurisdiction and venue of the New Hampshire courts.
. You have the right to use only the one (1) copy of the Program provided in this
EXCLUSION OF WARRANTY AND DISCLAIMER OF LIABILITY
1. EXCLUSION OF
writing, Cabletron makes no warranty, expressed or implied, concerning the Program (including its documentation and media).
CABLETRON DISCLAIMS ALL WARRANTIES, OTHER THAN THOSE SUPPLIED TO YOU BY CABLETRON IN WRITING, EITHER EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WITH RESPECT TO THE PROGRAM, THE ACCOMP ANYING WRITTEN MATERIALS, AND ANY ACCOMPANYING HARDW ARE.
WARRANTY. Except as may be specifically provided by Cabletron in
2. NO LIABILITY FOR CONSEQUENTIAL DAMAGES. IN NO EVENT SHALL
CABLETRON OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS, PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION, SPECIAL, INCIDENTAL, CONSEQUENTIAL, OR RELIANCE DAMAGES, OR OTHER LOSS) ARISING OUT OF THE USE OR INABILITY TO USE THIS CABLETRON PRODUCT, EVEN IF CABLETRON HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. BECAUSE SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, OR ON THE DURATION OR LIMITATION OF IMPLIED WARRANTIES, IN SOME INSTANCES THE ABOVE LIMITATIONS AND EXCLUSIONS MAY NOT APPLY TO YOU.
UNITED STATES GOVERNMENT RESTRICTED RIGHTS
The enclosed product (a) was developed solely at private expense; (b) contains “restricted computer software” submitted with restricted rights in accordance with Section 52227-19 (a) through (d) of the Commercial Computer Software - Restricted Rights Clause and its successors, and (c) in all respects is proprietary data belonging to Cabletron and/or its suppliers.
For Department of Defense units, the product is licensed with “Restricted Rights” as defined in the DoD Supplement to the Federal Acquisition Regulations, Section 52.227-7013 (c) (1) (ii) and its successors, and use, duplication, disclosure by the Government is subject to restrictions as set forth in subparagraph (c) (1) (ii) of the Rights in Technical Data and Computer Software clause at
252.227-7013. Cabletron Systems, Inc., 35 Industrial Way, Rochester, New Hampshire 03867-0505.
FOMIM User’s Guide iii
Page 5
Notice
DECLARATION OF CONFORMITY
Application of Council Directive(s):
Manufacturer’s Name:
Manufacturer’s Address:
European Representative Name:
European Representative Address:
Conformance to Directive(s)/Product Standards:
Equipment T ype/Environment:
89/336/EEC 73/23/EEC
Cabletron Systems, Inc. 35 Industrial Way
PO Box 5005 Rochester, NH 03867
Mr. J. Solari Cabletron Systems Limited
Nexus House, Newbury Business Park London Road, Newbury Berkshire RG13 2PZ, England
EC Directive 89/336/EEC EC Directive 73/23/EEC EN 55022 EN 50082-1 EN 60950
Networking Equipment, for use in a Commercial or Light Environment.
Industrial
We the undersigned, hereby declare that the equipment packaged with this notice conforms to the above directives.
Manufacturer Legal Representative in Europe Mr. Richard Michaud Mr. J. Solari
___________________________________ ___________________________________
Full Name Full Name Manager of Engineering Services Managing Director - E.M.E.A.
___________________________________ ___________________________________
Title Title Rochester, NH, USA Newbury, Berkshire, England
___________________________________ ___________________________________
Location Location
iv FOMIM User’s Guide
Page 6
CONTENTS
CHAPTER 1 INTRODUCTION
1.1 Using This Manual.......................................................................1-1
1.2 Document Conventions...............................................................1-3
1.3 Fiber Optic Media Interface Modules...........................................1-3
1.3.1 Distance and Cable Type ...............................................1-3
1.3.2 Multi Media Access Centers ........................................... 1-4
1.4 LANVIEW Status Monitoring System ..........................................1-4
1.5 Related Manuals..........................................................................1-6
1.6 Getting Help.................................................................................1-6
CHAPTER 2 NETWORK REQUIREMENTS AND INSTALLATION
2.1 Network Cable Requirements......................................................2-1
2.1.1 Fiber Optic Network Design Guidelines..........................2-1
2.2 Unpacking the FOMIM.................................................................2-2
2.3 Installing the FOMIM into the MMAC...........................................2-3
2.4 Connecting Fiber Optic Cabling to the FOMIM............................2-4
CHAPTER 3 TESTING AND TROUBLESHOOTING
3.1 Installation Test ...........................................................................3-1
3.1.1 Testing the Fiber Optic Link Segment ............................3-1
3.1.2 Link Test ......................................................................... 3-2
3.2 Pre-Installation Test.....................................................................3-3
3.3 Using LANVIEW..........................................................................3-4
APPENDIX A FOMIM SPECIFICATIONS
INDEX
FOMIM User’s Guide v
Page 7
Contents
vi FOMIM User’s Guide
Page 8
CHAPTER 1
INTRODUCTION
Welcome to the Cabletron Systems
Media Interface Module User’s Guide
to serve as a simple installation and reference guide for the FOMIM, and to explain the capabilities and special features of the module. Before using the FOMIM, you need to carefully read through this manual to gain a full understanding of the FOMIM and its capabilities.
Cabletron Systems offers three versions of 1300 nm single mode Fiber Optic Media Interface Modules:
FOMIM-32 providing 12 links with ST type connectors
FOMIM-36 providing 6 links with ST type connectors
FOMIM-38 providing 18 links with ST type connectors
FOMIM-32/36/38 Fiber Optic
. We have designed this manual
1.1 USING THIS MANUAL
Chapter 1, the Cabletron Systems FOMIMs (Figure 1-1). This chapter also includes a list of related manuals.
Introduction
, discusses the capabilities and special features of
Chapter 2, network requirements that must be met before you install the FOMIM and instructions for installing the FOMIM into the MMAC chassis.
Chapter 3, and troubleshooting the installation of the FOMIM. Instructions for using LANVIEW, Cabletron Systems built-in visual diagnostic and status monitoring system, are also included.
Appendix A, and environmental requirements for the FOMIM.
FOMIM User’s Guide 1-1
Network Requirements and Installation
Testing and Troubleshooting
FOMIM Specifications
, provides procedures for testing
, contains operational specifications
, contains a list of
Page 9
Chapter 1:
Introduction
It is assumed that you have a general working knowledge of Ethernet or IEEE 802.3 type data communications networks and their physical layer components.
1-2 FOMIM User’s Guide
Figure 1-1 The FOMIMs
Page 10
Document Conventions
1.2 DOCUMENT CONVENTIONS
The following conventions are used throughout this document:
Note
symbol. Calls the reader’s attention to any item of
NOTE
information that may be of special importance.
!
CAUTION
Caution
damage to the equipment.
Warning
equipment damage, personal injury or death.
symbol. Contains information essential to avoid
symbol. Warns against an action that could result in
1.3 FIBER OPTIC MEDIA INTERFACE MODULES
Cabletron Systems Fiber Optic Media Interface Modules provide a choice of six, twelve, or eighteen ports with ST connectors.
The FOMIM-32/36/38 use 1300 nm wavelength transmitters
NOTE
and receivers (not the 850 nm specified by FOIRL) and should be used only with the Cabletron Systems Ethernet single mode transceiver, the FOT-F3.
1.3.1 Distance and Cable Type
The FOMIMs support single mode fiber optic cable for sizes such as
µ
8.3/125 cable distance is dependent on the cable type and the overall system fiber optic budget. If the system budgets and timing constraints are met, then a distance of up to 5 kilometers is possible. You can also use 62.5/125 multimode cable with the FOMIM, but due to greater optical loss, signal distance is reduced to 2 km.
FOMIM User’s Guide 1-3
m, 8.7/125 µm, 9/125 µm, 10/125 µm, and 12/125 µm. The
µ
m
Page 11
Chapter 1:
Introduction
1.3.2 Multi Media Access Centers
The Cabletron Systems Fiber Optic Media Interface Modules are designed to be installed into the Cabletron Systems Multi Media Access Center (MMAC). The modular design of the MMAC allows the FOMIM to co-exist with other Media Interface Modules (MIMs) to provide a variety of different media connections on any one point.
Each packet entering the FOMIM is repeated by the repeater module in the MMAC. Each packet that enters the repeater module is regenerated and retimed, which assures data integrity and maximum data path distance. In addition, the repeater feature ensures fault isolation, because the repeater module automatically segments problem ports from the network. A segmented port automatically reconnects to the network once the port receives a good packet.
The repeater module also allows you to access the network management capabilities that enable you to control the FOMIM and its attached segments. For example, information on the number of good packets and collisions that have passed through the FOMIM and each port on the MIM can be gathered. For more information on managing the FOMIM, refer to your specific management module Local Management Guide.
1.4 LANVIEW STATUS MONITORING SYSTEM
The FOMIM uses Cabletron Systems built-in visual diagnostic and status monitoring system, LANVIEW. Using LANVIEW, network troubleshooting personnel can quickly scan the LANVIEW LEDs to observe network status, diagnose network problems, and determine which node or segment is faulty (see Figure 1-2).
1-4 FOMIM User’s Guide
Page 12
LANVIEW Status Monitoring System
LANVIEW LEDs
Figure 1-2 LANVIEW LEDs
The following discusses the function of each LANVIEW LED on the FOMIM (Figure 1-2). Note that there is one Link OK (LNK) and one Receive (RCV) LED for each port on the MIM, as well as one Error (ERR) and one Collision (CLN) LED for the entire MIM.
Link OK (LNK) LED
When lit, this green LED indicates that a link has been established between the receive circuitry of the FOMIM and the transmit circuitry of the fiber optic device at the other end of the link segment. This LED remains lit as long as the link is maintained.
Receive (RCV) LED
When lit, this yellow LED indicates that a data packet is being received on that port. The flash of the LED is pulse stretched for viewing effect.
Collision (CLN) LED
When lit, this red LED indicates that a collision is occurring on one of the fiber segments attached to a fiber optic port on the FOMIM. The flash of the LED is pulse stretched for viewing effect.
FOMIM User’s Guide 1-5
Page 13
Chapter 1:
Error (ERR) LED
Introduction
When lit, this red LED indicates the temperature within the MMAC
°
chassis has risen to 40
C or greater. The FOMIM alerts the management
board, and the FOMIM in turn receives a signal to light the LED.
1.5 RELATED MANUALS
The manuals listed below should be used to supplement the procedures and other technical data provided in this manual. The procedures contained in these manuals will be referenced, rather than repeated, in this manual.
Cabletron Systems
MMAC-M5FNB, and MMAC-M8FNB) Overview and Set Up Guides
Cabletron Systems
Multi Media Access Center (MMAC-M3FNB,
.
FOT-F3 Fiber Optic Transceiver User's Manual.
1.6 GETTING HELP
If you need additional support related to this device, or if you have any questions, comments, or suggestions concerning this manual, contact Cabletron Systems Technical Support:
By phone (603) 332-9400
A.M
Monday – Friday; 8 By CompuServe GO CTRON from any ! prompt By Internet mail support@ctron.com By FTP ctron.com (134.141.197.25)
Login Password
anonymous
your email address
. – 8 P.M. Eastern T ime
Before calling Cabletron Systems Technical Support, have the following information ready:
A description of the failure
A description of any action(s) already taken to resolve the problem
(e.g., changing mode switches, rebooting the unit, etc.)
A description of your network environment (layout, cable type, etc.)
Network load and frame size at the time of trouble (if known)
1-6 FOMIM User’s Guide
Page 14
Getting Help
The serial and revision numbers of all Cabletron Systems products in the network
The device history (i.e., have you returned the device before, is this a recurring problem, etc.)
Any previous Return Material Authorization (RMA) numbers
FOMIM User’s Guide 1-7
Page 15
Chapter 1:
Introduction
1-8 FOMIM User’s Guide
Page 16
CHAPTER 2
NETWORK REQUIREMENTS AND
INSTALLATION
This chapter begins with network design guidelines in Section 2.1,
Network Cable Requirements
module in a network. It then provides instructions for installing the Cabletron Systems Fiber Optic Media Interface Module into the MMAC family of modular hubs.
2.1 NETWORK CABLE REQUIREMENTS
When connecting fiber optic segments to the FOMIM, you must follow the network guidelines listed below. Failure to do so may result in unsatisfactory network performance.
, that must be met before installing the
2.1.1 Fiber Optic Network Design Guidelines
The fiber optic link segment should consist of 8/125 – 12/125 µm
µ
single mode fiber optic cabling. You can also use 62.5/125 multimode cable with the FOMIM. However, optical loss will be greater with multimode cable and distances will be limited to 2 km.
The fiber optic cable must be tested with a fiber optic attenuation test set that is adjusted for a 1300 nm wave length. This test verifies that the signal loss in a cable is within an acceptable level of 9.0 dB or less for any given single mode fiber optic link.
When determining the maximum fiber optic cable length, the fiber optic budget (total loss of 9.0 dB or less between stations) and total network propagation delay should be calculated and considered before fiber runs are incorporated in any network.
Fiber optic budget is the combination of the optical loss due to the fiber optic cable, in-line splices, and fiber optic connectors (the loss for each splice and connector is typically 1 dB or less).
m
FOMIM User’s Guide 2-1
Page 17
Chapter 2:
Network Requirements and Installation
Propagation delay is the amount of time it takes a packet to travel from the sending device to the receiving device. Total propagation delay
µ
allowed for the entire network is 25.6
s. If the total propagation delay
between any two nodes on the network exceeds 25.6 µs, then bridges should be used.
When using single mode fiber optic cable, segment lengths up to 5 km are possible if system budgets are met.
2.2 UNPACKING THE FOMIM
Unpack the module as follows:
The module is very sensitive to static discharge. Observe all
!
CAUTION
electrostatic precautions while handling the FOMIM.
1. Remove the shipping material covering the FOMIM in the shipping box.
2. Verify the contents of the shipping box. The box, as packed should contain one FOMIM, one grounding strap, and one user’s guide.
3. Carefully remove the FOMIM from the shipping box. Leave the module in its conductive bag until you are ready to install it. Save the shipping box and materials in the event the unit has to be reshipped.
4. Visually inspect the module within the nonconductive bag. If you see any damage, contact Cabletron Systems Technical Support immediately.
2-2 FOMIM User’s Guide
Page 18
Installing the FOMIM into the MMAC
2.3 INSTALLING THE FOMIM INTO THE MMAC
You can easily install the FOMIM into a Multi Media Access Center with a Flexible Network Bus (MMAC-FNB). Install the FOMIM into the MMAC as follows:
1. Power down the MMAC hub.
2. Remove any chassis safety bars present on the front of the MMAC
hub.
3. Slide the FOMIM (Figure 2-1) into the card cage of the MMAC hub.
Be sure that the card is properly aligned in the top and bottom slots of the card cage.
Slot 1 of the MMAC hub is reserved f or a management module
NOTE
(e.g., IRM3) only.
4. Firmly press the module connections into the backplane. Do not force
the module into place or use the knurled knobs to draw the module into place.
5. Screw in the knurled knobs to secure the module to the MMAC.
6. Reinstall any chassis safety bars that were present on the MMAC.
FOMIM
MMAC-8FNB
FOMIM User’s Guide 2-3
Figure 2-1 Installing the FOMIM
Page 19
Chapter 2: Network Requirements and Installation
2.4 CONNECTING FIBER OPTIC CABLING TO THE
FOMIM
Each fiber optic link consists of two strands of fiber optic cabling: the transmit (TX) and the receive (RX). The transmit strand from a module port connects to the receive port of a fiber optic Ethernet device at the other end of the segment. The receive strand of the applicable port on the module connects to the transmit port of the fiber optic Ethernet device.
Cabletron Systems recommends labeling fiber optic cables to indicate receive and transmit ends. Many cables are prelabeled, providing matching labels or tapes at both ends of each strand of cable.
1. Remove the protective plastic covers from the fiber optic ports on the applicable port on the module, and from the ends of the connectors on each fiber strand.
Do not touch the ends of the fiber optic strands, and do not let
!
CAUTION
the ends come in contact with dust, dirt, or other contaminants. Contamination of the ends can cause problems in data transmissions. If the ends become contaminated, clean them with denatured alcohol using a soft, clean, lint free cloth.
2. Attach one fiber to the applicable receive port on the module. Insert the ST connector into the port with the alignment slot on the connector clockwise to lock it down.
Figure 2-2 ST Connector Insertion
3. Attach the other fiber of the pair to the applicable transmit port on the module. Use the same procedure for insertion of the ST connector.
2-4 FOMIM User’s Guide
Page 20
Connecting Fiber Optic Cabling to the FOMIM
4. At the other end of the fiber optic cable, attach the fiber pair to the
transmit and receive ports of the device.
If link indicators are present for the fiber optic connection, check that they are ON. If an indicator is present but not ON, that port does not have a valid link. Perform each of the follo wing steps until you reach a resolution of the problem and achieve a link.
Check that the device at the other end of the link is ON.
V erify proper cross-o ver of the fiber strands. Try sw apping the transmit
and receive connections at only one end of the link.
Verify that the fiber connection meets the dB loss specifications
outlined in Appendix A, FOMIM Specifications.
If you are still unable to establish a link, attempt to make the connection between the devices with another fiber optic cable. If this is unsuccessful, contact Cabletron Systems Technical Support.
FOMIM User’s Guide 2-5
Page 21
Chapter 2: Network Requirements and Installation
2-6 FOMIM User’s Guide
Page 22
CHAPTER 3
TESTING AND TROUBLESHOOTING
This chapter lists the installation checkout procedures necessary to verify that the segments connected to your FOMIM are operating properly. The chapter concludes with a description of the LANVIEW LEDs and their use in troubleshooting physical layer network problems.
3.1 INSTALLATION T EST
This section contains procedures to test the following:
The fiber optic link segment to be attached to the FOMIM
The link between the FOMIM and the device attached to the other end
of the fiber optic link segment
The FOMIM itself
3.1.1 Testing the Fiber Optic Link Segment
Test the segment being attached to the FOMIM to verify that the cable meets the fiber budget specifications discussed in Appendix A. Using a fiber optic power meter set, test the link segment as follows:
Do not touch the ends of the fiber optic strands, and do not let
!
CAUTION
1. Attach a fiber optic jumper to the optical power meter. The meter
should be set at 1300 nm.
2. Attach a fiber optic jumper to the optical source unit. If the source unit
has multiple settings, it should be set at 1300 nm.
3. Using a barrel connector, connect the jumpers together.
the ends come in contact with dust, dirt, or other contaminants. Contamination of the ends can cause problems in data transmissions. If the ends become contaminated, clean them with denatured alcohol using a soft, clean, lint free cloth.
4. Following the instructions for the test set, test the jumpers to get a
reference level. Make a note of this reading.
FOMIM User’s Guide 3-1
Page 23
Chapter 3: Testing and Troubleshooting
5. Disconnect the jumpers from the barrel connector.
6. Using the jumper, attach the optical power meter to one end of one strand of the link segment.
7. Using the other jumper, attach the other end of the same strand to the optical source unit.
8. Note the reading on the optical power meter. This is your test level.
9. Subtract the reference level found in Step 4 from the test level to find your dB loss for the fiber optic link segment, i.e., dB loss = Test Level - Reference Level.
10. Verify that the reading on the receive unit falls within the range indicated by the Receive Sensitivity and Maximum Receive Input Power specifications listed in the Fiber Optic Interface section of Appendix A.
11. Repeat Steps 6 through 10 for the other strand in the link segment.
If the fiber optic link segment does not meet the specifications, it may be contaminated with dust, dirt, or other contaminants. Try cleaning the connection at each end of the cable with denatured alcohol, using a soft, clean, lint free cloth, then repeat the test.
If this does not work, contact Cabletron Systems technical support.
3.1.2 Link T est
To verify the physical link between your devices, check the LNK LEDs on your FOMIM and receiving de vice for the applicable port. If the LEDs are lit, the proper connection has been made.
If the LEDs are not lit, perform the following procedure, using a Cabletron Systems FOT-F3 Fiber Optic T ranscei ver at the other end of the cable.
1. Check that power is being supplied to both the FOMIM in the MMAC chassis and the device at the other end of the link.
2. Reverse the fiber optic cable ends at either the applicable port on the module or at the device.
3. Check if the LEDs are lit.
3-2 FOMIM User’s Guide
Page 24
Pre-Installation T est
4. If the LEDs are not lit, reverse the cable ends back to their original
positions, and contact Cabletron Systems Technical Support for assistance.
3.2 PRE-INSTALLATION T EST
Before installing the FOMIM in a live network, test the module in a controlled situation to ensure that it is repeating packets. With the FOMIM installed in an MMAC hub with a Repeater module (e.g., IRM3), this test can be performed with two workstations (Figure 3-1) by completing the following steps:
1. Install the FOMIM into an MMAC chassis with an IRM3.
The IRM3 must be installed in slot one of the MMAC chassis.
NOTE
2. Connect the first workstation to the IRM3 using either the AUI port,
(with a transceiver and an AUI cable), or to the fiber optic port, (with fiber optic cable), depending on which is the active repeater port.
The AUI port is the default active repeater port on the IRM3. If
NOTE
you want to test the module using the fiber port, it must be selected through Local Management. Refer to the Local Management section of the IRM3 User’s Guide for more information on selecting the active repeater port.
3. Connect the second workstation to the FOMIM, using the appropriate
transceivers and cable.
4. Set the first workstation as the file server and the second as the client
(refer to the workstation documentation for setting up the workstations as file server and client). When the workstations are properly set up, proceed to send packets between the workstations and verify that the FOMIM is operating properly.
FOMIM User’s Guide 3-3
Page 25
Chapter 3: Testing and Troubleshooting
A “ping” test will verify that the module is operating properly.
NOTE
However, both server and client workstations must have their own unique IP Addresses.
If failures occur, refer to Section 3.3, Using LANVIEW, in this chapter.
MMAC-M3FNB with IRM3
File Server Workstation
0494109
Client Workstation
Figure 3-1 Pre-Installation Test
3.3 USING LANVIEW
The FOMIM uses Cabletron Systems built-in visual diagnostic and status monitoring system called LANVIEW. With LANVIEW, network troubleshooting personnel can quickly scan LEDs to observe network status, or diagnose network problems. Figure 1-2 in Chapter 1 shows the location of the LANVIEW LEDs.
3-4 FOMIM User’s Guide
Page 26
Table 3-1 LANVIEW Troubleshooting
Led Color Description
Using LANVIEW
Error Condition/Recommended Action
LNK (Link/ Fiber Port)
RCV (Receive)
CLN (Collision Present)
Green When on, a link is
established between the FOMIM Fiber port and the fiber device at the other end of the segment. LED is on as long as the link is maintained.
Yellow When flashing the
FOMIM is receiving data packets from segments connected to the associated port.
Red When flashing, a
collision is being detected on one or more segments connected to the MMAC. Note that periodic flashing is normal.
If off, the link between the port and fiber device has been broken.
Check the connectors at each end of the segment to ensure that they are free of dust. Clean the connectors if necessary. Reconnect the segment and check the Link LED again.
If off, the FOMIM is not receiving packets.
Check that the module is firmly installed in the MMAC.
Excessive flashing or on solid indicates excessive collisions.
ERR (Error)
Red Remains lit when the
If you are not able to resolve a problem with your FOMIM, call Cabletron Systems Technical Support for assistance (see Chapter 1, Section 1.6, Getting Help).
FOMIM User’s Guide 3-5
temperature within the MMAC chassis rises above 40°C.
Page 27
Chapter 3: Testing and Troubleshooting
3-6 FOMIM User’s Guide
Page 28
APPENDIX A
FOMIM SPECIFICATIONS
The operating specifications for the Cabletron Systems FOMIM are included in this Appendix. Cabletron Systems reserves the right to change these specifications at any time without notice.
A.1 OPERATING SPECIFICATIONS
Table A-1 Fiber Optic Interface (All Ports) Transceiver Built-In Cabletron Systems FOT-F3 Parameter Typical Minimum Maximum
Receive Sensitivity -31.0 dBm -36.0 dBm -30.0 dBm Max. Receive Input
Power Transmitter Power at
25°C Into 8.3/125 µm fiber:
Output Power Coefficient
Transmitter Power decreases as temperatures rise and
NOTE
increases as temperatures fall. Use the Output Power Coefficient to calculate increased or decreased power output for your operating environment. For example, the typical power output at 25° C is -16.4 dBm. For a 4° C temperature increase, multiply the typical coefficient (-0.07 dB) by four and add the result to the typical output power (4°C x -0.07 dB/°C) + (-16.4dBm) = -16.7).
-14.0 dBm
-18.0 dBm -21.0 dBm -15.0 dBm
-0.07 dB/°C
FOMIM User’s Guide A-1
Page 29
Appendix A: FOMIM Specifications
Table A-2 Fiber Optic Interface (All Ports)
Parameter Typical Minimum Maximum
Transmitter Peak W a ve Length
Spectral Width 95 nm 125 nm Rise Time 3.0 ns 2.7 ns 5.0 ns Fall Time 2.5 ns 2.2 ns 5.0 ns Duty Cycle 50.1% 49.6% 50.7%
1310 nm 1265 nm 1380 nm
Bit Error Rate Better than 10
-10
The transmitter power levels given above are Peak Power
NOTES
Levels after optical overshoot. You must use a Peak Power Meter to correctly compare the values given above to those measured on any particular port.
If you are measuring power levels with an Average Power Meter, add 3 dBm to the average power measurement to compare the measured average power values to the values listed above (i.e ., -33.5 dBm average + 3 dB = -30.5 dBm peak).
A.2 ENVIRONMENTAL REQUIREMENTS
Operating Temperature: +5° to +40°C (41° to 104°F) Non-operating Temperature: -30° to +80°C (-22° to 176°F) Operating Humidity: 5% to 95% (non-condensing)
A-2 FOMIM User’s Guide
Page 30
Agency Approvals
A.3 AGENCY APPROVALS
Designed in accordance with UL478, UL910, NEC 725-2(b), CSA, IEC, TUV, VDE Class A. Meets FCC Part 15, Class A limits.
It is the responsibility of the person who sells the system of which the FOMIM will be a part to ensure that the total system meets allowed limits of conducted and radiated emissions.
PHYSICAL PROPERTIES
Dimensions: 34.04 D x 29.21 H x 5.08 W cm
(13.4 D x 11.5 H x 2.0 W in)
Weight: FOMIM-36: 0.57 kg (1.25 lb)
FOMIM-32: 0.86 kg (1.90 lb) FOMIM-38: 1.13 kg (2.50 lb)
FOMIM User’s Guide A-3
Page 31
Appendix A: FOMIM Specifications
A-4 FOMIM User’s Guide
Page 32
INDEX
C
Cable
connecting 2-4 distance 1-3
requirements 2-1 CLN LED 1-5 Conventions 1-3
D
Design guidelines 2-1
E
ERR LED 1-5
F
FOMIM
installing 2-3
specifications A-1
unpacking 2-2
S
ST connectors 2-5
T
Testing
pre-installation 3-3, 3-4
U
Using LANVIEW 3-4
H
Help 1-6
L
LANVIEW
location 1-4
troubleshooting 3-5 Link
testing 3-1 LNK LED 1-5
M
MMAC
description 1-3
R
RCV LED 1-5 Related manuals 1-5
FOMIM User’s Guide Index-1
Page 33
Index
Index-2 FOMIM User’s Guide
Loading...