Cabletron Systems CSX500 User Manual

CSX500 SETUP GUIDE

PRE-CONFIGURATION INFORMATION

Only qualified personnel should install the CSX500. This Setup Guide is intended for the experienced network equipment installer.
This Setup Guide describes the tools needed to configure the CyberSWITCH CSX500.
NOTE
the QuickSet CD. The HSIM-W84 is similar to the CSX500. The difference is that the HSIM-W84 is a module that is installed into a host device, while the CSX500 is a standalone unit. All other information pertaining to the device is the same.
For further details concerning the operation of the CSX500, refer to the HSIM-W84 documentation on
ENET
RX
TX
LAN
WAN BRANCH OFFICE CONCENTRATOR
LNK
STS
ROUTER/SWITCH/INVERSE MUX
T1-1 T1-2 T1-3 T1-4
LNK
STS
Figure 1 The CSX500

QuickSet CONFIGURATION SETUP

Tools needed

The following tools are required to configure the CSX500:
LNK
STS
TELCO
LNK
STS
ASYNC
CONSOLE
PWR
CPU
LNK
STS
Personal Computer (PC)
Read Me First!
instruction sheet (enclosed in the manual package)
QuickSet CD (located in the shipping box with your device)
NOTE
PN 9032534-03 Page 1 of 2
Cabletron Systems highly recommends using the QuickSet utility to configure the CSX500. Using the QuickSet CD will ensure a fast and correct installation. Using other methods may not produce correct or as efficient results as the QuickSet CD.
CSX500 Setup Guide
QuickSet Utility: Configuring the CSX500
Refer to the QuickSet QuickStart Guide located inside the QuickSet CD jewel case and follow the QuickSet procedure to configure the CSX500.
NOTE
Refer to the the QuickSet configuration using the QuickSet CD.
Read Me First!
instruction sheet enclosed with the device to ensure that your PC is ready for
Full or Half Duplex Configuration on the LAN Port
If the version of QuickSet that you are running does not have the button in QuickSet to change the duplex setting, use the following procedure.
The LAN port on the CSX500 is set to connect using half duplex by default. If a LAN connection is needed for full duplex, the CSX500 must be configured using Network Tools. Refer to the Cabletron Systems
User’s Guide for CSX200, CSX400, CSX400-DC, HSIM-W6, and HSIM-W84
to configure the CSX500 using
Network Tools. Use the following procedure to set the port to full duplex:
1. Use this OID to change the LAN port from the default of half duplex to full duplex: ctIf Duplex: 1.3.6.1.4.1.52.4.3.3.2.1.1.5
2. Set the OID string to 3 (full) in order to set the port to full duplex. Set the OID string to 2 (standard) for the port
to be set to half duplex speed.
NOTE
If the LAN connection required is half duplex, and the port is configured for full duplex, the connection may appear to work, but problems can occur on the network. To prevent data corruption, change the connection to the appropriate duplex setting.
If a bootp download is required at full duplex speed, an internal DIP switch must be accessed and switch 1 of the DIP switch set for the bootp to be successful. Refer to the Cabletron Systems
Management User’s Guide for CSX200, CSX400, CSX400-DC, HSIM-W6, and HSIM-W84
more information on the bootp download procedure.
Local Management
Local
for

GETTING HELP

For additional support, contact the Cabletron Systems Global Call Center:
World Wide Web http://www.cab letron.com/ Phone (603) 332-9400 Internet mail support@cabletron.com FTP ftp://ftp.cabletron.com/
Login Password
To send comments or suggestions concerning this document, contact the Cabletron Systems Technical Writing Department via the following email address: TechWriting@cabletron.com
Make sure to include the document Part Number in the email message.
Copyright 1998 by Cabletron Systems, Inc., P.O. Box 5005, Rochester, NH 03866-5005
All Rights Reserved. Printed in the United States of America.
Cabletron Systems
and
QuickSet
are registered trademarks, and SmartSwitch is a trademark of Cabletron Systems, Inc.
PN 9032534-03 Page 2 of 2
anonymous your email address
Loading...