Cabletron Systems reserves the right to make changes in specifications and other information
contained in this document without prior notice. The reader should in all cases consult Cabletron
Systems to determine whether any such changes have been made.
The hardware, firmware, or software described in this manual is subject to change without notice.
IN NO EVENT SHALL CABLETRON SYSTEMS BE LIABLE FOR ANY INCIDENTAL,
INDIRECT, SPECIAL, OR CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING BUT
NOT LIMITED TO LOST PROFITS) ARISING OUT OF OR RELATED TO THIS MANUAL OR
THE INFORMATION CONTAINED IN IT, EVEN IF CABLETRON SYSTEMS HAS BEEN
ADVISED OF, KNOWN, OR SHOULD HAVE KNOWN, THE POSSIBILITY OF SUCH
DAMAGES.
1998 by Cabletron Systems, Inc., P.O. Box 5005, Rochester, NH 03866-5005
All Rights Reserved
Printed in the United States of America
Order Number: 9032076-05 August 1998
Cabletron Systems
Inc.
All other product names mentioned in this manual may be trademarks or registered trademarks of
their respective companies.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
NOTE:
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial environment.
This equipment uses, generates, and can radiate radio frequency energy and if not installed in
accordance with the operator’s manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause interference in which case the user
will be required to correct the interference at his own expense.
WARNING:
party responsible for compliance could void the user’s authority to operate the equipment.
is a registered trademark and
SmartSwitch
is a trademark of Cabletron Systems,
FCC NOTICE
Changes or modifications made to this device which are not expressly approved by the
Printed onRecycled Paper
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guidei
Notice
INDUSTRY CANADA NOTICE
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital
apparatus set out in the Radio Interference Regulations of the Canadian Department of
Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables
aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique
édicté par le ministère des Communications du Canada.
VCCI NOTICE
This is a Class A product based on the standard of the Voluntary Control Council for Interference by
Information Technology Equipment (VCCI). If this equipment is used in a domestic environment,
radio disturbance may arise. When such trouble occurs, the user may be required to take corrective
actions.
CABLETRON SYSTEMS, INC. PROGRAM LICENSE AGREEMENT
IMPORTANT:
This document is an agreement between you, the end user, and Cabletron Systems, Inc. (“Cabletron”)
that sets forth your rights and obligations with respect to the Cabletron software program (the
“Program”) contained in this package. The Program may be contained in firmware, chips or other
media. BY UTILIZING THE ENCLOSED PRODUCT, YOU ARE AGREEING TO BECOME
BOUND BY THE TERMS OF THIS AGREEMENT, WHICH INCLUDES THE LICENSE AND
THE LIMITATION OF WARRANTY AND DISCLAIMER OF LIABILITY. IF YOU DO NOT
AGREE TO THE TERMS OF THIS AGREEMENT, PROMPTLY RETURN THE UNUSED
PRODUCT TO THE PLACE OF PURCHASE FOR A FULL REFUND.
Before utilizing this product, carefully read this License Agreement.
ii6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Notice
CABLETRON SOFTWARE PROGRAM LICENSE
1.LICENSE
package subject to the terms and conditions of this License Agreement.
You may not copy, reproduce or transmit any part of the Program except as permitted by the
Copyright Act of the United States or as authorized in writing by Cabletron.
2.OTHER RESTRICTIONS. You may not reverse engineer, decompile, or disassemble the
Program.
3.APPLICABLE LA W. This License Agreement shall be interpreted and governed under the laws
and in the state and federal courts of New Hampshire. You accept the personal jurisdiction and
venue of the New Hampshire courts.
. You have the right to use only the one (1) copy of the Program provided in this
EXCLUSION OF WARRANTY AND DISCLAIMER OF LIABILITY
1.EXCLUSION OF
writing, Cabletron makes no warranty, expressed or implied, concerning the Program (including
its documentation and media).
CABLETRON DISCLAIMS ALL WARRANTIES, OTHER THAN THOSE SUPPLIED TO
YOU BY CABLETRON IN WRITING, EITHER EXPRESSED OR IMPLIED, INCLUDING
BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE, WITH RESPECT TO THE PROGRAM, THE
ACCOMP ANYING WRITTEN MA TERIALS, AND ANY A CCOMP ANYING HARDWARE.
2.NO LIABILITY FOR CONSEQUENTIAL DAMAGES. IN NO EVENT SHALL
CABLETRON OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER
(INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS,
PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION, SPECIAL,
INCIDENTAL, CONSEQUENTIAL, OR RELIANCE DAMAGES, OR OTHER LOSS)
ARISING OUT OF THE USE OR INABILITY TO USE THIS CABLETRON PRODUCT,
EVEN IF CABLETRON HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH
DAMAGES. BECAUSE SOME STATES DO NOT ALLOW THE EXCLUSION OR
LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, OR
ON THE DURATION OR LIMITATION OF IMPLIED WARRANTIES, IN SOME
INSTANCES THE ABOVE LIMITATIONS AND EXCLUSIONS MAY NOT APPLY TO
YOU.
WARRANTY. Except as may be specifically provided by Cabletron in
UNITED STATES GOVERNMENT RESTRICTED RIGHTS
The enclosed product (a) was developed solely at private expense; (b) contains “restricted computer
software” submitted with restricted rights in accordance with Section 52227-19 (a) through (d) of the
Commercial Computer Software - Restricted Rights Clause and its successors, and (c) in all respects
is proprietary data belonging to Cabletron and/or its suppliers.
For Department of Defense units, the product is licensed with “Restricted Rights” as defined in the
DoD Supplement to the Federal Acquisition Regulations, Section 52.227-7013 (c) (1) (ii) and its
successors, and use, duplication, disclosure by the Government is subject to restrictions as set forth in
subparagraph (c) (1) (ii) of the Rights in Technical Data and Computer Software clause at
guide describes the 6E122-26, 6E132-25, 6E123-26 and 6E133-25
Interface Modules and provides information concerning network
requirements, installation, troubleshooting, and the use of Local
Management.
6E122-26, 6E132-25, 6E123-26 and
. This
1.1USING THIS GUIDE
Read through this guide completely to understand the interface module
features, capabilities, and Local Management functions. A general
working knowledge of Ethernet and IEEE 802.3 type data
communications networks and their physical layer components is helpful
when using these devices.
NOTE
Unless noted differently, the information in this guide applies to
all four SmartSwitch 6000 interface modules, which are
referred to as either the “6E12X-26 and 6E13X-25” or the
“module(s)”.
1.2STRUCTURE OF THIS GUIDE
This guide is organized as follows:
Chapter 1,
the features of the 6E12X-26 and 6E13X-25, provides instructions on
obtaining additional help and concludes with a list of related manuals.
Chapter 2,
to consider before installing the 6E12X-26 and 6E13X-25 into the 6C105
SmartSwitch 6000 chassis.
Chapter 3,
modules in the chassis and connect cables to the modules.
Chapter 4,
LANVIEW LEDs that enable you to quickly diagnose
network/operational problems.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide1-1
Introduction
Network Requirements
Installation
Troubleshooting
, outlines the contents of this manual, describes
, provides instructions on how to install the
, details the 6E12X-26 and 6E13X-25
, explains the network requirements
Chapter 1:
Introduction
Chapter 5,
Local Management
, describes how to access Local
Management and use the Local Management screens to manage the
6E12X-26 and 6E13X-25 interface modules and the 6C105 chassis.
Appendix A,
Specifications
, contains information on functionality and
operating specifications, connector pinouts, environmental requirements,
and physical properties.
Appendix B,
FE-100TX, FE-100FX and FE-100F3 Specifications
,
contains information about FE-100TX pinouts and information
concerning cable types used with the FE-100FX and FE100-F3.
Appendix C,
Mode Switch Bank Settings and Optional Installations
,
describes how to install optional Fast Ethernet Interface Modules and ho w
to set the Mode Switches.
1.36E12X-26 AND 6E13X-25 OVERVIEW
The 6E12X-26 and 6E13X-25, shown in Figure 1-1, are interface
modules for Cabletron Systems 6C105 SmartSwitch 6000 chassis.
The 6E12X-26 and 6E13X-25 are high-speed network switch devices that
support 802.1D switching (bridging), 802.1Q switching, and Cabletron
Systems SecureFast Switching Virtual Network technology. Ports 25 and
26 of the 6E12X-26 support optional Fast Ethernet Interface Modules and
can provide uplinks to 100BASE-TX or 100BASE-FX Fast Ethernet
networks. The 6E13X-25 is capable of being equipped with a High Speed
Interface Module (HSIM) that provides for additional connectivity to
other high speed networking technologies such as Asychronous Transfer
Mode (ATM), Wide Area Networks (WANs) and Fiber Distributed Data
Interface (FDDI).
The 6E12X-26 and 6E13X-25 can be used to connect individual
high-bandwidth user devices, such as workstations, and to provide a
central switching point for multiple Ethernet segments using devices such
as Cabletron Systems HubSTACK or other third party stackable devices.
NOTE
1-26E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Figure 1-1 displays the 6E122-26 and 6E132-25. The
6E122-26 and the 6E123-26 are functionally identical, as are
the 6E132-25 and the 6E133-25. The only difference being that
the 6E123-26 and 6E133-25 modules support RJ21 front panel
connections.
6E12X-26 and 6E13X-25 Overview
Network
Ports 1-24
Ethernet
6E122-26
CPU
COM
12
34
56
78
910
11 12
15 16
17 18
19 20
21 22
23 24
1413
COM Ports
System
LEDs
Port Status
LEDs
Ethernet
6E132-25
CPU
COM
12
34
56
78
910
11 12
15 16
17 18
19 20
21 22
23 24
Network
Ports 1-24
1413
25
Fast Ethernet
Interface Module
Ports 25 and 26
26
HSIM Slot
207601
Figure 1-1 The 6E122-26 and 6E132-25
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide1-3
Chapter 1:
Introduction
1.3.1Connectivity
The 6E122-26 and 6E132-25 connect to Ethernet networks or
workstations through 24 RJ45 ports on the front panel. These ports
support UTP connections up to 100 meters. The ports are IEEE 802.3
10BASE-T compliant.
The 6E123-26 and 6E133-25 connect to Ethernet networks or
workstations through two RJ21 connectors on the front panel. These
connectors support 25 pair cable at lengths up to 100 meters. The ports
are IEEE 802.3 10BASE-T compliant.
The 6E12X-26 modules have two front panel slots (ports 25 and 26) for
optional Fast Ethernet Interface Modules to support an uplink to
100 Mbps Ethernet backbones or a high speed connection to a local
server.
The 6E13X-25 modules have one front panel slot for an optional High
Speed Interface Module to provide for additional connectivity to other
high speed networking technologies such as ATM, WANs and FDDI.
1.3.2Full Duplex Switched Ethernet
Each switched Ethernet port supports full wire-speed Ethernet
communications and can be configured to operate in Full Duplex
Switched Ethernet mode, which provides up to 20 Mbps of bandwidth.
The optional Fast Ethernet Interface Modules for the 6E12X-26 can also
be configured to operate in Full Duplex Switched Ethernet mode, which
provides up to 200 Mbps of bandwidth.
1-46E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
6E12X-26 and 6E13X-25 Overview
1.3.3SmartTrunk
SmartTrunk, also referred to as SmartTrunking, is Cabletron Systems’
terminology for load balancing or load sharing. SmartTrunk technology
provides an easy-to-implement mechanism to group, or aggregate,
multiple links of any technology together to scale the backbone
bandwidth beyond the limitations of a single link. All links are
user-configurable so administrators can scale the backbone bandwidth by
adding SmartTrunk links. The SmartTrunk benefits are as follows:
•
All purchased bandwidth is used.
•
Distributed, resilient links increase reliability and performance.
•
Multiple technologies are supported within a single trunk for
maximum flexibility.
For more information about SmartTrunk, refer to the Cabletron Systems
SmartTrunk User’s Guide
.
1.3.4Management
Management of the 6E12X-26 and 6E13X-25 is accomplished using
Local Management tools or remote SNMP management stations. Local
Management is accessible through the RS232 COM port on the front
panel using a local VT100 terminal, or a remote VT100 terminal via a
modem connection, and in-band via a Telnet connection. In-band remote
management is possible through any SNMP compliant Network
Management Software.
1.3.5Switching Options
The 6E12X-26 and 6E13X-25 provide 802.1D switching, 802.1Q
switching, or SecureFast Switching Virtual Network Services between all
of the front panel interfaces including Fast Ethernet Interface Modules
and High Speed Interface Modules (HSIMs).
SecureFast switching and 802.1Q switching allow for future migration to
Virtual Network technologies without requiring the replacement of
existing equipment.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide1-5
Chapter 1:
Introduction
1.3.6Standards Compatibility
The 6E12X-26 and 6E13X-25 are fully compliant with the IEEE 802.3
standard. The optional Fast Ethernet Interface Modules are fully
compliant with the IEEE 802.3u standard. The 6E12X-26 and 6E13X-25
provide IEEE 802.1D Spanning T ree Algorithm (STA) support to enhance
the overall reliability of the network and protect against “loop”
conditions. The 6E12X-26 and 6E13X-25 support a wide variety of
industry standard MIBs including RFC 1213 (MIB II), RFC 1757
(RMON), RFC 1493 (Bridge MIB) and RFC 1354 (FIB MIB). A full suite
of Cabletron Systems Enterprise MIBs provide a wide array of statistical
information to enhance troubleshooting.
1.3.7LANVIEW Diagnostic LEDs
LANVIEW diagnostic LEDs serve as an important troubleshooting aid by
providing an easy way to observe the status of indi vidual ports and overall
network operations. Chapter 4 provides details about the 6E12X-26 and
6E13X-25 LANVIEW LEDs.
1.3.8Year 2000 Compliant
The 6E12X-26 and 6E13X-25 have an internal clock that can maintain the
current time and date beyond the year 1999.
1.3.9Runtime IP Address Discovery
This feature enables the modules to automatically accept an IP address
from a BootP server on the network into NVRAM without requiring a
user to enter an IP address through Local Management.
When the modules are connected to the network and powered up,
Runtime IP Address Discovery (RAD) checks the modules for an IP
address. If one has not yet been assigned (module and 6C105 chassis IP
address set to 0.0.0.0), RAD checks to see if any of the module interfaces
have a link. If so, RAD sends out Reverse Address Resolution Protocol
(RARP) and BootP requests to obtain an IP address from a RARP or
BootP server on the network.
The RAD requests start out at an interval of one second. The interv al then
doubles after every transmission until an interval of 300 seconds is
reached. At this point, the interval remains at 300 seconds. The RAD
requests continue until an IP address is received from a RARP or BootP
server, or an IP address is entered using Local Management.
1-66E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
6E12X-26 and 6E13X-25 Overview
1.3.10Local Management Features
Local Management provides the tools that allow management of the
6E12X-26 and 6E13X-25, the Fast Ethernet Interface Modules, the High
Speed Interface Module (HSIM) and the 6C105 chassis. It also allows the
following tasks to be performed:
•
Manage any module installed in the 6C105 via a single terminal
connection.
•
Assign an IP address and subnet mask to the 6C105 chassis, 6E12X-26
and 6E13X-25.
•
Select a default gateway.
•
Control local and remote access.
•
Designate workstations to receive SNMP traps from the 6E12X-26
and 6E13X-25 interface modules and the 6C105 chassis.
•
Configure module specific SNMP MIB objects including the IETF
Bridge MIB objects.
Chapter 5 provides detailed information about Local Management of the
6E12X-26 and 6E13X-25, the optional Fast Ethernet Interface Modules
and the 6C105 chassis. The associated High Speed Interface Module
user’s guide provides detailed information about Local Management of
the applicable HSIM.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide1-7
Chapter 1:
Introduction
1.4OPTIONAL FEATURES
Options for the 6E12X-26 and 6E13X-25 are Fast Ethernet Interface
Modules and High Speed Interface Modules, which add remote uplink
capability.
Cabletron Systems provides Fast Ethernet Interface Modules for the
6E12X-26 to support uplinks to 100 Mbps Ethernet backbones or high
speed connections to local servers. The Fast Ethernet Interface Modules
are listed in Table 1-1.
Table 1-1 Fast Ethernet Interface Modules
P/NDescriptionApplication
Supports Category 5 Unshielded Twisted Pair
(UTP) cabling with an impedance between 85
and 111 ohms.
Supports multimode fiber optic cabling.
Supports single mode fiber optic cabling.
FE-100TX
FE-100FX
FE-100F3
Uses RJ45
connector
Uses SC
connector
Uses SC
connector
Cabletron Systems provides High Speed Interface Modules for the
6E13X-25 to provide for additional connectivity to other high speed
networking technologies such as ATM, WANs and FDDI. The HSIMs
available for the 6E13X-25 are listed in the Release Notes.
1-86E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Document Conventions
1.5DOCUMENT CONVENTIONS
The following conventions are used throughout this document:
Note
NOTE
TIP
symbol. Calls the reader’s attention to any item of
information that may be of special importance.
Tip
symbol. Conveys helpful hints concerning procedures or
actions.
!
CAUTION
Caution
damage to the equipment.
Electrical Hazard Warning
that could result in personal injury or death due to an electrical
hazard.
symbol. Contains information essential to avoid
symbol. Warns against an action
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide1-9
Chapter 1:
Introduction
1.6GETTING HELP
For additional support related to this device or document, contact the
Cabletron Systems Global Call Center:
World Wide Web
Phone(603) 332-9400
Internet mailsupport@cabletron.com
FTPftp://ftp.cabletron.com
Login
Password
To send comments or suggestions concerning this document, contact the
Cabletron Systems Technical Writing Department via the following
email address: TechWriting@cabletron.com
Make sure to include the document Part Number in the email message.
http://www.cab letron.com/
For technical support, select
anonymous
your email address
Service and Support
Before calling the Cabletron Systems Global Call Center, have the
following information ready:
•
Your Cabletron Systems service contract number
•
A description of the failure
•A description of any action(s) already taken to resolve the problem
(e.g., changing mode switches, rebooting the unit, etc.)
•The serial and revision numbers of all involved Cabletron Systems
products in the network
•A description of your network environment (layout, cable type, etc.)
•Network load and frame size at the time of trouble (if known)
•The device history (i.e., have you returned the device before, is this a
recurring problem, etc.)
•Any previous Return Material Authorization (RMA) numbers
1-106E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Related Manuals
1.7RELATED MANUALS
The following manuals may help to set up, control, and manage the
6E12X-26 and 6E13X-25:
Cabletron Systems HSIM-A6DP User’s Guide
Cabletron Systems HSIM-F6 User’s Guide
Cabletron Systems HSIM-FE6 User’s Guide
Cabletron Systems HSIM-W6 User’s Guide
Cabletron Systems HSIM-W84 User’s Guide
Cabletron Systems HSIM-W87 User’s Guide
Cabletron Systems HSIM-G01/G09 User’s Guide
Cabletron Systems Ethernet Technology Guide
Cabletron Systems Cabling Guide
Cabletron Systems Port Based VLAN User’s Guide
Cabletron Systems SmartTrunk User’s Guide
These manuals can be obtained from the World Wide Web in Adobe
Acrobat Portable Document Format (PDF) at the following site:
http://www.cabletron.com/
NOTE
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide1-11
All documentation for the Cabletron Systems SecureF ast VLAN
Manager software is contained on the VLAN Manager
CD-ROM.
Chapter 1: Introduction
1-126E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
CHAPTER 2
NETWORK REQUIREMENTS
Before installing the 6E12X-26 and 6E13X-25 or Fast Ethernet Interface
Modules (FE-100TX, FE-100FX, or FE-100F3), review the requirements
and specifications referred to in this chapter concerning the following:
•SmartTrunk (Section 2.1)
•10BASE-T Twisted Pair Network (Section 2.2)
•100BASE-TX Twisted Pair Network (Section 2.3)
•100BASE-FX Fiber Optic Network (Section 2.4)
The network installation must meet the guidelines to ensure satisfactory
performance of this equipment. Failure to follow the guidelines may
produce poor network performance.
NOTE
The Cabletron Systems Cabling Guide and SmartTrunk User’s
Guide, referred to in the following sections, can be found on
the Cabletron Systems World Wide Web
site: http://www.cabletron.com/
2.1SmartTrunk
To connect the 6E12X-26 and 6E13X-25 to a network so it can take
advantage of the SmartTrunk feature, there are certain rules concerning
port connections and configurations that must be followed for proper
operation. Refer to the Cabletron Systems SmartTrunk User’s Guide for
additional information.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide2-1
Chapter 2: Network Requirements
2.210BASE-T NETWORK
When connecting a 10BASE-T segment to any of the 6E12X-26 and
6E13X-25 ports (Interfaces 1 through 24), ensure that the network meets
the Ethernet network requirements of the IEEE 802.3 standard for
10BASE-T. Refer to the Cabletron Systems Cabling Guide for details.
2.3100BASE-TX NETWORK
The 6E12X-26, with an FE-100TX installed in ports 25 and 26, provides
an RJ45 connection that supports Category 5 UTP cabling with an
impedance between 85 and 111 ohms. The device at the other end of the
twisted pair segment must meet IEEE 802.3u 100BASE-TX F ast Ethernet
network requirements for the devices to operate at 100 Mbps. Refer to the
Cabletron Systems Cabling Guide for details.
NOTE
The 6E12X-26 with an FE-100TX installed is capable of
operating at either 10 or 100 Mbps. The FE-100TX can
automatically sense the speed of the other device and adjusts
its speed accordingly.
2.4100BASE-FX FIBER OPTIC NETWORK
Ports 25 and 26 of the 6E12X-26 support the Cabletron Systems
FE-100FX and FE-100F3 fiber optic interface modules. The device at the
other end of the fiber optic segment must meet the 100BASE-FX Fast
Ethernet network requirements to operate at 100 Mbps. Refer to the
Cabletron Systems Cabling Guide for details.
Multimode Mode Fiber Optic Cable Length
The maximum multimode fiber optic cable length of a 100BASE-FX
segment is covered in the Cabletron Systems Cabling Guide.
Single Mode Fiber Cable Lengths
The maximum single mode fiber optic length of a 100BASE-FX segment
may be no more than 5 km between Data Terminal Equipment (DTE to
DTE) in half duplex mode or 20 km (DTE to DTE) in full duplex mode.
2-26E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
CHAPTER 3
INSTALLATION
Only qualified personnel should install the 6E12X-26 and
6E13X-25.
This chapter covers the following items:
•Required tools
•Unpacking the 6E12X-26 and 6E13X-25
•Installing the 6E12X-26 and 6E13X-25 into the 6C105 chassis
•Connecting to the network
3.1REQUIRED T OOLS
A Phillips screwdriver is required to install the optional Fast Ethernet
Interface Modules into the 6E12X-26.
3.2UNPACKING THE 6E12X-26 AND 6E13X-25
1. Open the box and remove the packing material protecting the module.
2. Verify the contents of the carton as listed in Table 3-1.
Table 3-1 Contents of Shipping Carton
ItemQuantity
6E132-25, 6E122-26,
6E133-25 or
6E123-26
Release Notes1
RJ21 Angle Adapter
(6E123-26 and
6E133-25 only)
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide3-1
1
2
Chapter 3: Installation
3.36E12X-26 AND 6E13X-25 OPTIONS
NOTE
If the 6E12X-26 is to be installed with an optional Fast Ethernet Interface
Module, refer to Appendix C for installation instructions. The installation
instructions for the HSIMs available for the 6E13X-25 are located in the
associated user’s guide.
Install any optional equipment before proceeding to
Section 3.4.
3.4INSTALLING THE 6E12X-26 AND 6E13X-25 INTO
THE 6C105 CHASSIS
Failure to observe static safety precautions could cause
damage to the 6E12X-26 and 6E13X-25. Follow static safety
!
CAUTION
CAUTION
The 6E12X-26 and 6E13X-25 can be installed in any of the 5 slots that
are available. To install a module, proceed as follows:
handling rules and properly wear the antistatic wrist strap
provided with the 6C105 chassis.
Do not cut the non-conductive bag to remove the module.
Damage could result from sharp objects contacting the board
!
or components.
1. Remove the blank panel covering the slot in which the module will be
installed. All other slots must remain covered to ensure proper airflow
and cooling. (Save the blank plate in the event you need to remove the
module.)
2. Carefully remove the module from the shipping box. (Save the box
and packing materials in the event the module must be reshipped.)
3. Locate the antistatic wrist strap shipped with the 6C105 chassis.
Attach the strap to your wrist and plug the cable from the antistatic
wrist strap into the ESD grounding receptacle at the upper right corner
of the 6C105.
3-26E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Installing the 6E12X-26 and 6E13X-25 Into the 6C105 Chassis
4. Remove the module from the plastic bag. (Save the bag in the event
the module must be reshipped.) Observe all precautions to prevent
damage from Electrostatic Discharge (ESD).
5. Examine the module for damage. If any damage exists, DO NOT
install the module. Immediately contact the Cabletron Systems Global
Call Center.
To prevent damaging the bac kplane connectors in the f ollo wing
step, take care that the module slides in straight and properly
!
CAUTION
engages the backplane connectors.
NOTE
In the following step, ensure that the top plastic locking tab
lines up with the desired slot number located on the front panel
of the chassis. Refer to Figure 3-1.
6. Locate the slot guides that line up with the number of the slot in which
the module will be installed. Install the module in the chassis by
aligning the module circuit card between the upper and lower metal
rail guides of the desired slot, sliding it into the chassis, and locking
down the top and bottom plastic locking tabs, as shown in Figure 3-1.
Take care that the module slides in straight and properly engages the
backplane connectors.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide3-3
Chapter 3: Installation
Slot Number
2
1
3
45
Ethernet
6E132-25
CPU
Plastic Locking Tab
PS1
COM
12
34
56
78
910
11 1 2
1413
15 16
17 18
19 20
21 22
23 24
PS2
Metal Back-Panel
Circuit Card
Card Guides
Plastic Locking Tab
207602
Figure 3-1 Installing an Interface Module
3-46E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Connecting to the Network
3.5CONNECTING TO THE NETWORK
This section provides the procedures for connecting segments from the
network or other devices to the modules.
NOTE
If the 6E12X-26 and 6E13X-25 are being installed in a network
using SmartTrunking, there are rules concerning the network
cable and port configurations that must be followed for
SmartTrunking to operate properly. Before connecting the
cables refer to the Cabletron Systems
Guide
shipped with the modules..
SmartTrunk User’s
Ports 1 through 24 on the 6E122-26 and 6E132-25 have RJ45 connectors
for twisted pair connections. Ports 1 through 24 on the 6E123-26 and
6E133-25 have RJ21 connectors for twisted pair connections. Ports 25
and 26 of the 6E12X-26 support FE-100TX, FE-100FX, or FE-100F3
Fast Ethernet Interface Modules. The FE-100TX has an RJ45 connector
for a Category 5 UTP cable connection. The FE-100FX has an SC style
connector for a multimode fiber optic cable connection. The FE-100F3
has an SC style connector for a single mode fiber optic cable connection.
Refer to Section 3.5.1 to make twisted pair connections to ports 1 through
24 of the 6E122-26 and 6E132-25.
Refer to Section 3.5.2 to make twisted pair connections to ports 1 through
24 of the 6E123-26 and 6E133-25.
Refer to Section 3.5.3 to make a Twisted Pair connection to an
FE-100TX.
Refer to Section 3.5.4 to make a fiber optic connection to an FE-100FX or
FE-100F3.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide3-5
Chapter 3: Installation
3.5.1Connecting UTP Cables to Ports 1 Thr ough 24 of
the 6E122-26 and 6E132-25
Ports 1 through 24 of the 6E122-26 and 6E132-25 are 10BASE-T ports
with internal crossovers. When connecting a workstation, use a
straight-through cable. When connecting networking devices, such as
another bridge, repeater, or router, use a crossover cable.
Connect a twisted pair segment to the 6E122-26 and 6E132-25 as follows:
1. Ensure that the device connected to the other end of the segment is
powered ON.
2. Connect the twisted pair segment to the 6E132-25 or 6E122-26 by
inserting the RJ45 connector on the twisted pair segment into the
desired RJ45 port (Ports 1 through 24) as shown in Figure 3-2.
.
56
78
910
11 12
15 16
1413
RX (Receive)
LED
17 18
19 20
21 22
23 24
207603
Figure 3-2 6E122-26 and 6E132-25 Twisted Pair Connection
3-66E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Connecting to the Network
3. Verify that a link exists by checking that the port RX LED is on
(flashing amber, blinking green, or solid green). If the RX LED is off,
perform the following steps until it is on:
a. Verify that the 10BASE-T device at the other end of the twisted
pair segment is ON and connected to the segment.
b. Verify that the RJ45 connectors on the twisted pair segment have
the proper pinouts (Figure 3-3) and check the cable for continuity.
NOTE:
RX+/RX– and TX+/TX–
must share a common
color pair.
Figure 3-3 Cable Pinouts - (RJ45) Crossover Cable
TO
SmartSwitch RJ45 Port
RX+
1
RX–2
TX+
3
TX–
6
10BASE-T Device Port
RJ45 to RJ45
TO
1
2
3
6
RX+
RX–
TX+
TX–
c. Check that the twisted pair connection meets the dB loss and cable
specifications outlined in Chapter 2.
If a link is not established, contact the Cabletron Systems Global Call
Center. Refer to Section 1.6, Getting Help, for details.
4. Repeat steps 1 through 3, above, until all connections have been made.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide3-7
Chapter 3: Installation
3.5.2Connecting UTP Cables to Ports 1 Thr ough 24 of
the 6E133-25 and 6E123-26
When facing the front panel of the 6E133-25 or 6E123-26, the upper
RJ21 is the connector for 10BASE-T ports 1 through 12. The lower RJ21
is for 10BASE-T ports 13 through 24. All 24 ports have internal
crossovers.
Connect a twisted pair segment to the 6E133-25 and 6E123-26 as follows:
1. Ensure that the device connected to the other end of the segment is
powered ON.
2. If using an RJ21 straight connector, plug it into the appropriate RJ21
port as shown in Figure 3-4 or, if using the RJ21 angle adapter
supplied with the device, insert the RJ21 angle adapter as shown in
Figure 3-5. The RJ21 angle adapter allows the cable to be inserted
without interfering with the proper attachment of the second
connector.
.
Screw Hole
910
11 12
Screw
1
1413
24
15 16
RX (Receive)
LED
17 18
19 20
21 22
23 24
Screw
13
Screw Hole
207603
Figure 3-4 6E133-25 and 6E123-26 Twisted Pair Connection
3-86E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Screw
Screw Hole
Connecting to the Network
910
11 12
1413
Screw
15 16
17 18
19 20
21 22
23 24
Screw Hole
RX (Receive)
LED
207603
Figure 3-5 Connection Using the RJ21 Angle Adapter
3. Tighten the two screws on the RJ21 connector or RJ21 angle adapter,
as applicable, to secure it to the module.
NOTE
The cable pinouts for a 25 pair cab le (RJ21) can be found in the
Cabletron Systems
Cabling Guide
. Refer to Section 1.7,
Related Manuals, for details on how to obtain this document.
4. If using the RJ21 angle adapter, plug the 25 pair cable into the adapter
as shown in Figure 3-5.
5. Verify that a link exists by checking that the port RX LEDs are on
(flashing amber, blinking green, or solid green). If the RX LEDs are
off, perform the following steps until it is on:
a. Verify that the 10BASE-T device at the other end of the twisted
pair segment is ON and connected to the segment.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide3-9
Chapter 3: Installation
b. Verify that the RJ21 connectors on the twisted pair segment have
the proper pinouts and check the cable for continuity.
c. Check that the twisted pair connection meets the dB loss and cable
specifications outlined in Chapter 2.
If a link is not established, contact the Cabletron Systems Global Call
Center. Refer to Section 1.6, Getting Help, for details.
6. Repeat steps 1 through 4, above, until all connections have been made.
3.5.3Connecting a Twisted Pair Segment to the
FE-100TX
An FE-100-TX installed in port 25 and/or 26 has an internal crossover
switch. When connecting a workstation, use a straight-through cable and
set the Fast Ethernet Interface Module crossover switch shown in
Figure 3-6 to the crossed over position marked with X. When connecting
networking devices, such as another bridge, repeater, or router, use a
straight-through cable and set the Fast Ethernet Interface Module
crossover switch shown in Figure 3-6 to the not crossed over position,
marked with =.
A schematic of a crossover cable is shown in Figure 3-6. If the wires do
not cross over, use the switch on the FE-100TX to internally cross over
the RJ45 port. Figure 3-6 shows how to properly set the FE-100TX
crossover switch.
Position X
(crossed over)
1. RX+
2. RX-
3. TX+
4. NC
5. NC
6. TX-
7. NC
x
FE-100TX
=
8. NC
Figure 3-6 FE-100TX Crossover Switch
3-106E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Position =
(not crossed over)
1. TX+
10
2. TX-
100
3. RX+
4. NC
5. NC
6. RX-
7. NC
8. NC
16651_05
Connecting to the Network
Connect an FE-100TX to a twisted pair segment as follows:
1. Ensure that the device connected to the other end of the segment is
powered ON.
2. Connect the twisted pair segment to the module by inserting the RJ45
connector on the twisted pair segment into the RJ45 port on the
module shown in Figure 3-6.
3. Verify that a link exists by checking that the port RX LED is on
(flashing amber, blinking green, or solid green). If the RX LED is off,
perform the following steps until it is on:
a. V erify that the 100B ASE-TX device at the other end of the twisted
pair segment is powered up.
b. Verify that the RJ45 connector on the twisted pair segment has the
proper pinouts.
c. Check the cable for continuity.
d. Make sure that the twisted pair connection meets dB loss and cable
specifications outlined in Section 2.3.
e. Confirm that the crossover switch is in the correct position.
If a link is not established, contact the Cabletron Systems Global Call
Center. Refer to Section 1.6, Getting Help, for details.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide3-11
Chapter 3: Installation
3.5.4Connecting a Fiber Optic Segment to the
FE-100FX and FE-100F3
The FE-100FX and FE-100F3 have an SC style network port (see
Figure 3-7). Cabletron Systems supplies fiber optic cable that uses SC
style connectors that are keyed to ensure proper crossing over of the
transmit and receive fibers.
An odd number of crossovers (preferably one) must be
maintained between devices so that the transmit port of one
!
CAUTION
Fiber Optic Network Connection
1. Remove the protective plastic covers from the fiber optic ports on the
device is connected to the receive port of the other device and
vice versa.
If the fiber optic cable being used has SC style connectors that
do not resemble MIC style connectors, or has SC connectors
on one end and a different type on the other, such as ST
connectors, ensure that the proper crossing over occurs.
applicable port on the module and from the ends of the connectors.
The FE-100F3 uses Class 1 lasers. Do not use optical
instruments to view the laser output. The use of optical
!
CAUTION
CAUTION
instruments to view laser output increases eye hazard. When
viewing the output optical port, power must be removed from
the network adapter.
Do not touch the ends of the fiber optic strands, and do not let
the ends come in contact with dust, dirt, or other contaminants.
!
Contamination of the ends causes problems in data
transmissions. If the ends become contaminated, clean them
with alcohol using a soft, clean, lint-free cloth.
2. Insert one end of the SC connector into the FE-100FX or FE-100F3
installed in the 6E12X-26. See Figure 3-7.
3. At the other end of the fiber optic cable, attach the SC connector to the
other device.
3-126E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
RX LED
TX LED
Connecting to the Network
25
FE-100FX
26
Figure 3-7 FE-100FX and FE-100F3 Port
4. Verify that a link exists by checking that the port RX LED is on
(flashing amber, blinking green, or solid green). If the RX LED is off
and the TX LED is not blinking amber, perform the following steps
until it is on:
NOTE
The port RX LED flashes green and amber during bootup.
a. Check that the power is turned on for the device at the other end of
the link.
b. Verify proper crossing over of fiber strands between the
applicable port on the 6E12X-26 and the fiber optic device at the
other end of the fiber optic link segment.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide3-13
Chapter 3: Installation
c. Verify that the fiber connection meets the dB loss specifications
outlined in Chapter 2.
If a link has not been established, contact the Cabletron Systems Global
Call Center. Refer to Section 1.6, Getting Help, for details.
3.6COMPLETING THE INSTALLATION
The 6E12X-26 and 6E13X-25 are now ready to be set up through Local
Management. Refer to Chapter 5, Local Management, to configure the
modules and 6C105 chassis.
3-146E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
CHAPTER 4
TROUBLESHOOTING
This chapter provides information concerning the following:
•Using the LANVIEW diagnostic and status monitoring system
•Troubleshooting network and module operational problems
•Using the RESET button
NOTE
The four interface modules co v ered in this manual all share the
same LANVIEW LEDs.
4.1USING LANVIEW
The 6E12X-26 and 6E13X-25 use Cabletron Systems built-in visual
diagnostic and status monitoring system called LANVIEW. The
LANVIEW LEDs (Figure 4-1) allow quick observation of the network
status to aid in diagnosing network problems. Refer to Table 4-1 for a
description of the LEDs.
For a functional description of the LANVIEW LED on the optional Fast
Ethernet Interface Module (FE-100TX), refer to Section 4.2.
All LEDs for the High Speed Interface Module (HSIM) are located on the
HSIM and are described in the associated HSIM user’s guide.
NOTE
The terms flashing, blinking, and solid used in the LED
definition tables of this chapter indicate the following:
Flashing indicates an irregular LED pulse.
Blinking indicates a steady LED pulse.
Solid indicates a steady LED light. No pulsing.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide4-1
Chapter 4: Troubleshooting
Ethernet
6E122-26
CPU
COM
12
34
56
78
910
11 12
15 16
17 18
19 20
21 22
23 24
CPU LED
1413
Receive (RX)
Transmit (TX)
25
26
207604
Figure 4-1 LANVIEW LEDs
4-26E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Using LANVIEW
Table 4-1 LANVIEW LEDs
LEDColorStateRecommended Action
OffPower off.Power up chassis.
Contact the Cabletron
Systems Global Call Center
(GCC).
No action. If LED remains Red
for several minutes, contact
the Cabletron Systems GCC.
Contact the Cabletron
Systems GCC.
No action. If LED remains
Amber for several minutes,
contact the Cabletron Systems
GCC.
No action.
No error.
No error.
No error.
No error.
Contact the Cabletron
Systems GCC for assistance.
CPU
RX
Blinking. Hardware
failure has occurred.
Red
Solid. Resetting,
normal power up reset.
AmberBlinking. Crippled.
Solid. Testing.
GreenSolid. Functional.No action.
Amber
and
Green
Off
Green
Amber
RedDiagnostic failure.
Booting. Blinks amber
and green while
booting.
No link. No activity.
Port enabled or
disabled.
Solid. Port enabled,
link, no activity.
Blinking. Port
disabled, link.
Flashing. Port
enabled, link, activity.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide4-3
Chapter 4: Troubleshooting
Table 4-1 LANVIEW LEDs (Continued)
LEDColorStateRecommended Action
Should flash green every 2
seconds indicating BPDUs
being sent if STA is enabled
and there is a valid link. If ST A
is enabled, and the LED does
not flash green, contact the
Cabletron Systems GCC.
No action.
Port may be disabled due to
Spanning T ree .
No action.
Contact the Cabletron
Systems GCC for assistance.
TX
Off
Green
Amber
Red
Port enabled, and no
activity.
Flashing. Indicates
activity. Rate indicates
data rate.
Blinking. Port in
standby, link.
Flashing. Indicates
collision rate.
Solid. Diagnostic
Failure.
4.2FE-100TX LED
The optional FE-100TX has one LED labeled 10/100. The 10/100 LED
together with the receive LED allo ws the user to determine the link status
and the operating speed of the Fast Ethernet Interface Module. The
10/100 LED and the Receive (RX) LED are shown in Figure 4-2.
Table 4-2 and Table 4-3 pro vide a functional description of the FE-100TX
LED when the RX LED is on or off, respectively.
4-46E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
10
100
LED
Receive
(RX) LED
FE-100TX
2526
=
x
100
10
22
Figure 4-2 FE-100TX LED
FE-100TX LED
NOTE
LEDColorDescription
10/100
LED is on.
Table 4-2 FE-100TX LED Indications When the RX LED Is On
OffFE-100TX is operating at 10 Mbps.
GreenFE-100TX is operating at 100 Mbps.
No link exists if the associated port (port 25 or 26) Receive
A link exists if the associated port (port 25 or 26) Receive (RX)
NOTE
LEDColorDescription
10/100
(RX) LED is off.
Table 4-3 FE-100TX LED Indications When the RX LED Is Off
No link or no cable attached. FE-100TX
Off
Green
forced to 10 Mbps operation, or is
manually set to “auto-negotiate” mode.
No link or no cable attached. FE-100TX is
forced to 100 Mbps operation.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide4-5
Chapter 4: Troubleshooting
4.3TROUBLESHOOTING CHECKLIST
If the 6E12X-26 or 6E13X-25 is not working properly, refer to Table 4-4
for a checklist of possible problems, causes, and recommended actions to
resolve the problem.
Table 4-4 Troubleshooting Checklist
ProblemPossible CauseRecommended Action
All LEDs are OFF.
No Local
Management
Password screen.
Cannot contact the
6E132-25 or
6E122-26 from
in-band
management.
Port(s) goes into
standby for no
apparent reason.
User parameters (IP
address, Device and
Module name, etc.)
are lost when the
6E12X-26 or
6E13X-25 is
powered down or
the front panel
RESET button is
pressed.
Loss of power to the
6C105 chassis.
6E13X-25 or 6E12X-26
not properly installed.
Autobaud enabled. But
baud rate has not yet
been sensed.
Terminal setup is not
correct.
Improper console cable
pinouts.
Improper Community
Names T ab le.
6E12X-26 or 6E13X-25
does not have an IP
address.
Port is disabled.Enable port.
No link to device.Check link to device.
6E12X-26 or 6E13X-25
detects a looped
condition.
Mode switch (7), NVRAM
Reset, was changed
sometime before either
cycling power or
pressing the RESET
button, causing the
user-entered parameters
to reset to factory default
settings.
Check the proper connection
of the power cable and its
access to a live outlet.
Check the installation.
Press ENTER (RETURN)
(may take up to four times).
Refer to Chapter 5 for proper
setup procedures.
Refer to Appendix A for
proper console port pinouts.
Refer to Chapter 5
for Community Names Table
setup.
Refer to Chapter 5 for IP
address assignment
procedure.
Review network design and
delete unnecessary loops.
Reenter the lost parameters
as necessary. Call the
Cabletron Systems GCC if
problem continues.
4-66E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Using the RESET Button
4.4USING THE RESET BUTTON
The RESET button located near the upper plastic locking tab of the
module (refer to Figure 4-3) resets the 6E12X-26 and 6E13X-25
processor without affecting the NVRAM.
Pressing the RESET button resets the device, and all current
switching being performed by the device is halted. A module
!
CAUTION
downtime of up to two minutes will result from this action.
Ethernet
6E132-25
Reset Button
Figure 4-3 RESET Button
To reset the 6E12X-26 and 6E13X-25 processor, press and release the
RESET button. The module processor goes through a reset process of
approximately 20 seconds. Additional module do wntime may be added as
the module reenters the network.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide4-7
Chapter 4: Troubleshooting
4-86E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
CHAPTER 5
LOCAL MANAGEMENT
This chapter explains how to set up a management terminal to access
6E12X-26 and 6E13X-25 Local Management. It also explains how to use
the Local Management screens and commands.
NOTE
The Local Management screens shown in this chapter are for
the 6E122-26. The 6E132-25, 6E133-25 and 6E123-26 share
most of the following Local Management screens. All Local
Management functions specific to any of the interface modules
are preceded by a Note to alert the reader.
5.1OVERVIEW
Local Management for the 6E12X-26 and 6E13X-25 consists of a series
of management screens that allow the management of the module, the
attached segments and the 6C105 chassis. The management screens allow
the user to perform the following tasks:
•Manage any interface module in the chassis via a connection to a
single interface module.
•Assign IP addresses and subnet masks to the 6E12X-26, 6E13X-25
and the 6C105 chassis.
•Control access to the 6E12X-26, 6E13X-25 and the 6C105 chassis by
establishing community names.
•Download a new image of operating software.
•Designate which Network Management Workstations receive SNMP
traps from the 6E12X-26, 6E13X-25 and the 6C105 chassis.
•Monitor the environmental status of the 6C105 chassis.
•View switch, interface, and RMON statistics.
•Assign ports to operate in standard or full duplex mode.
•Enable trunking of ports to perform load sharing.
•Configure the Fast Ethernet Interface Modules of the 6E12X-26 and
the HSIM of the 6E13X-25.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide5-1
Chapter 5: Local Management
There are three ways to access Local Management:
•Locally using a VT type terminal connected to the COM port of the
6E13X-25 or 6E12X-26.
•Remotely using a VT type terminal connected through a modem.
•In-band through a Telnet connection.
5.2LOCAL MANAGEMENT KEYBOARD
CONVENTIONS
All key names appear as capital letters in this manual. Table 5-1 explains
the keyboard conventions and the key functions that are used.
Table 5-1 Keyboard Conventions
KeyFunction
These are selection keys that perform the same
ENTER Key
RETURN Key
Local Management function. For example, “Press
ENTER” means that you can press either ENTER
or RETURN, unless this manual specifically
instructs you otherwise.
This key allows an escape from a Local
ESCAPE (ESC) Key
SPACE bar
BACKSPACE Key
Arrow Keys
[–] Key
DEL Key
Management screen without saving changes. For
example, “Press ESC twice” means the ESC key
must be pressed quickly two times.
These keys cycle through selections in some Local
Management fields. Use the SPACE bar to cycle
forward through selections and use BACKSPACE
to cycle backward through selections.
These are navigation keys. Use the UP-ARROW,
DOWN-ARROW, LEFT-ARROW, and
RIGHT-ARROW keys to move the screen cursor.
For example , “Use the arrow keys” means to press
whichever arrow key moves the cursor to the
desired field on the Local Management screen.
This key decreases values from a Local
Management increment field. For example, “Press
[–]” means to press the minus sign key.
The DEL (Delete) key removes characters from a
Local Management field. F or e xample, “Press DEL”
means to press the Delete key.
5-26E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Management Terminal Setup
5.3MANAGEMENT TERMINAL SETUP
Use one of the following systems to access Local Management:
•An IBM or compatible PC running a VT series emulation software
package
•A Digital Equipment Corporation VT100 type terminal
•A VT type terminal running emulation programs for the Digital
Equipment Corporation VT100 series
•A remote VT100 type terminal via a modem connection
•In-band via a Telnet connection
5.3.1Console Cable Connection
Use the Console Cable Kit provided with the 6C105 chassis to attach the
management terminal to the COM port as shown in Figure 5-1.
Connect an IBM PC or compatible device, running the VT terminal
emulation, to the 6E12X-26 and 6E13X-25 as follows:
1. Connect the RJ45 connector at one end of the cable (supplied in the
kit) to the COM port on the 6E12X-26 and 6E13X-25.
2. Plug the RJ45 connector at the other end of the cable into the
RJ45-to-DB9 adapter (supplied in the kit).
3. Connect the RJ45-to-DB9 adapter to the PC communications port.
Ethernet
6E122-26
PS1
1
2345
RJ45 COM Port
UTP Cable
With RJ45 Connectors
PC
RJ45-to-DB9
PC Adapter
Figure 5-1 Management Terminal Connection
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide5-3
PS2
Ethernet
6E122-26
COM
CPU
12
34
56
78
910
1112
1413
1516
1718
1920
2122
2324
Reserved for FEPIM
25
Reserved for FEPIM
26
COM
CPU
12
34
Chapter 5: Local Management
5.3.2Connecting an Uninterruptible Power Supply
(UPS)
If the 6C105 chassis is connected to an American Power Conversion
(APC) UPS for protection from a loss of power, a connection from the
COM port of a module to the UPS can be made to monitor the status of
the UPS. To use the COM port for this purpose, it must be reconfigured to
support the UPS application. This procedure is performed from the
General Configuration screen of the interface module. Section 5.15.11,
Configuring the COM Port, provides detailed instructions on
configuring the COM port for UPS applications. Refer to the UPS
documentation for details on how to access the status information.
Use the Console Cable Kit provided with the 6C105 chassis to attach the
UPS to the module COM port as shown in Figure 5-2.
Connect the UPS device to the COM port of the 6E12X-26 and 6E13X-25
as follows:
1. Connect the RJ45 connector at one end of the cable to the COM port
on the 6E12X-26 and 6E13X-25.
2. Plug the RJ45 connector at the other end of the cable into the
RJ45-to-DB9 male (UPS) adapter, Cabletron Systems Part No.
9372066.
3. Connect the RJ45-to-DB9 male (UPS) adapter to the female DB9 port
on the rear of the UPS device (refer to the particular UPS device’s user
instructions for more specific information about the monitoring
connection).
Ethernet
6E122-26
PS2
COM
CPU
12
34
196051
UTP Cable
PS1
Ethernet
6E122-26
COM
CPU
12
34
56
78
910
1112
1413
1516
1718
1920
2122
2324
Reserved for FEPIM
25
Reserved for FEPIM
26
UPS Device
RJ45 COM Port
DB9 Port
RJ45-to-DB9
UPS Adapter
1
2345
With RJ45 Connectors
Figure 5-2 Uninterruptible Power Supply (UPS)
5-46E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Management Terminal Setup
5.3.3Management Terminal Setup Parameters
Table 5-2 lists the setup parameters for the local management terminal.
Table 5-2 VT Terminal Setup
Display Setup Menu
Columns ->
Controls ->
Auto Wrap ->
Scroll ->
Text Cursor ->
Cursor Style ->
General Setup Menu
Mode ->
ID number ->
Cursor Keys ->
Power Supply ->
Communications Setup Menu
Transmit ->
Receive ->
XOFF ->
Bits ->
Parity ->
Stop Bit ->
Local Echo ->
Port ->
Transmit ->
Auto Answerback ->
Keyboard Setup Menu
Keys ->
Auto Repeat ->
Keyclick ->
Margin Bell ->
Warning Bell ->
80 Columns
Interpret Controls
No Auto Wrap
Jump Scroll
Cursor
Underline Cursor Style
VT100, 7 Bit Controls
VT100ID
Normal Cursor Keys
UPSS DEC Supplemental
2400, 4800, 9600, 19200
Receive=Transmit
XOFF at 64
8 bits
No Parity
1 Stop Bit
No Local Echo
DEC-423, Data Leads Only
Limited T r ansmit
No Auto Answerback
Typewriter Keys
any option
any option
Margin Bell
Warning Bell
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide5-5
Chapter 5: Local Management
5.3.4Telnet Connections
Once the module or chassis has a valid IP address, the user can establish a
Telnet session with Local Management from any TCP/IP based node on
the network. Telnet connections to the 6E12X-26 and 6E13X-25 require
the community name passwords assigned at the SNMP Community
Names screen of either the 6C105 chassis, or the module. For additional
information about community names, refer to Section 5.8, SNMP
Community Names Screen. Refer to the instructions included with the
Telnet application for information about establishing a Telnet session.
5-66E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Accessing Local Management
5.4ACCESSING LOCAL MANAGEMENT
Access to Local Management is controlled through the Password screen,
Figure 5-3. Whenever a connection is made to the 6E12X-26 and
6E13X-25 the Password screen displays. Before continuing, the user must
enter a password which is compared to the previously stored passwords.
The level of access allowed the user depends on the password. To set or
change passwords refer to Section 5.8. The following steps describe the
procedure to access Local Management.
1. Turn on the terminal. Press ENTER (this may take up to four times,
because the COM port of the 6E12X-26 and 6E13X-25 auto-senses the
baud rate of the terminal) until the 6C105 Local Management
Password screen, Figure 5-3, displays.
Event Message Line
Figure 5-3 Local Management Password Screen
6C105 LOCAL MANAGEMENT
CABLETRON Systems, Incorporated
P.O.Box 5005
Rochester, NH 03866-5005 USA
(603) 332-9400
(c) Copyright CABLETRON Systems, Inc, 1997
Enter Password:
1960_12
2. Enter the Password and press ENTER. The default Super-User access
password is “public” or press ENTER.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide5-7
Chapter 5: Local Management
NOTE
The User’s password is one of the community names specified
in the SNMP Community Names screen. Access to certain
Local Management capabilities depends on the degree of
access accorded that community name. Refer to Section 5.8.
•If an invalid password is entered, the terminal beeps and the cursor
returns to the beginning of the password entry field.
•Entering a valid password causes the associated access lev el to display
at the bottom of the screen and the Main Menu screen to appear.
•If no activity occurs for several minutes, the Password screen
reappears and the session ends.
5.4.1Navigating Local Management Screens
The 6E12X-26 and 6E13X-25 Local Management application consists of
a series of menu screens. Navigate through Local Management by
selecting items from the menu screens.
The 6E12X-26 and 6E13X-25 support three modes of switch operation.
The switching modes are as follows:
•802.1D SWITCHING, (traditional switching)
•802.1Q SWITCHING, (802.1Q port based VLANs)
•SECURE FAST VLAN, (Cabletron Systems SecureFast Switching)
NOTE
Refer to the Release Notes shipped with the product to verify
which screens are supported in each of the three available
switching modes.
The switch operational mode may be set in either the Chassis
Configuration screen (Section 5.7), or the General Configuration screen
of the module (Section 5.15). Depending on the Operational Mode set for
the module, the hierarchy of Local Management screens differs as shown
in Figure 5-4, Figure 5-7, and Figure 5-8. Refer to the appropriate figure
that relates to the Operational Mode that will be set for the module to see
the applicable Local Management screen hierarchy.
5-86E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Accessing Local Management
\
Password
General Configuration
SNMP Community Names
SNMP Traps
Chassis Environmental
Port Redirect Function
Module
Configuration
Menu
Module
Statistics
Menu
Network Tools
General Configuration
SNMP Community Names
SNMP Traps
Switch Configuration
Ethernet Full Duplex
Select items on a menu screen by performing the following steps:
1. Use the arrow keys to highlight a menu item.
2. Press ENTER. The selected menu item displays on the screen.
5.4.3Exiting Local Management Screens
There are two ways to exit Local Management (LM).
Using the EXIT Command
To exit an LM screen using the EXIT command, proceed as follows:
1. Use the arrow keys to highlight the EXIT command at the bottom of
the Local Management screen.
2. Press ENTER. The Password screen displays and the session ends.
5-106E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Accessing Local Management
Using the RETURN Command
1. Use the arrow keys to highlight the RETURN command at the bottom
of the Local Management screen.
2. Press ENTER. The previous screen in the Local Management
hierarchy displays.
NOTE
The user can also exit Local Management screens by pressing
ESC twice. This exit method does not warn about unsaved
changes and all unsaved changes will be lost.
3. Exit from 6E12X-26 and 6E13X-25 Local Management by repeating
steps 1 and 2 until the Main Menu screen displays.
4. Use the arrow keys to highlight the RETURN command at the bottom
of the Main Menu screen.
5. Press ENTER. The Password screen displays and the session ends.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide5-11
Chapter 5: Local Management
5.5THE MAIN MENU SCREEN
The Main Menu screen is the access point for all Local Management
screens for the module and the 6C105 chassis. Figure 5-7 shows the Main
Menu screen.
Event Message Line
6C105 LOCAL MANAGEMENT
Main Menu
CHASSIS
MODULES
EXIT
Figure 5-7 Main Menu Screen
RETURN
The following explains each Main Menu screen item as shown in
Figure 5-7:
1960_91
CHASSIS
The CHASSIS menu item provides access to the Chassis Menu screen,
shown in Figure 5-8, that is used to configure the 6C105 chassis, access
current chassis power supply and environmental status, and to configure
IEEE 802.1Q VLANs.
Access the Chassis Configuration screen by using the arrow keys to
highlight the CHASSIS menu item and pressing ENTER. The Chassis
Configuration screen displays. Proceed to Section 5.6.
5-126E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Chassis Menu Screen
MODULES
The MODULES menu item provides access to the Module Selection
screen that is used to select individual modules in the chassis for
management purposes.
Access the Module Selection screen by using the arrow keys to highlight
the MODULES menu item and pressing ENTER. The Module Selection
screen displays. Proceed to Section 5.12.
5.6CHASSIS MENU SCREEN
The Chassis Menu screen, Figure 5-8, provides access to Local
Management screens that allow you to configure and monitor operating
parameters, modify SNMP community names, set SNMP traps, monitor
the 6C105 environmental status, perform port redirect functions, and to
configure the 6C105 for IEEE 802.1Q operation.
6C105 LOCAL MANAGEMENT
Chassis Menu
CHASSIS CONFIGURATION
SNMP COMMUNITY NAMES
SNMP TRAPS
CHASSIS ENVIRONMENTAL
PORT REDIRECT FUNCTION
802.1Q VLAN CONFIGURATION
EXIT
RETURN
2269_99
Figure 5-8 Chassis Menu Screen
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide5-13
Chapter 5: Local Management
The following briefly explains each screen accessible from the Chassis
Menu screen.
CHASSIS CONFIGURATION
The Chassis Configuration screen allows the user to configure operating
parameters for the 6C105 chassis. For details, refer to Section 5.7.
SNMP COMMUNITY NAMES
The SNMP Community Names screen allows the user to enter new,
change, or review the community names used as access passwords for
device management operation. Access is limited based on the password
level of the user. For details, refer to Section 5.8.
SNMP TRAPS
The SNMP Traps screen provides display and configuration access to the
table of IP addresses used for trap destinations and associated community
names. For details, refer to Section 5.9.
CHASSIS ENVIRONMENTAL
The Chassis Environmental screen provides access to chassis power
supply status, power supply redundancy status and chassis fan tray status.
For details, refer to Section 5.10.
PORT REDIRECT FUNCTION
The Port Redirect Function screen allows the user to redirect traffic from
one or multiple modules and ports in the chassis to a specific destination
module or port. For details, refer to Section 5.11.
802.1Q VLAN CONFIGURA TION
This menu item will only display if one or more modules installed the
chassis have been configured to operate as IEEE 802.1Q switches. When
selected, this menu item opens the VLAN Main Menu screen. F or details,
refer to the Cabletron Systems Port Based VLAN User’s Guide.
Section 5.7.7, Setting the Operational Mode, describes how to
configure the modules to function as 802.1Q switches.
5-146E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Chassis Configuration Screen
5.7CHASSIS CONFIGURATION SCREEN
The Chassis Configuration screen, Figure 5-9, allows the user to set the
chassis date and time, IP address and Subnet Mask, the operational mode
of all modules installed in the chassis, and to view the chassis uptime.
Access the Chassis Configuration screen from the Chassis Menu screen
by using the arrow keys to highlight the CHASSIS CONFIGURATION
menu item and pressing ENTER. The Chassis Configuration screen,
The following briefly explains each Chassis Configuration screen field:
MAC Address (Read-Only)
Displays the base physical address of the chassis.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide5-15
Chapter 5: Local Management
IP Address (Modifiable)
This field allows the IP address to be set for the 6C105 chassis. If an IP
address is assigned to the 6C105 chassis all the interface modules
installed in the chassis can be managed via this IP address, eliminating the
need to assign an IP address to each interface module. To set the IP
address, refer to Section 5.7.1.
Subnet Mask (Modifiable)
NOTE
When a valid IP address is assigned, the Subnet Mask field
automatically enters the default mask that corresponds with
class of IP entered in the IP Address field. Some firmware
revisions do support changing the chassis subnet mask from
the default value. Refer to your Release Notes to ensure that
the Subnet Mask is a modifiable field.
Displays the subnet mask for the chassis. A subnet mask “masks out” the
network bits of the IP address by setting the bits in the mask to 1 when the
network treats the corresponding bits in the IP address as part of the
network or subnetwork address, or to 0 if the corresponding bit identifies
the host. The 6C105 chassis automatically uses the default subnet mask
that corresponds to the IP class that was entered in the IP address field.
Section 5.7.2, Setting the Subnet Mask describes how to change the
subnet mask from the default value.
Chassis Date (Modifiable)
Contains a value that the chassis recognizes as the current date. When the
chassis date is modified and saved all interface modules installed in the
chassis are set to this date. To set a new chassis date, refer to
Section 5.7.3.
Chassis Time (Modifiable)
Contains a value that the chassis recognizes as the current time. When the
chassis time is modified and saved, all interface modules installed in the
chassis are set to this time. To enter a new time, refer to Section 5.7.4.
Screen Refresh Time (Modifiable)
Contains the rate at which the screens are updated. This setting
determines how frequently (in seconds) information is updated on the
screen. To enter a new update time, refer to Section 5.7.5.
5-166E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Chassis Configuration Screen
Screen Lockout Time (Modifiable)
Contains the maximum number of minutes that the Local Management
application displays a module’s screen while awaiting input or action
from a user. For example, if the number 5 is entered in this field, the user
has up to five minutes to respond to each of the specified module’s Local
Management screens. In this example, after five minutes of “idleness” (no
input or action), the terminal “beeps” five times, the Local Management
application terminates the session, and the display returns to the Password
screen. To enter a new lockout time, refer to Section 5.7.6.
Chassis Uptime (Read-Only)
Displays the total time the chassis has been operating. The chassis uptime
is based on which interface module installed in the chassis has been
operating for the longest period of time.
Operational Mode (Toggle)
This field allows the user to set all the modules in the chassis to operate as
traditional switches (802.1D SWITCHING option), or as IEEE 802.1Q
switches (802.1Q SWITCHING option).
In 802.1D SWITCHING mode, the 24 ports located on the front panel,
and each Fast Ethernet Interface Module, and HSIM port(s) are bridged to
each other.
When the operational mode is set to 802.1Q SWITCHING, the 6E12X-26
and 6E13X-25 act as IEEE 802.1Q switches. The modules are able to
increase their switching functionality by creating and maintaining port
based Virtual LANs (VLANs).
For details on how to select the Operational Mode, refer to Section 5.7.7.
5.7.1Setting the IP Address
To set the IP address, perform the following steps:
1. Use the arrow keys to highlight the IP Address field.
2. Enter the IP address into this field using Decimal Dotted Notation
(DDN) format.
For example: 134.141.79.120
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide5-17
Chapter 5: Local Management
3. Press ENTER. If the IP address is a valid format, the cursor returns to
the beginning of the IP address field. If the entry is not valid, the Event
Message Line displays “INVALID IP ADDRESS OR FORMAT
ENTERED”. Local Management does not alter the current value and
refreshes the IP address field with the previous value.
4. Use the arrow keys to highlight the SAVE command, then press
ENTER. The “SAVED OK” message displays indicating that the
changes have been saved to memory.
5.7.2Setting the Subnet Mask
If the management workstation that is to receive SNMP traps from the
6C105 is located on a separate subnet, the subnet mask for the 6C105
must be changed from its default.
NOTE
When a valid IP address is assigned, the Subnet Mask field
automatically enters the default mask that corresponds with
class of IP entered in the IP Address field. Some firmware
revisions do support changing the chassis subnet mask from
the default value. Refer to your Release Notes to ensure that
the Subnet Mask is a modifiable field.
To change the subnet mask from its default, perform the following steps:
1. Use the arrow keys to highlight the Subnet Mask field.
2. Enter the subnet mask into this field using Decimal Dotted Notation
(DDN) format.
For example: 255.255.255.0
3. Press ENTER. If the subnet mask is valid, the cursor returns to the
beginning of the Subnet Mask field. If the entry is not valid, the Event
Message Line displays “INVALID SUBNET MASK OR FORMAT
ENTERED”. Local Management does not alter the current value, but
it does refresh the Subnet Mask field with the previous value.
4. Use the arrow keys to highlight the SAVE command, then press
ENTER. The changes are saved to memory.
5-186E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Chassis Configuration Screen
5.7.3Setting the Chassis Date
The 6C105 is year 2000 compliant, so the Chassis Date may be set
beyond the year 1999. To set the chassis date, perform the following
steps:
1. Use the arrow keys to highlight the Chassis Date field.
2. Enter the date in an MM/DD/YYYY format.
NOTE
It is not necessary to add separators between month, day, and
year numbers. For example , to set the date to 03/17/1997, type
“03171997” in the Chassis Date field.
3. Press ENTER to set the system calendar to the date in the input field.
4. Use the arrow keys to highlight the SAVE command at the bottom of
the screen and press ENTER.
If the date entered is a valid format, the Event Message Line at the top of
the screen displays “SAVED OK”. If the entry is not valid, Local
Management does not alter the current value, but it does refresh the
Chassis Date field with the previous value.
NOTE
Upon saving the new chassis date, all interface modules
installed in the chassis recognize the new value as the current
date.
5.7.4Setting the Chassis Time
To set the chassis clock, perform the following steps:
1. Use the arrow keys to highlight the Chassis Time field.
2. Enter the time in a 24-hour format, HH:MM:SS.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide5-19
Chapter 5: Local Management
NOTE
When entering the time in the system time field, separators
between hours, minutes, and seconds do not need to be added
as long as each entry uses two numeric characters. For
example, to set the time to 6:45 A.M., type “064500” in the
Chassis Time field.
3. Press ENTER to set the system clock to the time in the input field.
4. Use the arrow keys to highlight the SAVE command at the bottom of
the screen and press ENTER.
If the time entered is a valid format, the Event Message Line at the top of
the screen displays “SAVED OK”. If the entry is not valid, Local
Management does not alter the current value and refreshes the Chassis
Time field with the previous value.
NOTE
Upon saving the new chassis time, all interface modules
installed in the chassis recognize the new value as the current
time.
5.7.5Entering a New Screen Refresh Time
The screen refresh time is set from 3 to 99 seconds with a default of 3
seconds. To set a new screen refresh time, perform the following steps:
1. Use the arrow keys to highlight the Screen Refresh Time field.
2. Enter a number from 3 to 99.
3. Press ENTER to set the refresh time to the time entered in the input
field.
4. Use the arrow keys to highlight the SAVE command at the bottom of
the screen and press ENTER.
If the time entered is within the 3 to 99 seconds range, the Event Message
Line at the top of the screen displays “SAVED OK”. If the entry is not
valid, Local Management does not alter the current setting, but it does
refresh the Screen Refresh Time field with the previous value.
5-206E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Chassis Configuration Screen
5.7.6Setting the Screen Lockout Time
The screen lockout time can be set from 1 to 30 minutes with a default of
15 minutes. To set a new lockout time, perform the following steps:
1. Use the arrow keys to highlight the Screen Lockout field.
2. Enter a number from 1 to 30.
3. Press ENTER to set the lockout time in the input field.
4. Use the arrow keys to highlight the SAVE command at the bottom of
the screen and press ENTER.
If the time entered is within the 1 to 30 minutes range, the Event Message
Line at the top of the screen displays “SAVED OK”. If the entry is not
valid, Local Management does not alter the current setting, but it does
refresh the Screen Lockout Time field with the previous value.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide5-21
Chapter 5: Local Management
5.7.7Setting the Operational Mode
To set the Operational Mode, proceed as follows:
1. Use arrow keys to highlight the Operational Mode field.
2. Press the SPACE bar to step to the appropriate operation mode,
(802.1D SWITCHING or 802.1Q SWITCHING).
3. Use the arrow keys to highlight the SAVE command at the bottom of
the screen and press ENTER. The following warning screen displays:
WARNING!
YOU HAVE ELECTED TO SAVE THE OPERATIONAL MODE FOR
THE WHOLE CHASSIS. THIS WILL CAUSE ALL OF THE
BOARDS IN THE CHASSIS TO REBOOT.
ARE YOU SURE YOU WANT TO SAVE THE NEW OPERATIONAL MODE
NOYES
1666
Figure 5-10 Operational Mode Warning Screen
4. Use the arrow keys to highlight the YES command and press ENTER.
The changes are saved, and all the modules installed in the chassis
reboot.
5-226E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Chassis Configuration Screen
NOTE
If the 6E12X-26 and 6E13X-25 have been set to 802.1Q
SWITCHING, refer to your
Port Based VLAN User’s Guide
to
configure the devices for this type of operation.
The Operational Mode field in the Chassis Configuration
screen does not support the SECURE FAST VLAN operational
mode. For the modules to function as SecureFast switches,
they must have a unique IP addresses, and be configured to
act as Standalone devices in terms of Local Management via
the 6C105 chassis. Section 5.15.9 provides additional
instructions and rules that must be met before configuring the
modules as SecureFast switches.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide5-23
Chapter 5: Local Management
5.8SNMP COMMUNITY NAMES SCREEN
The SNMP Community Names menu item allows the user to set Local
Management community names. Community names act as passwords to
Local/Remote Management and provide security access to the 6C105.
Access to the 6C105 is controlled by enacting any of three different le vels
of security authorization (read-only, read-write, and super-user).
NOTE
allows existing passwords to be changed, and all modifiable
MIB objects for the Cabletron Container MIB and Internet
MIB-II to be edited.
Access the SNMP Community Names screen from the Chassis Menu
screen by using the arrow keys to highlight the SNMP COMMUNITY NAMES menu item and pressing ENTER. The SNMP Community
Names screen, Figure 5-11, displays.
Super-User access gives the user full management privileges,
Event Message Line
6C105 LOCAL MANAGEMENT
SNMP Community Names
Community Name
public
public
public
Access Policy
read-only
read-write
super-user
EXIT
RETURNSAVE
1960_97
Figure 5-11 SNMP Community Names Screen
5-246E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
SNMP Community Names Screen
The following explains each SNMP Community Names screen field:
Community Name (Modifiable)
Displays the user-defined name through which a user accesses 6C105
management. Any community name assigned here acts as a password to
Local/Remote Management.
Access Policy (Read-Only)
Indicates the access accorded each community name. Possible selections
are as follows:
read-only This community name allows read-only access
to the 6C105 MIB objects, and excludes access
to security-protected fields of read-write or
super-user authorization.
read-write This community name allows read and write
access to the 6C105 MIB objects, excluding
security protected fields for super-user access
only.
super-user This community name permits read-write
access to the 6C105
MIB objects and allows the
user to change all modifiable parameters
including community names, IP addresses,
traps, and SNMP objects.
5.8.1Establishing Community Names
The password used to access Local Management at the Password screen
must have Super-User access in order to view and edit the SNMP
Community Names screen. Using a password with read-only or
read-write access does not allow the user to view or edit the SNMP
Community Names screen.
NOTE
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide5-25
Any community name assigned in the SNMP Community
Names screen is a password to its corresponding level of
access to Local Management. The community name assigned
Super-User access is the only one that gives the user complete
access to Local Management.
Chapter 5: Local Management
NOTE
All passwords assigned in the 6C105 SNMP Community
Names screen allow access to both 6C105 Local Management
screens, and the Local Management screens of the interface
modules that are installed in the chassis. To configure the
interface module to not allow access to 6C105 Local
Management screens refer to Section 5.16.
To establish community names, proceed as follows:
1. Use the arrow keys to highlight the Community Name field adjacent
to the selected access level.
2. Enter the password in the field (maximum 31 characters).
3. Press ENTER.
4. Repeat steps 1 through 3 to modify the other community names.
5. Use the arrow keys to highlight SAVE at the bottom of the screen and
press ENTER. The message “SAVED OK” displays. The community
names are saved to memory and their access modes implemented.
5-266E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
SNMP T raps Screen
5.9SNMP TRAPS SCREEN
Since the 6C105 is an SNMP compliant device, it can send messages to
multiple Network Management Stations to alert users of status changes.
The SNMP Traps screen is shown in Figure 5-12.
Access the SNMP Traps screen from the Chassis Menu screen by using
the arrow keys to highlight the SNMP TRAPS menu item and pressing
ENTER. The SNMP Traps screen displays.
Event Message Line
Trap Destination
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
6C105 LOCAL MANAGEMENT
Chassis SNMP Traps
Trap Community Name
public
public
public
public
public
public
public
public
EXIT
Enable Traps
[YES]
[YES]
[YES]
[YES]
[YES]
[YES]
[YES]
[YES]
Figure 5-12 The SNMP Traps Screen
The following explains each field of the SNMP Traps screen.
RETURNSAVE
1960_96
Trap Destination (Modifiable)
Indicates the IP address of the workstation to receive trap alarms. Up to
eight different destinations can be defined.
Trap Community Name (Modifiable)
Displays the Community Name included in the trap message sent to the
Network Management Station with the associated IP address.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide5-27
Chapter 5: Local Management
Enable Traps (Toggle)
Enables transmission of the traps to the network management station with
the associated IP address. This field toggles between [YES] and [NO].
5.9.1Configuring the Trap Table
To configure the Trap table, proceed as follows:
1. Using the arrow keys, highlight the appropriate Trap Destination
field.
2. Enter the IP Address of the workstation that is to receive traps. IP
address entries must follow the DDN format.
For example: 134.141.79.121
3. Press ENTER. If an invalid entry is entered “INVALID IP
ENTERED” is displayed in the Event Message Line.
4. Using the arrow keys, highlight the Trap Community Name field.
Enter the community name.
5. Press ENTER.
6. Using the arrow keys, highlight the Enable Traps field. Press the
SPACE bar to choose either [YES] (send alarms from the chassis to
the workstation), or [NO] (prevent alarms from being sent).
7. Using the arrow keys, highlight the SAVE command and press
ENTER. The message “SAVED OK” displays on the screen.
NOTE
Exiting without saving causes a “NOT SAVED?” message to
appear above the SAVE command. Edits will be lost if they are
not saved before exiting.
The designated workstations now receive traps from the 6C105.
5-286E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Chassis Environmental Screen
5.10CHASSIS ENVIRONMENTAL SCREEN
The Chassis Environmental menu item allows the user to view chassis
environmental information.
Access the Chassis Environmental Information screen from the Chassis
Menu screen by using the arrow keys to highlight the CHASSIS ENVIRONMENTAL menu item and pressing ENTER. The Chassis
Environmental Information screen, Figure 5-13, displays.
6C105 LOCAL MANAGEMENT
Chassis Environmental Information
Chassis Power Redundancy
Power Supply #1 Status
Power Supply #2 Status
Chassis Fan Status
EXIT
Not Available
Normal
Not Installed
Normal
RETURN
1960_94
Figure 5-13 Chassis Environmental Information Screen
The following describes each of the Chassis Environmental Information
screen fields.
Chassis Power Redundancy (Read-Only)
Displays the current redundancy status of the 6C105 power supplies. This
field will read either “Available” or “Not Available”.
Power Supply #X Status (Read-Only)
Displays the current status of power supplies 1 and 2 for the 6C105. This
field will read either “Normal”, “Fault”, or “Not Installed”.
Chassis Fan Status (Read-Only)
Displays the current status of the 6C105 fan tray. This field will read
either “Normal”, “Fault”, or “Not Installed”.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide5-29
Chapter 5: Local Management
5.11PORT REDIRECT FUNCTION SCREEN
NOTE
The Port Redirect Function screen may not be available
depending on the operational mode that has been set for the
chassis. Refer to your Release Notes to see what operational
modes support the Port Redirect Function. Refer to
Section 5.7.7, Setting the Operational Mode, for instructions
on configuring the operational mode of all the modules installed
in the chassis.
The Port Redirect Function screen, Figure 5-14, allows the user to set
each one of the modules in the chassis (1 through 5), and the ports of the
corresponding module installed, as a source or destination port. A port
can be set to have one or more destination ports and chassis module slot
numbers. For example, port 1 in module (slot) 1 can be set as a source
port with three destinations, ports 2, 3, and 4 in module (slot) 3. Traffic
from port 1 in module 1 is then automatically redirected to ports 2, 3, and
4 in module 3. Port 1 in module 1 can also serve as a destination port for
other ports and modules. The port redirect function is extremely useful for
troubleshooting purposes, as it allows traffic to be sent to a particular
port(s) where, with the use of an analyzer or RMON probe, all current
traffic from the source port(s) can be examined.
NOTES
The module number corresponds to the slot number in which
the module resides in the 6C105 chassis (1 through 5).
Although traffic from the source port (including, if desired,
errored frames) is sent to the destination port, normal switching
is still performed for all frames on the source port.
Access the Port Redirect Function screen from the Chassis Menu screen
by using the arrow keys to highlight the PORT REDIRECT FUNCTION menu item and pressing ENTER. The Port Redirect
Function screen, Figure 5-14, displays.
5-306E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Port Redirect Function Screen
Event Message Line
Module
1
1
1
2
2
3
3
3
SAVE
SourceDestinationRemap Errors
====================================
Source Port [1]
Source Module [1]
EXIT
6C105 LOCAL MANAGEMENT
Port Redirect Function
Port
1
1
1
2
2
3
3
3
Module
3
3
3
1
3
4
5
5
Destination Port [1]
Destination Module [1]
NEXT
Port
2
3
4
1
3
4
5
8
PREVIOUS
ON
ON
ON
OFF
ON
ON
ON
OFF
Status [ADD]
Errors [ON]
RETURN
RETURN
1960_66
Figure 5-14 Port Redirect Function Screen
The following definitions briefly explain each field of the Port Redirect
Function screen.
Source Module (Read-Only)
Displays which modules are currently set as source modules.
Source Port (Read-Only)
Displays which ports are currently set as source ports.
Destination Module (Read-Only)
Displays which modules are currently set as destination modules.
Destination Port (Read-Only)
Displays which ports are currently set as destination ports.
Remap Errors (Read-only)
Displays whether the corresponding source modules and ports are
configured to send errored frames to the destination modules and ports, or
to drop all errored frames before forwarding traffic.
Source Module [n] (Selectable)
Allows a selected module [n] to be configured as a source module.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide5-31
Chapter 5: Local Management
Source Port [n] (Selectable)
Allows a selected port [n] to be configured as a source port.
Destination Module [n] (Selectable)
Allows a selected module [n] to be configured as a destination module.
Destination Port [n] (Selectable)
Allows a selected port [n] to be configured as a destination port.
Errors (Toggle)
Allows the user to configure the source modules and ports to either send
errored frames to selected destination modules and ports ([ON] option),
or to drop errored frames, and send only valid traffic to the destination
modules and ports ([OFF] option). The default setting of this field is
[ON].
Status (Toggle)
Allows the user to add or delete the source/destination modules and ports
selected in the Source/Destination Modules and ports fields.
5.11.1Displaying the Source and Destination Entries
There can be more than one Port Redirect Function screen depending on
the number of port redirect entries. Each screen displays up to ten port
redirect entries. If there is more than one screen of redirect entries, the
NEXT and/or PREVIOUS command is displayed at the bottom of the
screen, allowing the user to navigate to the next or previous screen.
To display the next screen, use the arrow keys to highlight NEXT. Press
ENTER and the next screen of entries is displayed.
To display the previous screen, use the arrow keys to highlight
PREVIOUS. Press ENTER to view the entries in the previous screen.
5-326E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Port Redirect Function Screen
5.11.2Changing Source and Destination Ports
Add or delete source/destination module and port entries as follows:
1. Use the arrow keys to highlight the Source Module field.
2. Press the SPACE bar or BACKSPACE one or more times to increment
or decrement the module number displayed in the brackets [n] until the
appropriate module number is displayed.
3. Use the arrow keys to highlight the Source Port field.
4. Press the SPACE bar or BACKSPACE one or more times to increment
or decrement the port number displayed in the brackets [n] until the
appropriate port number is displayed.
5. Use the arrow keys to highlight the Destination Module field.
6. Use the SPACE bar or BACKSPACE to step to the appropriate
module number for the destination module.
7. Use the arrow keys to highlight the Destination Port field.
8. Use the SPACE bar or BACKSPACE to step to the appropriate port
number for the destination port.
9. Use the arrow keys to highlight the Status field.
10. Use the SPACE bar to select either the [ADD] or [DEL] (delete)
option. Press ENTER. This adds or deletes the selections made in steps
2 and 4 and also updates the screen Source Module, Source Port,
Destination Module and Destination Port lists.
11. Use the arrow keys to highlight the Errors field.
12. Use the SPACE bar to select either the [ON] or [OFF] option and
press ENTER. [ON] forces the source module and port to forward
errored frames to the destination module(s) and port(s). [OFF] forces
the errored frames to be dropped before forwarding traffic.
NOTE
If more than one module and port is to be redirected, repeat
steps 1 through 12 for each additional setting, then go to step
13 to save all the new settings at once.
13. Use the arrow keys to highlight SAVE at the bottom of the screen.
Press ENTER. The message “SAVED OK” is displayed.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide5-33
Chapter 5: Local Management
5.12MODULE SELECTION SCREEN
The Module Selection screen is the access point to Local Management for
all modules installed in the SmartSwitch 6000 chassis. By selecting a
module, the Module Menu for the selected device displays. Figure 5-15
shows the Module Selection screen.
6E122-26 LOCAL MANAGEMENT
Module Selection
Module #
<1>
2
3
4
5
Module Type
6E122-26
6E132-25
6E123-26
6E122-26
123456789
123456789
123456789
123456789
EXIT
Serial #
Hardware Revision
XXX
XXX
XXX
XXX
RETURN
Figure 5-15 Module Selection Screen
The following explains each Module Selection screen field as shown in
Figure 5-15.
Module #
The Module # field displays the slot in which the module is installed. The
module number enclosed in < > characters indicates the module to which
the management terminal or Telnet session is connected.
Module Type
The Module Type field displays the type of interface module that is
installed in each slot.
5-346E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Module Selection Screen
Serial #
Indicates the serial number of the module. The serial number of the device
is necessary when calling the Cabletron Systems Global Call Center.
Hardware Revision
Reflects the hardware version of the module.
5.12.1Selecting a Module
To select an individual module to perform Local Management functions,
proceed as follows:
1. Use the arrow keys to highlight the desired module number in the
Module # field.
2. Press ENTER, the applicable Module Menu screen displays. Proceed
to Section 5.13.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide5-35
Chapter 5: Local Management
5.13MODULE MENU SCREEN
NOTE
the 6E122-26. The 6E132-25, 6E133-25 and 6E123-26 share
most of the following Local Management screens. All Local
Management functions specific to any interface module are
preceded by a note to alert the reader.
The 6E12X-26 and 6E13X-25 Module Menu screens are the access point
for all Local Management screens for the 6E12X-26 and 6E13X-25.
Figure 5-16 shows the 6E122-26 Module Menu screen.
6E122-26 LOCAL MANAGEMENT
Module Menu
The Local Management screens shown in this chapter are for
5-366E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Module Menu Screen
The following explains each Module Menu screen field as shown in
Figure 5-16:
MODULE CONFIGURATION
The Module Configuration screen provides access to the Local
Management screens that are used to configure the 6E12X-26 and
6E13X-25. The Module Specific Configuration Menu screen provides
access to the screens that allow the user to check 6E12X-26 and
6E13X-25 resources and set operating parameters specific to each port.
For details about the Module Configuration Menu screen, refer to
Section 5.14. For details about the Module Specific Configuration Menu
screen, refer to Section 5.20.
MODULE STATISTICS
The Module Statistics screen provides statistics and performance
information for the 6E12X-26 and 6E13X-25. For details about this
screen, refer to Section 5.26.
NETWORK TOOLS
The Network Tools function resides on the 6E12X-26 and 6E13X-25 and
consists of a series of commands that allow the user to access and manage
network devices. Section 5.30 explains how to use the Network Tools
utility.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide5-37
Chapter 5: Local Management
5.14MODULE CONFIGURATION MENU SCREEN
The Module Configuration Menu screen, Figure 5-17, provides access to
Local Management screens that allow you to configure and monitor
operating parameters, modify SNMP community names, set SNMP traps,
configure switch parameters and configure 6E12X-26 and 6E13X-25
ports.
NOTE
The following menu items on the Module Configuration Menu
screen may not display if the operational mode of the module
has been set to SECURE FAST VLAN:
SWITCH CONFIGURATION
SMARTTRUNK CONFIGURATION
Refer to your Release Notes to see if the functionality provided
by the above screens is supported in SECURE FAST VLAN
mode.
Section 5.15.9 provides instructions on setting the operational
mode.
Access the Module Configuration Menu screen from the Module Menu
screen by using the arrow keys to highlight the MODULE CONFIGURATION menu item and pressing ENTER. The Module
Configuration screen displays.
5-386E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
SNMP COMMUNITY NAMES
SNMP TRAPS
SWITCH CONFIGURATION
ETHERNET FULL DUPLEX CONFIGURATION
SMARTTRUNK CONFIGURATION
MODULE SPECIFIC CONFIGURATION
RETURNEXIT
1960_42
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide5-39
Chapter 5: Local Management
The following briefly explains each screen accessible from the Module
Configuration Menu screen:
GENERAL CONFIGURATION
The General Configuration screen allows the user to monitor and
configure operating parameters for the 6E12X-26 and 6E13X-25. For
details, refer to Section 5.15.
SNMP COMMUNITY NAMES
The SNMP Community Names screen allows the user to enter new,
change, or review the community names used as access passwords for
Local/Remote management operation. Access is limited based on the
password level of the user. For details, refer to Section 5.16.
SNMP TRAPS
The SNMP Traps screen provides display and configuration access to the
table of IP addresses used for trap destinations and associated community
names. For details, refer to Section 5.17.
SWITCH CONFIGURATION
The Switch Configuration screen provides basic setup options for
modifying the switching functions of the modules. For details, refer to
Section 5.18.
ETHERNET FULL DUPLEX CONFIGURATION
The Ethernet Full Duplex Configuration screen allows each 10 Mbps port
(1 to 24) to be set for either Standard Ethernet or Full Duplex operation.
The screen also indicates whether or not each port is linked to another
Ethernet device and if that port is enabled. For details, refer to
Section 5.19.
SMARTTRUNK CONFIGURATION
The SmartTrunk Configuration screen allows the user to logically group
interfaces together to create a greater bandwidth uplink. Refer to the
Cabletron Systems SmartTrunk User’s Guide for additional information.
MODULE SPECIFIC CONFIGURATION
The Module Specific Configuration Menu screen allows the user to
configure ports or check system resources specific to the 6E12X-26 and
6E13X-25. For details, refer to Section 5.20.
5-406E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
General Configuration Screen
5.15GENERAL CONFIGURATION SCREEN
The General Configuration screen, Figure 5-18, allows the user to set the
system date and time, IP address and subnet mask, the default gateway,
the TFTP Gateway IP address, the Operational Mode, the Management
Mode, and the COM port configuration. The General Configuration
screen also allows the user to Clear NVRAM, and enable or disable IP
Fragmentation.
Access the General Configuration screen from the Module Configuration
Menu screen by using the arrow keys to highlight the GENERAL CONFIGURATION menu item and pressing ENTER. The General
Configuration screen, Figure 5-18, displays.
Event Message Line
Module Type: 6E122-26
Slot Number:
MAC Address:
IP Address:
Subnet Mask:
Default Gateway:
TFTP Gateway IP Addr:
Module Date:
Module Time:
Screen Refresh Time:
Screen Lockout Time:
Module Uptime XX D XX H XX M
10/11/97
14:23:00
30 sec.
15 min.
RETURNSAVE
1960_15
Figure 5-18 General Configuration Screen
The following briefly explains each General Configuration screen field:
MAC Address (Read-Only)
Displays the base physical address of the module.
IP Address (Modifiable)
This display allows the IP address to be set for the 6E12X-26 and
6E13X-25. To set the IP address, refer to Section 5.15.1.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide5-41
Chapter 5: Local Management
Subnet Mask (Modifiable)
Displays the subnet mask for the module. A subnet mask “masks out” the
network bits of the IP address by setting the bits in the mask to 1 when the
network treats the corresponding bits in the IP address as part of the
network or subnetwork address, or to 0 if the corresponding bit identifies
the host. When an IP address is entered in the IP Address field, the subnet
mask field automatically enters the default subnet mask for the IP address.
For details about how to change the subnet mask from its default value,
refer to Section 5.15.2.
Default Gateway (Modifiable)
Displays the default gateway for the 6E12X-26 and 6E13X-25. This field
is not defined until an appropriate value is entered. For details about why
and how to set the Default Gateway, refer to Section 5.15.3.
TFTP Gateway IP Addr (Modifiable)
Displays and allows the user to set the TFTP Gateway IP address for the
6E12X-26 and 6E13X-25. To set the TFTP Gateway IP address, refer to
Section 5.15.4.
Module Date (Modifiable)
Contains a value that the module recognizes as the current date. To set a
new module date, refer to Section 5.15.5.
Module Time (Modifiable)
Contains a value that the module recognizes as the current time. To enter a
new time, refer to Section 5.15.6.
Screen Refresh Time (Modifiable)
Contains the rate at which the screens are updated. This setting
determines how frequently (in seconds) information is updated on the
screen. To enter a new update time, refer to Section 5.15.7.
5-426E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
General Configuration Screen
Screen Lockout Time (Modifiable)
Contains the maximum number of minutes that the Local Management
application displays a module’s screen while awaiting input or action
from a user. For example, if the number 5 is entered in this field, the user
has up to five minutes to respond to each of the specified module’s Local
Management screens. In this example, after five minutes of “idleness” (no
input or action), the terminal “beeps” five times, the Local Management
application terminates the session, and the display returns to the Password
screen. To enter a new lockout time, refer to Section 5.15.8.
Module Uptime (Read-Only)
Displays the total time that the module has been operating.
Operational Mode (Modifiable)
This field allows the user to set the 6E12X-26 and 6E13X-25 to operate as
a traditional switch (802.1D SWITCHING option), an IEEE 802.1Q
switch (802.1Q SWITCHING option), or as a Cabletron Systems
SecureFast switch (SECURE FAST VLAN option).
In 802.1D SWITCHING mode, the 24 ports located on the front panel,
and each Fast Ethernet Interface Module, and HSIM port(s) are bridged to
each other.
In 802.1Q SWITCHING mode, the 6E12X-26 and 6E13X-25 are able to
increase their switching functionality by creating and maintaining IEEE
port based VLANs.
When the operational mode is set to SECURE FAST VLAN, the
6E12X-26 and 6E13X-25 act as SecureFast switches. With the Cabletron
Systems VLAN Manager software, the modules are able to increase their
switching functionality by creating and maintaining Virtual LANs
(VLANs).
For details on how to select the Operational Mode, refer to Section 5.15.9.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide5-43
Chapter 5: Local Management
Management Mode (Toggle)
This field toggles between DISTRIBUTED and STAND ALONE.
In DISTRIBUTED mode, Local Management is entered via the 6C105
password screen, and all chassis configuration screens are available to the
user. All other modules installed in the chassis that are set for distributed
management may also be accessed via a connection to a single COM port
on one of the modules.
In STAND ALONE mode, the module is isolated from the chassis
configuration screens, and the module may not be accessed from a module
that is in DISTRIBUTED mode. This provides additional security for any
module to which the user may wish to restrict access.
Section 5.15.10
describes how to set the Management Mode.
Com (Toggle)
This field allows the user to enable or disable the COM port. The
selection toggles between ENABLED and DISABLED. The default is
ENABLED. For details about setting up the COM port, refer to
Section 5.15.11.
Application (Modifiable)
Displays the application set for the COM port. This field allows you to set
the application that the COM port will support, which includes:
•Local Management (LM) via a terminal or modem connection
•Uninterruptible Power Supply (UPS)
The UPS setting allows you to use the COM port to monitor an American
Power Conversion Uninterruptible Power Supply (UPS). For UPS, the
baud rate is automatically set to 2400.
The baud rate setting for LM is automatically sensed.
For details about how to configure the COM port for v arious applications,
refer to Section 5.15.11.
5-446E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
General Configuration Screen
Clear NVRAM (Toggle)
This allows the user to reset NVRAM to the factory default settings. All
user-entered parameters, such as IP address and Community Names are
then replaced with 6E12X-26 and 6E13X-25 default configuration
settings. For details, refer to Section 5.15.13.
IP Fragmentation (Toggle)
This field allows the user to enable or disable IP fragmentation. The
default setting for this field is ENABLED. If the 6E12X-26 or 6E13X-25
will be bridged to an FDDI ring, IP Fragmentation should be enabled. If
IP Fragmentation is disabled, all FDDI frames that exceed the maximum
Ethernet frame size will be discarded. For details on enabling or disabling
IP Fragmentation refer to Section 5.15.14.
5.15.1Setting the IP Address
To set the IP address, perform the following steps:
NOTE
If the 6C105 chassis has been assigned an IP address, it is not
necessary to assign an IP address to the 6E12X-26 and
6E13X-25. All installed modules have the same IP address as
the chassis. If a separate IP address for the module is desired,
proceed as follows.
1. Use the arrow keys to highlight the IP Address field.
2. Enter the IP address into this field using Decimal Dotted Notation
(DDN) format.
For example: 134.141.79.120
3. Press ENTER. If the IP address is a valid format, the cursor returns to
the beginning of the IP address field. If the entry is not valid, the Event
Message Line displays “INVALID IP ADDRESS OR FORMAT
ENTERED”. Local Management does not alter the current value and
refreshes the IP address field with the previous value.
4. Use the arrow keys to highlight the SAVE command, then press
ENTER. The warning screen shown in Figure 5-19 displays.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide5-45
Chapter 5: Local Management
WARNING!
YOU HAVE ELECTED TO SAVE ONE OR MORE CONFIGURATION
ITEMS THAT REQUIRE RESETTING THIS MODULE.
ARE YOU SURE YOU WANT TO CONTINUE?
YES
Figure 5-19 Configuration Warning Screen
NO
174252
5. Use the arrow keys to highlight the YES command and Press ENTER.
The changes are saved and the module reboots.
5.15.2Setting the Subnet Mask
If the management workstation that is to receive SNMP traps from the
6E12X-26 and 6E13X-25 is located on a separate subnet, the subnet mask
for the 6E12X-26 and 6E13X-25 must be changed from its default.
To change the subnet mask from its default, perform the following steps:
1. Use the arrow keys to highlight the Subnet Mask field.
2. Enter the subnet mask into this field using Decimal Dotted Notation
(DDN) format.
For example: 255.255.255.0
5-466E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
General Configuration Screen
3. Press ENTER. If the subnet mask is valid, the cursor returns to the
beginning of the Subnet Mask field. If the entry is not valid, the Event
Message Line displays “INVALID SUBNET MASK OR FORMAT
ENTERED”. Local Management does not alter the current value, but
it does refresh the Subnet Mask field with the previous value.
4. Use the arrow keys to highlight the SAVE command, then press
ENTER. The warning screen shown in Figure 5-19 displays.
5. Use the arrow keys to highlight the YES command and press ENTER.
The changes are saved and the module reboots
5.15.3Setting the Default Gateway
If the SNMP management station is located on a different IP subnet than
the 6E12X-26 and 6E13X-25, a default gateway must be specified. When
an SNMP Trap is generated, the 6E12X-26 and 6E13X-25 sends the Trap
to the default gateway. To set the default gateway, perform the following
steps:
1. Use the arrow keys to highlight the Default Gateway field.
2. Enter the IP address of the default gateway using the DDN format.
For example: 134.141.79.121
3. Press ENTER. If the default gateway entered is a valid format, the
cursor returns to the beginning of the Default Gateway field. If the
entry is not valid, the Event Message Line displays “INVALID
DEFAULT GATEWAY OR FORMAT ENTERED”. Local
Management does not alter the current value, but it does refresh the
Default Gateway field with the previous value.
4. Use the arrow keys to highlight the SAVE command.
5. Press ENTER. The Event Message Line at the top of the screen
displays “SAVED OK”.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide5-47
Chapter 5: Local Management
5.15.4Setting the TFTP Gateway IP Address
If the network TFTP server is located on a different IP subnet than the
6E12X-26 and 6E13X-25, a Gateway IP address should be specified. To
set the TFTP Gateway IP address, perform the following steps:
1. Use the arrow keys to highlight the TFTP Gateway IP Address field.
2. Enter the IP address of the TFTP gateway using the DDN format.
For example: 134.141.80.122
3. Press ENTER. If the TFTP gateway IP address entered is a valid
format, the cursor returns to the beginning of the TFTP Gateway IP
Address field. If the entry is not valid, the Event Message Line
displays “INVALID TFTP GATEWAY IP ADDRESS OR FORMAT
ENTERED”. Local Management does not alter the current value, but
it does refresh the TFTP Gateway IP Address field with the previous
value.
4. Use the arrow keys to highlight the SAVE command.
5. Press ENTER. The Event Message Line at the top of the screen
displays “SAVED OK”.
5.15.5Setting the Module Date
The modules are year 2000 compliant, so the module date may be set
beyond the year 1999. To set the module date, perform the following
steps:
NOTE
1. Use the arrow keys to highlight the Module Date field.
2. Enter the date in an MM/DD/YYYY format.
NOTE
5-486E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
If the 6C105 chassis has been assigned a chassis date, it is not
necessary to assign a module date to the 6E12X-26 and
6E13X-25. All installed modules recognize the chassis date of
the 6C105.
It is not necessary to add separators between month, day, and
year numbers. For example , to set the date to 03/17/1997, type
“03171997” in the Module Date field.
General Configuration Screen
3. Press ENTER to set the system calendar to the date in the input field.
4. Use the arrow keys to highlight the SAVE command at the bottom of
the screen and press ENTER.
If the date entered is a valid format, the Event Message Line at the top of
the screen displays “SAVED OK”. If the entry is not valid, Local
Management does not alter the current value, but it does refresh the
Module Date field with the previous value.
5.15.6Setting the Module Time
To set the module clock, perform the following steps:
NOTE
If the 6C105 chassis has been assigned a chassis time, it is not
necessary to assign a module time to the 6E12X-26 and
6E13X-25. All installed modules recognize the chassis time of
the 6C105.
1. Use the arrow keys to highlight the Module Time field.
2. Enter the time in an 24-hour format, HH:MM:SS.
NOTE
When entering the time in the system time field, separators
between hours, minutes, and seconds do not need to be added
as long as each entry uses two numeric characters. For
example, to set the time to 6:45 A.M., type “064500” in the
Module Time field.
3. Press ENTER to set the system clock to the time in the input field.
4. Use the arrow keys to highlight the SAVE command at the bottom of
the screen and press ENTER.
If the time entered is a valid format, the Event Message Line at the top of
the screen displays “SAVED OK”. If the entry is not valid, Local
Management does not alter the current value and refreshes the Module
Time field with the previous value.
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide5-49
Chapter 5: Local Management
5.15.7Entering a New Screen Refresh Time
The screen refresh time is set from 3 to 99 seconds with a default of 3
seconds. To set a new screen refresh time, perform the following steps:
1. Use the arrow keys to highlight the Screen Refresh Time field.
2. Enter a number from 3 to 99.
3. Press ENTER to set the refresh time to the time entered in the input
field.
4. Use the arrow keys to highlight the SAVE command at the bottom of
the screen and press ENTER.
If the time entered is within the 3 to 99 seconds range, the Event Message
Line at the top of the screen displays “SAVED OK”. If the entry is not
valid, Local Management does not alter the current setting, but it does
refresh the Screen Refresh Time field with the previous value.
5.15.8Setting the Screen Lockout Time
The screen lockout time can be set from 1 to 30 minutes with a default of
15 minutes. To set a new lockout time, perform the following steps:
1. Use the arrow keys to highlight the Screen Lockout Time field.
2. Enter a number from 1 to 30.
3. Press ENTER to set the lockout time in the input field.
4. Use the arrow keys to highlight the SAVE command at the bottom of
the screen and press ENTER.
If the time entered is within the 1 to 30 minutes range, the Event Message
Line at the top of the screen displays “SAVED OK”. If the entry is not
valid, Local Management does not alter the current setting, but it does
refresh the Screen Lockout Time field with the previous value.
5-506E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
General Configuration Screen
5.15.9Setting the Operational Mode
Before setting the operational mode, ensure that the items
contained in this caution are fully understood.
!
CAUTION
If the module will be configured to operate as a SecureFast
switch the following procedures should be performed before
setting the operational mode:
The module must be assigned a unique IP address.
The Management Mode of the module will automatically be set
to STANDALONE. The Management Mode field will no longer
display on the General Configuration screen, and the module
will no longer support Chassis configuration and Module
selection screens. If the module will be a SecureFast switch,
distributed management is not allowed.
The module has been assigned SNMP community names from
the module SNMP Community Names screen (Section 5.16).
In Standalone management mode, the module does not use
the community names of the 6C105 chassis.
To set the Operational Mode, proceed as follows:
1. Use arrow keys to highlight the Operational Mode field.
2. Press the SPACE bar to step to the appropriate operation mode,
(802.1D SWITCHING, 802.1Q SWITCHING, or SECURE FAST
VLAN).
3. Use the arrow keys to highlight the SAVE command, then press
ENTER. The warning screen shown in Figure 5-19 displays.
4. Use the arrow keys to highlight the YES command and press ENTER.
The changes are saved and the module reboots.
NOTE
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide5-51
Upon saving the new operational mode, the module will reboot.
If the 6E12X-26 and 6E13X-25 have been set to 802.1Q
SWITCHING, refer to your
configure the devices for this type of operation.
If the 6E12X-26 and 6E13X-25 have been set to SECURE F AST VLAN, refer to your SecureFast documentation set to
configure the devices for this type of operation.
Port Based VLAN User’s Guide
to
Chapter 5: Local Management
5.15.10 Setting the Management Mode
To set the management mode, perform the following steps:
NOTE
Upon saving the new Management Mode, the module will
reboot.
If the module will be set to STANDALONE, ensure the f ollowing
procedures have been completed:
The module has been assigned a unique IP address.
The module has been assigned SNMP community names from
the module SNMP Community Names screen (Section 5.16).
In STAND ALONE management mode, the module does not
use the community names of the 6C105 chassis.
1. Use the arrow keys to highlight the Management Mode field:
2. Use the SPACE bar to toggle the options (DISTRIBUTED or
STAND ALONE) until the desired mode displays.
3. Use the arrow keys to highlight the SAVE command, then press
ENTER. The warning screen shown in Figure 5-19 displays.
4. Use the arrow keys to highlight the YES command and press ENTER.
The changes are saved and the module reboots.
5-526E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide