CABELCON CC 99909946-01 Datasheet

Further technical specifications and installation instructions can be obtained on request.
Datasheet
Item no.
Frequency Range Impedance (Nom.) Amp. Rating (measured) (calculated)
Transfer Impedance (CoMeT) <2.5 mΩ/m @ 5-30MHz <0.68 mΩ/item @ 5-30MHz Screening Attenuation(CoMeT) >105 dB @ 30-1000MHz >95 dB @ 1000-2000MHz
>85 dB @ 2000-3000MHz
Return Loss (IEC 61169-1)
0.3 - 500 MHz -37 dB -39.5 dB 500 - 860 MHz -36 dB -38.6 dB 860 - 1000 MHz -35 dB -37.9 dB 1000 - 1750 MHz -32 dB -35.1 dB 1750 - 2150 MHz -32 dB -35.0 dB 2150 - 3000 MHz -25 dB -29.3 dB
Temperature Installing -5° to +50° C Operating -40° to +70° C Storing -40° to +70° C
Sealing Test (IEC IP-code) IP X8 30 meter / 8 hours
O-rings EPDM
Base Material Body Parts Brass CuZn39Pb3 Inner Conductor Cable data
Plating Body Parts Nitin-6 Inner Conductor Cable data
Insulators Cabel data
Remarks
* Not Able To Measure(NATM): The cable starts to twist without the connector loosing its grip.
99909946-01 Connector type
For cable
0.3 - 3000 MHz
75 Ohm
Cable data
Cable data
Class A+
Class A++
Better than Typical
Product photo
Insertion Loss Max. Better than Typical
0.3 - 500 MHz -0.06 dB -0.01 dB 500 - 860 MHz -0.06 dB -0.01 dB 860 - 1000 MHz -0.06 dB -0.01 dB 1000 - 1750 MHz -0.06 dB -0.01 dB 1750 - 2150 MHz -0.06 dB -0.01 dB 2150 - 3000 MHz -0.06 dB -0.01 dB
Intermodulation IM3 3rd Order (@2*0.2W) -155 dBc
Inner Conductor Resistance (@ 1 A DC) Cable data
Insulation Resistance (@ 500 VDC) Cable data
Dielectric Strength DC Test Voltage Cable data
Max. Tensile Strength Overall >23 Kgf >226 N
Torsional Strength (Connector / Cable) * NATM
Test performed by Susanne Lindharth Date of release May 29, 2019
HQ 113 (1.1/4.8) PE Class A+
F-6-TD 5.1
Connector designed according to the standard IEC 61169-24 (type F)
All tests performed using instruments calibrated in accordance to our ISO 9001 certification.
© Copyright Corning Optical Communications ApS – 2015 ISO 9001:2008 / ISO 14001 certified
Distributor:
Corning Optical Communications ApS Industriparken 10, DK-4760 Vordingborg, Denmark Tel: +45 55 98 55 99 Fax: +45 55 98 55 04 cabelcon@corning.com www.cabelcon.dk Form 041 rev 18
O:\TestAfd\Corning data sheets\99909 946-01 F-6-TD 5.1\Ören, HQ 113 (1.1_4.8) PE Class A+\ Documentation\99909946 - Datablad Test Ske ma1 rev2019.docm
Corning Public
Loading...