Bedienungsanleitung
Manuel d‘utilisation
Operating Instructions
Type 6013
Magnetventil
2/2-Way Solenoid Valve
2/2-Wege Magnetventil
Électrovanne à 2/2 voies
Address / Adresse
Germany / Deutschland / Allemagne
Bürkert Fluid Control Systems
Sales Center
Christian-Bürkert-Str. 13-17
D-74653 Ingelfingen
Tel. + 49 (0) 7940 - 10 91 111
Fax + 49 (0) 7940 - 10 91 448
E-mail: info@de.buerkert.com
International
www.burkert.com → Bürkert → Company → Locations
Manuals and data sheets on the Internet:
www.burkert.com
Bedienungsanleitungen und Datenblätter im Internet:
www.buerkert.de
Manuel d'utilisation et fiches techniques sur Internet :
www.buerkert.fr
2
2 INTENDED USE
Incorrect use of the solenoid valve Type 6013 can be dangerous
to people, nearby equipment and the environment.
▶ The device is designed for blocking, dosing, filling and venting neutral
gaseous and liquid media.
▶ In the potentially explosion-risk area the device may be used only
according to the specification on the separate Ex type label. For use
observe the additional information enclosed with the device together
with safety instructions for the explosion-risk area.
▶ Devices without a separate Ex type label may not be used in a poten-
tially explosive area.
▶ Use according to the permitted data, operating conditions and
conditions of use specified in the contract documents and operating instructions.
▶ The device may be used only in conjunction with third-party devices
and components recommended and authorised by Bürkert.
▶ Correct transportation, correct storage and installation and careful
use and maintenance are essential for reliable and problem-free
operation.
▶ Use the device only as intended.
1 OPERATING INSTRUCTIONS
The operating instructions contain important information.
▶ Read the instructions carefully and follow the safety instructions in
particular, and also observe the operating conditions.
▶ Instructions must be available to each user.
▶ The liability and warranty for Type 6013 are void if the operating
instructions are not followed.
1.1 Symbols
▶ Designates an instruction to prevent risks.
→ designates a procedure which you must carry out.
Warning of injuries:
DANGER!
Imminent danger! Serious or fatal injuries.
WARNING!
Potential danger! Serious or fatal injuries.
CAUTION!
Danger! Minor or moderately severe injuries.
Warns of damage to property:
NOTE!
english
3
2.1 Restrictions
If exporting the system/device, observe any existing restrictions.
2.2 Definition of term
In these operating instructions, the term “device” always refers to the
solenoid valve Type 6013.
3 BASIC SAFETY INSTRUCTIONS
These safety instructions do not make allowance for any contingencies and events which may arise during installation, operation and
maintenance.
Danger – high pressure!
▶ Before loosening the lines and valves, turn off the pressure and
vent the lines.
Risk of electric shock!
▶ Before reaching into the system, switch off the power supply and
secure to prevent reactivation!
▶ Observe applicable accident prevention and safety regulations for
electrical equipment!
Risk of burns/risk of fire!
During continuous operation the surface of the device may become hot.
▶ Keep the device away from highly flammable substances and media
and do not touch the device with bare hands.
▶ Do not obstruct the heat release required for operation.
english
© Bürker t Werke GmbH & Co. KG, 201 - 2017
Operating Instructions 1706/_(8(1_008 / Original DE

4
Destruction of the coil by overheating!
▶ Connect the coil electrically only when the housing has been installed.
In the case of AC voltage pay attention to movable core.
To prevent injury, ensure that:
▶ Do not supply the medium connectors of the system with aggressive
or flammable mediums.
▶ Do not make any external modifications to the device bodies. Ensure
that the system cannot be activated unintentionally.
▶ Installation and repair work may be carried out by authorized techni-
cians only and with the appropriate tools.
▶ After an interruption in the power supply or pneumatic supply, ensure
that the process is restarted in a defined or controlled manner.
▶ Do not put any loads on the body.
▶ Observe the general regulations of technology.
4 TECHNICAL DATA
4.1 Conformity
In accordance with the EC Declaration of conformity, the solenoid
valve Type 6013 is compliant with the EC Directives (if applicable).
4.2 Standards
The applied standards, which verify conformity with the EC Directives,
can be found on the EC-Type Examination Certificate and / or the EC
Declaration of Conformity (if applicable).
4.3 Operating conditions
WARNING!
Heat sources and temperature fluctuations may cause malfunctions or leaks!
▶ If the device is used outdoors, do not expose it unprotected to the
weather conditions.
▶ Avoid heat sources which may cause the allowable temperature
range to be exceeded.
english
5
Medium temperature:
Operating
principles
Sealing material Medium temperature
CFA FKM -10 ... +100 °C (PA Coil)
-10 ... +120 °C (Epoxide Coil)
PTFE/Graphite -10 ... +180 °C
CFB FKM -10 ... +100 °C (AC)
-10 ... +120 °C (DC)
Ambient temperature: -10 ... +55 °C
Viscosity: 21 mm/s
Protection class: IP65 in accordance with EN 60529 with
cable plug
Media: neutral gaseous and liquid media, which do not attack
body and sealing materials (see table of resistance under
www.burkert.com)
Check resistance in individual cases
4.4 Fluidic data
Operating principle
A
(NC)
2/2-way valve, normally closed
B
(NO)
2/2-way valve, normally open
Pressure range: see type label
Line connectors: Type 6013: G1/8, G1/4, G3/8, Flange
Type 6013A: G1/8, G1/4
Note the information specified on the type label for voltage, type
of current, and pressure.
english
6
4.5 Type label (example)
Ident. no.
Voltage, Frequency, Output
if applicable
Nominal connection pressure
Type
Circuit function
Orifice
Sealing material
Body material
6013 A 2,0 FKM MS
Made in Germany
WXXXX
24V 50Hz 7W
G1/8 PN 0
-
10 bar
4.6 Electrical data
Connections: DIN EN 175301-803 Form A
for cable plug Type 2508
Supply voltage: Type 6013: 24 V DC ± 10 %
max. residual ripple 10 %
24 V / 50 Hz
230 V / 50 Hz
Type 6013A: 24 V DC ± 10 %
max. residual ripple 10 %
230 V / 50 Hz
Voltage tolerance: ± 10 %
Nominal output: CFA: 8 W (5 W, 10 W)
CFB AC: 7 W (9 W)
DC: 8 W
Impulse version DC: 7 W
Nominal operating mode: 100 % continuous operation
for block installation:
5 W continuous operation
on request a. A.
8 W intermittent operation 60 %
(30 min)
english
Type 6013

7
5 INSTALLATION
5.1 Safety instructions
DANGER!
Risk of injury from high pressure in the equipment!
▶ Before loosening the lines and valves, turn off the pressure and
vent the lines.
Risk of injury due to electrical shock!
▶ Before reaching into the system, switch off the power supply and
secure to prevent reactivation!
▶ Observe applicable accident prevention and safety regulations for
electrical equipment!
WARNING!
Risk of injury from improper installation!
▶ Installation may be carried out by authorized technicians only and
with the appropriate tools!
Risk of injury from unintentional activation of the system and an
uncontrolled restart!
▶ Secure system from unintentional activation.
▶ Following installation, ensure a controlled restart.
5.2 Fluid installation
Installation position: any, actuator preferably upwards.
Procedure:
→ Clean any possible dirt off the pipelines and flange connections.
→ Install a dirt trap to prevent malfunctions (0.2 ... 0.4 mm).
Pay attention to the flow direction of the valve: from 1 (P) →
2(A) (CFA) or from 1(P) → 2(B) (CFB).
Valve with threaded connection:
→ Use PTFE tape as sealing material.
NOTE!
Caution risk of breakage!
• Do not use the coil as a lifting arm.
→ Hold the device with a Open-end wrench on the body and screw
into the pipeline.
Valve with flanged connection:
→ Remove the cover plate.
→ Loosen the nut on the coil and remove coil.
english
8
WARNING!
Danger – escaping medium!
Leaking connections if seals not seated properly, if manifold uneven or if
surface quality of the manifold inadequate.
▶ Make certain the seals included with delivery are properly seated in
the valve.
▶ Ensure that the manifold is even.
▶ Ensure that the surface quality of the manifold is adequate.
→ Insert the seal into the body.
→ Screw the body onto the manifold (max. 1.5 Nm).
→ Attach the coil and screw on the nut (max. 5 Nm).
seal
nut
coil
cover plate
manifold
5.3 Electric installation
WARNING
Risk of injury due to electrical shock!
▶ Before reaching into the system, switch off the power supply and
secure to prevent reactivation!
▶ Observe applicable accident prevention and safety regulations for
electrical equipment!
If the protective conductor contact between the coil and body is
missing, there is danger of electrical shock!
▶ Always connect protective conductor.
▶ Check electrical continuity between coil and body.
Note the voltage and current type as specified on the type label.
Procedure:
→ Check that the seal is correctly seated.
→ Screw cable plug tightly onto coil (max. 1 Nm).
english
9
Control of pulse version
Correct polarity is essential to ensure that the device functions: Note identification on the upper side of the coil.
Pulse duration at least 50 ms.
switch ON +
Terminal 1
Terminal 2
Protective conductor connection
Polarity Specifications Terminal connections
- Switch ON +
Valve (P seat)
will be opened
(+) on terminal 2,
(–) on terminal 1
+ Switch OFF -
Valve (P seat)
will be closed
(+) on terminal 1,
(–) on terminal 2
Use only cable plug without electrical wiring for pulse versions.
5.4 Rotation of coil
WARNING!
Electric shock!
If the protective conductor contact between the coil and body is
missing, there is danger of electrical shock!
▶ Check protective conductor contact after installing the coil.
Overheating, Risk of fire!
Connection of the coil without pre-assembled valve will result in
overheating and destroy the coil.
▶ Connect the coil with assembled valve only.
Nut
max. 5 Nm
O-ring
Fitting
The coil can be turned by 4 x 90° (for
block installation only 2 x 180°).
Procedure:
→ Loosen nut.
→ Turn coil.
→ Tighten nut with a open-end wrench
(max. 5 Nm).
english
Type 6013

10
6 MAINTENANCE,
TROUBLESHOOTING
6.1 Safety instructions
WARNING!
Risk of injury from improper maintenance!
▶ Maintenance may be carried out by authorized technicians only and
with the appropriate tools!
Risk of injury from unintentional activation of the system and an
uncontrolled restart!
▶ Secure system from unintentional activation.
▶ Following maintenance, ensure a controlled restart.
6.2 Malfunctions
If malfunctions occur, check:
• the line connectors,
• the operating pressure,
• the power supply and valve control.
If the valve still does not switch, please contact your Bürkert Service.
7 DISASSEMBLY
7.1 Safety instructions
DANGER!
Risk of injury from high pressure in the equipment!
▶ Before loosening the lines and valves, turn off the pressure and vent
the lines.
Risk of injury due to electrical shock!
▶ Before reaching into the system, switch off the power supply and
secure to prevent reactivation!
▶ Observe applicable accident prevention and safety regulations for
electrical equipment!
WARNING!
Risk of injury from improper disassembly!
▶ Disassembly may be carried out by authorized technicians only and
with the appropriate tools!
english
11
7.2 Disassembly
→ Turn off the pressure and vent the lines.
→ Switch off the power supply.
→ Loosen the cable plug.
Valve with threaded connection:
→ Hold the device with the open-end wrench on the body and
screw off the pipeline.
Valve with flanged connection:
→ Loosen the nut on the coil and remove coil.
→ Loosen the body from the manifold.
8 SPARE PARTS
CAUTION!
Risk of injury and/or damage by the use of incorrect parts!
Incorrect accessories and unsuitable spare parts may cause injuries
and damage the device and the surrounding area.
▶ Use only original accessories and original spare parts from
Bürkert.
• Coil and fitting can be ordered complete by quoting the identification number of the device.
• Wearing part set on request.
english
12
9 TRANSPORT, STORAGE, DISPOSAL
NOTE!
Transport damages!
Inadequately protected equipment may be damaged during
transport.
• During transportation protect the device against wet and dirt in
shock-resistant packaging.
• Avoid exceeding or dropping below the allowable storage
temperature.
Incorrect storage may damage the device.
• Store the device in a dry and dust-free location!
• Storage temperature: -40 - 80 °C.
Damage to the environment caused by device components
contaminated with media.
• Observe applicable regulations on disposal and the environment.
english
Type 6013