BYTES BR605, BR610, BR61, BR66, BR64 Datasheet

...
BR605 BR610THRU
SINGLE PHASE 6.0 AMP BRIDGE RECTIFIERS
FEATURES
* Low forward voltage
* Low leakage current
* Mounting: Hole thru for #6 screw
* Mounting position: Any
VOLTAGE RANGE
50 to 1000 Volts
CURRENT
6.0 Amperes
BR-6
.042(1.1) DIA. .039(1.0) TYP.
.620(15.7)
HOLE FOR NO. 6 SCREW
.580(14.7)
AC
AC
+
.270(6.8) .230(5.8)
.750
MIN.
(19.1)
.445(11.3) .405(10.3)
.620(15.7) .580(14.7)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating 25 C ambient temperature uniess otherwies specified. Single phase half wave, 60Hz, resistive or inductive load. For capacitive load, derate current by 20%.
TYPE NUMBER
Maximum Recurrent Peak Reverse Voltage Maximum RMS Voltage Maximum DC Blocking Voltage Maximum Average Forward Rectified Current
.375"(9.5mm) Lead Length at Tc=75 C Peak Forward Surge Current, 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Maximum Forward Voltage Drop per Bridge Element at 3.0A D.C. Maximum DC Reverse Current Ta=25 C
at Rated DC Blocking Voltage Ta=100 C Operating Temperature Range, TJ Storage Temperature Range, TSTG
BR605 BR61 BR62 BR64 BR66 BR68 BR610 UNITS
50 100 200 400 600 800 1000 V 35 70 140 280 420 560 700 50 100 200 400 600 800 1000 V
6.0
125
1.0
10
200
-65 +125
-65 +150
V
A
A V
µA
µA
C C
162
RATING AND CHARACTERISTIC CURVES (BR605 THRU BR610)
FIG.1-TYPICAL FORWARD CURRENT
DERATING CURVE
6
5
4
Single Phase
3
Half Wave 60Hz
Resistive Or Inductive Load
2
1
AVERAGE FORWARD CURRENT,(A)
0
0 25 50 75 100 125 150 175
CASE TEMPERATURE,( C)
FIG.3-TYPICAL FORWARD
CHARACTERISTICS
FIG.2-MAXIMUM NON-REPETITIVE FORWARD
125
100
75
50
25
PEAK FORWARD SURGE CURRENT,(A)
0
1 10 5
SURGE CURRENT
Tj=25 C
NUMBER OF CYCLES AT 60Hz
FIG.4-TYPICAL REVERSE
CHARACTERISTICS
8.3ms Single Half
Sine Wave
JEDEC method
50
100
50
10
3.0
1.0
Pulse Width 300us 1% Duty Cycle
0.1
INSTANTANEOUS FORWARD CURRENT,(A)
.01
0 .2 .4 .6 .8 1.0 1.2 1.4
FORWARD VOLTAGE,(V)
Tj=25 C
50
10
3.0
1.0
0.1
REVERSE LEAKAGE CURRENT, ( A)µ
Tj=25 C
.01
0
20 40 60 80 100 120 140
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
163