BYTES 10A8, 10A6, 10A4, 10A10, 10A1 Datasheet

...
10A005 10A10THRU
10.0 AMP SILICON RECTIFIERS
FEATURES
VOLTAGE RANGE
50 TO 1000 Volts
CURRENT
10.0 Amperes
* Low forward voltage drop * High current capability * High reliability * High surge current capability
.360(9.1) .340(8.6)
DIA.
R-6
MECHANICAL DATA
* Case: Molded plastic * Epoxy: UL 94V-0 rate flame retardant * Lead: Axial leads, solderable per MIL-STD-202,
method 208 guranteed
* Polarity: Color band denotes cathode end * Mounting position: Any *
Weight: 1.65 grams
.052(1.3) .048(1.2)
DIA.
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating 25 C ambient temperature uniess otherwies specified. Single phase half wave, 60Hz, resistive or inductive load. For capacitive load, derate current by 20%.
TYPE NUMBER
Maximum Recurrent Peak Reverse Voltage Maximum RMS Voltage Maximum DC Blocking Voltage Maximum Average Forward Rectified Current
.375"(9.5mm) Lead Length at Ta=60 C Peak Forward Surge Current, 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Maximum Instantaneous Forward Voltage at 10.0A Maximum DC Reverse Current Ta=25 C
at Rated DC Blocking Voltage Ta=100 C Typical Junction Capacitance (Note 1)
Typical Thermal Resistance R JA (Note 2)θ 10
Operating and Storage Temperature Range T , TJ STG
10A05 10A1 10A2 10A4 10A6 10A8 10A10 UNITS
50 100 200 400 600 800 1000 V 35 70 140 280 420 560 700 50 100 200 400 600 800 1000 V
10.0
400
1.0
10.0
400
100
-65 +150
1.0(25.4) MIN.
.360(9.1) .340(8.6)
1.0(25.4) MIN.
V
A
A V
µA
µA
pF
C/W
C
NOTES:
1. Measured at 1MHz and applied reverse voltage of 4.0V D.C.
2. Thermal Resistance from Junction to Ambient .375" (9.5mm) lead length.
128
RATING AND CHARACTERISTIC CURVES (10A005 THRU 10A10)
FIG.1-TYPICAL FORWARD
CHARACTERISTICS
FIG.2-TYPICAL FORWARD CURRENT DERATING CURVE
500
100
40
10
Pulse Width 300us 1% Duty Cycle
1
INSTANTANEOUS FORWARD CURRENT,(A)
.6 .8 1.0 1.2 1.4 1.6 1.8 2.0
FORWARD VOLTAGE,(V)
FIG.3 - TYPICAL REVERSE
CHARACTERISTICS
100
Tj=25 C
12
10
8
6
4
2
AVERAGE FORWARD CURRENT,(A)
0
Single Phase
Half Wave 60Hz
Resistive Or Inductive Load
0.375"(9.5mm) Lead Length
0 20 40 60 80 100 120 140 160 180 200
AMBIENT TEMPERATURE,( C)
FIG.4-MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
500
400
300
8.3ms Single Half
Sine Wave
JEDEC method
200
100
PEAK FORWARD SURGE CURRENT,(A)
0
1 10 5
Tj=25 C
NUMBER OF CYCLES AT 60Hz
50
100
10
Tj=100 C
1.0
.1
REVERSE LEAKAGE CURRENT, ( A) µ
.01
0 20 40 60 80 100 120 140
PERCENT OF RATED PEAK REVERSE VOLTAGE,(%)
Tj=25 C
FIG.5 - TYPICAL THERMAL RESISTANCE VS. LEAD LENGTH
25
20
15
10
5
THERMAL RESISTANCE, ( C/W)
0 .1 .2 .3 .4 .5 .6 .7 .8 .9 1.0
EQUAL LEAD LENGTH TO HEAT SINK, INCHES