Caution: always make sure the switch converter is secure in the back box when programming.
Switch Converter
Up to Six remote control units can be paired with each converter switch or module. To pair a converter switch, connect the converter unit as per the wiring instructions. Using a small screw driver press "Learn" button. The LED will start to flash; press the selected "ON" button on the remote control, the LED will stop flashing. The units are now paired together, you can test this by pressing the selected "On/Off" button.
Deleting Remote Control:
To delete a remote control that has been paired with a HomeEasy receiver unit, press the "Learn". The LED will start to blink; press the "Off" button on the remote control, the LED will blink twice to confirm that the remote control has been removed from the receiver sockets memory.
Pairing/Deleting with Remote Control:
RE-INVENTING THE HOME
HOME
easy
HE-203 Remote Control
Switch Converter & Dimmer
V1.0
Installation:
The HomeEasy remote control Switch Converter allows you to convert a standard 1way light switch in to a HomeEasy remote control unit. For use with in series with incandescent lighting only.
INSTALLATION WARNINGS:
BEFORE COMMENCING INSTALLATION
ISOLATE YOUR MAINS ELECTRIC SUPPLY
Read the instructions care fully before starting the installation process and keep them for future reference. If you are in any doubt on the installation process, consult a qualified electrician.
This product should be installed in accordance with the relevant sections of the building regulations code, and the current edition of the IEE Wiring Regulations (BS 7671:Requirements for electrical installations) and appropriate statutory regulations.
As of1 April 2004, new installations in the UK should be wired using the EU harmonised colours for the supply conductors: New colours:  BROWN = Live  BLUE = Neutral Earth = Yellow/Green Old colours:  RED = Live BLACK = Neutral The old colours will cease from April 2006.
Electrical installations in bathrooms, kitchens, gardens, floor and heating systems, swimming pools, saunas and extra-low voltage lighting are classed as special installations and must
Do not install ceiling receivers on lighting circuits used to supply other products such as extractor fans and shaver socket outlets. Do not exceed the Maximum Power Rating of 210W, Incandescent lighting only
Origional Switch
240V ~50Hz
Do not use the switch converter with low voltage lighting transformers, fluorescent bulbs, and energy saving lighting or fans, incorrect installation may damage the converter. In case of any doubt consult a qualified electrician.
1: Isolate the mains supply, then remove the existing switch and disconnect the wiring from the switch terminals on the back of the light switch.
2: Ensure the wall box is free from plaster lumps, projecting screw heads or any other material. The switch converter is designed to fit in a 25mm back box, if required a deeper back box or a proprietary spacer can be used between the switch and the wall.
3: Wire the mains cable to the converter switch as per the diagram below:
240V Input
L
4: Connect the two switching wires from the switch converter to the original light switch, making sure 1 way operation is used.
5: Make sure all terminals and earth connections are correct and secure with no bare wires showing. You will now need to program the switch converter:-
L
Making sure the live cable is connected to " " terminal and, the switch live wire to the " " terminal.
6: Gently replace the switch cover making sure no wires are caught between the switch and the wall. Do not over tighten as this could crack or distort the switch. Reconnect the mains supply
Learn Button
C H Byron 34, Sherwood Rd Aston Fields Bromsgrove B60 3DR
Contact Details :
433MHz
R&TTE
APPROVED
CH Byron Electrical United Kingdom. www.chbyron.com
A
B DK FIN
F
D GR
LT
IRL
I L
NL
P E S
UK BG CZ EST
H IS
LV
M N
SK SLO CH PL RO
0560
Tel: 0845 2301231 Fax: 01527 557701 Web: www.chbyron.com E-mail: support@chbyron.com
Help: Occasionally interference from receiver sockets plugged into adjacent wall sockets or when used with transformers (low voltage products) can affect the operating range. Try placing one of the receiver sockets in another wall socket. For low voltage products place the transformer as far away form the receiver socket as possible.
Contact:   Helpline: 0845 2301 231
TIMBER
CONCRETE
METAL
GLASS
PLASTICS
RF Range: : The radio signals operating distance is reduced when the signal has
to pass through walls. The radio signals achieve a range of 30m inside a building; this can be reduced depending on the type of material
10 - 15%
BRICK
10 - 40%
40- 80%
10 - 40%
90%
5 - 15%
Range
Reduction Guide:
Switching On/Off /Dimming:
Help Section :
Product Specification:
Switch Converter: HE-203 Power: 230V ~50Hz Max Load 210W (Incandescent Lighting) Internal Fuse: 2A, 130 degrees Celsius Range: 30 Metres (Open Distance) Frequency: 433.92MHz Indoor Use Only
Warning: Never Exceed the Product Specification
OFF
ON
Remote Control: On: Press on button OFF: Press Off button
(See pairing/deleting with remote control)
1
2
Remote Socket reset:
To delete all the remote control units from the memory of the receiver socket, hold the "Learn" button for more than 6 seconds, the LED will start to blink continuously. Press the learn button again, the LED will blink twice to confirm the deletion of all remote controls form the receiver memory.
Dimming: Press "On" and then press "On" again, the converter unit will now start to dim, press "On" to select the required level. To switch "Off", press off as normal.
Standard Light Switch: On/Off: Switch on and off as normal. Dimming: Switch On, Off and On again. The converter will now start to dim, to
select the required level switch the light Off and On.