BY202
4:
1:
2:
1: Push Button 5: Plug-in Chime
2: Melody Selector 6: Speaker
3: Bell Push Battery 7: Volume control
4: Signal Sent LED
1
2
™
Plug-in
Wire Free Chime Kit
5:
6:
7:
:3
1: Place a small flat screwdriver
into the locking clip on the
base of the Bell Push.
2: Gently twist.
3: The backing plate will unclip.
1: Insert CR2032 battery
(Supplied) into the battery
holder.
2: Make sure the positive side
is facing upwards.
3: Replace back plate.
Warning: Make sure that the batteries are
replaced correctly to avoid battery failure.
Only replace with same or equivalent type.
4
4
Beep
Beep
1: Press and hold the ‘VOL’
button on the Door Chime,
until the Chime goes
‘Beep Beep’ (6 Seconds).
2: Press the Bell Push within
60 seconds to learn the
Bell Push to the chime.
3: The Chime will ring to
confirm setup.
Note: Maximum of 6 Bell
Pushes can be learnt to a
single Chime.
Functions:
To select a melody for the Door Chime
1: Remove the Back Plate from the Bell
Push.
2: Press the Melody Select button.
CR2032
6 Selectable Melodies
1: Tubular 3-Note 4: Solo
2: Big Ben 5: Tubular Score
3: Tubular 2-Note 6: Clarinet
To select the Chime Volume level, press the ‘VOL’
button on the chime There are 4 selectable volume
levels, the Door Chime is pre-set to the loudest
volume setting.
3:The chime will play the newly selected
sound.
4: Press again to select the next melody.
Note: For Front/Back door setup, select a
different melody in one of the Bell Pushes.
Adding Additional Chime/Bell Push:
New Chime
Additional Chime
To add an additional Chime unit to the Door Chime kit
1: Press and hold the ‘VOL’ button on your New Door Chime, until the
Chime goes ‘Beep Beep’ (6 Seconds)
2: Press the Bell Push within 60 seconds to learn the additional
Chime to the Bell Push.
3: Chime will ring to confirm setup, wait 60 seconds for the Chime to
exit the learn mode before repressing the bell push.
Additional Bell Push
To add an additional Bell Push to the Door
Chime kit.
1: Press and hold the ‘VOL’ button on your
Door Chime, until the Chime goes
‘Beep Beep’ (6 Seconds).
2: Press the Bell Push within 60 seconds
to learn the additional Bell Push to the
Chime.
3: Chime will ring to confirm setup, wait 60 seconds for the Chime
to exit the learn mode before repressing the bell push.
For Front/back door setup, select a different melody in one of
the Bell Pushes - See Melody Selection.
Note: Maximum of 6 Bell Pushes can be learnt to a single Chime
Beep
Beep
Front Door
Back Door
3
1: plug Chime into a UK 3pin
socket, 220 – 240V ~ 50Hz.
2: Switch the socket on.
3: Chime will ‘Beep’ on Start up.
Default
Volume
Installation Guide:
1
performance
Note: Try adjusting the location of the Bell Push to the Left/Right or
place on external wall.
Avoid locating the Bell Push/Chime on or directly near
metallic surfaces as this may reduce the operation
range.
UPVC Door Frames:
When locating the bell push onto a UPVC door, always
check the operating performance before final
installation, internal metal frame may affect
.
Installation Guide: Bell Push
2
‘CLICK’
1: Using back plate as a
template
2: Making sure UP arrows
points UP.
2: Mark and drill holes.
3: Insert wall plugs and attach
to wall using screws
provided.
4: Clip the Bell Push on to the
back plate making sure the
Bell Push ‘Clicks’ in to
place.
Note: The Bell Push can be
installed using a suitable
double sided adhesive tab or
tape when drilling is not
sutiable.
Installation Guide: Chime
Place the door Chime within the operating range, transmis-
3
sion of the wire free signal through
Walls, Doors and Ceilings etc, may reduce the operating
range. Chime unit for INDOOR use only.
Changing Batteries:
Bell Push:
1: Remove back plate from the
Bell Push.
2: Remove old battery from the
holder.
3: Replace with new ‘CR2032’ 3V
battery.
4: Insert into holder making sure
‘+’ is facing up.
5: Test Chime Kit.
Always dispose of old batteries in an environmentally friendly way.
Type R2 Device - device where the sound output is created by the initial operation
Range Guide
Range Guide
Type R2 Device - device where the sound output is created by the initial operation
of the control and where the period of sound output continues for the
of the control and where the period of sound output continues for the
designed duration irrespective of condition of the control.
designed duration irrespective of condition of the control.
Specification
Specification
Bell Push: BYT
Bell Push: BYT
Power: 1 x CR2032 3V DC Battery
Power: 1 x CR2032 3V DC Battery
(Included)
(Included)
IP44 Weather Resistant
IP44 Weather Resistant
Resetting Chime:
Vol
Beep
Beep
Beep
Beep
Reset Chime unit to factory settings.
1: Press and hold the ‘VOL’ button on your Door Chime,
until the Chime goes ‘Beep Beep’ (6 Seconds)
2: Release the ‘VOL’ button
3: Re-press and hold the ‘VOL’ button on your Door Chime,
until the Chime goes ‘Beep’ (6 Seconds)
4: The Chime is now reset.
User Hints:
In case of the door chime does not sound, please check the
followings:
a) Flat batteries in either Push Button or Door Chime.
b) Wrong battery polarity in either Push Button or Door Chime.
c) For Plug-in Door Chimes make sure the socket is switched on.
d) Bell Push and Door Chime are not paired together, see setup
guide.
e) Materials in between the Bell Push & Chime will reduce the
operating range, move the Door Chime closer to the Bell Push
f) Wire free devices can be affected by external sources e.g. wire
free home alarms or power transformers/adapter
IMPORTANT: There are no serviceable parts, do not repair.
IMPORTANT: There are no serviceable parts, do not repair.
Plug-in Door Chime: BY202
Power: 220 - 240V 50Hz
Range: 100 Metres
Indoor Use Only
Vol
Beep
Diagram for illustration purposes only
Tel: 0845 2301231 (UK)
9-5 Mon-Fri, Local call charges apply
support@chbyron.com
www.chbyron.com
GB: CH Byron
Byron House, Sherwood Rd
Astonfields, Bromsgrove
B60 3DR
UK
433.92MHz
433.92MHz
R&TTE
R&TTE
APPROVED
APPROVED
IRL
IRL
A
A
B
B
DK
DK
NL
NL
FIN
FIN
F
F
D
D
GR
GR
LT
LT
CH Byron Electrical United Kingdom. www.chbyron.com
CH Byron Electrical United Kingdom. www.chbyron.com
V1.0
V1.0
I
I
L
L
P
P
E
E
S
S
Project Manager
Project Manager
Mr G Hunter
Mr G Hunter
UK
UK
BG
BG
CZ
CZ
EST
EST
H
H
IS
IS
LV
LV
SK
SK
SLO
SLO
CH
CH
PL
PL
RO
RO
M
M
N
N