BW Technologies LP (BW) warrants this product to be free from defects in material and workmanship under normal use and service for a
period of two years, beginning on the date of shipment to the buyer. This warranty extends only to the sale of new and unused products to
the original buyer. BW’s warranty obligation is limited, at BW’s option, to refund of the purchase price, repair, or replacement of a defective
product that is returned to a BW authorized service center within the warranty period. In no event shall BW’s liability hereunder exceed the
purchase price actually paid by the buyer for the Product. This warranty does not include:
a) fuses, disposable batteries or the routine replacement of parts due to the normal wear and tear of the product arising from
use;
b) any product which in BW’s opinion, has been misused, altered, neglected or damaged by accident or abnormal conditions of
operation, handling or use;
c) any damage or defects attributable to repair of the product by any person other than an authorized dealer, or the installation
The obligations set forth in this warranty are conditional on:
THE BUYER AGREES THAT THIS WARRANTY IS THE BUYER’S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE. BW SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR
CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, WHETHER ARISING FROM BREACH OF WARRANTY OR
BASED ON CONTRACT, TORT OR RELIANCE OR ANY OTHER THEORY.
Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or
consequential damages, the limitations and exclusions of this warranty may not apply to every buyer. If any provision of this warranty is
held invalid or unenforceable by a court of competent jurisdiction, such holding will not affect the validity or enforceability of any other
provision.
of unapproved parts on the product; or
a) proper storage, installation, calibration, use, maintenance and compliance with the product manual instructions and any other
applicable recommendations of BW;
b) the buyer promptly notifying BW of any defect and, if required, promptly making the product available for correction. No
goods shall be returned to BW until receipt by the buyer of shipping instructions from BW; and
c) the right of BW to require that the buyer provide proof of purchase such as th e original invoice, bill of sale or packing slip to
establish that the product is within the warranty period.
Limited Warranty & Limitation of Liability
Contacting BW Technologies by Honeywell
USA: 1-888-749-8878 Canada: 1-800-663-4164
Europe: +44 (0) 1295 700300 Other countries: +1-403-248-9226
Email us at:
Visit BW Technologies by Honeywell’s web site at: www.gasmonitors.com
info@bwtnet.com

GasAlertMicroClip
Introduction
This quick reference guide provides basic information for the
GasAlertMicroClip. Refer to the user manual on the
accompanying CD-ROM for complete operating instructions.
The GasAlertMicroClip gas detector (“the detector”) warns of
hazardous gas at levels above user-selectable alarm setpoints.
The detector is a personal safety device. It is your responsibility
to respond properly to the alarm.
Note
The detector is shipped with English as the default displayed
language. Additional languages provided are Portuguese,
Spanish, German, and French. The screens for the additional
languages are displayed on the detector and in the
corresponding Quick Reference Guide.
Safety Information - Read First
Use the detector only as specified in this guide, otherwise
the protection provided by the detector may be impaired.
Read the following Cautions before using the detector.
a Cautions
⇒ Warning: Substitution of components may impair
Intrinsic Safety.
⇒ Caution: For safety reasons, this equipment
must be operated and serviced by qualified
personnel only. Read and understand the user
manual completely before operating or servicing.
⇒ Charge the detector before first-time use. BW
recommends the detector be charged after every
workday.
⇒ Calibrate the detector before first-time use and
then on a regular schedule, depending on use
and sensor exposure to poisons and
contaminants. BW recommends at least once
1

GasAlertMicroClip
Quick Reference Guide
every 180 days (6 months).
⇒ The combustible sensor is factory calibrated to
50% LEL methane. If monitoring a different
combustible gas in the % LEL range, calibrate
the sensor using the appropriate gas.
⇒ Only the combustible gas detection portion of
this instrument has been assessed for
performance by CSA International.
⇒ Calibrate only in a safe area that is free of
hazardous gas.
⇒ It is recommended that the combustible sensor
be checked with a known concentration of
calibration gas after any known exposure to
contaminants/poisons (sulfur compounds,
silicon vapors, halogenated compounds, etc.).
⇒ BW recommends to “bump test” the sensors,
before each day’s use, to confirm their ability to
respond to gas by exposing the detector to a gas
concentration that exceeds the alarm setpoints.
Manually verify that the audible and visual
alarms are activated. Calibrate if the readings are
not within the specified limits.
⇒ Caution: High off-scale readings may indicate an
explosive concentration.
⇒ Any rapid up-scaling reading followed by a
declining or erratic reading may indicate a gas
concentration beyond upper scale limit, which
2
may be hazardous.
⇒ Extended exposure of the GasAlertMicroClip to
certain concentrations of combustible gases and
air may stress a detector element, which can
seriously affect its performance. If an alarm
occurs due to high concentration of combustible
gases, recalibration should be performed, or if
needed, the sensor replaced.
⇒ Protect the combustible sensor from exposure to
lead compounds, silicones, and chlorinated
hydrocarbons. Although certain organic vapors
(such as leaded gasoline and halogenated
hydrocarbons) may temporarily inhibit sensor
performance, in most cases, the sensor will
recover after calibration.
⇒ For use only in potentially explosive
atmospheres where oxygen concentrations do
not exceed 20.9% (v/v).

Parts of the GasAlertMicroClip
GasAlertMicroClip
Parts of the GasAlertMicroClip
Item Description
1 Visual alarm bars (LED)
2 Liquid crystal display (LCD)
3 Audible alarm
4 Sensors
5 Pushbutton
6 Charging connector / IR interface
7 Alligator clip
3

GasAlertMicroClip
Quick Reference Guide
Display Elements
4
Item Description
1
2 Automatically span sensor
3 Gas cylinder
4 Gas identifier bars
5 Battery life indicator
6 Stealth mode
7 Numeric value
8 Automatically zero sensor
Alarm condition