Series
multi-gas detectors
VOCs
Protect yourself
Simultaneously monitor and display up to fi ve atmospheric
hazards with the GasAlertMicro 5 Series. Adaptable to a
variety of applications, the GasAlertMicro 5 Series has an
extensive selection of user-settable fi eld options and is
available as either a standard toxic gas model, a PID model
for the detection VOCs, or an IR model for CO
Use the passcode function to prevent unauthorized
modifi cations of the instrument’s settings. Compatible with
BW’s MicroDock II automatic test and calibration system,
the GasAlertMicro 5 Series is unparalleled in its versatility,
performance and overall value.
detection.
2
CO
LEL
H
2
CO
O
SO
PH
NH
NO2
HCN
2
S
2
2
3
3
Generation 2 pump
with visible integrated fi lter
• Measure up to fi ve atmospheric hazards concurrently
• Fully customizable to suit any application
• Rapidly switch from diffusion mode to the optional
integrated pump in the fi eld
Wear yellow. Work safe.
Cl
ClO
2
2
O
3

Quickly switch from
diffusion to integral
pump option
Sensor for fi fth toxic, PID,
or CO2 hazards
Four bright, wide-angled
alarm bars
Integral concussion-proof
enclosure
95 dB audible alarm
(typical)
Raised buttons, easy to
use with gloves
Large, easy-to-read
display
Optional datalogging
stores several months of
continuous data
Replaceable integrated fi lter
•
window enables user to
visually inspect fi lter
•
provides superior dust
and water resistance
Multiple charging
options available
Internal vibrating alarm for
high-noise areas
Stainless steel
alligator clip
AA alkaline or hot-swappable
rechargeable battery pack
options allow for battery
installation in the fi eld
Instrument model differences
GasAlertMicro 5 GasAlertMicro 5 PID GasAlertMicro 5 IR
Gases Detected
Sensors
Typical battery life
AA Alkaline
Rechargeable
1
Based on the run time of a 5-gas instrument in diffusion mode at +68°F/+20°C, other instrument confi gurations or environmental conditions may increase/decrease the battery life of your instrument.
H2S, CO, O2, SO2, PH3, NH3, NO2, HCN,
Cl2, ClO2, O3 and combustibles (LEL)
Plug-in, electrochemical cell (toxic and oxygen);
catalytic (LEL)
1
20 hours
20 hours
VOCs (PID), H2S, CO, O2, SO2, PH3, NH3, NO2,
HCN, Cl2, ClO2, O3 and combustibles (LEL)
Plug-in, electrochemical cell (toxic and oxygen);
catalytic (LEL); Photoionization detector (PID) with
10.6 eV lamp for volatile organic compounds (VOCs)
15 hours
15 hours
CO2 (IR), H2S, CO, O2, SO2, NH3, O3 and
combustibles (LEL)
Plug-in, electrochemical cell (toxic and oxygen);
catalytic (LEL); infrared (IR) for carbon dioxide
(CO2)
15 hours
15 hours