Series
multi-gas detectors
VOCs
Protect yourself
Simultaneously monitor and display up to fi ve atmospheric
hazards with the GasAlertMicro 5 Series. Adaptable to a
variety of applications, the GasAlertMicro 5 Series has an
extensive selection of user-settable fi eld options and is
available as either a standard toxic gas model, a PID model
for the detection VOCs, or an IR model for CO
Use the passcode function to prevent unauthorized
modifi cations of the instrument’s settings. Compatible with
BW’s MicroDock II automatic test and calibration system,
the GasAlertMicro 5 Series is unparalleled in its versatility,
performance and overall value.
detection.
CO
LEL
H
CO
O
SO
PH
NH
NO2
HCN
S
Generation 2 pump with visible integrated fi lter
Measure up to fi ve atmospheric hazards concurrently
Fully customizable to suit any application
Rapidly switch from diffusion mode to the optional
integrated pump in the fi eld
Wear yellow. Work safe.
Cl
ClO
O
Quickly switch from diffusion to integral pump option
Sensor for fi fth toxic, PID, or CO2 hazards
Four bright, wide-angled alarm bars
Integral concussion-proof enclosure
95 dB audible alarm (typical)
Raised buttons, easy to use with gloves
Large, easy-to-read display
Optional datalogging stores several months of continuous data
Replaceable integrated fi lter
window enables user to
visually inspect fi lter
provides superior dust
and water resistance
Multiple charging options available
Internal vibrating alarm for
high-noise areas
Stainless steel alligator clip
AA alkaline or hot-swappable rechargeable battery pack options allow for battery installation in the fi eld
Instrument model differences
GasAlertMicro 5 GasAlertMicro 5 PID GasAlertMicro 5 IR
Gases Detected
Sensors
Typical battery life
AA Alkaline
Rechargeable
1
Based on the run time of a 5-gas instrument in diffusion mode at +68°F/+20°C, other instrument confi gurations or environmental conditions may increase/decrease the battery life of your instrument.
H2S, CO, O2, SO2, PH3, NH3, NO2, HCN, Cl2, ClO2, O3 and combustibles (LEL)
Plug-in, electrochemical cell (toxic and oxygen); catalytic (LEL)
1
20 hours 20 hours
VOCs (PID), H2S, CO, O2, SO2, PH3, NH3, NO2, HCN, Cl2, ClO2, O3 and combustibles (LEL)
Plug-in, electrochemical cell (toxic and oxygen); catalytic (LEL); Photoionization detector (PID) with
10.6 eV lamp for volatile organic compounds (VOCs)
15 hours 15 hours
CO2 (IR), H2S, CO, O2, SO2, NH3, O3 and combustibles (LEL)
Plug-in, electrochemical cell (toxic and oxygen); catalytic (LEL); infrared (IR) for carbon dioxide (CO2)
15 hours 15 hours
Sensors
The GasAlertMicro 5 is available in three models: toxic/ electrochemical, PID (for VOCs) or IR (for CO
). For more
information about available sensor confi gurations, please contact BW Technologies by Honeywell.
Electrochemical and catalytic bead sensors available for:
S CO O
H
SO2 Cl2 ClO2 NH3 PH3 HCN NO2 O3 Combustibles (LEL)
Photoionization sensor available for volatile organic compounds (VOCs) detection.
Infrared (IR) gold series sensors available for carbon dioxide (CO
) detection.
Note: Due to board and sensor confi guration GasAlertMicro 5 models are not interchangeable (i.e. a PID sensor cannot be used in a IR confi gured unit).
Industrial Applications
GasAlertMicro 5
Industry or Application Sources of Additional Hazards
Confi ned Space Entry
Wastewater Plants
Steel / Iron Production
Pulp and Paper
Food and Beverage
Construction
GasAlertMicro 5 PID
Industry or Application Sources of VOC Hazards
Confi ned Space Entry
Hazmat / Homeland Security
Industrial Hygiene and Confi ned Space
Airlines (wing-tank entry)
Landfi lls
Oil and Gas
Chemical Plants
GasAlertMicro 5 IR
Industry or Application Sources of CO
Confi ned Space Entry
Wineries and Breweries
Agriculture
Marine Fuel Transport / Shipping and Shipyards
Oil Well Fracturing
Wastewater Treatment
Food Industry / Cold Storage
Industrial and Chemical Manufacturing
Landfi lls
Various sources - industrial chemicals
Cl2, NH3, ClO2 from treatment
NO
2
Cl2 from bleaching
NH3 from refrigerants, ice production PH
from fumigation
3
Confi ned space entry, trenching, and NO2 from diesel exhaust
Respiration and aerobic bacterial decomposition
Detect fl ammables not detected by LEL sensor (diesel, gasoline vapor, turpentine, etc)
Wide number of potential hazards (benzene, diesel, ethanol, toluene, etc.) dependant on industry
Jet fuel not detectable by LEL sensor, PID required
Decomposing organic matter, emission of chemical compounds
By-products of refi ning processes
Number of potential hazards dependant on product and process of manufacturing
Hazards
2
Respiration and aerobic bacterial decomposition
By-product of yeast fermentation
Greenhouses, mushroom farms use CO2 to enhance growth; also used to speed ripening of fruits and vegetables, aerobic bacteria in manure pits
Used for fi re suppression and inerting cargo holds
Injected into mature wells for further oil extraction
Aerobic bacteria
Solid CO2 (dry ice) used as a refrigerant and for carbonation; CO2 used in packaging to extend storage shelf life
CO2 used in various processes
Biodegradation (aerobic decomposition) of waste
Both the diffusion and pumped confi gurations are compatible with the MicroDock II automated bump test and calibration system
Standard features of BW products:
• Continuous LCD shows real-time gas concentrations
• Water-resistant
• Automatic calibration procedure; compatible with BW MicroDock II automatic test and calibration station
• Full function self-test of sensor, battery status, circuit integrity and audible/visual alarms on start up
• Bright wide-angled visual alarm bars
• Built-in concussion-proof boot
GasAlertMicro 5 Specifi cations
Size
Weight
Temperature
5.7 x 2.9 x 1.5 in. / 14.5 x 7.4 x 3.8 cm
13.1 oz. / 370 g
-4 to +122°F / -20 to +50°C 14 to +104°F / -10 to +40°C (PID)
Alarms
- Visual, vibrating, audible (95 dB)
- Low, High, STEL, TWA, OL (over limit)
Tests
Sensor integrity, circuitry, battery and audible/visual alarms on activation, battery (continuous)
Pump
User options
Optional; Sample from up to 66 ft. / 20 m
Confi dence beep
Set STEL interval
Set TWA method
Sensor on/off
Latching alarms
Safe display mode
Stealth mode
Adjust Clock
Set datalogger rate
Passcode protection
Correction factor library (LEL, PID)
Combustible gas measurement (% LEL or % by volume methane)
O2 auto calibration on start up
Automatic backlight
Sleep mode
User-settable calibration gas level
Calibration due lockout
Daily bump test
Language choices (fi ve)
High resolution
Fast pump
Ratings
EMI/RFI: Complies with EMC Directive 89/336/EEC IP 65/66
Certifi cations and approvals
n Class I, Div. 1, Gr. A, B, C, D
American Bureau of Shipping - Toxic & PID models ATEX: X g II 1 G Ga Ex ia IIC T4* X g II 2 G - IR model only Ex d ia IIC T4* IECEx: Ga Ex ia IIC T4*
Ex d ia IIC T4* - IR model only
*Temperature codes may vary as a function of the batteries installed. Please see owner’s manual for a complete listing of compatible batteries and codes.
Warranty
Full two year warranty including sensors
(1 year NH3, Cl2, O3, ClO2 and PID lamp)
Additional GasAlertMicro 5 Features:
• Integral motorized pump option for remote sampling
• Equipped with internal vibrating alarm for high noise areas
• Two power options: AA alkaline or rechargeable hot-swappable battery packs
• Multi-language support in English, French, German, Spanish and Portuguese
Options and Accessories
Integral pump and battery charger
Confi ned space kit Belt holster Collapsible sampling
probe
For a complete list of accessories, please contact BW Technologies.
Sensor Specifi cations
Gas
H2S CO TwinTox (H TwinTox (CO) O
2
SO
2
PH
3
NH
3
NO
2
HCN Cl
2
ClO
2
O
3
PID (VOCs)
IR (CO
2)
Combustible gases
S)
2
Measuring
Range (ppm)
0-500 1.0 0.1 0-999 1.0 N/A 0-500 1.0 0.1 0-500 1.0 N/A
0-30.0% 0.1% N/A
0-150 1.0 0.1
0-5.0 1.0 0.1
0-100 1.0 0.1 0-99.9 1.0 0.1 0-30.0 1.0 0.1 0-50.0 1.0 0.1
0-1.0 0.1 0.01 0-1.0 0.1 0.01
0-1000 1 N/A
0-50,000
0-5.0% v/v
0-100% LEL
0-5.0% v/v
Default
Resolution (ppm)
50
0.01% 1%
0.1%
High Resolution
(ppm)
N/A N/A
N/A
Alarm set points for all sensors are user adjustable. Set point(s) are automatically displayed during instrument start up.
Locally available from
Corporate Headquarters
2840 - 2 Avenue S.E. USA 1.888.749.8878 Middle East +971.4.887.1766 Latin America +55.11.3475.1873 Calgary, AB, Canada T2A 7X9 Europe +44 (0)1295.700.300 S.E. Asia +65.6580.3468 Other Countries +1.403.248.9226 Phone: +1.403.248.9226 France +33 (0) 442.98.17.70 China +86.10.6786.7305 Toll free: 1.800.663.4164 Germany 49 (0) 2137.17.6522 Australia +61.3.9464.2770
www.gasmonitors.com info@gasmonitors.com
DUE TO ONGOING RESEARCH AND PRODUCT IMPROVEMENT, SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
© 2010 Honeywell International Ltd. All Rights Reserved.