BW Technologies GasAlert Extreme Quick Start Guide

50105442-061 EN-K4 [English] © BW Technologies 2016. All rights reserved.
Single Gas Detector
Quick Reference Guide
BW Technologies LP (BW) warrants the product to be free from defects in material and workmanship under normal use and service for a period of
two years, beginning on the date of shipment to the buyer. This warranty extends only to the sale of new and unused products to the original buyer. BW’s warranty obligation is limited, at BW’s option, to refund of the purchase price, repair or replacement of a defective product that is returned to a BW authorized service center within the warranty period. In no event shall BW’s liability hereunder exceed the purchase price actually paid by the buyer for the Product. This warranty does not include:
a) fuses, disposable batteries or the routine replacement of parts due to the normal wear and tear of the product arising from use; b) any product which in BW’s opinion, has been misused, altered, neglected or damaged, by accident or abnormal conditions of operation,
handling or use;
c) any damage or defects attributable to repair of the product by any person other than an authorized dealer, or the installation of unapproved
parts on the product; or
The obligations set forth in this warranty are conditional on:
a) proper storage, installation, calibration, use, maintenance and compliance with the product manual instructions and any other applicable
recommendations of BW;
b) the buyer promptly notifying BW of any defect and, if required, promptly making the product available for correction. No goods shall be
returned to BW until receipt by the buyer of shipping instructions from BW; and
c) the right of BW to require tha t the buyer provide proof of purchase such as the original invoice, bill of sale or packing slip to establish that the
product is within the warranty period.
THE BUYER AGREES THAT THIS WARRANTY IS THE BUYERS SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. BW SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR BASED ON CONTRACT, TORT OR RELIANCE OR ANY OTHER THEORY.
Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not apply to every buyer. If any provision of this warranty is held invalid or unenforceable by a court of competent jurisdiction, such holding will not affect the validity or enforceability of any other provision.

Contacting BW Technologies by Honeywell

USA: 1-888-749-8878 Canada: 1-800-663-4164 Europe: +44(0) 1295 700300 Other countries: +1-403-248-9226
Email us at: info@gasmonitors.com Visit BW Technologies by Honeywell’s website at: www.gasmonitors.com

GasAlert Extreme

Introduction

This quick reference guide provides basic information to oper­ate the GasAlert Extreme gas detector. For complete operating instructions, refer to the GasAlert Extreme User Manual pro­vided on the CD-ROM. The GasAlert Extreme gas detector (“the detector”) is designed to warn of hazardous gas levels above user defined alarm setpoints.
The detector is a personal safety device. It is your responsibility to respond properly to the alarm.

Note

If you have a multi-language detector, the detector is shipped with English as the default displayed language. Additional languages provided are French, German, Spanish, and Portuguese. The screens for the additional languages are displayed on the detector and in the corresponding quick reference guide.

Safety Information - Read First

Use the detector only as specified in this quick reference guide and user manual, otherwise the protection provided by the detector may be impaired.
Read the following Cautions before using the detector.
a Cautions
Warning: Substitution of components may impair
Intrinsic Safety.
Warning: To prevent ignition of flammable or
combustible atmospheres, disconnect power before servicing.
Warning: Use only the Panasonic CR-2PE/BN. Refer to
Replacing the Battery or Sensor.
Warning: To reduce the risk of ignition of a flammable
atmosphere, batteries must only be changed in a safe area free of hazardous gas.
• Calibrate only in a safe area that is free of hazardous gas in an atmosphere of 20.9% oxygen.
• Use only a sensor specifically designed for the GasAlert Extreme model.
• Do not deactivate the detector during a work shift.
1
GasAlert Extreme
Quick Reference Guide
Deactivating the detector resets the time-weighted average (TWA), short-term exposure limit (STEL), and maximum gas exposure values to 0.
• If the detector is damaged or parts are missing, contact
BW Technologies by Honeywell
• Do not use the detector if it is damaged. Before using the detector, inspect the case. Look for cracks and missing parts.
• If the detector has been disassembled, ensure the front and rear shells are properly aligned and fastened before activating the detector. Refer to Maintenance
• BW recommends to bump test the sensor before each day’s use to confirm its ability to respond to gas by exposing the detector to a gas concentration that exceeds the alarm setpoints. Manually verify that the audible and visual alarms are activated. For detectors with the calibration feature, calibrate the sensor if the reading is not within the specified limits.
• Calibrate the detector before first-time use, and then at least once every 180 days. For HCN detectors, calibrate once every 30 days.
immediately.
.
2
• Ensure the sensor screen is not blocked.
• Do not cover the sensor grill with hands. To avoid possible damage to the detector, adhere to the
following:
• Do not expose the detector to electrical shock and/or severe continuous mechanical shock.
• The oxygen GasAlert Extreme detector is classified by Underwriters Laboratories Inc. up to an atmosphere of 21% oxygen.
• Do not attempt to disassemble, adjust, or service the detector unless instructions for that procedure are contained in the user manual, and/or that part is listed as a replacement part. Use only BW Technologies by Honeywell replacement parts. Refer to Replacement Parts and Accessories.
• The detector warranty will be voided if customer personnel or third parties damage the detector during repair attempts. Non-BW Technologies by Honeywell repair/service attempts void this warranty.
• Products may contain materials that are regulated for transportation under domestic and international dangerous goods regulations. Return product in compliance with appropriate dangerous goods regulations. Contact freight carrier for further instructions.

Informations de sécurité – À lire au préalable

Utiliser le détecteur dans le seul but indiqué dans ce mémento et dans le manuel d'utilisation, sous peine de porter préjudice à la protection assurée par le détecteur.
Lire les Mises en garde suivantes avant d'utiliser le détecteur.
a Mises en garde
Avertissement : Le remplacement d'un composant de
l'appareil peut compromettre la sécurité intrinsèque du détecteur.
Avertissement :Pour éviter l'inflammation
d'atmosphères inflammables ou combustibles, couper l'alimentation électrique avant tout entretien.
Avertissement : Utiliser uniquement des piles
Panasonic CR-2PE/BN. Se reporter à la section
Replacing the Battery or Sensor.
Avertissement : Pour réduire le risque d'ignition dans
les atmosphères inflammables, les piles doivent être changées in a dans une zone sûre, exempte de gaz dangereux.
• Veillez à effectuer l'étalonnage dans une zone sûre, exempte de gaz dangereux, dans une atmosphère contenant 20,9 % d'oxygène.
• Utiliser uniquement les capteurs spécialement conçus pour le modèle GasAlert Extreme.
• Ne pas désactiver le détecteur au cours d'une période de travail. La désactivation du détecteur permet de remettre à zéro la moyenne pondérée dans le temps (TWA), la limite d'exposition à court terme (STEL) et les
Informations de sécurité – À lire au préalable
GasAlert Extreme
valeurs d'exposition maximale au gaz.
• Si le détecteur est endommagée ou que des pièces sont manquantes, contacter immédiatement BW
Technologies by Honeywell.
• Ne pas utiliser le détecteur s'il est endommagé. Avant d'utiliser le détecteur, inspecter le boîtier. S'assurer qu'aucune pièce ne manque et vérifier l'absence de fissures.
• Si le détecteur a été démonté, s'assurer que les coques avant et arrière sont correctement alignées et serrées avant d'activer le détecteur. Se reporter à la section
Maintenance
• Avant chaque utilisation quotidienne, BW recommande d'effectuer un test fonctionnel du capteur afin de vérifier qu'il réagisse bien aux gaz présents, en exposant le détecteur à une concentration de gaz supérieure aux seuils d'alarme. Vérifier manuellement que les alarmes sonore et visuelle sont activées. Pour les détecteurs équipés de la fonction d'étalonnage, étalonner le capteur si la valeur ne respecte pas les limites spécifiées.
• Étalonner le détecteur avant sa première utilisation, puis une fois tous les 180 jours. Pour les détecteurs HCN, effectuer un étalonnage tous les 30 jours.
.
3
GasAlert Extreme
Quick Reference Guide
• Vérifier que le filtre du capteur n'est pas bouché.
• Ne pas couvrir la grille du capteur avec vos mains.
• Ne pas placer le détecteur près de la bouche ou des épaules.
Pour éviter des dommages possibles sur le détecteur, respecter les consignes suivantes :
• Ne pas soumettre le détecteur à des chocs électriques ni à d'importants chocs mécaniques continus.
• Le détecteur d'oxygène GasAlert Extreme est classé par l'organisme Underwriters Laboratories Inc. apte à une utilisation jusque dans une atmosphère de 21 % d'oxygène.
• Ne pas essayer de démonter, ajuster ou entretenir le détecteur à moins que des instructions soient spécifiées dans le manuel d'utilisation et/ou que la pièce en question soit répertoriée comme pièce de rechange. Utiliser des pièces de rechange BW Technologies by Honeywell uniquement. Se reporter à la rubrique Pièces de rechange et accessoires.
• La garantie du détecteur sera annulée si le personnel du client ou des tiers endommagent le détecteur lors d'une tentative de réparation. Les tentatives de réparation/ entretien non effectuées par BW Technologies by Honeywell annulent la présente garantie.
• Les produits peuvent contenir des matériaux qui sont réglementés pour le transport en vertu des règlements nationaux et internationaux de marchandises dangereuses. Retourner le produit conformément à la réglementation sur les marchandises dangereuses
4
appropriées. Contactez transporteur pour plus d'instructions.

Parts of the GasAlert Extreme

Parts of the GasAlert Extreme
GasAlert Extreme
Item Description
1 Visual alarms bars (LEDs)
2 Liquid crystal display (LCD)
3 Pushbuttons
4 Audible alarm
5 Sensor and sensor grill
6 Infrared (IR) communication port
7 Alligator clip
5
GasAlert Extreme
Quick Reference Guide

Display Elements

Note

Press and hold (until the backlight activates) any button to activate the backlight for 6 seconds. When the backlight option is enabled, the backlight automatically activates for 3 seconds whenever there is insufficient light to view the LCD. The detector is shipped with the backlight option enabled.
The backlight does not activate when stealth mode is enabled.
6
Item Description
1 Numeric value
2 Gas cylinder
3 Automatic span sensor
4 Passcode lock
5 Set alarm setpoints and user options
6 Maximum gas exposure
7 Alarm conditions
8 Battery
9 Data transmission
10 Alarm or alarm setpoint
11 Automatically zero sensor
12 Optional datalogger indicator
13 Parts per million (ppm)
14 Percentage by volume (% vol.)
15
Percentage by lower explosive limit (% LEL) (future use)