BVA Hydraulics HL10002 User Manual

HL1001-M0 rev 12/07
Single Acting,
Low Profile Cylinders
Instruction Manual
MODELS: HL1001, HL2002, HL3002, HL5002 & HL10002
SFA Companies 10939 N. Pomona Ave. Kansas City, MO 64153
E-mail: sales@bvahydraulics.com Website: www.bvahydraulics.com
This is the safety alert symbol. It is used to alert you to potential personal injury hazards.
!
Obey all safety messages that follow this symbol to avoid possible injury or death.
Maximum Operating Pressure 10,000 PSI
! ADVERTENCIA
• Leer, comprender, y seguir las instrucciónes antes de utilizar el aparato.
• El manual de instrucciónes y la información de seguridad deben estar comunicado en lengua del operador antes del uso.
• No seguir estas indicaciónes puede causar daños personales o materiales.
Printed in Taiwan
SAFETY and GENERAL INFORMATION
Save these instructions.
understand the information contained within. The owner and operator shall have an understanding of this product and safe operating procedures before attempting to use this product. Instructions and safety information shall be conveyed in the operator’s native language before use of this product is authorized. Make certain that the operator thoroughly understands the inherent dangers associated with the use and misuse of the product. If any doubt exists as to the safe and proper use of this product as outlined in this factory authorized manual, remove from service immediately.
Inspect before each use.
bent, cracked or otherwise damaged parts are noted. If the cylinder has been or suspected to have been subjected to a shock load (a load dropped suddenly, unexpectedly upon it), discontinue use until checked out by a BVA Hydraulics authorized service center. Owners and operators of this equipment shall be aware that the use and subsequent repair of this equipment may require special training and knowledge. It is recommended that an annual inspection be done by qualified personnel and that any missing or damaged parts, decals, warning/safety labels or signs be replaced with BVA Hydraulics authorized replacement parts only. Any cylinder that appears to be damaged in any way, is worn or operates abnormally shall be removed from service immediately until such time as repairs can be made.
For your safety, read and
Do not use if leaking, broken,
PRODUCT DESCRIPTION
BVA Hydraulics Single Acting Cylinder is designed for rated capacity pushing, spreading and pressing jobs. A wide variety of applications exist for this category of product. Special skill, knowledge and training may be required for a specific task and the product may not be suitable for all the jobs described above. Unsuitable applications would include applications that call for a device to move, level or support persons, animals, hazardous materials, mobile homes/dwellings in general, mirrors and/or plate glass, and/or to connect/secure hatches, components, etc. between bulkheads. The user ultimately must make the decision regarding suitability of the product for any given task and therefore accept responsibility for that decision. I supported by appropriate mechanical means.
NEVER use hydraulic cylinder as a support device!
!
!
Always check connections before using. Alteration of these products is strictly prohibited. Use only those adapters and attachments provided and approved by the manufacturer.
!
WARNING
property damage, ensure that the rated working pressure of each pressurized attachment be equal to or greater than the rated working pressure developed by the hydraulic pump.
mmediately
: To reduce the risk of personal injury and/or
after lifting, loads must be
Model
Number
HL1001 10
Cylinder
Capacity
(ton)
Stroke
(in)
1.50
Ram Plunger
Dust Cover
Female Coupler
3/8” NPTF
Figure 1 - Low Profile Cylinder Components
SPECIFICATIONS
Cylinder
2
)
Capacity
Effective
Area
(in
2.35 3.53
Oil
(in
3
)
Collapsed
Height
(in)
3.48 4.98
Extended
Height
(in)
Weight
(lb.)
5.7
Cylinder Housing
Ram
Plunger
Dia.
(in)
Plunger
Mounting
at
Cylinder Housing
Dia.
(in)
Internal
Pressure
Capacity
(psi)
8,511 2.75 1.50 M4
Ram
Hole
HL2002
HL3002
HL5002
HL10002
20 1.75 4.37
30 2.44 6.49 15.84 4.61
50 2.36
100
2.24 19.64
9.87 23.29
7.65 3.90
4.80 7.17
44.07 5.55 7.80
5.65
7.05 15 9,245
2
11 9,153 3.63 2.00 M4
4.00
21.8 10,132 4.88
45.4 10,183
6.50
2.50
2.76 M5
3.54 M8
M5
INSTALLATION
IMPORTANT! Use an approved, high-grade pipe sealant to
seal all hydraulic connections.
1.
Remove the dust cover and rubber plug from coupler
2. Inspect all threads and fittings for signs of wear or damage, and replace as needed. Clean all threads and fittings.
3. Connect hydraulic hose from hydraulic pump to the cylinder coupler. Ensure that there are no fluid leaks.
4. Install in-line pressure gauge.
5. Check for leaks in system and have repaired by qualified personnel.
Note: The use of cylinder attachments or extensions reduces the cylinder capacity by at least 50% per attachment/ extension.
.
! WARNING
Before operating the pump, tighten all hose
!
connections with proper tools. Do not overtighten. Connections should only be tightened securely and leak­free. Overtightening can cause premature thread failure or high pressure fittings to burst.
Before repairs are made, depressurize cylinder.
!
Tips for hydraulic hoses & fluid transmission lines:
• Avoid short runs of straight line tubing. Straight line runs do not provide for expansion and contraction due to
pressure and/or temperature changes.
• Reduce stress in tube lines. Long tubing runs should be supported by brackets or clips.
may
property damage.
• Study, understand, and follow all instructions provided with and on this device before use.
with the correct operation, maintenance, and use of cylinders.
Wear protective gear when
operating hydraulic equipment.
This device is NOT suitable for use as support device! As the load is lifted, use blocking and cribbing to guard against a falling load. clear of a lifted load before it is properly Never rely on hydraulic pressure to support a load.
during operation.
• Do not exceed rated capacity of the cylinder or
Do not connect a cylinder to a pump with higher
pressure rating.
• Do not subject cylinder to a shock loads, a load dropped suddenly, causing the system pressure to exceed rated pressure.
Failure to comply with the following warnings
result in personal injury as well as
• The user must be a qualified operator familiar
Stay
supported.
Crush Hazard. Keep hands and feet away from cylinder and workpiece
any equipment in the system. The cylinder is designed for a max. pressure of 10,000 psi.
Do not pull, position or move cylinder setup by the hose. Use carrying handle or other means of safe transport.
Do not handle pressurized hoses. Never attempt to grasp a leaking pressurized hose. Ensure to release the system pressure before disconnecting hydraulic hose or connections.
Hydraulic fluid can ignite and burn. Keep
heat. fluid leaks. Heat also weakens hose materials.
Cylinder must be on a stable base which is able to support the load while pushing or lifting. Use shims, friction material or constrains to prevent slippage of the base or load. Ensure cylinder is fully engaged into/onto adapters, extension accessories.
Center load on cylinder. Distribute load evenly across the entire saddle surface. Do not off-center loads on a cylinder. The load can tip or the cylinder can “kick out”.
Never try to disassemble a hydraulic cylinder, refer repairs to qualified, authorized personal. Contact BVA Hydraulics tech service for authorized service center.
Do not subject hose to sharp objects or heavy impact.
hydraulic equipment away from flames and
Excessive heat will soften seals, resulting in
Heavy
The system operating pressure must not exceed
measuring instrument to monitor the operating pressure. Burst hazard exists if hose, connection or any other component in the system exceed its rated pressure.
Avoid damaging hydraulic hose. Do not allow hose to kink, twist, curl, crush, cut or bend so tightly that fluid flow within the hose is blocked or reduced. Periodically inspect the hose for wear.
the pressure rating of the lowest rated component
the system. Install a pressure gauge or other load
Hose material or seals must not come in contact with corrosive materials such as battery acid, creosote-impregnated objects and wet paint. Never paint a coupler or hose.
• No alteration shall be made to the cylinder.
• Use only factory authorized fasteners, accessories and hydraulic fluid.
3
Loading...
+ 5 hidden pages