HL1001-M0 rev 12/07
Single Acting,
Low Profile Cylinders
Instruction Manual
MODELS: HL1001, HL2002, HL3002, HL5002 & HL10002
SFA Companies 10939 N. Pomona Ave. Kansas City, MO 64153
Tel: 888-332-6419 * Fax: 816-891-6599
E-mail: sales@bvahydraulics.com Website: www.bvahydraulics.com
This is the safety alert symbol. It is used to alert you to potential personal injury hazards.
!
Obey all safety messages that follow this symbol to avoid possible injury or death.
Maximum Operating Pressure 10,000 PSI
! ADVERTENCIA
• Leer, comprender, y seguir las instrucciónes antes de utilizar el aparato.
• El manual de instrucciónes y la información de seguridad deben estar comunicado en lengua del operador
antes del uso.
• No seguir estas indicaciónes puede causar daños personales o materiales.
Printed in Taiwan

SAFETY and GENERAL INFORMATION
Save these instructions.
understand the information contained within. The owner and
operator shall have an understanding of this product and safe
operating procedures before attempting to use this product.
Instructions and safety information shall be conveyed in
the operator’s native language before use of this product
is authorized. Make certain that the operator thoroughly
understands the inherent dangers associated with the use
and misuse of the product. If any doubt exists as to the safe
and proper use of this product as outlined in this factory
authorized manual, remove from service immediately.
Inspect before each use.
bent, cracked or otherwise damaged parts are noted. If the
cylinder has been or suspected to have been subjected to
a shock load (a load dropped suddenly, unexpectedly upon
it), discontinue use until checked out by a BVA Hydraulics
authorized service center. Owners and operators of this
equipment shall be aware that the use and subsequent
repair of this equipment may require special training and
knowledge. It is recommended that an annual inspection
be done by qualified personnel and that any missing or
damaged parts, decals, warning/safety labels or signs be
replaced with BVA Hydraulics authorized replacement parts
only. Any cylinder that appears to be damaged in any way, is
worn or operates abnormally shall be removed from service
immediately until such time as repairs can be made.
For your safety, read and
Do not use if leaking, broken,
PRODUCT DESCRIPTION
BVA Hydraulics Single Acting Cylinder is designed for rated
capacity pushing, spreading and pressing jobs. A wide variety
of applications exist for this category of product. Special skill,
knowledge and training may be required for a specific task
and the product may not be suitable for all the jobs described
above. Unsuitable applications would include applications
that call for a device to move, level or support persons,
animals, hazardous materials, mobile homes/dwellings in
general, mirrors and/or plate glass, and/or to connect/secure
hatches, components, etc. between bulkheads. The user
ultimately must make the decision regarding suitability of the
product for any given task and therefore accept responsibility
for that decision. I
supported by appropriate mechanical means.
NEVER use hydraulic cylinder as a support device!
!
!
Always check connections before using. Alteration
of these products is strictly prohibited. Use only those
adapters and attachments provided and approved by the
manufacturer.
!
WARNING
property damage, ensure that the rated working pressure of
each pressurized attachment be equal to or greater than the
rated working pressure developed by the hydraulic pump.
mmediately
: To reduce the risk of personal injury and/or
after lifting, loads must be
Model
Number
HL1001 10
Cylinder
Capacity
(ton)
Stroke
(in)
1.50
Ram Plunger
Dust Cover
Female Coupler
3/8” NPTF
Figure 1 - Low Profile Cylinder Components
SPECIFICATIONS
Cylinder
2
)
Capacity
Effective
Area
(in
2.35 3.53
Oil
(in
3
)
Collapsed
Height
(in)
3.48 4.98
Extended
Height
(in)
Weight
(lb.)
5.7
Cylinder
Housing
Ram
Plunger
Dia.
(in)
Plunger
Mounting
at
Cylinder
Housing
Dia.
(in)
Internal
Pressure
Capacity
(psi)
8,511 2.75 1.50 M4
Ram
Hole
HL2002
HL3002
HL5002
HL10002
20 1.75 4.37
30 2.44 6.49 15.84 4.61
50 2.36
100
2.24 19.64
9.87 23.29
7.65 3.90
4.80 7.17
44.07 5.55 7.80
5.65
7.05 15 9,245
2
11 9,153 3.63 2.00 M4
4.00
21.8 10,132 4.88
45.4 10,183
6.50
2.50
2.76 M5
3.54 M8
M5

INSTALLATION
IMPORTANT! Use an approved, high-grade pipe sealant to
seal all hydraulic connections.
1.
Remove the dust cover and rubber plug from coupler
2. Inspect all threads and fittings for signs of wear or damage,
and replace as needed. Clean all threads and fittings.
3. Connect hydraulic hose from hydraulic pump to the cylinder
coupler. Ensure that there are no fluid leaks.
4. Install in-line pressure gauge.
5. Check for leaks in system and have repaired by qualified
personnel.
Note: The use of cylinder attachments or extensions reduces
the cylinder capacity by at least 50% per attachment/
extension.
.
! WARNING
Before operating the pump, tighten all hose
!
connections with proper tools. Do not overtighten.
Connections should only be tightened securely and leakfree. Overtightening can cause premature thread failure or
high pressure fittings to burst.
Before repairs are made, depressurize cylinder.
!
Tips for hydraulic hoses & fluid transmission lines:
• Avoid short runs of straight line tubing. Straight line runs
do not provide for expansion and contraction due to
pressure and/or temperature changes.
• Reduce stress in tube lines. Long tubing runs should be
supported by brackets or clips.
may
property damage.
• Study, understand, and follow all instructions
provided with and on this device before use.
with the correct operation, maintenance, and use of
cylinders.
Wear protective gear when
operating hydraulic equipment.
This device is NOT suitable for use as support
device! As the load is lifted, use blocking and
cribbing to guard against a falling load.
clear of a lifted load before it is properly
Never rely on hydraulic pressure to support a load.
during operation.
• Do not exceed rated capacity of the cylinder or
•
Do not connect a cylinder to a pump with higher
pressure rating.
• Do not subject cylinder to a shock loads, a load
dropped suddenly, causing the system pressure to
exceed rated pressure.
Failure to comply with the following warnings
result in personal injury as well as
• The user must be a qualified operator familiar
Stay
supported.
Crush Hazard. Keep hands and feet
away from cylinder and workpiece
any equipment in the system. The cylinder is
designed for a max. pressure of 10,000 psi.
Do not pull, position or move cylinder setup by
the hose. Use carrying handle or other means
of safe transport.
Do not handle pressurized hoses. Never attempt
to grasp a leaking pressurized hose. Ensure to
release the system pressure before disconnecting
hydraulic hose or connections.
Hydraulic fluid can ignite and burn. Keep
heat.
fluid leaks. Heat also weakens hose materials.
Cylinder must be on a stable base which is able
to support the load while pushing or lifting. Use
shims, friction material or constrains to prevent
slippage of the base or load. Ensure cylinder is fully engaged
into/onto adapters, extension accessories.
Center load on cylinder. Distribute load evenly
across the entire saddle surface. Do not
off-center loads on a cylinder. The load can tip
or the cylinder can “kick out”.
Never try to disassemble a hydraulic cylinder,
refer repairs to qualified, authorized personal.
Contact BVA Hydraulics tech service for authorized
service center.
Do not subject hose to sharp objects or
heavy impact.
hydraulic equipment away from flames and
Excessive heat will soften seals, resulting in
Heavy
The system operating pressure must not exceed
measuring instrument to monitor the operating pressure. Burst
hazard exists if hose, connection or any other component in
the system exceed its rated pressure.
Avoid damaging hydraulic hose. Do not allow
hose to kink, twist, curl, crush, cut or bend so
tightly that fluid flow within the hose is blocked or
reduced. Periodically inspect the hose for wear.
the pressure rating of the lowest rated component
the system. Install a pressure gauge or other load
Hose material or seals must not come in
contact with corrosive materials such as
battery acid, creosote-impregnated objects
and wet paint. Never paint a coupler or hose.
• No alteration shall be made to the cylinder.
• Use only factory authorized fasteners,
accessories and hydraulic fluid.
3