This is the safety alert symbol. It is used to alert you to potential personal injury hazards.
!
Obey all safety messages that follow this symbol to avoid possible injury or death.
- 55 Ton Capacity
- 75 Ton Capacity
- 100 Ton Capacity
Maximum Operating Pressure 10,000 PSI
! ADVERTENCIA
• Leer, comprender, y seguir las instrucciónes antes de utilizar el aparato.
• El manual de instrucciónes y la información de seguridad deben estar comunicado en lengua del operador
antes del uso.
• No seguir estas indicaciónes puede causar daños personales o materiales.
Printed in Taiwan
SAFETY and GENERAL INFORMATION
Save these instructions. For your safety, read and
understand the information contained within. The owner and
operator shall have an understanding of this product and safe
operating procedures before attempting to use this product.
Instructions and safety information shall be conveyed in
the operator’s native language before use of this product
is authorized. Make certain that the operator thoroughly
understands the inherent dangers associated with the use
and misuse of the product. If any doubt exists as to the safe
and proper use of this product as outlined in this factory
authorized manual, remove from service immediately.
Inspect before each use. Do not use if leaking, broken,
bent, cracked or otherwise damaged parts are noted. If the
cylinder has been or suspected to have been subjected to
a shock load (a load dropped suddenly, unexpectedly upon
it), discontinue use until checked out by a BVA Hydraulics
authorized service center. Owners and operators of this
equipment shall be aware that the use and subsequent
repair of this equipment may require special training and
knowledge. It is recommended that an annual inspection
be done by qualied personnel and that any missing or
damaged parts, decals, warning/safety labels or signs be
replaced with BVA Hydraulics authorized replacement parts
only. Any cylinder that appears to be damaged in any way, is
worn or operates abnormally shall be removed from service
immediately until such time as repairs can be made.
hatches, components, etc. between bulkheads. The user
ultimately must make the decision regarding suitability of the
product for any given task and therefore accept responsibility
for that decision. Immediately after lifting, loads must be
supported by appropriate mechanical means.
!
NEVER use hydraulic cylinder as a support device!
Always check connections before using. Alteration
!
of these products is strictly prohibited. Use only those
adapters and attachments provided and approved by the
manufacturer.
!
WARNING: To reduce the risk of personal injury and/or
property damage, ensure that the rated working pressure of
each pressurized attachment be equal to or greater than the
rated working pressure developed by the hydraulic pump.
Saddle
Ram Plunger
Collar
Protecting Cap
Handle
PRODUCT DESCRIPTION
BVA Hydraulics Single Acting Cylinder is designed for rated
capacity pushing, spreading and pressing jobs. A wide variety
of applications exist for this category of product. Special skill,
knowledge and training may be required for a specic task
and the product may not be suitable for all the jobs described
above. Unsuitable applications would include applications
that call for a device to move, level or support persons,
animals, hazardous materials, mobile homes/dwellings in
general, mirrors and/or plate glass, and/or to connect/secure
Dust Cover
Female Coupler
3/8” NPTF
Figure 1 - Typical Single Acting Cylinder Components
SPECIFICATIONS
Model
Number
H5502
H55043.9843.698.9412.9142.6
H55066.2268.3411.1417.3657.5
H551313.27145.7718.1531.4286.9
H7506
H751313.11211.0719.3731.42121.3
Cylinder
Capacity
(ton)
55
75
Stroke
(in)
2.01
6.14
Cylinder
Effective
Area
(in2)
10.99
16.10
Oil
Collapsed
Capacity
(in3)
22.066.938.9434.2
98.8811.2217.3673.2
Height
(in)
Extended
Height
(in)
Weight
(lb.)
Cylinder
Housing
Internal
Pressure
Capacity
(psi)
10,0005.001/2”-13UNC5”-12
9,3175.79N/A5 3/4”-12
at
Cylinder
Housing
Dia.
(in)
Base
Mounting
Hole
(in)
Collar
Thread
(in)
H10002A
H100066.61136.0814.0620.69121.3
H1001010.24210.6017.6827.93157.2
100
2.01
41.348.6210.6369.4
20.57
2
6.25N/A6 1/4”-12
9,723
6.973/4”-10UNC 6 7/8”-12
INSTALLATION
IMPORTANT! Use an approved, high-grade pipe sealant to
seal all hydraulic connections.
1.
Remove the dust cover and rubber plug from coupler
2. Inspect all threads and ttings for signs of wear or damage,
and replace as needed. Clean all threads and ttings.
3. Connect hydraulic hose from hydraulic pump to the cylinder
coupler. Ensure that there are no uid leaks.
4. Install in-line pressure gauge.
5. Check for leaks in system and have repaired by qualied
personnel.
Note: The use of cylinder attachments or extensions reduces
the cylinder capacity by at least 50% per attachment/
extension.
.
! WARNING
Before operating the pump, tighten all hose
!
connections with proper tools. Do not overtighten.
Connections should only be tightened securely and leakfree. Overtightening can cause premature thread failure or
high pressure ttings to burst.
Before repairs are made, depressurize cylinder.
!
Tips for hydraulic hoses & uid transmission lines:
• Avoid short runs of straight line tubing. Straight line runs
do not provide for expansion and contraction due to
pressure and/or temperature changes.
• Reduce stress in tube lines. Long tubing runs should be
supported by brackets or clips.
may
property damage.
• Study, understand, and follow all instructions
provided with and on this device before use.
with the correct operation, maintenance, and use of
cylinders.
Wear protective gear when
operating hydraulic equipment.
This device is NOT suitable for use as support device! As the load is lifted, use blocking and
cribbing to guard against a falling load.
clear of a lifted load before it is properly
Never rely on hydraulic pressure to support a load.
during operation.
• Do not exceed rated capacity of the cylinder or
•
Do not connect a cylinder to a pump with higher
pressure rating.
• Do not subject cylinder to a shock loads, a load
dropped suddenly, causing the system pressure to
exceed rated pressure.
Failure to comply with the following warnings
result in personal injury as well as
• The user must be a qualied operator familiar
Stay
supported.
Crush Hazard. Keep hands and feet
away from cylinder and workpiece
any equipment in the system. The cylinder is
designed for a max. pressure of 10,000 psi.
Do not pull, position or move cylinder setup by
the hose. Use carrying handle or other means
of safe transport.
Do not handle pressurized hoses. Never attempt
to grasp a leaking pressurized hose. Ensure to
release the system pressure before disconnecting
hydraulic hose or connections.
Hydraulic uid can ignite and burn. Keep
heat.
uid leaks. Heat also weakens hose materials.
Cylinder must be on a stable base which is able
to support the load while pushing or lifting. Use
shims, friction material or constrains to prevent
slippage of the base or load. Ensure cylinder is fully engaged
into/onto adapters, extension accessories.
Center load on cylinder. Distribute load evenly
across the entire saddle surface. Do not
off-center loads on a cylinder. The load can tip
or the cylinder can “kick out”.
Never try to disassemble a hydraulic cylinder,
refer repairs to qualied, authorized personal.
Contact BVA Hydraulics tech service for authorized
service center.
Do not subject hose to sharp objects or
heavy impact.
hydraulic equipment away from ames and
Excessive heat will soften seals, resulting in
Heavy
The system operating pressure must not exceed
measuring instrument to monitor the operating pressure. Burst
hazard exists if hose, connection or any other component in
the system exceed its rated pressure.
Avoid damaging hydraulic hose. Do not allow
hose to kink, twist, curl, crush, cut or bend so
tightly that uid ow within the hose is blocked or
reduced. Periodically inspect the hose for wear.
the pressure rating of the lowest rated component
the system. Install a pressure gauge or other load
Hose material or seals must not come in
contact with corrosive materials such as
battery acid, creosote-impregnated objects
and wet paint. Never paint a coupler or hose.
accessories and hydraulic uid.
3
•
No alteration shall be made to the cylinder.
•
Use only factory authorized fasteners,
BEFORE USE
1. Before using this product, read the owner's manual
completely and familiarize yourself thoroughly with the
product, its components and recognize the hazards
associated with its use.
2. Verify that the product and the application are compatible.
If in doubt, call BVA Hydraulics Technical Service (888)
332-6419.
3. Inspect before each use. Do not use if bent, broken, leaking
or damaged components are noted.
4.
Replace worn or damaged parts and assemblies with BVA
Hydraulics authorized replacement parts only. Lubricate
as instructed in Maintenance Section.
5. Ensure method of conrming load is accurate and working
properly. Have gauge or load cell accuracy veried by
qualied personnel on a yearly basis.
OPERATION
Operate the hydraulic pump to advance and retract the
cylinder. Do not continue pumping when cylinder is fully
extended. Internal pressure will build up and may damage
the seal of the cylinder.
To help prevent material fatigue if the cylinder is to
!
be used in a continuous application, the load should
not exceed 85% of the rated capacity.
Your cylinder, hose(s), couplings and pump all must
!
be rated for the same maximum operating pressure,
correctly connected and compatible with the hydraulic uid
used. An improperly matched system can cause the system
to fail.
All personnel must be clear before lowering load.
!
MAINTENANCE
1. Inspect hoses and connections daily. Replace damaged
components immediately with BVA Hydraulics Replacement
Parts only.
2. Tighten connections as needed. Use pipe thread sealing
compound when servicing connections.
3. Always use clean, approved hydraulic uid and change as
recommended or sooner if the uid becomes contaminated
instructions for changing and adding hydraulic uid. Use
only good quality hydraulic uid. We recommend Mobil
DTE13M or equivalent when using with hand pump or air
pump; BVA Hydraulics Oil (F01) or equivalent when using
with electric pump. Never use brake uid, transmission
uid, turbine oil, motor oil, alcohol, glycerin etc. Use of
other than good quality hydraulic oil will void warranty and
damage the cylinder, pump, hose etc.
4.
Use an approved, high-grade pipe thread sealant to seal all
hydraulic connections. Teon tape can be used if only one
layer of tape is used and it is applied carefully (two threads
back) to prevent the tape from being introduced into hydraulic
system. A piece of tape could travel through the system and
obstruct the ow of uid and adversely affect function.
Lubrication & Cleaning
Keep cylinder clean at all times.
1. Any exposed threads (male or female) must be cleaned
and lubricated regularly, and protected from damage.
Lubricate with light machine oil.
2. If a cylinder or ram has been exposed to rain, snow,
sand, airborne abrasive, or any corrosive environment, it
must be cleaned, lubricated, and protected immediately
after exposure. Daily clean exposed ram with clean cloth
dampened with light machine oil. Protect exposed ram
from the elements at all times.
3. Keep the hydraulic system as free of dirt as possible. When
not in use, couplers must be sealed with dust covers. All
hose connections must be free of dirt and grime. Any
equipment attached to the cylinder must be kept clean.
Storage
Cylinders should be stored vertically with ram plunger fully
retracted in a dry, protected area, not exposed to corrosive
vapor, dust or other harmful elements. When a cylinder has
not been used for a period of 4 months, it should be connected
to a pump and fully extended and then retracted a minimum
of 5 times. This cycle will lubricate the cylinder wall, reducing
the possibility of corrosion and damage thereof.
How to remove faulty coupler:
If cylinder does not retract,
1. Secure load by other means.
2. Depressurize pump and hose.
3. Remove the cylinder from application.
4. Disconnect and replace with new coupler.
Important: Do not attempt to grasp with pliers or wrench
without rst wrapping the jaws of such tool with rags or
similar padding.
How to bleed air from system:
1. Place pump at a higher elevation than the hose and
cylinder as shown in Figure 2.
2. Operate pump to fully extend and retract the cylinder 2 or
3 times. The objective is to force the air bubbles up hill
and back to the pump reservoir.
3. Follow pump instruction manual to bleed the air from
pump reservoir. On most pumps, air can escape by
opening the oil ller plug/screw.
Figure 2 - Illustration to bleed air from system