Bussmann SPP40SP1120SN, SPP40SP2240PN, SPP40SP3240DLG, SPP40SP3480DLG, SPP40SP3208WYG Data Sheet

...
S
2-1/16” 2-1/16”
1-11/16”
1-11/16”
4-1/8”
3-3/16”
4-1/16”
3-3/8”
7/8”
1-1/16” Dia.
URGEPROTECTIONMADESIMPLE™ FORLIGHTCOMMERCIAL
URGE
S
POD™ PRO SPD
FOR
UL 1449 3rdEdition Listed Loadside and Lineside Protection
Description
The Cooper Bussmann SurgePOD™ PRO is a Type 1 UL Listed 1449 3rdEdition surge protective device suitable for installation on both the loadside or lineside of the service entrance overcurrent protective device.
Available in popular voltage and system specific versions to match common residential and light commercial electrical system and equipment requirements. The SurgePOD PRO delivers superior surge protection using MOV thermal disconnect technology that eliminates the need for additional overcurrent protection.
Parallel connection to the electrical system permits the SurgePOD PRO SPD to be installed on any ampacity panel.
rd
• Type 1 UL 1449 3 and installed on the loadside or lineside of the service entrance overcurrent protective device
• Voltage specific models precisely match and protect electrical systems and equipment better than “one-size-fits-all” SPDs
• Thermal disconnect technology eliminates the need for additional fusing
• Compact UV resistant NEMA 4X enclosure for indoor or outdoor applications
easyID™ LED status indicator provides surge protection status at a glance
Edition Listed SPDs are easily selected
SPP40SP1120SN SPP40SP2240PN
& R
ESIDENTIALAPPLICATIONS
Status Indicator
SPP40SP3240DLG SPP40SP3480DLG
NEMA 4X Rated Pro
Type 1 UL Listed SPD
easyID™ LED
SPP40SP3208WYG SPP40SP3480WYG
Dimensions - in
0213 BU-SB13071 Page 1 of 3 Data Sheet 10033
Type 1 SPD Part Number System
SPP = Product Series
Surge Protection PRO
Surge Rating
40S = 40kA max discharge current
No of Wires/Poles
P1 = 1 P2 = 2 P3 = 3 P4 = 4
Rated System Voltage
120, 208, 240, 480Vac
System
SN = Single-Phase 2 Wire, 2 Connection Points PN = Split-Phase, 3 Wire, 3 Connection Points DLG = Three-Phase Delta 3 Wire + G, 4 Connection Points WYG = Three-Phase Wye 3 Wire, 4 Connection Points
SPP 40S PX XXX XXX
SurgePOD™ PRO Technical Information
Nominal Max. Continuous
System Operating AC Connection
Catalog Number Voltage Voltage (MCOV) (VC) System Type Points
SPP40SP1120SN 120V 150V Single-Phase 2 Wire 2 SPP40SP2240PN 120/240V 150V Split Phase 3 Wire 3 SPP40SP3240DLG 240V 320V Three-Phase Delta 3 Wire + G 4 SPP40SP3480DLG 480V 550V Three-Phase Delta 3 Wire + G 4 SPP40SP3208WYG 208V 150V Three-Phase Wye 3 Wire + G 4 SPP40SP3480WYG 480V 320V Three-Phase Wye 3 Wire + G 4
Specifications (for all SurgePOD PRO units) Values
Short Circuit Current Rating (SCCR) 200kA Nominal Discharge Current (8x20µs) I Max. Discharge Current (8x20µs) I Response Time (ns) t
A
max
n
10kA 40kA
<25ns Frequency 50/60Hz Operating State/Fault Indication Bi-Color LED - Green (good) / Red (replace) Conductor Length / Guage 18 inches, 10 AWG Stranded Tinned Copper Mounting Chase Nipple / Bracket* Enclosure / Flammability Ratings NEMA 4X - UL 94-5VA Degree of Protection (Installed State) IP20 (finger-safe) SPD Install Location Indoor/Outdoor Circuit Location Lineside or Loadside of service entrance overcurrent protective device Standard UL 1449 3rdEdition Type 1 Listed SPD Agency Information cULus, RoHS Compliant Product Warranty 2 Years** Operating Temperature -40˚C to +65˚C Maximum Operating Altitude 12000FT
* Customer-supplied bracket.
** See Cooper Bussmann SPD Limited Warranty Statement (3A1502)
Voltage Protection Ratings (VPRs)
Nominal System MCOV Voltage Protection Ratings (VPRs)
Catalog Number Voltage (VC) L-N L-L L-G
SPP40SP1120SN 120V 150V 700 —— SPP40SP2240PN 120V/240V 150V 700 1200 — SPP40SP3240DLG 240V 320V 2500 1200 SPP40SP3480DLG 480V 550V 3000 1800 SPP40SP3208WYG 208V 150V 1200 700 SPP40SP3480WYG 480V 320V 2500 1200
0213 BU-SB13071 Page 2 of 3 Data Sheet 10033
Loading...