Bussmann SPH50SP1120SN, SPH50SP1240SN, SPH50SP1347SN, SPH50SP2120SNG, SPH50SP2240SNG Data Sheet

...
URGEPROTECTIONMADESIMPLE™ FORCOMMERCIAL
2-1/16” 2-1/16”
1-11/16”
1-11/16”
4-1/8”
3-3/16”
4-1/16”
3-3/8”
7/8”
1-1/16” Dia.
S
S
POD™ HEAVY DUTY SPD
URGE
UL 1449 3rdEdition Listed Loadside and Lineside Protection
FOR
Description
The Cooper Bussmann SurgePOD™ HEAVY DUTY is a Type 1 UL Listed 1449 3rdEdition surge protective device suitable for installation on both the loadside or lineside of the service entrance overcurrent protective device.
Available in voltage and system specific versions to match electrical system and equipment requirements. The SurgePOD HEAVY DUTY delivers optimum surge protection using advanced patent pending SurgePOD™ module featuring thermal disconnect technology that eliminates the need for additional overcurrent protection.
Parallel connection to the electrical system permits the SurgePOD HEAVY DUTY SPD to be installed on any ampacity panel.
• Type 1 UL 1449 3rdEdition Listed SPDs are easily selected and installed on the loadside or lineside of the service entrance overcurrent protective device
• Patented Cooper Bussmann SurgePOD module technology eliminates the need for additional fusing
• Voltage specific models precisely match and protect electrical systems and equipment up to 600Vac
• Compact UV resistant NEMA 4X for indoor or outdoor applications
easyID™ LED status indicator provides surge protection status at a glance
NDUSTRIALAPPLICATIONS
& I
SPH50SP1120SN SPH50SP1240SN SPH50SP1347SN SPH50SP2120SNG SPH50SP2240SNG SPH50SP2347SNG SPH50SP2240PN
NEMA 4X Rated Heavy Duty
Type 1 UL Listed SPD
easyID™ LED
Status Indicator
SPH50SP2480PN SPH50SP3240PNG SPH50SP3480PNG SPH50SP3240DLG SPH50SP3480DLG SPH50SP4240HLG SPH50SP4480HLG
SPD Type 2
SPH50SP3208WYG SPH50SP3480WYG SPH50SP3600WYG SPH50SP4208WYNG SPH50SP4480WYNG SPH50SP4600WYNG
Dimensions - in
0213 BU-SB13145 Page 1 of 4 Data Sheet 2163
Type 1 SPD Part Number System
SPH = Product Series
Surge Protection Heavy Duty
Surge Rating
50S = 50kA max discharge current
No of Wires/Poles
P1 = 1 P2 = 2 P3 = 3 P4 = 4
Rated System Voltage
120, 208, 240, 347, 480, 600Vac
System
SN = Single-Phase 2 Wire, 2 Connection Points SNG = Single-Phase 2 Wire + G, 3 Connection Points PN = Split-Phase 3 Wire , 3 Connection Points PNG = Split-Phase 3 Wire + G, 4 Connection Points DLG = Three-Phase Delta 3 Wire + G, 4 Connection Points HLG = Three-Phase Highleg Delta 4 Wire + G, 5 Connection Points WYG = Three-Phase Wye 3 Wire, 4 Connection Points WYNG = Three-Phase Wye 3 Wire + G, 5 Connection Points
SPH 50S PX XXX XXX
SurgePOD™ HEAVY DUTY Technical Information
Nominal Max. Continuous
System Operating AC Connection
Catalog Number Voltage Voltage (MCOV) (VC) System Type Points
SPH50SP1120SN 120V 150V Single-Phase 2 Wire 2 SPH50SP1240SN 240V 320V Single-Phase 2 Wire 2 SPH50SP1347SN 347V 420V Single-Phase 2 Wire 2 SPH50SP2120SNG 120V 150V Single-Phase 2 Wire + G 3 SPH50SP2240SNG 240V 320V Single-Phase 2 Wire + G 3 SPH50SP2347SNG 347V 420V Single-Phase 2 Wire + G 3 SPH50SP2240PN 120/240V 150V Split-Phase 3 Wire 3 SPH50SP2480PN 240/480V 320V Split-Phase 3 Wire 3 SPH50SP3240PNG 120/240V 150V Split-Phase 3 Wire + G 4 SPH50SP3480PNG 240/480V 320V Split-Phase 3 Wire + G 4 SPH50SP3240DLG 240V 320V Three-Phase Delta 3 Wire + G 4 SPH50SP3480DLG 480V 550V Three-Phase Delta 3 Wire + G 4 SPH50SP4240HLG 120/240V 150/320V Three-Phase Highleg Delta 4 Wire + G 5 SPH50SP4480HLG 240/480V 320/550V Three-Phase Highleg Delta 4 Wire + G 5 SPH50SP3208WYG 208V 150V Three-Phase Wye 3 Wire + G 4 SPH50SP3480WYG 480V 320V Three-Phase Wye 3 Wire + G 4 SPH50SP3600WYG
600V 420V Three-Phase Wye 3 Wire + G 4 SPH50SP4208WYNG 208Y/120V 150V Three-Phase Wye 4 Wire + G 5 SPH50SP4480WYNG 480Y/277V 320V Three-Phase Wye 4 Wire + G 5 SPH50SP4600WYNG
† 600V Wye versions are not CSA Certified.
600Y/347V 420V Three-Phase Wye 4 Wire + G 5
SurgePOD™ HEAVY DUTY Technical Information
Specifications (for all SurgePOD HD units) Values
Short Circuit Current Rating (SCCR) 200kA Nominal Discharge Current (8x20µs) I Max. Discharge Current (8x20µs) I Response Time t
A
max
n
20kA 50kA
<25ns Frequency 50/60Hz Operating State/Fault Indication Bi-Color LED - Green (good) / Red (replace) Conductor Length / Guage 18 inches, 10 AWG Stranded Tinned Copper Mounting Chase Nipple / Bracket* Enclosure / Flammability Ratings NEMA 4X - UL 94-5VA Degree of Protection (Installed State) IP20 (finger-safe) SPD Install Location Indoor/Outdoor Circuit Location Lineside or Loadside of service entrance overcurrent protective device Standard UL 1449 3rdEdition Type 1 Listed SPD Agency Information cULus, CSA**, RoHS Compliant Product Warranty 5 Years*** Operating Temperature -40˚C to +85˚C Maximum Operating Altitude 16,000FT
* Customer-supplied bracket.
** 600V Wye versions not CSA Certified.
*** See Cooper Bussmann SPD Limited Warranty Statement (3A1502)