UL 1449 3rdEdition Listed Loadside and Lineside Protection
FOR
Description
The Cooper Bussmann SurgePOD™ HEAVY DUTY is a Type 1
UL Listed 1449 3rdEdition surge protective device suitable for
installation on both the loadside or lineside of the service
entrance overcurrent protective device.
Available in voltage and system specific versions to match
electrical system and equipment requirements. The SurgePOD
HEAVY DUTY delivers optimum surge protection using
advanced patent pending SurgePOD™ module featuring
thermal disconnect technology that eliminates the need for
additional overcurrent protection.
Parallel connection to the electrical system permits the
SurgePOD HEAVY DUTY SPD to be installed on any ampacity
panel.
• Type 1 UL 1449 3rdEdition Listed SPDs are easily selected
and installed on the loadside or lineside of the service
entrance overcurrent protective device
• Patented Cooper Bussmann SurgePOD module technology
eliminates the need for additional fusing
• Voltage specific models precisely match and protect
electrical systems and equipment up to 600Vac
• Compact UV resistant NEMA 4X for indoor or outdoor
applications
• easyID™ LED status indicator provides surge protection
status at a glance
The easyID™ LED status indicator will illuminate when the unit is
properly installed and the system or equipment being protected is
energized. The following LED color/status indicates:
†
600Y/347V420V1500250025001500
Mounting
SurgePOD HEAVY DUTY is a panel mount device. It may also
be mounted using a customer supplied bracket or directly
onto a female threaded conduit fitting.
GREEN LED = Good
The circuit is energized and protected.
RED LED = Replace
The circuit is energized and unprotected.
The unit needs replacing.
LED is Out / Unlit:
•The circuit is most likely deenergized
• The unit’s leads are disconnected
• The unit is damaged
Authorized personnel should follow all prescribed lockout/tagout and safety procedures in troubleshooting
the cause for the above conditions. Opening SurgePOD HEAVY DUTY enclosure will void UL listing and warranty.
0213 BU-SB13145Page 3 of 4Data Sheet 2163
Wiring Connections
Black
Black
White
L1 (Black)
L2 (Black)
N (White)
Black
White
L (Black)
N (White)
GND (Green)
Black
Green
White
Black
Black
Green
White
L1 (Black)
L2 (Black)
N (White)
GND (Green)
Single-Phase
Wye + Ground
L
(Black)
N (White)
120, 240, 347V
(
L-
N)
2 Wire
Must be installed within 10 feet (3m) of a bonded
ne
ut
r
al-gro
und c
o
nnec
tion per IEE
E C62.41-1991
Two-Pole with Neutral
120V (L-N) / 240V (L1-L2),
240V (L-N) / 480V (L1-L2)
Single Phase (Split) Center Tap
For installations at or less than 10 feet (3m)
from the transforme
r.
Single-Phase + Ground
SPH50SP1120SN,
SPH50SP1240SN
SPH50SP1347SN
SPH50SP2240PN,
SPH50SP2480PN
L1 (Black)
L2 (Black)
L3 (Black)
,
GND (Green)
208, 480, 600V (L-L)
Black
Black
Black
Green
SPH50SP3208WYG,
SPH50SP3480WYG,
SPH50SP3600WYG
3 Wire Wye + Ground
Wye with Neutral + Ground
L1 (Black)
L2 (Black)
Black
Black
Black
N (White)
White
Green
L3 (Black)
GND (Green)
120V (L-N) / 208V (L-L),
127V (L-N) / 220V (L-L),
SPH50SP4208WYNG,
SPH50SP4480WYNG,
SPH50SP4600WYNG
277V (L-N) / 480V (L-L),
347V (L-N) / 600V (L-L)
4 Wire Wye + Ground
Delta + Ground
L1 (Black)
Black
Black
Black
Green
Black
Black
White
Green
Orange
SPH50SP3240DLG,
SPH50SP3480DLG
SPH50SP4240HLG,
SPH50SP4480HLG
120
, 240, 347V (L-N)
2 Wire + Ground
For installation when located greater tha
of a bonded neutral-ground connection.
For installation when located greater than 10 feet (3m) of a
bonded neutral-ground connection.
(3m)
SPH50SP2120SNG,
SPH50SP2240S
NG,
SPH50SP2347SNG
SPH50SP3240PNG,
SPH50SP3480PNG
L2 (Black)
L3 (Black)
GND (Green)
240, 480V (L-L)
3 Wire Delta + Ground
Highleg Delta
L2 (Orange)
Highleg
L3 (Black)
N (White)
L1 (Black)
GND (Green)
120V (L1 / L3-N) / 240V (L-L),
240V (L1 / L3-N) / 480V (L-L)
4 Wire Highleg Delta + Ground
The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by
definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design
applications. Cooper Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any
products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been
selected, it should be tested by the user in all possible applications.
0213 BU-SB13145Page 4 of 4Data Sheet 2163
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.