Catalog Numbers
FRS-R-⁄Ω¡º FRS-R-1°Ω¡º FRS-R-8
FRS-R-⁄Ω• FRS-R-2 FRS-R-9
FRS-R-⁄fiΩ¡ºº FRS-R-2⁄Ω¢ FRS-R-10
FRS-R-¤Ω¡º FRS-R-2⁄Ω™ FRS-R-12
FRS-R-⁄Ω¢ FRS-R-2°Ω¡º FRS-R-15
FRS-R-‹Ω¡º FRS-R-3 FRS-R-17⁄Ω™
FRS-R-›Ω¡º FRS-R-3¤Ω¡º FRS-R-20
FRS-R-⁄Ω™ FRS-R-3⁄Ω™ FRS-R-25
FRS-R-flꭧ FRS-R-4 FRS-R-30
FRS-R-°Ω¡º FRS-R-4⁄Ω™ FRS-R-35
FRS-R-1 FRS-R-5 FRS-R-40
FRS-R-1⁄Ω• FRS-R-5flΩ¡º FRS-R-45
FRS-R-1⁄Ω¢ FRS-R-6 FRS-R-50
FRS-R-1›Ω¡º FRS-R-6⁄Ω¢ FRS-R-60
FRS-R-1⁄Ω™ FRS-R-7 —
FRS-R-1flΩ¡º FRS-R-7⁄Ω™ —
Fuse Reducers For Class R Fuses
Desired Catalog Number
Equipment Fuse (Case) (Pairs)
Fuse Clips Size 600V
60A 30A No. 663-R
100A
30A No. 216-R
60A No. 616-R
200A 60A No. 626-R
Dimensional Data
Carton Quantity and Weight
Ampere Carton
Weight*
Ratings Qty. Lbs. Kg.
⁄Ω¡º–15 10 0.40 0.181
17.5–30 10 0.50 0.277
35-60 10 3.10 1.406
*Weight per carton.
General Information:
• Provides motor overload, ground fault and short-circuit pro-
tection. When used in circuits subject to surge currents such
as those caused by motors, transformers and other inductive
components, these fuses can be sized close to full-load
amperes to give maximum overcurrent protection.
• Permits the use of smaller and less costly switches. The time-
delay feature makes it possible to use fuse ampere ratings
which are much smaller than those of non-time-delay fuses.
Considerable cost saving occurs by permitting the use of
smaller size switches, panels and fuses themselves.
• Provides a higher degree of short-circuit protection (greater
current-limitation) in circuits in which surge currents or temporary overloads occur.
• Helps protect motors against burnout from overloads.
• Gives motor running back-up protection to motors without
extra costs.
• Helps protect motors against burnout from single phasing on
three phase systems.
• Simplifies and improves blackout prevention (selective
coordination).
• Dual-element fuses can be applied in circuits subject to tem-
porary motor overloads and surge currents to provide both
high-performance, short-circuit and overload protection.
• The overload element provides protection against low level
overcurrent of overloads and will hold an overload which is
five times greater than the ampere rating of the fuse for a
minimum of ten seconds.
Catalog Symbol: FRS-R
Dual-Element, Time-Delay – 10 second (minimum) at 500%
rated current
Current-Limiting
Ampere Rating: ⁄Ω¡º to 60A
Voltage Rating: 600Vac (or less)
Interrupting Rating: 200,000A RMS Sym.
dc Ratings (20,000AIC @ 250Vdc)
Agency Information:
UL Listed, Std. 248-12, Class RK5, Guide JDDZ, File E4273
CSA Certified, C22.2 No. 248.12, Class 1422-02, File 53787
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 314-527-1270 for more information.
Recommended fuseblocks for
Class R 600V fuses
See Data Sheet: 1111