CH Series Modular Fuse Holder Specifications
Catalog Numbers
Max No. of
Without With* Voltage 17.5mm
Indication Indication Size & Current IEC UL Phase Configuration Modules Wire Range Maximum Torque
CH081D CH081DI • 1-pole 1 1-16mm
2
(18-8 AWG) 2.5 N•m (22LB-In)
CH081DNX - • 1 Neutral Pole 1
CH081DNS CH081DNSI • 1-pole + Neutral 1 1-10mm2(18-8 AWG) 2.0 N•m (17.5LB-In)
CH081DN CH081DNI CH08 IEC • 1-pole + Neutral 2
CH082D CH082DI 8x32 400Vac • 2-pole 2
CH083D CH083DI 25A • 3-pole 3 1-16mm
2
(18-8 AWG) 2.5 N•m (22LB-In)
CH083DNS CH083DNSI • 3-pole + Neutral 3
CH083DN CH083DNI • 3-pole + Neutral 4
CH084D CH084DI • 4-pole 4
CHM1DU CHM1DIU • * 1-pole 1
CHM2DU CHM2DIU UL • * 2-pole 2
CHM3DU CHM3DIU CHM 600V/30A; • * 3-pole 3
CHM4DU CHM4DIU 10X38 IEC • * 4-pole 4
CHM1DNU CHM1DNIU and 690V/32A • * 1-pole + Neutral 2
CHM3DNU CHM3DNIU Midget • * 3-pole + Neutral 4 1-21mm
2
(18-4 AWG) 3.4 N•m (30LB-In)
UL 48Vdc/30A;
– CHM1DI-48U IEC • * 1-pole 1
48Vdc/32A
CHM1DNXU – IEC 690V32A • 1-pole + Neutral 2
CHPV1U CHPV1IU
CHPV
UL & IEC; • ††† 1-pole 1
CHPV2U CHPV2IU 1000Vdc/30A • ††† 2-pole 2
CHCC1DU CHCC1DIU ** 1-pole 1
CHCC2DU CHCC2DIU CHCC
UL
** 2-pole 2 1-21mm
2
(18-4 AWG) 3.4 N•m (30LB-In)
CHCC3DU CHCC3DIU Class CC
600V/30A
** 3-pole 3
CHCC1DI-48U – UL 48Vdc/30A ** 1-pole 1
CH141D CH141DI • 1-pole 1.5
CH141DMS - UL • 1-pole + Microswitch 1.5
CH141DNX - 600Vac/dc • 1 Neutral Pole 1.5
CH141DN CH141DNI 40A • 1-pole + Neutral 3
CH142D CH142DI CH14 (5 Watt) • † 2-pole 3 2.5-16mm
2
(14-6 AWG) 3.0 N•m (26LB-In)
CH143D CH143DI 14x51 IEC • † 3-pole 4.5
CH143DMS - 690Vac, • 3-pole + Microswitch 4.5
CH143DN CH143DNI 50A • 3-pole + Neutral 6
CH143DNMS - • 3-pole + Neutral + Microswitch 6
CH144D CH144DI • 4-pole 6
CH221D Not • † 1-pole 2
CH221DMS Available • 1-pole + Microswitch 2
CH221DNX with UL • 1 Neutral Pole 2
CH221DN local 600Vac/dc, • 1-pole + Neutral 4
CH222D neon CH22 100A • † 2-pole 4 2.5-50mm
2
(14-1 AWG) 4.0 N•m (35LB-In)
CH223D indication 22x58 (9.5 Watt) • † 3-pole 6
CH223DMS (remote IEC • 3-pole + Microswitch 6
CH223DN microswitch 690Vac, • † 3-pole + Neutral 8
CH223DNMS only) 125A • 3-pole + Neutral + Microswitch 8
CH224D • 4-pole 8
Class J Neon
easyID™ Indication Indication
CH30J1 CH30J1I CH30J UL/CSA †† 1-pole — 1-50mm
2
(18-1 AWG) 1-8 AWG 4.0 N•m (35LB-In)
CH30J2 CH30J2I 30A 600Vac †† 2-pole —
10-18 AWG 2.7N•m (24LB-IN)
CH30J3 CH30J3I Class J †† 3-pole —
CH60J1 CH60J1I CH60J UL/CSA †† 1-pole — 1-50mm
2
(18-1 AWG) 1-8 AWG 4.0 N•m (35LB-In)
CH60J2 CH60J2I 60A 600Vac †† 2-pole — 10-18 AWG 2.7N•m (24LB-In)
CH60J3 CH60J3I Class J †† 3-pole —
† UL Recognized (cURus) †† UL LIsted (cULus) ††† UL Recognized, Standard 4248-18, CSA
For further details see Data Sheets 2053 (CH08, CHM, CHCC, CH14 AND CH22) and 2144 (CHJ Class J)
*90V miminum required for illumination
***12V mininum required for illumination
8x32 IEC 14x51 IEC 22x58 IEC
PV UL IEC
Class J 30A
* UL Recognized, CSA
** UL Listed, CSA