![](/html/8c/8c35/8c3512d298c91fc05f80a229b7e415c264d5eb98bb39e68681797e305578fecc/bg1.png)
Surge Protection Made Simple™ for Photovoltaic Applications
Combined Lightning Current & Surge Arrester for PV Systems up to 1000Vdc
Description
The Cooper Bussmann combined lightning current and surge
arrester (SPD Class I according to IEC 61643-1) is for use in
photovoltaic power supply systems.
• Prewired combined lightning current and surge arrester for
use in photovoltaic generator circuits
• For use in photovoltaic installations up to 1000V U
• High lightning current discharge capacity using spark gap
technology
• Maximum system availability due to spark gap technol
with DC current extinction
Dimensions - mm
CPV
ogy
BSPS31000PV
Module Circuit Diagrams
BSPS31000PV
0511 BU-SB11505 Page 1 of 2 Data Sheet 2148
![](/html/8c/8c35/8c3512d298c91fc05f80a229b7e415c264d5eb98bb39e68681797e305578fecc/bg2.png)
Ordering Information
Max. PV System Voltage 1000Vdc
Catalog Number: BSPS31000PV
Specifications
SPD Classification according to EN 61643-11 Type 1
SPD Classification according to IEC 61643-1 Class I
Max. PV voltage [U
Max. Continuous operating DC voltage [U
Min. Continuous operating DC voltage [U
Follow current extinguishing capability DC [IfiDC] 100A
Nominal discharge current (8/20 µs) [In] 100kA
Lightning impulse current (10/350 µs) [L+/L- -> PE] [I
Specific energy [L+/L- -> PE] [W/R] 625.00 kJ/ohms
Lightning impulse current (10/350 µs) [L+ -> L-] [I
Specific energy [L+ -> L-] [W/R] 156.25 kJ/ohms
Voltage protection level [L+ -> L-] [Up] _< 3.3kV
Voltage protection level [(L+/L-) -> PE] [Up] _< 4kV
Operating current [IINDC] _< 5mA
Response time [L+ -> L-] [tA] _< 20 ns
Protective conductor current [IPE] _< 1µA
Operating temperature range [Tu] -40°C to +60°C
Number of ports 1
Cross-sectional area (min.) 10mm2/6AWG solid/flexible
Cross-sectional area (max.) 50mm2/2AWG stranded/ 35mm2/1AWG flexible
Mounting 35mm DIN rail per EN 60715
Enclosure material Thermoplastic, UL 94V0
Place of installation Indoor
Degree of protection IP-20
Capacity 8 Mods., DIN 4
Product Warranty Five Years*
* See Cooper Bussmann document 3A1502 on the web at www.cooperbussmann.com.
] of the PV generator 1000V
CPV
DC] 1000V
max
DC] 100V
min
] 50kA
imp
] 25kA
imp
The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition
uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Cooper
Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products.
Cooper Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulleting. Once a product has been selected, it should
be tested by the user in all possible applications.
0511 BU-SB11505 Page 2 of 2 Data Sheet 2148