design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.
Ordering Information
System Voltage/Poles 230V/2 230V/2
Max. Continuous operating AC voltage (MCOV) [UC] 255V 255V
Catalog Numbers: Without Remote Signaling BSPS2255TN BSPS2255TT
With Remote Signaling BSPS2255TNR BSPS2255TTR
Replacement Modules (Spark Gap technology):
(2X) BPS255IEC (1X) BPS255IEC
- - (1X) BPS50NPEIEC*
Specifications
Specific energy [L+N-PE] [W/R] 625.00 kJ/ohms - Lightning impulse current (10/350 µs) [L, N-PE] [I
imp
] 25kA 25/50kA Is[L-N]/[N-PE]
Specific energy [L,N-PE] [W/R] 156.25 kJ/ohms
156.25kJ/ohms/
625.00 kJ/ohms
Voltage protection level [L-PE]/[N-PE] [UP]<_ 1.5 kV/<_ 1.5 kV - Voltage protection level [L-N]/[N-PE] [UP]- -<_ 1.5kV/<_ 1.5kV
Follow current extinguishing capability AC [Ifi] 50kA rms - Follow current extinguishing capability [L-N]/[N-PE] [Ifi] - - 50kA rms/100A rms
Temporary overvoltage (TOV) [N-PE] [UT] - - 1200V/200 ms
SPD according to EN 61643-11/... IEC 61643-1 Type 1/Class I
Energy-coordinated protection effect with regard to the terminal equipment Type 1 + Type 2
Energy-coordinated protection effect with regard to the terminal equipment (<_ 5m) Type 1 + Type 2 + Type 3
Nominal AC voltage [UN] 230V
Lightning impulse current (10/350 µs) [L+N-PE] [I
total
] 50kA
Nominal discharge current (8/20 µs) [In] 25/50kA
Follow current limitation/Selectivity no tripping of a 20A gL/gG fuse up to 50kA rms (prosp.)
Response time [tA] <_ 100 ns
Max. Backup fuse (L) up to IK<_ 50kA rms 315A gL/gG
Max. Backup fuse (L) for IK> 50kA rms 200A gL/gG
Max. Backup fuse (L-L´) 125A gL/gG
Temporary overvoltage (TOV) [L-N] [UT] 440V/5 sec.
TOV characteristics withstand
Operating temperature range (parallel connection) [TUP] -40°C to +80°C
Operating temperature range (series connection) [TUS] -40°C to +60°C
Operating temperature range [parallel]/[continuity] [TU] -40°C to +80°C/-40°C to +60°C
Operating state/fault indication green (good)/red (replace)
Number of ports 1
Cross-sectional area (L, L´, N, N´, PE, ) [min.] 10mm2solid/flexible
Cross-sectional area (L, N, PE) [max.] 50mm2/1AWG stranded-35mm2/2AWG flexible
Cross-sectional area (L´, N´, ) [max.] 35mm2/2AWG stranded-25mm2/4AWG flexible
For mounting on 35mm DIN Rail per EN 60715
Enclosure material Thermoplastic, UL 94V0
Location category Indoor
Degree of protection IP20
Capacity 4 mods., DIN 43880
Standards Information KEMA
Product Warranty Five Years**
Remote Contact Signaling
Remote Contact Signaling Type Changeover Contact
AC Switching Capacity (Volts/Amps) 250V/0.1A
DC Switching Capacity (Volts/Amps) 250V/0.1A; 125V/0.2A; 75V/0.5A
Conductor Ratings and Cross-Sectional Area for Remote Contact Signal Terminals 60/75°C Max. 1.5mm2/14AWG Solid/Flexible
Ordering Information Order from Catalog Numbers Above
* N-PE Surge arrester for location between neutral conductor and protective conductor
in TT systems.
** See Cooper Bussmann SPD Limited Warranty Statement (3A1502) for details at
www.cooperbussmann.com/surge.
Recommended Cooper Bussmann NH DIN Size Back Up Fuses
Size NH Fuse Part Number Size NH Fuse Part Number
00 125NHG00B (max L-L) 02 125NHG02B (max L-L)
0 125NHG0B (max L-L) 02 200NHG02B (max L Ik >50kA)
01 125NHG01B (max L-L) 2 315NHG2B (max L _<50kA)
1 200NHG1B (max L Ik >50kA) 03 315NHG03B (max L _<50kA)