Bussmann BSPM1275TN, BSPM1320TN, BSPM1385TN, BSPM1440TN, BSPM1600TN Data Sheet

...
0611 BU-SB11646 Page 1 of 2 Data Sheet 1166
Description
The Cooper Bussmann IEC Class II 275, 320, 385, 440 and 600 volt, one­pole, modular surge arresters feature local,
easy
ID™ visual indication and optional remote contact signaling. The unique module locking system fixes the protection module to the base part. Modules can be easily replaced without tools by simply depressing the release buttons. Integrated mechanical coding between the base and protection module ensures against installing an incorrect replacement module.
Class II single-pole surge arrester models are offered with MCOV ratings of 255, 275, 320, 385, 440 and 600 volts.
TN System Arresters
The features of these single-pole devices are for use as a single device or in combination with other devices.
TT System Arrester
Provides a current arresting means between neutral conductor and protective conductor in TT systems, this device helps ensure fulfilling the requirements for protection of personnel and equipment in “3+1” and “1+1” circuits.
Remote Signaling Contact
The three-pole terminal remote signaling contact versions have a floating changeover contact for use as a break or make contact, according to circuit concept.
Surge Protection Made Simple™for IEC Applications
IEC Class II Surge Arresters for 230-600 Volt, 1-Pole TN & TT Systems
BSPM1275TN(R) BSPM1320TN(R) BSPM1385TN(R) BSPM1440TN(R) BSPM1600TN(R)
BSPG1255NPE(R)
Shown with optional remote contact signaling
Module Circuit Diagrams -
Shown with optional remote contact signaling
Dimensions - mm
Remote Signal
Contact Available
Visual Status Indication
BSPM1275TN(R) BSPM1320TN(R) BSPM1385TN(R) BSPM1440TN(R) BSPM1600TN(R) BSPG1255NPE(R)
MOV
Thermal Disconnector
Gas Discharge Tube (single)
0611 BU-SB11646 Page 2 of 2 Data Sheet 1166
The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information con­tained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.
* N-PE Surge arrester for location between neutral conductor and protective conductor in TT systems.
** See Cooper Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.
Recommended Cooper Bussmann Back Up Fuses
DIN TT / TN System NH Fuse Part Numbers
Fuse Size 275, 320, 385, 440V 600V
00 125NHG00B 100NHG00B-690
0 125NHG0B 100NHG0B-690
01 125NHG01B - -
1 - - 100NHG1B-690
02 125NHG02B - -
2 - - 100NHG2B-690
Ordering Information
System Voltage/Poles 230V/1 230V/1 230V/1 400V/1 600V/1 230V/1* Max. Continuous operating AC voltage (MCOV) [UC] 275V 320V 385V 440V 600V 255V Catalog Numbers: Without Remote Signaling BSPM1275TN BSPM1320TN BSPM1385TN BSPM1440TN BSPM1600TN BSPG1255NPE (Base + Modules) With Remote Signaling BSPM1275TNR BSPM1320TNR BSPM1385TNR BSPM1440TNR BSPM1600TNR BSPG1255NPER Replacement Modules BPM275IEC BPM320IEC BPM385IEC BPM440IEC BPM600IEC BPG255NPE
Specifications
Line system type TN / TT TN / TT TN / TT TN TN TT Max. Continuous operating DC voltage [UC] 350V 420V 500V 585V 600V - ­Voltage protection level [UP]<_ 1.25kV <_ 1.5kV <_ 1.75kV <_ 2kV <_ 2.5kV <_ 1.5kV Voltage protection level at 5kA [UP]<_ 1kV <_ 1.2kV <_ 1.35kV <_ 1.7kV <_ 2kV - ­Max. mains-side overcurrent protection 125A gL/gG 125A gL/gG 125A gL/gG 125A gL/gG 100A gL-gG - ­Short-circuit withstand capability for max.
50kA
rms
25kA
rms
25kA
rms
25kA
rms
25kA rms - -
mains-side overcurrent protection Temporary overvoltage (TOV) [UT] 335V/5 sec. 335V/5 sec. 385V/5 sec. 580V/5 sec. 600V/5 sec. 1200V/200 ms Response time [tA]<_ 25 ns <_ 25 ns <_ 25 ns <_ 25 ns <_ 25 ns <_ 100 ns Follow current extinguishing capability [Ifi] - - - - - - - - - - 100A
rms
Lightning impulse current (10/350 µs) [I
imp
] - - - - - - - - - - 12kA Nominal discharge current (8/20 µs) [In] 20kA 20kA 20kA 20kA 15kA 20kA Max. Discharge current (8/20 µs) [I
max
] 40kA 40kA 40kA 40kA 30kA 40kA Standards Information KEMA KEMA, CSA KEMA, CSA KEMA, CSA KEMA KEMA Capacity 1 mod., DIN 43880 SPD according to EN 61643-11 Type 2 SPD according to IEC 61643-1 Class II TOV characteristics Withstand Operating temperature range [TU] -40°C to +80°C Operating state/fault indication Green (good) / Red (replace) Number of ports 1 Cross-sectional area (min.) 1.5mm2/14AWG solid/flexible Cross-sectional area (max.) 35mm2/2AWG stranded-25mm2/4AWG flexible Mounting 35mm DIN Rail per EN 60715 Enclosure material Thermoplastic, UL 94V0 Location category Indoor Degree of protection IP20 Product Warranty Five Years**
Remote Contact Signaling
Remote Contact Signaling Type Changeover Contact AC Switching Capacity (Volts/Amps) 250V/0.1A DC Switching Capacity (Volts/Amps) 250V/0.1A; 125V/0.2A; 75V/0.5A Conductor Ratings and Cross-Sectional Area for
60/75°C Max. 1.5mm
2
/14AWG Solid/Flexible
Remote Contact Signal Terminals Ordering Information Order from Catalog Numbers Above