Busch-Jaeger 2247-500, 2247 U-500, 2247 U-127-500 User manual

1473-1 -7913 Rev. 01 17.12.2012
Dimmer
2247 2247 U 2247 U
Operating Instructions
Busch-Dimmer®
-500
-500
-127-500
=== Ende der Li st e für Te xtm arke Cov er == =
Operating Instructions
Busch-Dimmer®
Operating Instructions | 1473-1-7913
— 2 —
Pos: 4 /#N eustr uk tur #/Onl ine- Dok umen ta tion ( +KN X) /In halt sver zei chni s ( --> F ür al le D ok ume nte < --)/I nhalts verz eichni s @ 19\mod_1320649044386_15.docx @ 109653 @ @ 1
Safety ....................................................................................................................................................................... 3
1
2 Intended use ............................................................................................................................................................ 3
3 Environment ............................................................................................................................................................. 3
4 Technical data .......................................................................................................................................................... 4
5 Setup and function ................................................................................................................................................... 4
5.1 Features of function and equipment ........................................................................................................ 4
5.2 Possible combinations ............................................................................................................................ 5
6 Reduction of the connection load (derating)............................................................................................................. 6
7 Installation and electrical connection ....................................................................................................................... 7
7.1 Requirements for the electrician ............................................................................................................. 7
7.2 Mounting ................................................................................................................................................. 8
7.3 Electrical connection ............................................................................................................................... 9
7.4 Inserting the glow lamp ......................................................................................................................... 10
8 Commissioning ...................................................................................................................................................... 10
9 Fault rectification .................................................................................................................................................... 11
=== Ende der Li st e für Te xtm arke TOC == =
Operating Instructions
Busch-Dimmer®
Safety
Operating Instructions | 1473-1-7913
— 3 —
Warning
Consider the protection of the environment!
device at the appropriate collecting depot.
Pos: 6 /#N eustr uk tur #/Onl ine- Dok umen ta tion ( +KN X) /Ü bersc hri fte n (--> Für alle Do ku ment e <--)/1. Ebene/S - T/Sicherhei t @ 18\mod_1302612791790_15.docx @ 103357 @ 1 @ 1

1 Safety

Pos: 7 /#N eustr uk tur #/Onl ine- Dok umen ta tion ( +KN X) /Si cher hei tshi nw eis e un d Hi nweis e ( --> F ür all e D o kume nte < --)/W arn hinw eis e/Sic herh eit - 127/230 V @ 23\mod_1337091457755_15.docx @ 209778 @ @ 1
Electric voltage!
Risk of death and fire due to electrical voltage of 127/230 V.
- Work on the 127/230 V supply system may only be performed by authorised electricians!
- Disconnect the mains power supply prior to installation and/or disassembly!
Pos: 8 /#N eustr uk tur #/Onl ine- Dok umen ta tion ( +KN X) /Ü bersc hri fte n (--> Für alle Do ku ment e <--)/1. Ebene/A - F/Bestimmu ngsge mäßer Gebra uch @ 18\mod_1302763321316_15.docx @ 103483 @ 1 @ 1

2 Intended use

Pos: 9 /#N eustr uk tur #/Online-Dokumentation (+KNX)/Bestimmungsgemäßer Gebrauch (--> Für alle Dokumente <--)/Busch-Dimmer/ Besti m mung sge mäß er G ebr auc h @ 23\ mod_1335350449857_15.docx @ 208763 @ @ 1
The device is to be used exclusively with the components that are supplied and licensed as described in chapter "Setup and function".
Pos: 10 /#N eustr u ktur #/O nlin e-Do ku ment ati on (+ KN X)/Ü ber sc hrift en ( --> F ür all e D ok ume nte < --)/1. E bene/U - Z/U mwel t @ 18\mod_1302614158967_15.docx @ 103383 @ 1 @ 1

3 Environment

Pos: 11 /#Ne ustr u ktur# /O nlin e-Dokumentation (+KNX)/Sicherheitshinweise und Hinweise (--> Für alle Dokumente <--)/Hinweise - Umwelt/Hinweis - Umwelt - Hinweis Elektrogeräte @ 18\mod_1302763973434_15.docx @ 103500 @ @ 1
Used electric and electronic devices must not be disposed of with domestic waste. – The device contains valuable raw materials which can be recycled. Therefore, dispose of the
Pos: 12 /#Neustr u ktur# /Onl ine- Dokumentation (+KNX)/Sicherheitshinweise und Hinweise (--> Für alle Dokumente <--)/Hinweise - Umwelt/Hinweis - Umwelt - Entsorgung Elektrogeräte @ 20\mod_1325760695972_15.docx @ 136583 @ @ 1
All packaging materials and devices bear the markings and test seals for proper disposal. Always dispose of the packaging material and electric devices and their components via the authorized collecting depots and disposal companies. The products meet the legal requirements, in particular the laws governing electronic and electrical devices and the REACH ordinance. (EU Directive 2002/96/EC WEEE and 2002/95/EC RoHS) (EU REACH ordinance and law for the implementation of the ordinance (EC) No.1907/2006)
Pos: 13 /#N eustr u ktur #/O nlin e-Dokumentation (+KNX)/Ste uer modul e - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1
Operating Instructions
Busch-Dimmer® Technical data
Operating Instructions | 1473-1-7913
— 4 —
General
Nominal voltage
2247 U-127-500
127 V AC ± 10%, 60 Hz
Nominal power (depending on the ambient temperature, a power loss of 20% in case of conventional transformers needs to be considered)
Minimum load
20 VA
Module width
3 MW (1 MW = 18 mm) applies only to Modular DIN Rail Component (MDRC)
Short-circuit protection
T 3.15 H
Overload protection
Temperature limiter
Total ambient temperature range
0 ...70 °C
Connected load
- Ambient temperature range
0 ... 35°C connected load 100%
- Ambient temperature range
35 ... 70°C reduced connected load (Derating)
Terminal 4
Nominal voltage
230 V AC ± 10%, 50/60 Hz
Nominal current
100 mA
Series circuit-breaker
0.5 A
Note
Pos: 14 /#N eustr u ktur #/O nlin e-Do ku ment ati on (+ KN X)/Ü ber sc hrift en ( --> F ür all e D ok ume nte < --)/1. E ben e/S - T/Technische Daten @ 11\mod_1279185386320_15.docx @ 83019 @ 1 @ 1

4 Technical data

Pos: 15 /#N eustr u ktur #/O nlin e-Dokumentation (+KNX)/Technische Daten/Dimmer/Technische Daten - 2247 @ 21\mod_1330930698905_15.docx @ 200327 @ @ 1
2247-500
2247-500 2247 U-127-500
230 V AC ± 10%, 50 Hz
500 W/VA 300 W/VA
Terminal 4 is intended for operation with mains isolating components, see Fig. 4
Pos: 16 /#N eustr u ktur #/O nlin e-Do ku ment ati on (+ KN X)/Ü ber sc hrift en ( --> F ür all e D ok ume nte < --)/1. Ebene/A - F/Aufbau und Funktion @ 11\mod_1279185435352_15.docx @ 83027 @ 1 @ 1

5 Setup and function

Pos: 17 /#N eustr u ktur #/O nlin e-Do ku ment ati on (+ KN X)/L ast art en/L ast art en Gl üh | H alo | NV- Hal o mit kon v-Trafo @ 23\mod_1335534706839_15.docx @ 208833 @ 1 @ 1
The device is intended for the activation of the following types of loads:
230 V incandescent lamps
230 V halogen lamps
Low-voltage halogen lamps with conventional transformers
Pos: 18 /#N eustr u ktur #/O nlin e-Do ku ment ati on (+ KN X)/Ü ber sc hrift en ( --> F ür all e D ok ume nte < --)/2. Ebene/A - F/Funktions- und Ausstattungsm erkmal e @ 23\mod_1336557630140_15.docx @ 209136 @ 2 @ 1

5.1 Features of function and equipment

Pos: 19 /#N eustr u ktur #/O nlin e-Dokumentation (+KNX)/Aufbau und Funktion/Dimmer/Funktionen - 2247_2250_2251 @ 21\mod_1330932578481_15.docx @ 200357 @ 2 @ 1
Rotary actuation
With two-way switch and soft-catch
Phase-angle
Adjustable minimum brightness
Illuminable with glow lamp (flush-mounted only)
Also suitable for two-way circuits