Busch-Jaeger 1099 UHK, 1099 UHKEA Operating Instructions Manual

Page 1
-1 -8396 1 1.03.2014
Pos: 2 /#Neus tr uktur #/O nli ne-D oku men tat ion ( +KN X) /Tit elbl ät ter/T e mper atur reg ler/ Tit elbl att 10 99 @ 37\ mod_1373543431500_15.docx @ 298504 @ @ 1
Temperature controllers
1099 UHK 1099 UHKEA
=== Ende der Lis te f ür T e xtmar ke C ov er == =
Page 2
Operating Instructions
Busch Temperaturregler
Operating Instructions | 1473-1-8396
— 2 —
Pos: 4 /#Neus tr uktur #/O nli ne-D oku men tat ion ( +KN X) /In halt sver zei chni s ( --> Für al le D ok ument e <--) /Inh altsver zeic hnis @ 19 \mod_1320649044386_15.docx @ 109653 @ @ 1
1
Safety ....................................................................................................................................................................... 3
2 Intended use ............................................................................................................................................................ 3
3 Environment ............................................................................................................................................................. 3
4 Setup and function ................................................................................................................................................... 4
4.1 Features of function and equipment ........................................................................................................ 4
5 Operation ................................................................................................................................................................. 4
6 Offset function .......................................................................................................................................................... 5
7 Technical data .......................................................................................................................................................... 5
8 Installation and electrical connection ....................................................................................................................... 6
8.1 Requirements for the electrician ............................................................................................................. 6
8.2 Mounting ................................................................................................................................................. 6
8.3 Electrical connection ............................................................................................................................... 8
9 Commissioning ........................................................................................................................................................ 9
=== Ende der Lis te f ür T e xtmar ke T OC ===
Page 3
Operating Instructions
Busch Temperaturregler Safety
Operating Instructions | 1473-1-8396
— 3 —
Pos: 6 /#Neus tr uktur #/O nli ne-D oku men tat ion ( +KN X) /Über sc hri fte n (--> Für alle Do kum ente < --)/1. Ebene/S - T/Sicherheit @ 18 \mod_1302612791790_15.docx @ 103357 @ 1 @ 1
1 Safety
Pos: 7 /#Neus tr uktur #/O nli ne-D oku men tat ion ( +KN X) /Si cher heit shi nw eis e un d Hi nweis e ( --> F ür all e D o kume nte < --)/W arnhi nwei se/ Sic herh eit - 230 V @ 18\mod_1302606816750_15.docx @ 103308 @ @ 1
Warning
Electric voltage!
Risk of death and fire due to electrical voltage of 230 V. – Work on the 230V supply system may only be performed by authorised electricians! – Disconnect the mains power supply prior to installation and/or disassembly!
Pos: 8 /#Neus tr uktur #/O nli ne-D oku men tat ion ( +KN X) /Über sc hri fte n (--> Für alle Do kum ente < --)/1. Ebene/A - F/Bestimmu ngsge mäßer G ebrauc h @ 18\mod_1302763321316_15.docx @ 103483 @ 1 @ 1
2 Intended use
Pos: 9 /#Neus tr uktur #/O nli ne-Dokumentation (+KNX)/Bestimmungsgemäßer Gebrauch (--> Für alle Dokumente <--)/Busch-Dimmer/B esti mmung sg em äßer Gebr a uch @ 2 3\mod_1335350449857_15.docx @ 208763 @ @ 1
The device is to be used exclusively with the components that are supplied and licensed as described in chapter "Setup and function".
Pos: 10 /#Ne ustr u ktur# /O nlin e-Do kume ntat ion (+ KN X)/Üb ers chr ift en ( --> Für all e D oku ment e <--) /1. Eb ene/U - Z/U mwel t @ 18\mod_1302614158967_15.docx @ 103383 @ 1 @ 1
3 Environment
Pos: 11 /#Ne ustr u ktur# /O nlin e-Dokumentation (+KNX)/Sicherheitshinweise und Hinweise (--> Für alle Dokumente <--)/Hinweise - Umwelt/Hinweis - Umwelt - Hinweis Elektrogeräte @ 18\mod_1302763973434_15.docx @ 103500 @ @ 1
Consider the protection of the environment!
Used electric and electronic devices must not be disposed of with domestic waste. – The device contains valuable raw materials which can be recycled. Therefore, dispose of the
device at the appropriate collecting depot.
Pos: 12 /#Ne ustr u ktur# /O nlin e-Dokumentation (+KNX)/Sicherheitshinweise und Hinweise (--> Für alle Dokumente <--)/Hinweise - Umwelt/Hinweis - Umwelt - Entsorgung Elektrogeräte @ 20\mod_1325760695972_15.docx @ 136583 @ @ 1
All packaging materials and devices bear the markings and test seals for proper disposal. Always dispose of the packaging material and electric devices and their components via the authorized collecting depots and disposal companies. The products meet the legal requirements, in particular the laws governing electronic and electrical devices and the REACH ordinance. (EU Directive 2002/96/EC WEEE and 2002/95/EC RoHS) (EU REACH ordinance and law for the implementation of the ordinance (EC) No.1907/2006)
Pos: 13 /#Ne ustr u ktur# /O nlin e-Dokumentation (+ KN X)/S teuer m odul e - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1
Page 4
Operating Instructions
Busch Temperaturregler
Setup and function
Operating Instructions | 1473-1-8396
— 4 —
Pos: 14 /#Ne ustr u ktur# /O nlin e-Do kume ntat ion (+ KN X)/Üb ers chr ift en ( --> Für all e D oku ment e <--)/1. Ebene/A - F/Aufbau und Funktion @ 11\mod_1279185435352_15.docx @ 83027 @ 1 @ 1
4 Setup and function
Pos: 15 /#Ne ustr u ktur# /O nlin e-Dokumentation (+KNX)/Aufbau und Funktion/Temperaturregler/Verwendung 1099 @ 37\mod_1373543224390_15.docx @ 298487 @ @ 1
The temperature controller is used to control the temperature in closed rooms.
Application only for de-energized closed actuating drives.
Pos: 16 /#Ne ustr u ktur# /O nlin e-Do kume ntat ion (+ KN X)/Üb ers chr ift en ( --> Für al l e Do ku ment e <--)/2. Ebene/A - F/Funktions- und Ausstattungs merk male @ 23 \mod_1336557630140_15.docx @ 209136 @ 2 @ 1
4.1 Features of function and equipment
Pos: 17 /#Ne ustr u ktur# /O nlin e-Dokumentation (+KNX)/Aufbau und Funktion/Temperaturregler/Funktionen 1099 @ 37\mod_1373543826093_15.docx @ 298519 @ @ 1
1099 UHKEA
1099 UHK
With manual switch for switchover between cooling/OFF/heating
With external input for switchover between heating and cooling.
Pos: 18 /#Ne ustr u ktur# /O nlin e-Do kume ntat ion (+ KN X)/Üb ers chr ift en ( --> Für all e D oku ment e <--)/1. Ebene/A - F/Bedi enu ng @ 11\ mod_1279185541649_15.docx @ 83043 @ 1 @ 1
5 Operation
Pos: 19 /#Ne ustr u ktur# /O nlin e-Dokumentation (+KNX)/Bedi enu ng/T emp erat urreg ler /B edien ung - 1099 @ 37\mod_1373544541890_15.docx @ 298567 @ @ 1 Pos: 21 /#Ne ustr u ktur# /O nlin e-Do kume ntat ion (+ KN X)/B edi enu ng/T emp erat urr egler /B edi enu ng - 1099 @ 37\mod_1373544541890_1.docx @ 298566 @ 1 @ 4
1099 UHKEA
1099 UHK
Fig. 1: Operation
No.
Function
A LED red Operating mode "Heating"
LED blue Operating mode "Cooling"
B
Sliding switch at 1099 UHKEA for selecting function B
C
Control knob for selecting the desired room temperature
Pos: 20 /#Ne ustr u ktur# /O nlin e-Do kume ntat ion (+ KN X)/S teuer m odul e - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1
Page 5
Operating Instructions
Busch Temperaturregler
Offset function
Operating Instructions | 1473-1-8396
— 5 —
Pos: 21 /#Ne ustr u ktur# /O nlin e-Dokumentation (+KNX)/Überschriften (--> Für al le D o kume nte < --)/1 . Eben e/M - O/ Offse t-Funktionen @ 37\mod_1373544905078_15.docx @ 298599 @ 2 @ 1
6 Offset function
Pos: 22 /#Ne ustr u ktur# /O nlin e-Do kume ntat ion (+ KN X)/B edi enu ng/T emp erat urr egler /E ins tel lung en O ff-S et - 1099 @ 37\mo d_1373544852375_15.docx @ 298583 @ @ 1
Fig. 2: Offset function
Reaching the selected room temperature strongly depends on the ambient conditions such as heating/cooling system capacity (5 K/h min.), room size, ambient temperature, insulation etc.
That is why the values in the scale are merely guide values. To obtain a setting that is as accurate as possible, the adjusting knob (1) can be offset in 4 stages by a total of +/-6°C.
To do so, pull off the control knob and cut off the position lug (2) on its underside using a suitable tool.
Then shift the control knob by the desired correction temperature in relation to the vertical and put it back on.
Pos: 23 /#Ne ustr u ktur# /O nlin e-Do kume ntat ion (+ KN X)/Üb ers chr ift en ( --> Für all e Dokumente <--)/1. Ebene/S - T/Technische Daten @ 11\mod_1279185386320_15.docx @ 83019 @ 2 @ 1
7 Technical data
Pos: 24 /#Ne ustr u ktur# /O nlin e-Dokumentation (+KNX)/Technische Daten/Temperaturregler/Technische Daten 1099 @ 37\mod_1373544943578_15.docx @ 298615 @ @ 1
General
Nominal voltage
230 V ~ ±10%, 50 / 60 Hz
Switching capacity (inductive) heating
10 (4) A, 230 V ~
Switching capacity (inductive) cooling
5 (2) A, 230 V ~
Connection
1.5 mm² … 2.5 mm²
Temperature adjustment range
~ 5 to 30°C (1 = 5°C | 2 = 10°C | 3 = 15°C | 4 = 20°C | 5 = 25°C | 6 = 30°C)
Switching temperature difference *
Approx. +/- 0.5 K
Protection type
IP 20, (EN 60529)
Power loss (Relay off)
0.5 W
Switch contact (independent normally open
contact)
2
Mode of operation (DIN EN 60730-1)
1 B
Degree of contamination (DIN EN 60730-1)
2
Rated surge voltage (DIN EN 60730-1)
4000 V
* Typical control operation can not always be attained for cooling areas close to the floor. When the device
heats up due to high current loads, the set value should be checked especially in cooling operating mode and, if necessary, the set-point temperature should be raised.
Pos: 25 /#Ne ustr u ktur# /O nlin e-Do kume ntat ion (+ KN X)/S teuer m odul e - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1
Page 6
Operating Instructions
Busch Temperaturregler
Installation and electrical
connection
Operating Instructions | 1473-1-8396
— 6 —
Pos: 26 /#Ne ustr u ktur# /O nlin e-Do kume ntat ion (+ KN X)/Üb ers chr ift en ( --> Für all e D oku ment e <--) /1. Eb ene/M - O/M ont age und el ektris cher A nschl uss @ 23\ mod_1336477157864_15.docx @ 209033 @ 3 @ 1
8 Installation and electrical connection
Pos: 27 /#Ne ustr u ktur# /O nlin e-Dokumentation (+KNX)/Sicherheitshinweise und Hinweise (--> Für alle Dokumente <--)/Warnhinw eise /Sic herh eit - N ied ers pann ung s- und 230 V-Leitung en @ 23 \mod_1336558868201_15.docx @ 209164 @ @ 1
Warning
Electric voltage!
Risk of death due to electrical voltage of 230 V during short-circuit in the low-voltage line.
– Low-voltage and 230 V lines must not be installed together in a flush-mounted socket!
Pos: 28 /#Ne ustr u ktur# /O nlin e-Dokumentation (+KNX)/Sicherheitshinweise und Hinweise (--> Für alle Dokumente <--)/Warnhinw eise /Sic herh eit - F ac hken nt niss e @ 23\mod_1336559183027_15.docx @ 209179 @ 2 @ 1
8.1 Requirements for the electrician
Warning
Electric voltage!
Install the device only if you have the necessary electrical engineering knowledge and experience.
Incorrect installation endangers your life and that of the user of the electrical system.
Incorrect installation can cause serious damage to property, e.g. due to fire.
The minimum necessary expert knowledge and requirements for the installation are as follows:
Apply the "five safety rules" (DIN VDE 0105, EN 50110):
1. Disconnect from power;
2. Secure against being re-connected;
3. Ensure there is no voltage;
4. Connect to earth and short-circuit;
5. Cover or barricade adjacent live parts.
Use suitable personal protective clothing.
Use only suitable tools and measuring devices.
Check the supply network type (TN system, IT system, TT system) to secure the following
power supply conditions (classic connection to ground, protective earthing, necessary
additional measures, etc.).
Pos: 29 /#Ne ustr u ktur# /Onl in e-Do kume ntati on (+ KNX )/Üb ersc hr ift en ( --> Für all e D oku ment e <--) /2. Eb ene/M - O/M ontag e @ 18\mod_1302615960458_15.docx @ 103424 @ 2 @ 1
8.2 Mounting
Pos: 30 /#Ne ustr u ktur# /O nlin e-Dokumentation (+KNX)/Sicherheitshinweise und Hinweise (--> Für alle Dokumente <--)/Warnhinweis e/Si ch erhei t - 23 0 V @ 18\mod_1302606816750_15.docx @ 103308 @ @ 1
Warning
Electric voltage!
Risk of death and fire due to electrical voltage of 230 V. – Work on the 230V supply system may only be performed by authorised electricians! – Disconnect the mains power supply prior to installation and/or disassembly!
Pos: 31 /#Ne ustr u ktur# /O nlin e-Do kume ntat ion (+ KN X)/S teuer m odul e - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1
Page 7
Operating Instructions
Busch Temperaturregler
Installation and electrical
connection
Operating Instructions | 1473-1-8396
— 7 —
Pos: 32 /#Ne ustr u ktur# /O nlin e-Do kume ntat ion (+ KN X)/M ont age/ alle G erät e/M ont age - UP-Dos en - DIN 49073-1 oder geeignetes Aufputzgehaeuse - Ohne Docvariable @ 25\mod_1340354979636_15.docx @ 219890 @ @ 1
The flush-mounted insert must only be installed in flush-mounted wall boxes according to DIN 49073-1, Part 1, or suitable surface-mounted housings.
Pos: 33 /#Ne ustr u ktur# /O nlin e-Dokumentation (+KNX)/Mont ag e/Te mper at urr egler /M ontag e 1 099 @ 37\ mod_1373545684031_15.docx @ 298631 @ @ 1
Note
Use only in dry rooms!
Fig. 3: Installation
No.
Function
A
Height: 150 cm/minimum distance: 30 cm
B
Avoid mounting on thermal bridges
C
Avoid draught and direct sunlight
D
Avoid the heat radiation of external devices
Fig. 4: Position for putting on the adjustment wheel
Fig. 5: Putting on the adjustment wheel
To put on the adjustment wheel, turn the two arrows towards each other (1). The position lug (3) on the adjustment wheel (2) can now be put on in its normal vertical position.
Pos: 34 /#Ne ustr u ktur# /O nlin e-Do kume ntat ion (+ KN X)/S teuer m odul e - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1
Page 8
Operating Instructions
Busch Temperaturregler
Installation and electrical
connection
Operating Instructions | 1473-1-8396
— 8 —
Pos: 35 /#Ne ustr u ktur# /O nlin e-Do kume ntat ion (+ KN X)/Üb ers chr ift en ( --> Für all e D oku ment e <--)/2. Ebene/A - F/Ele ktrisc her Ans chl uss @ 2 1\mod_1328177051724_15.docx @ 138042 @ 2 @ 1
8.3 Electrical connection
Pos: 36 /#Ne ustr u ktur# /O nlin e-Do kume ntat ion (+ KN X)/A nsc hlus s/T emp era turr egl er/A nsc hlus s 1099 @ 3 7\mod_1373546314562_15.docx @ 298647 @ @ 1
1099 UHKEA
1099 UHK
Fig. 6: Connection to a 2-pipe system
1099 UHKEA
1099 UHK
Fig. 7: Connection to a 4-pipe system
Terminal designation
Assignment
Input 1099 UHK for switchover to cooling mode
Output for controlling the heating load
Output for controlling the cooling load
Note
At high humidity (tendency toward thunder storms) during cooling mode, attention should be paid to dew formation on the cooled surface. Cooling should be reset early or switched off completely to prevent moisture from damaging the
cooled surface.
Pos: 37 /#Ne ustr u ktur# /O nlin e-Do kume ntat ion (+ KN X)/S teuer m odul e - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1
Page 9
Operating Instructions
Busch Temperaturregler
Commissioning
Operating Instructions | 1473-1-8396
— 9 —
Pos: 38 /#Ne ustr u ktur# /O nlin e-Do kume ntat ion (+ KN X)/Üb ers chr ift en ( --> Für all e D oku ment e <--) /1. Eb ene/ G - L/I nbetr iebn ahme @ 11 \mod_1279185496977_15.docx @ 83035 @ 2 @ 1
9 Commissioning
Pos: 39 /#Neustr u ktur# /Onl ine-Dokumentation (+KNX)/Inbetriebnahme/Temperaturregler/Inbetriebnahme - 1099 @ 37\mod_1373547005250_15.docx @ 298663 @ @ 1
Note
When the temperature controller is used for the first time, it has to be taken into account that the switching point precision is not reached until about 1-2 hours of operation after installation. It is recommended to set a temperature that is higher (heating operation) or lower (cooling
operation) than actually desired, to reduce the time required for initial adaptation.
=== Ende der Lis te f ür T e xtmar ke C ont ent ===
Page 10
Operating Instructions
Busch Temperaturregler
1473-1-8396 | 11.03.2014
Pos: 41 /#Ne ustr u ktur# /O nlin e-Do kume ntat ion (+ KN X)/Rüc ks eit en (--> Für alle Dokumente <--)/Rückseit e - BJ E-Variante @ 32\mod_1357201421897_15.docx @ 262132 @ @ 1
A member of the ABB Group
Busch
-Jaeger Elektro GmbH
PO box 58505 Lüdenscheid
Freisenbergstraße 2 58513 Lüdenscheid Germany
www.BUSCH
-JAEGER.de
info.bje@de.abb.com
Central
sales service:
Phone:
+49 (0) 2351 956-1600
Fax:
+49 (0) 2351 956-1700
Notice
We reserve the right to at all times make
technical changes as well as changes to the
contents of this document without prior notice.
The detailed specifications agreed to at the time
of ordering apply to all orders. ABB accepts no
responsibility for possible errors or
incompleteness in this document.
We reserve all rights to this document and the
topics and illustrations contained the
rein. The
document and its contents, or extracts thereof,
must not be reproduced, transmitted or reused by
third parties without prior written consent by ABB.
Copyright©
2014 Busch-Jaeger Elektro GmbH
All rights reserved
=== Ende der Lis te f ür T e xtmar ke B ac kco ver = ==
Loading...