UAF42
2
SPECIFICATIONS
ELECTRICAL
At TA = +25°C, VS = ±15V, unless otherwise noted.
UAF42AP, AU
PARAMETER CONDITIONS MIN TYP MAX UNITS
FILTER PERFORMANCE
Frequency Range, fn 0 to 100 kHz
Frequency Accuracy f = 1kHz 1 %
vs Temperature 0.01 %/°C
Maximum Q 400 —
Maximun (Q • Frequency) Product 500 kHz
Q vs Temperature (f
O
• Q) < 10
4
0.01 %/°C
(f
O
• Q) < 10
5
0.025 %/°C
Q Repeatability (f
O
• Q) < 10
5
2%
Offset Voltage, Low-Pass Output ±5mV
Resistor Accuracy 0.5 1% %
OFFSET VOLTAGE
(1)
Input Offset Voltage ±0.5 ±5mV
vs Temperature ±3 µV/°C
vs Power Supply V
S
= ±6 to ±18V 80 96 dB
INPUT BIAS CURRENT
(1)
Input Bias Current VCM = 0V 10 50 pA
Input Offset Current V
CM
= 0V 5 pA
NOISE
Input Voltage Noise
Noise Density: f = 10Hz 25 nV/√Hz
f = 10kHz 10 nV/√Hz
Voltage Noise: BW = 0.1 to 10Hz 2 µVp-p
Input Bias Current Noise
Noise Density: f = 10kHz 2 fA/√Hz
INPUT VOLTAGE RANGE
(1)
Common-Mode Input Range ±11.5 V
Common-Mode Rejection V
CM
= ±10V 80 96 dB
INPUT IMPEDANCE
(1)
Differential 1013 || 2 Ω || pF
Common-Mode 10
13
|| 6 Ω || pF
OPEN-LOOP GAIN
(1)
Open-Loop Voltage Gain VO = ±10V, RL = 2kΩ 90 126 dB
FREQUENCY RESPONSE
(1)
Slew Rate 10 V/µs
Gain-Bandwidth Product G = +1 4 MHz
Total Harmonic Distortion G = +1, f = 1kHz 0.0004 %
OUTPUT
(1)
Voltage Output RL = 2kΩ±11 ±11.5 V
Short Circuit Current ±25 mA
POWER SUPPLY
Specified Operating Voltage ±15 V
Operating Voltage Range ±6 ±18 V
Current ±6 ±7mA
TEMPERATURE RANGE
Specification –25 +85 °C
Operating –25 +85 °C
Storage –40 +125 °C
Thermal Resistance,
θ
JA
100 °C/W
The information provided herein is believed to be reliable; however, BURR-BROWN assumes no responsibility for inaccuracies or omissions. BURR-BROWN assumes
no responsibility for the use of this information, and all use of such information shall be entirely at the user’s own risk. Prices and specifications are subject to change
without notice. No patent rights or licenses to any of the circuits described herein are implied or granted to any third party. BURR-BROWN does not authorize or warrant
any BURR-BROWN product for use in life support devices and/or systems.
✻ Same as specification for UAF42AP.
NOTES: (1) Specifications apply to uncommitted op amp, A
4