may result causing property damage,
personal injury or death.
Do not store or use gasoline or other
ammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
•
Do not touch any electrical switch; do
•
not use any phone in your building.
Immediately call your gas supplier from
•
a neighbor’s phone and follow the gas
supplier’s instructions.
If you cannot reach your gas supplier,
•
call the re department.
Installation and service must be
performed by a qualied installer, service
agency, or the gas supplier.
IMPORTANT: READ THESE INSTRUCTIONS
CAREFULLY BEFORE STARTING
INSTALLATION OF THIS FIREPLACE.
Logs and burner must be permanently installed in and
are only for use in this fireplace. This fireplace must
be connected to a working flue meeting the
requirements of the ANSI Z21.50 standard.
Solid-fuels shall not be burned in this replace.
This appliance must be vented vertically through the
roof. This appliance is not for installation in manufactured
or mobile homes. The installation, including provisions
for combustion, ventilation air, and required minimum
permanent vent opening, must conform with the National
Fuel Gas Code (ANSI Z223.1/NFPA 54) and applicable
local building codes. This gas replace i s designed to
burn with yellow ames; t hus adequate ventilation is
absolutely necessary.
WARNING:
This gas appliance must not be connected to a chimney
fuel servicing a solid fuel burning appliance.
Do not store gasoline or other ammable vapors and liquids in the vicinity of this or any other appliance.
Installer: Leave these instructions with the consumer.
Consumer: Retain for future reference.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certied kit is used.
*Sold Seperately
ICC Evaluation Services
Report No. 2401
rev 5-31-2013
THIS PAGE INTENTIONALLY LEFT BLANK
CONTENTS
NGLP
6.5”
6.25”
MFG. DATE:
SERIAL No.
This appliance is not for installation in manufactured or mobile homes.
rev 19 NOV 2012
GAS
TYPE:
DO NOT REMOVE THIS LABEL
See Burntech Installation & Operating Instructions for
this model. Contact local building officials about
restrictions and installation specifications in your area.
THIS FIREPLACE IS DESIGNED
FOR USE ONLY WITH THE ANSI
Z21.50 DECORATIVE GAS LOGS
AND BURNER TESTED AND
APPROVED FOR THIS FIREPLACE.
Consult instructions included with this
firebox for further information.
!
WARNING:
Use only approved, listed chimneys
10” B-Type Vent and DM-12-10” system
(1) BFMP525 (included)(1) GBV-DH10 (included)
Chimney Heights:
Max.: 40 ft.
Min.: 14 ft. (17 ft. with 1 or 2offset
sections maximum)
IMPORTANT: Refer to pipe
manufacturer’s instructions.
!
WARNING:
THIS FIREPLACE HAS BEEN TESTED
FOR USE ONLY WITH APPROVED
GLASS DOORS. TO REDUCE THE
RISK OF FIRE OR INJURY, CONSULT
OWNER’S MANUAL.
THIS APPLIANCE NEEDS FRESH AIR FOR SAFE OPERATION AND MUST BE INSTALLED
SO THERE ARE PROVISIONS FOR ADEQUATE COMBUSTION AND VENTILATION AIR.
!
WARNING:
THIS FIREPLACE IS NOT INTENDED FOR BURNING SOLID FUELS.
!
WARNING: This gas appliance must not be connected to a chimney fuel servicing a solid fuel burning appliance.
!
FIREPLACE CLEARANCES TO COMBUSTIBLES:
UNIT FRONT, SIDES, REAR.......................................0”
INSULATION FROM FIREBOX...................................0”
The installation, including provisions for combustion, ventilation air, and required minimum permanent vent opening,
must conform with the National Fuel Gas Code (ANSI Z223.1/NFPA 54) and applicable local building codes.
Fireplace Parts List ..........................................................................................................................Pg. 2, 3
Burner and Logs Parts List .............................................................................................................. Pg. 4
Appendix I ........................................................................................................................................Pg. 23
Appendix II .......................................................................................................................................Pg. 24
Your replace must have a rating plate like the sample shown below and should be located inside the lower dome side of your replace.
Model Number, Date of Manufacture and Serial Number should be stamped on the plate where indicated.
EXAMPLE ONLY
1
Figure 1
WARNING
Failure to position the parts in
accordance with these diagrams or
failure to use only parts specically
approved with this appliance may result
in property damage or personal injury.
Fireplace Parts List
12
9
11
10
8
7
6
10
17
5
4
8
7
16
14
15
2
1
See Page 8 and 9 for framing anchoring components.
(Herringbone Pattern shown, also available
in Running Bond - see Pg.27)
ITEM P/NDESCRIPTION
TFS39-1
1
2
3
3A
4
5
6
7
8
9
10
11
12
14
15
16
17
TFS44-1
TFS49-1
TFS39-2
TFS44-2
TFS49-2
TFS39-3
TFS44-3
TFS49-3
TFS39-3A
TFS44-3A
TFS49-3A
TFS39-4
TFS44-4
TFS49-4
TFS39-5
TFS44-5
TFS49-5
TFS39-6
TFS44-6
TFS49-6
TFS39-7
TFS44-7
TFS49-7
TFS39-8
TFS44-8
TFS49-8
GBVS39-9
GBVS44-9
GBVS49-9
TFS39-10
TFS44-10
TFS49-10
GBVS-186-1
TFS-DD*
TFS-211
TFS-212
TFS-213
INCLUDED
HEARTH (Left or Right)
REAR WALL
SIDE WALL
SIDE WALL with 4” opening for Air Kit
SMOKE SHELF (Downdraft Diverter)
DOME REAR - LOWER
LINTEL
DOME SIDE - LOWER
DOME SIDE - UPPER
DOME TOP Ø10”
DOME FRONT/REAR
RATING PLATE
10” DRAFT HOOD
SMOKE DIVERTER
SMOKE DIVERTER EDGE PIECE
SPILL SENSOR SWITCH
#4 REBAR (Ø1/2”) x 28”
QTY
2
3
7
1
1
1
1
2
2
1
2
1
1
1
2
1
8
Only the following
doors have been tested
and approved for use
with this fireplace:
Crown-Breckinridge
or
McKenzie-Pendelton
* ITEMS NOTED ARE SOLD SEPARATELY.
ITEMS INDICATED AS “NOT SUPPLIED” CAN BE OBTAINED FROM YOUR LOCAL HARDWARE STORE.
3
*BURNTECH Supplied Burner & Logs Parts List
Before beginning installation, be sure the burner system is complete by comparing its contents with this Parts List. Parts may
differ depending upon the size of the set purchased. Be sure you know the model number and size of your set when
ordering replacement or optional parts and accessories. Burner, Log Kit and remote are sold seperately.
7
9
10
LML-24 shown.
WARNING: THIS FIREPLACE IS DESIGNED FOR USE
ONLY WITH THE ANSI Z21.50 DECORATIVE GAS
LOGS AND BURNER TESTED AND APPROVED FOR
THIS FIREPLACE.
Any change or alteration in burners or log sets must be
8
2
approved by Burntech in writing or warranty will be null
and void.
BTU's can never exceed more than 65,000 on Models
GBVS 39 and 44 and 80,000 btu's on Model GBVS 49.
Unapproved changes or alterations could result in a fire
or explosion resulting in property damage, personal
injury or death.
11
Diagrams shown are not to scale.
12
6
5
3
1
ITEM P/NDESCRIPTION
GMLB-39/44-01(P)
1
GMLB-49-01(P)
RR-1A
2
CK-5-18HCSource connector kit
3
CK-5-24HCBurner connector kit
4
CE-01Valve/Control box w/ batt.
5
OCC-10Lava Rock, 10 lb. bag (4)
6
LML-15TTop log 15”
7
LML-17TTop log 17”
8
LML-18TTop log 18”
9
LML-20TTop log 20”
10
LML-24BR
11
LML-30BR
LML-24BF
12
LML-30BF
TFS-214Burner Grate Brackets (2)
13
Pilot, Burner assembly
Remote trans./recvr. w/ batt.
Rear bottom log 24”
Rear bottom log 30”
Front bottom log 24”
Front bottom log 30”
QTY
1
1
1
1
1
1
1
1
1
1
1
1
2
Receiver pre-assembled
4
into control box.
13
Contact BURNTECH for replacement parts and
accessories as listed in these parts lists.
*SOLD SEPERATELY
4
Product Overview
40 5/8"
4 3/8"
7 3/8"
A/2
11"
28"
21"
23"
C
B
4 1/4"
A
32 7/8"
63-1/2”
D
ø4” OUTSIDE AIR
ACCESS - CAN
BE INSTALLED
ON THE LEFT
SIDE ALSO
Introduction
Thank you for choosing Burntech® Fireplace Solutions.
Rest assured our products have been tested for safety and
durability for many years when properly installed by following
this manual completely.
Attention: You may need a residential building permit to install
a Burntech® Fireplace. Consult local jurisdictions before you
get started!
The Burntech® gas replace is not designed to serve as a
primary heat source, rather, the replace was expressly created
as a supplemental source of heat. This unit is designed for use
with the provided gas burner and approved logs only.
Product Overview
Burntech® Fireplaces are designed as factory-built blocks to
be assembled on-site. These replaces may be installed on
either combustible or non-combustible oors. In order to function, the system requires a 10” B-vent chimney.
The main components of your Burntech® Fireplace are:
Burntech® Firebox and Smoke Dome
●
Gas burner, logs and control system (sold seperately)
●
B-vent Chimney Pipe(Sold Seperately)
●
The main categories of the installation of your Burntech®
Fireplace are:
Clearance to combustibles
●
Familiarity with all the components for the installation
●
Foundation strength of your Burntech® replace
●
Chimney system measurements
●
Set up and use of the gas burner system.
●
Choice of materials and craftsmanship in replace and hearth
●
nishing.
Figure 4 - Typical Installations
Internal
Wall
Installation
Corner
Installation
Testing and listing for the Burntech® gas replace has been
undertaken by PFS Test Laboratories, Inc. to ANSI Z21.50.
Under no circumstances should the Burntech® gas replace be
considered for other than in-residence buildings of conventional
construction.
These components make up the Burntech® gas replace and
in the following pages, you will learn how they work together
to create an exceptional unit that will give years of service and
pleasure!
Figure 5
Full
Projection
Flush
Installation
Installation
Note that each of these topics will be covered in detail and that
the installer is expected to understand each phase completely
before going on to subsequent instructions.
Attention: Be advised that all the illustrations in this manual
are for general reference only. Do not scale drawings. Actual
design elements will vary from case to case. Pay attention to
specied minimum clearances to combustibles.
WARNING! Under no circumstances should you allow children
to remain unattended while a re is burning in the replace! Be
sure to keep all objects – furniture, drapes, rugs, etc. at least
48” (48 inches) away from the opening of the replace!
Overall Dimensions Burntech® Fireplaces
ModelABCD
GBVS3943”39”30-1/4”27-3/4”
GBVS4448”44”35-1/4”32-3/4”
GBVS4953”49”40-1/4”37-3/4”
5
Required Gas Pressure
The minimum inlet gas supply pressure for the purpose of
input adjustment is 5” of water column (w.c.) for natural gas.
The maximum inlet gas supply pressure is 10.5” w.c. for
natural gas. The minimum inlet gas supply pressure for the
purpose of input adjustment is 11” of water column (w.c.) for
propane gas. The maximum inlet gas supply pressure is 13”
w.c. for propane gas.
Testing the Gas Supply System
The gas replace and its required individual shut-off valve
must be disconnected from the gas supply piping system
while performing any tests of the piping system at pressures in
excess of 1/2 psig.
The gas replace must be isolated from the gas supply
piping system by closing its individual manual shut-off valve
during any pressure testing of the gas supply piping system at
test pressures equal to or less than 1/2 psig.
This is accomplished by closing the gas supply line valve
required by NFPA 54.
A replace screen must be replaced after service and be
in place when the appliance is in operation and, unless other
provisions are provided, the screen shall have an opening for
introduction of combustion air.
When glass replace doors are used, operate the gas
replace with the doors open. Use only doors rated for this
appliance.
GUIDELINES FOR USE:
All current and future users of Burntech® Fireplaces
are charged with the responsibility for full knowledge of the
information contained within this manual which includes:
Strict requirements for assembly.
•
Detailed instructions for installation.
•
Cautionary guidelines for use.
•
On-going maintenance instructions.
•
It is the responsibility of the distributor, subcontractor and/
or the general contractor – whoever shoulders the liability
for installation of this product – to see to it that the work is
in complete compliance with the guidelines and instructions in
this manual.
Note that the general contractor is the party accountable for
seeing that adequate clearances are provided from all rebox
surfaces per specications in this manual.
DO NOT USE A FIREPLACE INSERT OR OTHER PRODUCTS
NOT SPECIFIED FOR USE WITH THIS FIREPLACE.
The Burntech® GBVS Fireplace is Designed for Use Only
with:
- Burntech approved burner and log system
- Plumbed LPG or Natural Gas.
DO NOT USE OR STORE GASOLINE OR OTHER
FLAMMABLE LIQUIDS OR GASES IN OR NEAR THE
FIREPLACE!
Important
To comply with building code acceptances, and for safe
operation and proper performance of this replace, use ONLY
Burntech® parts and accessories.
Use of other controls, parts, and accessories which are not
designed for use with Burntech® gas replaces is prohibited
and will void all warranties, certications, listings, and building
code approvals, and may cause property damage, personal
injury, or loss of life.
The burner included with this gas replace is non-convertible
and only meant to be used with the gas listed on the rating
plate.
ATTENTION: A re or an explosion could occur causing
property damage, injury or loss of life if you do not follow the
information in this manual!
6
Clearance to Combustibles
Burntech® Fireplace & Chimney Systems
The distance to be maintained from the surfaces of the
replace to combustibles must be observed. Below is a list of
the most common combustible materials to name a few:
Due to high temperatures, never install this replace in a
recreational vehicle, in high trafc areas, drafty areas, or
where curtains, furniture, clothing, or other ammable objects
are less than 36” from the front or side and 42” from the top of
the replace.
CAUTION: This gas replace attains high temperatures. Keep
children and adults away from hot surfaces to avoid ignition of
clothing and/or burns. Even after the replace is shutdown it
will remain hot for a time afterward. Allow the surface to cool
before touching it.
Carefully supervise young children when they are in the room
with the replace.
All replace openings for both combustion air and exhaust
must remain open and unobstructed at all times when the
replace is in operation.
The Burntech® replace has been designed, tested and
approved for zero clearance to combustible oors.
Be certain that the Burntech® replace is installed with the
nished re brick oor of the replace so that it is at least 4-1/2”
(four and a half inches) above the combustible oor system.
Warning to the structural engineer and/or building contractor:
It is your responsibility to be certain that the replace can be
properly supported by the combustible oor system on which
the replace will rest. Be advised that this engineering equation
will be in addition to any live or dead weights that the oor has
to carry.
8”
(203 mm)
8”
(203 mm)
12” (305 mm)
20” (508 mm)
0”0
Before Getting Started…
Even if you consider yourself an expert in the field of
fireplace installation, we at Burntech® caution you to take the
time to totally familiarize yourself with the instructions to
follow.
We can assure you that there will be information that will
make the installation go smoother and, above all, safer, for
everyone concerned. At the least, reading these procedures will
save you time and, at the most, it will prevent any malfunction
that could result in property damage or serious injury.
Do not start the installation until you have checked out all
the local, regional, state and national rulings, laws and codes
as they apply to replaces and replace installations. Every
community is different so do not assume that because you
know the requirements for one locality, it will be the same in
the next. Avoid bureaucratic hassles and do your homework
WELL BEFORE you start your project!
The Burntech® gas fireplace is designed to be installed
1)
with properly sized B-vent metal chimney or "Class A" UL
103 chimney. BVent chimney or “Class A” chimney
systems must be used on all Burntech BVent Fireplace
systems. Note that the chimney system must always vent
to the outside of the building.
This Burntech® replace is intended as a supplemental heat
2)
source only. It is not intended as a primary heat source.
It is the responsibility of the contractor installer (not the
3)
manufacturer) to ensure that adequate combustion air is
provided for proper function of this replace. Fireplaces
take up a large volume of replacement air from outside the
house and if the house is of airtight construction,
dangerousgas spillage may occur if proper draft is not
achieved.
There are many conditions beyond a manufacturer’s
4)
control when it comes to the operation of the fireplace.
The manufacturer cannot be responsible for spillage free
operation, nor can the manufacturer take on the
responsibility for problems with surrounding construction;
chimneys that have not been built at the right heights;
system drafts caused by faulty mechanical systems;
adverse weather conditions or any other inclement
environmental situations.
Inspect all replace & chimney components for evidence
5)
of damage prior to starting installation. Consult your local
distributor for replacement parts if necessary.
Under no circumstances should you make any adjustments
6)
or modications to the chimney system during the
installation procedure. If you do, you are not only liable
for negating the warranty, but you could very well cause a
serious malfunction of the replace. You must follow these
chimney instructions.
Chimney System Heights
When installed, the maximum overall height of the Fireplace is
40’-0” (forty feet). The minimum installed height of the
completed replace is 14’ 0” (fourteen feet), given that the
chimney is straight. If the chimney includes one or more offset
sections, the measurement is 17’ 0” (seventeen feet).
7
Supporting Floor Systems
I-Joist
I-JOISTS
Anchor
Brackets
It is the ultimate responsibility of the installer to ensure that
proper concrete slab supports are used.
WARNING to the licensed design professional and/or building
contractor: It is your responsibility to be certain that the
Burntech® can be properly supported by the combustible oor
system on which the replace will rest.
For replace support foundations installed on concrete refer to
Appendix I and II (pages 31 & 32) for specic instructions.
Rebar locations
Lay-out the position of the replace and drill holes where
the rebar will be located. Secure the #3 rebar 4 inches into
the concrete foundation with ITW Epoxy or Simpson Epoxy.
Follow manufacturer’s instructions for installation of rebar into
slab.
Wood Floor
Anchorage of replace to wood oor construction is required.
Refer to Figure 9 for anchorage dimensions. Four anchors are
required to attach to the sub-ooring framing.
Crawl Space or Upper Floor:
For installation of rebox over combustible crawl spaces or
upper oors, anchorage of the rebox is required. Illustrations
of examples of possible anchorage methods are shown in
Figures 6 thru 8 depending upon the type of oor framing. Final
method of anchorage is to be determined by licensed design
professional.
For conventional framing, where the oor joists are parallel
with the sides of the rebox, the addition of oor joists to align
with the anchor brackets allows the brackets to be directly
connected to the oor joists.
Figure 6
Metal Base
Assembly
2X FLOOR JOIST
EXAMPLE ONLY
Floor Sheathing
not shown for
clarity
Figure 7
I-Joist Anchoring
Top View
A35 Brackets
(16 required)
2X FLOOR JOIST
Note that additional oor joists may be required to support
the weight of the rebox and chimney. Where the oor joists
run parallel to the front of the rebox, anchorage can be
accomplished in like manner as shown in Figure 6 using
blocking between the oor joist.
For oors supported by I-Joists, the method of anchorage is
illustrated in Figures 7 and 8. Figure 11 illustrates the general
arrangement of anchorage to oor framing.
It is important to take into consideration that the load for
the Burntech® Fireplace must be considered as additional
dead load that will have to be supported by the oor framing.
Additional oor joists or I-joists may be required as determined
by the licensed design professional.
The dead weights for the replace are noted in Table I. It is
the task and responsibility of the general contractor/installer
to see that the proper reinforcement for weight loads are
made by a licensed design professional prior to the replace
installation.
As stated above, it is desirable to place additional framing
for alignment of anchor rods. Refer to Figure 9 for anchor rod
locations.
Simpson
Strong-Tie
A-35 or
equivalent
Figure 8
I-Joist
Anchoring
Bottom
View
Example Only
Example Only
8
Burntech® Weight Determination
F
10"
4"
Fireplace
outline
10”
The following are dead load weight estimates for the Burntech® Fireplaces.
Table I
Fireplace Model
Fireplace Weight
Mortar, Rebar &
Ready Mix Concrete
Firebrick Lining
GBVS39GBVS44GBVS49
1,194 lbs.1,250 lbs.1,359 lbs.
350 lbs.357 lbs.364 lbs.
333 lbs.345 lbs.356 lbs.
Draft Hood
Floor Area
Other Weight Considerations:
Fireplace nished facing (surround): This information needs to be obtained from the contractor.
1)
Weight of metal ue: See chimney manufacturer’s weight specications. Some chimney systems can weigh up to 50 lbs per
2)
lineal foot.
17 lbs.17 lbs.17 lbs.
42” x 28” (8.12 ft²)48” x 28” (9.33 ft²)53” x 28” (10.30 ft²)
Table II - Deection Limits
ConstructionLS or WD +L
Floor Members
1
For wood structural members having a moisture content of less than 16 per cent at time of installation and used under dry
conditions, the deection resulting from L + 0.5D is permitted to be substituted for the deection resulting from L + D.
Note that Burntech® cannot accept responsibility for structural oor support details. All drawings are presented as mere illustrations
to indicate the presence of the underlying oor system. It is the responsibility of the general contractor/installer to consult with a
local licensed design professional for guidance in building a proper oor support system.
ATTENTION: Figure that these totals for the dead loads are in addition to the actual live load as well as other dead load
requirements for the specied site’s proposed oor. Only the Burntech® weights are known. Other weights are estimates and
are subject to material choices of the installer or owner.
Figure 9
I/360---I/240
A
1
Figure 10
ModelA
GBVS3938-3/4”
GBVS4443-3/4”
GBVS4948-3/4”
Figure 11
Typical Anchorage
Layout
EXAMPLE ONLY
SECTION VIEW
ROTATED 90CW
9
What You Will Need
You will nd that the Burntech® Fireplace is designed to be
completely assembled on-site, consisting of interlocking
precast parts. The parts of the replace are made of
Burntech®’s incredibly strong blend of specialty cement and a
light weight aggregate.
IMPORTANT! When applying mortar, it is imperative that the
concrete blocks be maintained moist (not soaking) so they don’t
absorb the water out of the mortar and cause adhesion to fail.
Frequently run a damp sponge to the parts before mortar is
applied!
The installation of an anchor plate/damper is required but not
supplied. You may purchase it from any chimney manufacturer
or Burntech®. Also, an optional combustion air inlet BFP4-AK
can be obtained from Burntech®.
Refractory Firebrick Liners also need to be installed. These
should be a minimum of 1-1/8” (one and one-eight inches) thick.
The liner will be applied within the walls and hearth area of the
rebox. These are available from Burntech®. See page 27.
SURFACE CRACKS - The Burntech® replaces are
manufactured using high quality materials. During the
drying process, surface cracking may occur. These small
cracks (under 1/16” will not affect the replace safety or
performance). During the assembly process, ll surface
cracks with thin-set mortar and brush when drying for a
smooth surface nish.
Field Assembly Procedures
Mixing the Burntech® mortar – The mortar comes premixed
a)
and should be dry. Be sure to use clean water and work it
up into a mixture that is pasty but not lumpy. If it’s too thin
and the surfaces don’t stay moist, the components will not
adhere. Load the mixture into a standard grout bag.
Apply about ½” (one-half inch) thread of mortar. The mortar
b)
bead should be approximately ½” (one-half inch) away from
all edges. The mortar has a considerable amount of holding
power so do not overload the components with too much
mortar. Keep the components moist at all times!
Tools needed for installations:
●
One 4’ level
●
Roto-hammer with ½” drill bit (needed for concrete slab
install only)
●
Drill motor with mixer blade (to mix Burntech® Mortar)
●
Two empty 5 gallon buckets (to mix Burntech® Mortar)
●
One wheelbarrow and shovel to mix concrete.
●
Grout bag
●
Triangular masonry trowel
●
Rubber hammer
●
Sponge and water bucket to wipe down and moisten parts
prior to applying mortar.
Materials needed for concrete slab installations
GBVS39:
Six (6) pieces 3/8” rebar x 36” long (included with unit)
Six (6) pieces of rebar x 12” long (included with unit)
GBVS44/49:
Eight (8) pieces 3/8” rebar x 36” long (included with unit)
Eight (8) pieces of rebar x 12” long (included with unit)
ALL UNITS:
●
Epoxy for securing rebar in footing / foundation.
●
Three (3) - 90 lb. bags of Ready-Mix Concrete with 1/4” or
smaller aggregate.
Some mortar will “ooze out” when placing components
c)
together, this is normal. Wipe excess away with a trowel. Do
not cover component surfaces completely with mortar. Do
not apply the mortar in thick bands even if the component
you are working with is larger than the rest. You will want to
apply “stripes” of mortar in these situations.
Make sure components are level. It’s extremely important
d)
that you pay careful attention to how you are assembling
the Burntech® Fireplace since every component builds on
the next. If you have to make any kind of an adjustment,
do not try to do it “by loading an opening” with mortar, this
will only result in a replace that will not be plumb or level.
Use wood shims instead. You will nd these small wood
shims supplied with the Burntech® Fireplace and
you can nudge them in between openings to achieve the
precision you need in making component adjustments.
Once you have removed any shims, you will want to cover
any gaps that may have resulted with the mortar.
Materials needed for wood floor installations
GBVS39:
Six (6) pieces 3/8” rebar x 36” long (included with unit)
Six (6) ea. All-thread x 12” long (with nuts and washers)
GBVS-44/49:
Eight (8) pieces 3/8” rebar x 36” long (included with unit)
Eight (8) ea. All-thread x 12” long (with nuts and washers)
ALL UNITS:
Three (3) - 90 lb. bags of ready mix concrete with 1/4” or smaller
aggregate.
10
Fireplace Assembly Procedures
Place the Burntech® replace hearth on the oor where the
1.
replace is to be installed. For concrete slabs, supporting
oor needs to be rated at ASTM 90.
Draw an outline of the hearth area based on the dimensions
2.
shown in Figure 12. Position Hearth slabs and mark rebar
center locations. Drill 4 inches into concrete slab and secure
the 8 pieces of 12 inch rebar with epoxy. For other than
concrete slabs, draw an outline of the hearth area based on
the dimensions in Figure 5 taking special consideration on
the position of where the all-thread studs will be located in
relation to the anchoring locations. All-thread rods should
stick up through the holes on the hearth slabs.
Figure 12
Left Side Hearth 2nd
Right Side Hearth 1st
Apply mortar
between joints
28”
Figure 14
Before installing side walls, conrm placement of outside
6.
Hearth shown prepared
for Left Side position
combustion air access (if required), this can be installed
either side depending on which side is accessible to outside
combustion air (all diagrams in this manual show the
combustion air inlet hole on the right side). Prepare side
wall and rear wall mating surfaces with the prepared mortar
and begin assembly.
Figure 15
Side Wall shown prepared for Right
Side Air Access.
For Left Side, bead opposite side.
ModelW
GBVS-3943”
W
12 inch rebar
Mix a batch of mortar and prepare Right Side Hearth bottom
3.
GBVS-4448”
GBVS-4953”
surface to be bonded as shown in Figure 13.
Align Right Side Hearth to the outline created. The overall
4.
width should allow for an approximate gap of 1/8” between
slabs for the additional mortar to unite the remaining slab.
Check for surface atness, level if necessary.
Figure 13
Apply mortar bead to
all mating surfaces.
Hearth section shown prepared
for Right Side position
1/2” mortar
bead (typical)
1/2” away
from edges
1/2” AWAY
FROM EDGES
7.
Keep the assembly of the next sections of the rebox side
walls moving up, keeping components moist, mixing mortar
as you need it and threading the mortar appropriately as
you stack each section, one onto the next. Constantly check
for squareness and levelness while building each course of
block. As you complete each section, make certain that you
adhere the mortar at each and every joint.
Figure 16
Side Wall
Apply
mortar
Apply mortar
Rear Wall
Side Wall
Apply mortar to the remaining Hearth except this time
5.
apply beading on surface to be facing oor as shown in
Figure 14.
Combustion Air Access
Right or Left (Right shown).
11
8.
Install Downdraft Diverter and nal row of Side Walls
(Figure 17). Then place #3 rebar (8 each, 36 inch long)
vertically through the cells until they reach bottom. Position
them adjacent to the rebar or all-thread sticking up from the
hearth.
9.
All components must be level. Mix approx. 2 cu. ft. of ReadyMix Concrete. Fill all cells with Ready-Mix Concrete mix.
Assemble Lower Dome Sides as shown in Figure 20. The
11.
beveled face lines up with the inward angles of the lintel
sides. Resulting top surfaces should be level.
Figure 20
Lower Dome Sides (Rating
Plate faces inside)
Figure 17
Downdraft
Diverter
12 inch
rebar or
all-thread
10.
Set the Lintel and Lower Rear Dome as shown in Figure
19. Check that all is level. If adjustments are needed, use
shims and ll gaps with an appropriate amount of mortar.
Note: Although you are cautioned to use Burntech® mortar
sparingly because it does have such holding power, you
should look over the rebox assembly at the end and ll in
any gaps, especially joint connections, with the mortar.
Figure 19
Lintel
Lower Rear
Dome
12.
Verify that the smoke dome side, front and rear walls are
aligning correctly and that the surfaces are smooth and
uniform. Make sure connections are covered with an
adequate amount of mortar. Remember that you have the
option of using shims but they must be removed and any
holes lled. Make any adjustments to the replace alignment
before continuing to the next step.
13.
Assemble Upper Dome and Dome Sides as shown in
Figure 21. Check your assembly here. If things are
proceeding as they should be, the nished top surface
should be at and level.
Figure 21
Upper Dome
Front/Rear
Upper Dome Sides
Important: Adjustments can only be made while the mortar
is still wet when correcting for squareness and leveling.
14.
Finally, set the Dome Top into position. Be sure that it is
ush in every direction as you place it on the crest of the
smoke dome wall assembly. After this is done, proceed to
section on “Installing Damper and Chimney System”.
Note: The chimney hole on the Dome Top is not centered from
front to back - it should be offset closest to the rear of the
replace (see Figure 22).
Figure 22
Center of chimney hole is
offset towards the rear.
10”
12-1/2”
GBVS-39/44/49
12
Burntech® Firebrick Liner
The rebrick lining is not supplied as part of your Burntech®
replace but can be purchased from Burntech®. They are
available in split herringbone and full running bond patterns.
(see Figures 24 and 25)
You also have the option to have custom rebrick installed,
but it must be at least 1-1/8” thick.
Before you install the lining, you will need to drill all the
required gas and electrical line feeds and the combustion air
supply access holes.
Disclaimer:Burntech® cannot be held liable for the way
firebrick or firebrick mortar performs. It is not unusual for heat
stress cracks to appear on the firebrick or firebrick mortar
during the life of the fireplace.
Insertion of Leg Bracket
Insert metal grate leg lock bracket underneath the rear bricks as
shown and cement in place.
Figure 23
Insert leg here
Firebrick
Bracket
Figure 24
Figure 25
Fireplace Finishes & Combustible Trim Clearances
Mantel and Mantel Shelf Clearances – As with any radiant
1.
heat replaces, all Burntech® Fireplaces must comply with
building code safety clearances, per units that have
openings of 6 sq. ft. (six square feet) or greater. You must
keep combustibles such as trim 8” away from the rebox
opening (for mantel clearances, see Figure 26).
Figure 26
Combustible material
8”
Shelf or trim
safe zone
1”
One-way
screw
Cement in place
Burner
leg
Width of back
grate legs (cen-
ter)
12”
3”
Upper
replace
area
1.5”
Distances to underside
of shelf or trim
Mantel and side clearances
Attention: The manufacturer suggests that when building
out a replace, that the owner and installer opt for complete
safety. Burntech®, therefore, advises that combustible
mantel shelves feature clearances that are more than the
12” (twelve inch) minimum equal to the projection of the
shelf. As a guide, gure that a 10” (ten inch) wide shelf
should be 20” (twenty inches) above the replace opening.
Walls That Adjoin – Safety codes and all practical outlooks
2.
insist that your replace cannot be installed closer than 2 ft.
(two feet) to any walls in the room the replace is housed in
or to any walls of adjoining rooms.
13
Caution in Regards to Combustibles – If any part of the
3.
replace or objects in the room (curtains, rugs, paint,
cushions, etc.) start to show warping or discoloration due to
heat from the replace, it is time to take immediate action.
Each installation requires a different set of circumstances
to deal with the problem, but one thing is certain: do not
use the replace until you have gured out how to address
the problem. You are facing a potential re hazard. The
manufacturer of the Burntech® gas replace cannot be
responsible for the make-up of material on the exterior
of the replace you have chosen, nor can Burntech® be
held responsible for the materials in a room that may be
responding negatively to heat. However, in almost all
cases, there is a solution to the problem, either by making
adjustments to airow or the room itself.
Installing Outside Air
Note that the most important aspect of the installation is the
maintenance of minimum required clearances to combustible
materials. Those specic installation requirements must
be followed with great precision as you are dealing with the
potential of re hazard if the correct combustible limit is not met
and maintained. When you look at the drawings provided in this
section, you will see that actual installations may vary due to
individual design preferences. That is to be expected.
Design and framing specics may vary from the drawing
to installationy. Clearances to combustibles is a stringent
requirement.
WARNING:
If you do not use chimney manufacturer’s parts and/or if you
do not follow exact instructions for installation of chimney
components, you may be responsible for replace malfunction,
an accident or a re hazard.
Be mindful that outside, fresh air is not required for the
1.
operation of the Burntech® Fireplace. However, local
building codes may require combustion air and it is an
excellent choice in some situations, especially in weather
conditions where homes are very well insulated and
tightly sealed. Check local building codes for specic
requirements.
Install Outside Air Kit - BFP4-AK into the Burntech®
2.
Firebox either through the side wall opening provided. The
tubing that goes out of the rebox wall must feed into a
exible metal conduit as the source for outside combustible
air. It can go straight out through an outside wall or into a
ventilated crawl space. If crawl space is used, check codes
for proper termination.
Be sure that you carefully check the source of the outside
3.
air before you choose the site for your air intake. You don’t
want a place where snow will collect, where bushes or trees
will be growing or a location that is too close to any other
structure.
The suggested maximum height for the air intake tubing
4.
is 50 ft. (fty feet) above the hearth. That height is if the
intake nishes off at a minimum of 3 ft. (three feet) below
the chimney cap level.
Install a screened termination cap to keep out animals.
5.
Burntech® Chimney Systems
Overview
This Burntech® gas replace may be installed with an approved
10” B-vent chimney system. A metal chimney adapter is required
to attach the chimney to the top of the rebox. This can be
purchased from Burntech, part number TFS-DD.
Attention: Be advised that your choice of Chimney System
meets the following standards and requirements:
Designed for installation in accordance with National Fire
●
Protection Standard
Meets requirements of NFPA 211
●
Designed in accordance with BOCA Basic National Codes
●
Meets Uniform Building Codes.
●
General Chimney Requirements for Height and Clearance
When installed, the maximum overall height of the chimney
system from bottom of replace to the top/termination chimney
is 40 feet. The minimum installed height of the completed
Chimney System is 14 feet with a straight ue stack, 17 feet if
the chimney includes one or two offset sections.
Throughout the length of the chimney – along the outer
periphery of the ue you must have at least 1” (one inch) of
clearance all around the circumference. When the chimney is
passing through a living space, it must be completely closed off.
A “live” chimney is never allowed to be within reach of humans;
the chimney must be completely designed to be hidden from
view and protected, away from human interaction.
Note that it is acceptable for the chimney’s restop space and
roof ashing to come in direct contact with common construction
materials, such as drywall, ooring, paneling, plywood, millboard,
particle board and a variety of normal framing materials. Always
follow the specic installation requirements of your selected
chimney manufacturer.
Determining Finished Height for Fireplace
Installers are cautioned to put the chimney system together
exactly as instructed and shown in chimney manufacturer’s
guide. Any variations may have serious consequences resulting
in an accident or malfunction. If instructions are not followed,
the warranty on the product will become null and void.
Determine the number of chimney sections and the chimney
components that will be required for the installation. Bear
in mind that the minimum height of the Burntech® Fireplace
System once installed is 14’-0” (fourteen feet) and that it is
higher if offsets are used. Here is how to calculate the height of
the completed replace:
14
First, ascertain the height of the chimney. This includes the
1.
distance from the very top of the smoke dome to where the
top of the ue ends. That is where the smoke leaves the
ue.
Aside from the chimney sections, include all the components
2.
that you will be using in your installation - anchor plate
damper, restop spacers, stabilizers, and offsets.
Create a Component Height Chart by measuring each
3.
component and completing the following:
Anchor Plate = 4 ”
Firestop Spacers = _ _ _ _ _ _
Support box = _ _ _ _ _ _
Stabilizers = _ _ _ _ _ _
Offsets = _ _ _ _ _ _
Pipe Sections = _ _ _ _ _ _
(Stabilizer – Must be present on vertical chimneys every
30 feet and on offset chimneys every 10 feet.)
Take the total height of every component that will be included
4.
in your installation and then subtract that from the desired
total height you wish the nished replace system to be.
You will need to refer to the chimney manufacturer’s
5.
information in order to gure out the available lengths and
the quantity of the sections that you will need.
The Special Case of Offset Installation
Special instructions are given for proper handling of offsets for
the chimney system.
One elbow begins the installation procedure and the second
elbow is used to nish off each section. In all likelihood, a 30
degree offset elbow will probably be the rst hardware used off
the top of the anchor plate damper.
Note: Under no circumstances should you use an offset
elbow in place of a return elbow. They have distinct purposes
in the conguration of the offset installation and they cannot
be interchanged, part for part.
Depending on the conguration you are contending with,
2.
you may either attach the elbows and offset piping together
or you may need to insert sections of the vertical chimney.
Whatever the scenario, you cannot allow sections of the
chimney to measure more than 20’ (twenty feet) between
the elbows.
Assuming you have sections of vertical pipe that are more
3.
than 10’ (ten feet) measuring between elbows, you must
insert – at midpoint – a chimney stabilizer. When installing
the stabilizer, pull out the support straps with a good amount
of tension and hammer to the frame.
If your offset sections go over 6’ (six feet) in length, you
4.
will need to give added support using a sheet metal screw
– a # 8 x ½” is recommended. The screw will be fastened
underneath the joint.
To ensure a tight t for the screw, drill a hole that is 1/8”
5.
(one-eighth inch) in diameter right at the chimney joint’s
underside. Be sure that you position the drill at the very
center of where the joint overlaps. Be very careful not to
drill through the inner casting; drill only through the outer
chimney.
Maximum offset is 30 degrees off of vertical and there
•
should be no more than one offset sequence per chimney
system.
Under no circumstances should two offsets be attached to
•
comprise a 60 degree offset conguration.
Always maintain at least 2” (two inches) of clearance around
•
all offset installation for air space and necessary clearance
from combustibles.
Working with Floors and Ceilings
If your offset chimney installation passes through a oor or
ceiling, you will have to use a 30 degree angle offset in which
case you are advised to use a restop spacer.
Should the length of the chimney below the oor or ceiling be
less than 10’ (ten feet), support the chimney at the juncture of
the oor/ceiling with a stabilizer.
As in all phases of chimney component installation, you will
want to be sure you are making allowances at every juncture for
the 2” (two inch) clearance space from combustibles.
Background Information on Offset Installation
Installing Vent Plate and Chimney System
Before installing your B-Vent to the Burntech® Firebox you
must install a steel vent plate. The vent plate mudt be installed
in the vertical (open) position on the outside of the vent pipe
and is designed to close-off the chimney in the event the pipe
is removed or fails, thus alerting the operator of a problem.
Next, attach the masonry anchor plate (supplied). The
anchor plate is pre-drilled with holes for four (4) cement wedgeanchors.
Place the plate and mark the top of the rebox. Then remove
1.
the plate to carefully pre-drill holes for the wedge anchors.
Using the supplied vent plate, apply a 1/4” (one quarter
2.
inch) bead of gasket cement around the base damper lead
pipe. Apply ceramic rope gasket on to the gasket cement.
Apply balance of gasket cement in a 1/4” (one quarter
3.
inch) bead on top of smoke dome top approx. 3” (3 inches)
outside of outlet hole. Install damper on top of unit pressing
damper into cement. Attach using four (4) #8 cement
wedge-anchors.
When obstructions are present, it will be necessary to
1.
offset sections of the chimney using the 30 degree offset
component and, for every offset component, two elbow
components.
15
Venting Installation
A “B-type” venting system must be connected to the appliance
for venting to outside of building. The following section is
provided as a guide to a standard B-type vent installation.
Standing codes requirements concerning B-type vent
installations may vary within your state, province or local codes
jurisdiction. Therefore, it is recommended that you check with
your local building codes for specic requirements or in absence
of local codes, follow Section 7.0 of the current National Fuel
Gas Code ANSI Z223.1/NFPA 54 for Category I systems using
double wall B-1 vent pipe.
This gas appliance must be vented to the outdoors only
and may not be terminated into an attic space or into a chimney
ue servicing a solid fuel burning appliance.
This appliance may be vented through a manufactured
chimney system or a masonry chimney using a B-vent adapter
or a chimney liner system if the system is listed, inspected
and approved by local codes and/or building authorities. The
examples shown in Fig. 2 are typical of most B-vent installations
and codes practices.
Example 1: Shows the minimum allowable system height and
lateral offset for an inclination of 60° or greater.
Code species that offsets of 60° or greater are considered
horizontal and must follow the 75% rule for lateral to total vertical
system height.
Codes also allows only one offset in the total system when
at 60° or greater.
The total vertical height in this example represents the
minimum height of 8 ft. and therefore the allowable lateral is 6
ft. when the 75% rule applies.
If the lateral length must exceed 75% then the system must
be sized in accordance with the Category I venting tables.
Example 2: Shows a multiple offset each at a 45° inclination.
Multiple offsets are permitted if they do not exceed a 45°
inclination. The total lengths of the two offsets are not required
to meet the 75% allowable rule.
Example 3: Shows a single offset at 45° of inclination and
therefore the lateral length at 10 ft. of offset does not have to
meet the 75% rule.
In each case the offsets must be supported and restops
must be positioned wherever the vent must pass through a suboor, ceiling joist or an attic overhang.
The vent pipe must terminate vertically into a listed type
vent cap and extend a sufcient height through an approved
roof ashing, roof jack or a roof thimble. At all points the listed
clearances must be maintained.
Vent terminations must be located in accordance with
height and proximity rules of NFPA No. 54.
These rules apply to vents at 12” diameter or less and
require a minimum height in accordance with the roof pitch and
a minimum of 8 ft. distance from a vertical wall or obstruction
(see Fig. 3).
If venting horizontally through a side wall becomes
necessary, a listed thimble approved for use with B-type vent
must be used. Check with your local codes before venting
through a side wall.
Some codes areas allow the use of existing B-type vent
systems if the system is at or above the recommended diameter
of the ue.
The ue connection must be made using listed B-type
connectors and the existing system must be code inspected for
damage and proper installation.
It is not recommended that this appliance be common
vented with an existing gas burning appliance. However, if it
becomes necessary to common vent this appliance, the venting
system must be sized and congured in accordance with the
common venting guides Appendix G of the current National
Fuel Gas Code NFPA No. 54/ANSI Z223.1.
Note: Before connecting this appliance to an existing vent
system or a common venting system, consult with your local
architect, planner, or building ofcial.
Figure 2
16
Specifying Chimney Heights
If the horizontal distance from the mid-point of the chimney
to the peak of the roof ridge is less than 10 feet, the top of the
chimney must be at least 2 feet above the roof ridge. This is
called the “2 foot in 10 foot” rule.
If the horizontal distance from the chimney’s center
measured across to the ridge of the roof is more than 10 feet,
the top of the chimney still needs to be at least 2 feet above a
point measured from a distance of 10 feet horizontally along
the roof.
Figure 3
Chimney Termination Units
You will be installing at or possibly near the top of the
chimney chase ashing. A top termination unit is the essential
piece of equipment in keeping sparks out of the atmosphere.
Before installing this important piece of equipment, you will have
to make a judgment call as to whether or not the termination
unit – like all the other exterior exposed chimney components,
for that matter – should be painted in order to protect it/them
from rusting and weathering. Particularly if you are installing
the replace and chimney near water or in a high humidity area,
the manufacturer recommends a top quality, rust-proof paint
especially formulated for metal. Follow the paint manufacturer’s
directions, applying the paint well before you are scheduled to
install the round top termination unit or any of the ashings or
ues that will be exposed to outside weather conditions.
Venting terminals shall not be recessed into walls or siding.
This appliance, when installed, must be electrically grounded
in accordance with local codes and in the absence of local
codes, with the National Electrical Code, ANSI NFPA 70, or the
Canadian Electrical Code, CSA C22.1.
Important Pre-installation Information
Before you begin, review the information and safeguards
below regarding the installation and operation of the gas
Fireplace.
This replace may only be connected to the gas supply
listed on the label. Never use propane gas in a gas replace
designed for natural gas or natural gas in a gas replace
designed for use with propane gas.
Though there are many congurations in meeting these
requirements, chimney height cannot be less than 3 feet above
the roof at the edge of the chimney.
If the roof is at, the chimney must extend no less than 3
feet from where it intersects the roof. If the chimney is entering
the roof at an angle, measure the shorter angle where the
chimney intersects the roof which should be at least 3 feet.
Note: The previous guidelines do not take into consideration
outside conditions which may require a higher chimney due
to foliage, other buildings, power lines and weather conditions
in your area. Follow the chimney manufacturer’s installation
guide for further information.
*Nominal BTU based on gas inlet pressure. Nominal gas inlet
pressure for natural gas is 5” W.C.
The gas replace must be installed by an BURNTECH
Certied or other qualied professional installer. The installation,
including provisions for combustion and ventilation air, must
conform
with the latest edition of the National Fuel Gas Code, ANSI
Z223.1, and NFPA54.
The fireplace must have a gas supply line that has
been installed by a qualified technician in accordance with
all local codes.
The gas supply line must be 1/2” minimum interior diameter. If
the gas line to the replace is longer than 5’, a larger diameter
line may be necessary.
GML-24-01(N)(P)6028/48 47/56
WARNING: THIS FIREPLACE IS DESIGNED FOR USE ONLY
WITH THE ANSI Z21.50 DECORATIVE GAS LOGS AND
BURNER TESTED AND APPROVED FOR THIS FIREPLACE.
Any change or alteration in burners or log sets must be
approved by Burntech in writing or warranty will be void.
BTU's can never exceed more than 65,000 on Models GBVS
39 and 44 and 80,000 btu's on Model GBVS 49. Unapproved
changes or alterations could result in a fire or explosion
resulting in property damage, personal injury or death.
with local codes, or, in the absence of local codes,
BURNTECH
Supplied
Burner P/N
GML-30-01N9019/41
GML-30-01P8440/55
BTU*
x 1000
Orice Drill
Size
(top/front)
NatLP
Fireplace
Model #
GBVS-39 or
-44
GBVS-49
17
Figure 27
Vent Plate Installation
Figure 28
Figure 29
Figure 30
Attention: Clearance to combustible construction can not be
reduced during course of construction. For the safe operation of
the nished replace, these clearances must be followed when
building the framework to house the chimney system.
Installing the valve/control box assembly
1.
Fasten the valve/control box assembly to a stud such that
the control switch is facing in the desired direction and
ush with the future location of the nished wall or other
enclosure.
2.
Install the two ‘D’ batteries into the battery holder within the
control box.
3.
Run the wires for the spill switch through the small hole
in the upper wall. Important: This control box must remain
accessible and removable for service after installation.
Installing Spill Switch and Bafe assembly
Connect the blade connectors on the spill switch wires to
1.
the matching wires from the valve/ control box assembly
coming through the upper hole in the rebox.
Center the black steel bafe with the spill switch sensor
2.
pointed toward the room (out of the replace).
Use six (6) drywalls screws to fasten it in place on the front-
3.
most part of the rebox ceiling as shown through the six (6)
pre-drilled holes.
Attach the trim plates to the left and right side of the bafe
4.
with the sheet metal screws so that the edges are ush with
the rebrick.
Important: This bafe assembly and only this one supplied
with the kit (with spill switch) must be properly installed for the
safe operation of this gas replace.
Trim
plate
Spillover
switch
Trim
plate
Spill sensor
wires to
valve/
control box
Owner’s Operation & Precautions
Installers of the Burntech® are urged to call the attention of
replace owners to the following precautions.
The installer should hand-deliver this owner’s manual to the
owner or leave behind with the unit after it the installation is
complete.
Warning: Use only the included replace grate or manufacturer
approved replacement.
Warning: Do not attempt to operate your replace without a re
safety screen installed.
CAUTION: Use only approved gas log sets. Never use
chemical chimney cleaners. Never burn solid fuel in this
fireplace under any circumstance.
18
First Lighting of the Burntech® – After construction is
O
U
T
I
N
P
I
L
O
T
I
N
1.
completed, all elements of the replace and chimney system
must be completely dry. This means that the unit must stand
without any ring for a minimum of 28 days. Only after that
period of time can a rst lighting take place. Do not let the re
burn for more than one hour. After this rst lighting – when
the replace has started to “cure” Do not set another re for
at least 24 hours.
Second Lighting – With the second lighting you can let the
2.
re burn two hours – no more.
After First and Second Lighting – When the replace has
3.
been properly cured with careful “maiden” rings, you will be
able to run the burner for as long as you like.
Attaching the Burner and the Grate (Burntech Burner Only)
Unpack the burner assembly and place the rear legs of
1.
the burner into the brackets in the back of the rebox (see
Figure 23).
Thread the pilot lines from the burner pilot assembly and
2.
through the hole in the lower side of the rewall to the valve/
control box assembly and attach to the valve.
Connect the supplied ex connector from the output of the
3.
valve, through the hole and to the burner.
Connect the second ex connector from the input of the
4.
valve to the gas stub down stream from the required
manual shut-off valve.
Note: The required 1/8” NPT up stream pressure tap is built
into the valve (Figure 33).
CAUTION: CHECK ALL CONNECTIONS FOR GAS LEAKS
USING A HALF-AND-HALF SOAPY WATER SOLUTION.
IF A LEAK IS DETECTED TIGHTEN CONNECTIONS AND
TEST AGAIN.
NEVER USE AN OPEN FLAME TO CHECK FOR GAS
LEAKS.
Keep the fireplace area clear and free from combustible
materials, gasoline, and other flammable vapors and liquids.
Insert a one-way screw into the hole in the front of each
5.
bracket and tighten with a long (min. 12”) screw driver until
contact is made with the grate leg and the grate is permanently
locked in place (see Figure 23).
IMPORTANT: Once installed the burner cannot be
removed.
Fill in the holes you have drilled around the gas piping with
6.
the regular Burntech® mortar.
Checking and Adjusting the Pilot (Burntech burner only)
Follow the lighting instructions to light the pilot. The pilot
1.
ame should encircle the generator tip which is preset at the
factory (Figure 32). Ordinarily, the pilot will not require eld
adjustment.
If adjustment is necessary, remove the cap screw (Figure
2.
32) and turn the smaller gas adjustment screw inside
counterclockwise to increase the pilot ame and clockwise
to decrease the pilot ame. Replace cap screw.
Figure 31
Figure 33
Figure 32
Pilot
Flame
Electrodes
Figure 34
Open
Note: This burner system is equipped with an APK-01 valve
assembly.
Placing the Decorative Lava Rock
If desired, open the bag of lava rock and pour its contents around
the base of the grating in an attractive pattern. Do not place the
Lava Rock on the logs or grate.
Adjusting Air Mixers
Burners are equipped with air mixers for the top and front burners.
Adjust the size and color of the ame by opening (turn outward)
or closing (turn inward) as shown in Figure 33, 34.
19
Log Placement (Burntech log Set Only)
Figure 35
Start with the grate/burner assembly in place
Figure 37
1
11
Place front bottom log
GML-24 shown
Figure 36
Figure 38
10
Place back bottom log
9
Place back top logs (#8 and #9)
8
Figure 39
7
Place front top log (#7)All logs in place
Placing the Logs
Place the back bottom log on the grate behind the top burner
1.
and as far forward (against the top burner) as possible
without touching the pilot. The at side should be down and
the heat chambers facing the back of the replace (Figure
35).
Place the front log on the grate in front of the top burner
2.
pipe with the at down and the heat chambers toward the
burner pipe and the log as far forward as possible while
keeping the back parallel with the burner pipe (Figure 36).
Place top logs across the front and back logs in the order
3.
and positions shown in Figure 40.
Figure 40
9
6
7
WARNING
Failure to position the parts in
accordance with these diagrams or
failure to use only parts specifically
approved with this appliance may result
in property damage or personal injury.
For Owner supplied Log Sets, follow
manufactures instruction while
referencing Burntech Instructions
8
20
O
U
T
I
N
P
I
L
O
T
I
N
Lighting and Operating Instructions (Burntech supplied burner only)
FOR YOUR SAFETY, READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a re or explosion may result causing property
damage, personal injury or loss of life.
Do not use this gas replace if any part has been underwater. Immediately call for a qualied professional service technician to
inspect the replace and to replace any part of the control system and any gas control which has been under water.
The Burntech® burner system has a pilot which can be lit by hand using a match or lighter. When lighting the pilot, follow these
instructions exactly.
BEFORE LIGHTING, smell all around the burner area for gas. Be sure to smell next to the oor as some gas is heavier than air
and will settle on the oor. IF YOU SMELL GAS, FOLLOW THE INSTRUCTIONS ON THE COVER (P. 1).
TO LIGHT THE FIREPLACE WITH THE WALL
SWITCH
Move the ON-REMOTE-OFF wall switch to the ON position
(Figure 41). This transmits a rapid series of sparks at the pilot
head and will ignite the gas.
TO SHUT DOWN THE GAS FIREPLACE USING THE WALL
SWITCH
Move the switch to the OFF position (Figure 41). The gas ow
will cease, and all ames (main burner and pilot) will go out (see
important note below).
OPERATING THE BURNER USING THE REMOTE
Move the wall switch to the REMOTE position and follow the
instructions included in the remote kit for lighting and shutting
down the attached burner.
IMPORTANT: Do not allow the replace opening to be
blocked in any way while operating the replace. The
replace may be operated with a Burntech® screen installed
and drawn.
MAINTAINING THE PILOT
Your gas replace is equipped with a safety pilot that will shut
off the gas supply in case the pilot is not burning or functioning
properly. Regularly verify that the pilot is adjusted properly with
the pilot ame hitting the electrodes as shown in Figure 42. If the
pilot will not stay lit, call your local gas utility or gas supplier.
TO CHECK UPSTREAM GAS PRESSURE
Unscrew the four (4) screws above and below the control panel
face, then pull the control panel out far enough to expose the
test ports on the valve (Figure 41). Unscrew the port marked IN
part way and test.
CAUTION: Do not kink the ex connectors coming from the
valve while accessing it.
Figure 42
Lighting
the Pilot
Figure 41
Upstream gas
pressure tap
Warning: BURNTECH accepts no responsibility
for log sets and burners provided by installer or
customer.
Note: Pilot ame should encircle top of electrodes.
See instructions cover for example of proper main burner ame
pattern.
ON
REMOTE
OFF
Figure 43
21
Maintenance and Service
Maintenance
Once installed and operating properly, the Burntech® gas
replace requires very little maintenance.
You should inspect the replace, chimney, burner and control
annually for the following:
Excessive Sooting - Some sooting of the logs is normal
1.
and adds to the natural appearance of burned wood. If soot
accumulates, you may brush the soot off with a stiff brush.
Logs may also be cleaned by allowing them to heat up, then
spraying them with water where soot has accumulated.
Debris around the control - Inspect the control and pilot to
2.
be sure it is free of any dirt or debris.
Insects and burner blockage - Check the burner ports
3.
and the air-mixer, if present, to make sure they are free
from debris. Blocked burner ports and orices may
result in poor ame distribution or ame at air mixer (if
equipped). Reference SOLUTION, to symptoms 2-4, of
Troubleshooting.
Troubleshooting
PROBLEMCAUSESOLUTION
a. Pilot generator may not be producing
sufcient millivolts.
b. Pilot ame making a blowing soundb. Pilot needs adjusting (see “Checking and
Pilot will NOT stay lit.1.
2. Pilot Burning.
No Gas to Burner.
3. Fireplace Not burning
properly.
4. Fireplace will not shut
OFF.
5. Frequent pilot outage.
6. Fireplace shuts down
during operation.
7. Excessive soot on logs.
c. Generator wire leads attached to the
wrong terminals on the valve.
d. Defective thermo-magnetic safety in
valve.
a. Safety valve not turned to the ON position
after lighting pilot.
b. Wire leads are not properly connected to
valve or switch terminals.
c. Voltage to pilot generator too low.c.See section 1a above.
d. Defective valve.d. Replace valve.
a. Low ame/uneven ame.a. Check for low gas pressure; minimum
a. Control Switch lead wires to the valve
may be shorted together or on wrong
terminals.
a. Pilot ame is out of adjustment.a. See section 1b above.
b. Down drafts from the chimney,
extinguishing the pilot.
a. Improper venting causing spill switch to
trip repeatedly.
b. Spill switch improperly mounted.b. See section on “Installing Spill Switch and
c. Smoke Diverter not in place.c. Install Smoke Diverter with Spill Switch per
a. Yellow ame impingement.a. Open air shutter on front burner or main
Service
It is recommended that a qualied professional service
technician be called to service the gas replace and its venting
system at least annually or should service be required. More
frequent cleaning may be required due to excessive lint from
carpeting, bedding material, etc.
It is imperative that control compartments, burners and
circulating air passageways of the appliance be kept clean.
The Troubleshooting section of these instructions serves as a
guide for ensuring optimum performance of the gas replace.
Flame Appearance
The ames should be blue at the base and a combination of
blue/yellow at the body and tips.
a. Check with a millivolt meter. Should be 250
millivolts or more.
Adjusting the Pilot” on page 22).
c. Connect leads per wiring diagram, previous
page.
d. Replace valve.
a. Turn to ON position.
b. Attach all wire leads tightly to proper terminals
(See wiring diagram, previous page).
operating pressures of 5” W.C. at manifold.
a. See wiring diagram, previous page. System
takes 15-20 seconds to complete shutdown
(nominal).
b. Check draft. Consult with a qualied chimney
expert.
a. Check draft. Consult with a qualied chimney
expert. Consider installing a combustion air
kit.
Bafe Assembly” on page 21.
instructions.
burner as needed.
22
Appendix I
For installations regulated by the International Residential Code, the support foundation for the fireplace installed on concrete shall
consist of a minimum of 6 inches thick reinforced concrete slab. The minimum specified compressive strength of
f’
c
, shall be as
required in Table R402.2 of the International Residential Code (IRC). Concrete subject to moderate or severe weathering as indicated
in Figure R301.2(3) of the International Residential Code (IRC) shall be air entrained as specified in Table R402.2 of the International
Residential Code (IRC). The maximum weight of fly ash, other pozzolans, silica fume, slag or blended cements that is included in
concrete mixtures for garage floor slabs and for exterior porches, carport slabs and steps that will be exposed to deicing chemicals
shall not exceed the percentages of the total weight of cementitious materials specified in Section 4.2.3 of ACI 318. Materials
used to
produce concrete and testing thereof shall comply with the applicable standards listed in Chapter 3 of ACI 318.
For installations regulated by the International Building Code (IBC), the support foundation for the fireplace installed on concrete
shall consist of a minimum of 6 inches thick reinforced concrete slab. The concrete strength and durability shall comply with Sections
1903, 1904 and 1905 of the International Building Code (IBC).
TABLE R402.2 MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE
MINIMUM SPECIFIED COMPRESSIVE STRENGTH
a
(f’
c
)
Weathering Potential
b
TYPE OR LOCATION OF CONCRETE CONSTRUCTION
NegligibleModerateSevere
Basement walls, foundations and other concrete not exposed to the weather2,5002,5002,500
c
Basement slabs and interior slabs on grade, except garage floor slabs 2,5002,5002,500
c
Basement walls, foundation walls, exterior walls and other vertical concrete
work exposed to the weather
2,5003,000
d
3,000
d
Porches, carport slabs and steps exposed to the weather, and garage floor slabs2,5003,000
d,e,f
3,500
d,e,f
a. Strength at 28 days psi.
b. See Figure R301.2(3) for weathering potential.
c. Concrete in these locations that may be subject to freezing and thawing during construction shall be air-entrained concrete in
accordance with Footnote d.
d. Concrete shall be air-entrained. Total air content (percent by volume of concrete) shall be not less than 5 percent or more than
7 percent.
e. See Section R402.2 for maximum cementitious materials content.
f.For garage floors with a steel troweled finish, reduction of the total air content (percent by volume of concrete) to not less than
3 percent is permitted if the specified compressive strength of the concrete is increased to not less than 4,000 psi.
23
Appendix II
FIGURE R301.2(3) WEATHERING PROBABILITY MAP FOR CONCRETE
a.Alaska and Hawaii are classified as severe and negligible, respectively.
b.Lines defining areas are approximate only. Local conditions may be more or less severe than indicated by region classification. A
severe classification is where weather conditions result in significant snowfall combined with extended periods during which there is
little or no natural thawing causing deicing salts to be used extensively.
24
Lifetime Limited Warranty
Burntech® Fireplace Solutions
Burntech® Fireplace Solutions, Inc. warrants all Burntech® Fireplaces to be free from defects in materials that adversely affect replace
performance for the lifetime of the product from the date of purchase, subject to the terms and conditions of this limited warranty. Burntech®
Fireplace Solutions does not warrant accessory chimney, outside air ducts and devices not manufactured by Burntech® Fireplace Solutions.
This warranty covers only products manufactured by Burntech® Fireplace Solutions, specically the modular masonry replace, and
NO WARRANTY, EXPRESS OR IMPLIED, EXTENDS TO ANY OF THE HARDWARE, FOUNDATION, VENTING, DUCTS,
OR ACCESSORIES. THIS WARRANTY DOES NOT COVER DRAFTING, SMOKING, OR SOOTING OF THE FIREPLACE
SYSTEM. Factors beyond the manufacturer’s control affect drafting, smoking, and sooting and Burntech® Fireplace Solutions cannot
guarantee these aspects of performance.
Coverage under this warranty is subject to the following conditions and exclusions:
This warranty is null and void when the replaces are not installed pursuant to the installation instructions provided by Burntech®
•
Fireplace Solutions or local building codes have not been followed completely.
Glass is warranted against thermal breakage only and only on models that are manufactured by Burntech® Fireplace Solutions with a glass
•
front. On Direct Vent models the safety glass or safety screen must be kept in front of this glass when replace is in use.
Safety screen must be used on all models when in use.
This warranty does not apply to any component or part that shows evidence of misuse, abuse, improper installation, accident or lack of
•
regular maintenance. Burntech® Fireplace Solutions is not responsible for misuse or mishandling of component parts.
This warranty does not apply to any damage sustained to the appliance while in transit.
•
Neither Burntech® Fireplace Solutions, nor any afliate thereof, is responsible for any labor costs or indirect costs incurred for the
•
replacement of defective components. Any covered component that, in our judgment, is defective shall be repaired, replaced or refunded
at Burntech® Fireplace Solutions’s option.
Nothing in this warranty makes Burntech® Fireplace Solutions, or any afliate thereof, liable in any respect for any injury or damage to
•
the building or structure in which the replace has been installed or to the persons or property therein arising out of the use, misuse, or
installation of properly manufactured Burntech® Fireplace Solutions products.
The replace must be used in accordance with operating instructions. The grate or andirons must be installed when using the replace.
•
NEITHER Burntech® Fireplace Solutions, NOR ANY AFFILIATE THEREOF, SHALL BE HELD LIABLE FOR ANY INCIDENTAL OR
CONSEQUENTIAL DAMAGES OR EXPENSES ARISING OUT OF THE USE OF THE FIREPLACE. ALL SUCH DAMAGES AND
EXPENSES ARE HEREBY EXCLUDED. Some states do not allow the exclusion or limitation of incidental or consequential damages, so
the above limitation or exclusion may not apply to you.
If a component is found to be defective under the terms of this warranty the party this warranty is extended shall, notify Burntech® Fireplace
Solutions, 6520 Platt Ave #577, West Hills, CA 91307 in writing, by registered mail, within thirty (30) days following the discovery of the
defect within the lifetime warranty period. The letter shall include proof of purchase and state the (1) date of purchase, model number and
serial number ; (2) place of purchase; (3) address of installation; (4) name, address and phone number of the homeowner; and (5) a brief
description of the defect.
This warranty applies only to those replaces installed in the continental United States, Alaska and Canada. If any part of this warranty is
found to be unenforceable, the remaining parts shall remain in force and effect.
THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES, TERMS OR CONDITIONS,
EXPRESS OR IMPLIED EITHER IN FACT OR BY OPERATION OF LAW. Burntech® Fireplace Solutions HEREBY DISCLAIMS ALL
GUARANTEES AND WARRANTIES, EXPRESS OR IMPLIED, BEYOND THE WARRANTIES SET FORTH HEREIN, INCLUDING
BUT NOT LIMITED TO WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not
allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.
Burntech® Fireplace Solutions
6520 Platt Ave #577, West Hills, CA 91307
Main: (818)564-4253, Fax: (818) 564-4232
Revised 12/05/2012 WWW.BURNTECH.COM
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.