Burndy YGL29C29 Data Sheet

DRAWING NO.
1234567
CATALOG NUMBER
CABLE TO CABLE
COMMERCIAL COPPER CONDUCTOR RANGE
GROOVE 'A' (ELEMENT 'A') GROOVE 'B' (ELEMENT 'B')
GROOVE 'A'
CABLE TO GROUND ROD
COMMERCIAL COPPER CONDUCTOR RANGE
GROOVE 'B' (ELEMENT 'B')
REV DATE DESCRIPTION ECO BY C'H'K.
02/08/2016 00:00:00 AM
C
B C C-C D L R
1
ADDED NOTE 10
--
42906 AS MB
(ELEMENT 'A')
#6 SOL. (.162 DIA.) - #2 STR. (.292 DIA.)
YGL2C2
[10mm2( 4.1mm) - 35mm2 ( 7.6mm)]
D D
YGL29C2
#1 STR. (.332 DIA.) - 250 kcmil (.575 DIA.)
#6 SOL (.162 DIA.) - #2 STR. (.292 DIA.)
[10mm2( 4.1mm) - 35mm2 ( 7.6mm)]
[40mm2( 8.4mm) - 120mm2 ( 14.4mm)]
-----
ROD
#6 SOL (.162 DIA.) - #2 STR. (.292 DIA.)
[10mm2( 4.1mm) - 35mm2 ( 7.6mm)]
1.09
[27.7]
1.66
1.09
[27.7]
.31
[8.0]
.31
[8.0]
1/2" - 5/8"
[42.2]
1.66
[42.2]
1.09
.50
[12.7]
.31
2.50
[63.5]
.50
[12.7]
.31
YGL29C29
#2 STR. (.292 DIA.) - 250 kcmil (.575 DIA.)
[35mm2( 7.6mm) - 120mm2 ( 14.4mm)]
#2 STR. (.292 DIA.) - 250 kcmil (.575 DIA.)
[35mm2( 7.6mm) - 120mm2 ( 14.4mm)]
#6 SOL (.162 DIA.) - #2 STR. (.292 DIA.)
[12.7 -15.9]
#2 STR. (.292 DIA.) - 250 kcmil (.575 DIA.)
[35mm2( 7.6mm) - 120mm2 ( 14.4mm)]
#6 SOL (.162 DIA.) - #2 STR. (.292 DIA.)
.75
[19.1]
YGL34C2
YGL34C29
250 kcmil (.575 DIA.) - 500 kcmil (.813 DIA.)
[120mm2 ( 14.4mm) - 240mm2 ( 20.4mm)]
[10mm2( 4.1mm) - 35mm2 ( 7.6mm)]
#2 STR. (.292 DIA.) - 250 kcmil (.575 DIA.)
[35mm2( 7.6mm) - 120mm2 ( 14.4mm)]
ROD
5/8" - 3/4"
[15.9 - 19.1]
[10mm2( 4.1mm) - 35mm2 ( 7.6mm)]
#2 STR. (.292 DIA.) - 250 kcmil (.575 DIA.)
[35mm2( 7.6mm) - 120mm2 ( 14.4mm)]
2.09
[53.1]
[27.7]
1.66
[42.2]
[8.0]
.50
[12.7]
[8.0]
.50
[12.7]
YGL34C34
C
CATALOG
NO.
Y750/Y35/Y39 HYPRESS
ELEMENT "A" ELEMENT "B"
YGL2C2 U-0 (1) U-0 (1)
YGL29C2 U997 (1) U-0 (1)
YGL29C29 U997 (1) U997 (1)
10
10
10
YGL34C2 PU998 (1) U-0 (1)
YGL34C29 PU998 (1) U997 (1)
YGL34C34 U1011 (3) U1011 (3)
L
B
2 STR
250 kcmil
DIE 997
YGL29C29
C
INSTALLATION TOOLS, DIE SET CAT. NO. (NUMBER OF CRIMPS)
TM
PAT750-18V
ELEMENT "A" ELEMENT "B"
U-0 (1) U-0 (1)
U997P (1) U-0 (1)
U997P (1) U997P (1)
PU998 (1) U-0 (1)
PU998 (1) U997P (1)
U1011 (3) U1011 (3)
CONNECTOR ELEMENT 'A'
250 kcmil (.575 DIA.) - 500 kcmil (.813 DIA.)
[120mm2 ( 14.4mm) - 240mm2 ( 20.4mm)]
Y45 HYPRESS
TM
5
ELEMENT "A" ELEMENT "B" ELEMENT "A" ELEMENT "B"
U-0 (1) U-0 (1) U-0 (1) U-0 (1)
U997 (1) U-0 (1) U997 (1) U-0 (1)
U997 (1) U997 (1) U997 (1) U997 (1)
S998 OR PU998 (1) U-0 (1) P998 OR PU998 (1) U-0 (1)
S998 OR PU998 (1) U997 (1) P998 OR PU998 (1) U997 (1)
S1011 (2) S1011 (3) P1011 (3) P1011 (3)
B
Y46 HYPRESS
TM
250 kcmil (.575 DIA.) - 500 kcmil (.813 DIA.)
[120mm2 ( 14.4mm) - 240mm2 ( 20.4mm)]
CATALOG
6
NO.
ELEMENT "A" ELEMENT "B"
1.10
[27.9]
2.28
[57.9]
CABLE TO REBAR
7
2.28
[57.9]
.75
[19.1]
2.94
[74.7]
.75
[19.1]
YGL2C2 ----- -----
#6 SOL. (.162 DIA.) - #2 STR. (.292 DIA.)
YGL29C2
YGL29C29
ROD
3/8" - 1/2"
[9.5 - 12.7]
#3 - #4 REBAR
[10mm2( 4.1mm) - 35mm2 ( 7.6mm)]
#2 STR. (.292 DIA.) - 250 kcmil (.575 DIA.)
C
[35mm2( 7.6mm) - 120mm2 ( 14.4mm)]
#6 SOL (.162 DIA.) - #2 STR. (.292 DIA.)
YGL34C2
[10mm2( 4.1mm) - 35mm2 ( 7.6mm)]
ROD
5/8" - 3/4"
#2 STR. (.292 DIA.) - 250 kcmil (.575 DIA.)
YGL34C29
[15.9 - 19.1]
[35mm2( 7.6mm) - 120mm2 ( 14.4mm)]
#5 - #6 REBAR
250 kcmil (.575 DIA.) - 500 kcmil (.813 DIA.)
YGL34C34
[120mm2 ( 14.4mm) - 240mm2 ( 20.4mm)]
ELEMENT 'A'
B
BURIAL
C-C
1
D
TYPICAL
LETTERING
CONNECTOR
ELEMENT 'B'
GROUND GRID CROSS CONNECTION
CABLE TO CABLE
NOTES:
1 BEFORE CRIMPING BOTH CONNECTOR ELEMENTS CAN BE TURNED ON ROD DIAMENTED "D" TO ANY DESIRED POSITION.
2. GROOVES ARE FILLED WITH PENETROXTM "E".
ELEMENT 'B'
TYPICAL LETTERING
1
D
2 STR
DIE 997
250 kcmil
YGL29C29
2 STR
250 kcmil
DIE 997
YGL29C29
B
BURIAL
R
B
L
B
BURIAL
L
A
REV: PE0200
3 FOR BETTER TORQUE STRENGTH ON GROUND ROD, PER CRIMP CROUND ROD WITH U2CAB DIE (DIE INDEX 348).
4. SUITABLE FOR DIRECT BURIAL IN EARTH OR CONCRETE.
5 WHERE A "U" OR "PU" DIE IS RECOMMENDED WITH THE Y45 HYPRESS
TM
, A PT6515 ADAPTER MUST BE USED.
6 WHERE A "U" OR "PU" DIE IS RECOMMENDED WITH THE Y46 HYPRESS
TM
, A PUADP-1 ADAPTER MUST BE USED.
7 CLEAN RUST AND PROTECTIVE COATINGS FROM REBAR BEFORE CONNECTOR INSTALLATION TO PROVIDE A PROPER GROUND CONNECTION, PER-CRIMPING IS NOT REQUIRED.
8. DIMENSIONS IN [ ] BRACKETS ARE IN MILIMETTERS, ROUNDED OFF TO THE NEAREST MILLIMETER, UNLESS OTHERWISE NOTED. METRIC DIMENSIONS ARE FOR REFERENCE ONLY.
9. MATERIAL: HIGH CONDUCTIVITY WROUGHT COPPER.
10 THESE CONNECTORS CAN ONLY BE INSTALLED USING THE Y750, Y45, OR Y46 HYPRESS WITH THE RECOMMENDED DIES.
TM
THESE CONNECTORS CANNOT BE INSTALLED WITH Y35 and Y39 HYPRESS .
TM
CABLE TO REBAR
OR GROUND ROD CONNECTION
ITEM NO:
CAT. NO:
DRAWN BY: C.RACANO CHECKER: C.A.R. DSN APPVL: J.HUS MFG APPVL: -­QA APPVL: -­MKT APPVL: -­PROD FAM: -- DRAWING NO REV PROJECT #: -- SIZE DOCUMENT TYPE: REL LEVEL: Released SHEET 1 OF 1
COMPRESSION GROUND CONNECTOR N/A YGL-C- (TABLE)
10/31/78 10/31/78 06/08/79
--
--
--
Sales
SD082258-01
D
A
SCALE: NTS
C
8 7 6 5 4 3 2 1
Loading...