CATALOG
NUMBER
CONDUCTOR
YE4CLH113
4 STR 4 SOL (.20)
YE4CLH114
YE2CLH128
2 STR 2 SOL (.26)
YE2CLH129
YE25LH96
1/0 STR
YE25LH97
YE26LH88
2/0 STR 2/0 SOL (.37)
YE26LH89
YE27LH90
3/0 STR 3/0 SOL (.41)
YE27LH91
YE28LH127
4/0 STR 4/0 SOL (.46)
YE28LH128
YE29LH82
250 4/0 SOL ( .46)
YE29LH83
YE30LH85
300 4/0 SOL ( .46)
YE30LH86
YE31LH96
350 4/0 SOL ( .46)
YE31LH97
YE34LH119
500 4/0 SOL ( .46)
YE34LH120
YE39LH120 750
BB
± .06
0.63
[16]
0.63
[16]
0.75
[19]
0.75
[19]
1
[25]
1
[25]
1
[25]
1
[25]
1
[25]
1
[25]
1
[25]
1
[25]
1
[25]
1
[25]
1.25
[32]
1.25
[32]
1.25
[32]
1.25
[32]
1.5
[38]
1.5
[38]
1
[25]
SHROUD
INSIDE
DIA.
± . 01
0.57
[14]
0.84
[21]
0.58
[15]
.91
[23]
.69
[18]
.98
[25]
.73
[19]
1.04
[26]
.84
[21]
1.06
[27]
.86
[22]
1.24
[31]
.88
[22]
1.25
[32]
.92
[23]
1.32
[34]
1.30
[26]
1.40
[36]
1.14
[29]
1.88
[48]
1.94
[49]
A
DIA
± . 03
1/0 SOL (.33)
4/0 SOL (.46)
L
± .150
P
± .08
8.63
[219]6[152]
9.00
[229]6[152]
11.38
[289]8[203]
11.38
[289]8[203]
11.38
[289]8[203]
11.63
[289]8[203]
11.63
[289]8[203]
12.00
[305]8[203]
12.25
[311]8[203]
13.25
[337]8[203]
13.00
[330]8[203]
BURNDY ® INSTALLATION TOOLING (# CRIMPS)
MECHANICAL
MD7, MD6
Y35, Y750
Y39
Y46 Y45 Y48B Y60BHU
HYDRAULIC
3
2
W161 (2)
OR
U4CRT ( 2) U4CRT ( 2)
U4CRT ( 2)
_ _
W162 (2)
W162 (4)
W163 (4) U25RT (2)
W241(2)
W243 (2) U27RT (2)
W-BG OR
W243 (2)
W166 (4) U29RT ( 2)
U2CRT (2) U2CRT (2) U2CRT (2)
U25RT ( 2) U25RT (2)
U26RT (2) U26RT ( 2) U26RT (2)
U26RT ( 2) U26RT (2)
U28RT (2) U28RT ( 2) U28RT (2)
U29RT (2) U29RT (2)
_ _ U30RT (2) U30RT (2) U30RT (2)
W-O (5) U31RT (2)
U31RT ( 2) U31RT (2)
_ _ U34RT (2) U34RT ( 2) U34RT (2)
_ _
_ _
_ _
_ _
_ _
_ _
C30R (1)
C31R (1)
C34R (1)
_ _ U39RT(2) U39RT(2) U39RT(2) C39R(1) L39RT(1)
_ _
_ _
_ _
_ _
_ _
_ _
_ _
L30RT ( 1)
L31RT ( 1)
L34RT ( 1)
I.D.
BB
REV DATE DESCRIPTION ECO BY C'H'K.
C
11/11/2015
L
FOCUS REQUEST FPN1511023
P
42128 AV MB
A
NOTES:
1. DIMENSIONS IN BRACKETS [ ] ARE IN MILLIMETERS ROUNDED OFF TO THE
NEAREST MILLIMETER, UNLESS OTHERWISE SPECIFIED AND ARE FOR REFERENCE ONLY.
2
CATALOG # PT-6515 ADAPTOR IS REQUIRED TO USE "U" DIES IN Y45 SERIES TOOLS.
3
CATALOG # PUADP-1 ADAPTOR IS REQUIRED TO USE " U" DIES IN Y46 SERIES TOOLS.
4. OIL AND WATER - TIGHT TERMINAL WITH SHROUDED, TIN - PLATED, COPPER BARREL AND BRAZED PLUG.
RECOMMENDED FOR TERMINATING INSULATED COPPER CONDUCTOR AT CUTOUT, TRANSFORMER AND
ARRESTOR, OR FOR JOINING INSULATED COPPER RISER TO OVER HEAD CONDUCTOR. SHROUD
PREVENTS SEEPAGE OF WATER OR MOISTURE INTO CONDUCTOR STRANDS AND MINIMIZES TAPING.
TO OBTAIN A TIGHT FIT ON SOME INSULATIONS IN THE SHROUD IT MAY BE NECESSARY TO EITHER
"PENCIL" THE INSULATION DOWN, OR BUILD IT UP WITH TAPE.
ITEM NO:
CAT. NO:
DRAWN BY:
CHECKER:
DSN APRVL:
MFG APRVL:
QA AP RVL:
MKT APRVL:
PROD FAM:
PROJECT #:
DOCUMENT TYPE:
REL LEVEL:
HYSEALPLUG (COPPER)
SEE TABLE
YE-LH (TABLE)
M.A.P
A.K.K
--
Sales
Released
1/23/1964
1/23/1964
SIZE
D
DRAWING NO
SA055640-01
SHEET 1 OF 1
REV
C