Burndy YA-L, YA-L-FX, YAV-L-FX, YAV Catalog Page

Burndy YA-L, YA-L-FX, YAV-L-FX, YAV Catalog Page

Compression Connections

Copper Compression — Flex — Inspection Window

ONE HOLE HYLUG™ C-44 FLEX CONDUCTOR

STANDARD BARREL

TYPES YA-L, YA-L-FX, YAV, YAV-L-FX

COPPER COMPRESSION TERMINAL

UL Listed 90° C, 600 Volts to 35 kV

45° and 90° angles are available.

Please contact Customer Service to order: 1-800-346-4175

DIE AND COLOR

CODE INFORMATION

INSPECTION

WINDOW

ELECTRO-TIN

PLATED

 

B

 

B

T

T

 

45°

L

L

Fig. 1

45°

BURNDY®

BEVELED

ENTRY

CRIMP

CABLE

ACCOMMODATION

B

90°

T

L

90°

 

 

Conductor

Stud

 

 

 

Figure

 

 

 

Installation Tooling

 

 

Wire

 

 

 

 

 

 

 

 

 

Mechanical

Hydraulic

 

 

 

 

 

***

Hole

Tongue

 

Dimensions

 

Dieless

MD6, OUR840,

BCT500HS,

Y35, Y39, Y750,

Color

Die

Strip

Catalog Number

Fig #

AWG

MM2

Size

Width

(B)

 

(T)

 

(L)

(# of crimps)

MD7-34R

Y500CTHS

Y46*, PAT750

Code

Index

Length

YA8CL-BOX

1

 

 

8-10

.41

.44

 

.08

 

1.16

Y1MRTC (1)

 

 

 

 

 

 

YA8C-L1-BOX

1

37/24

 

1/4

.44

.44

 

.08

 

1.26

Y8MRB-(1)

W8CVT (1)

W8CVT (1)

 

 

 

 

YA8C-L2-BOX

 

**

 

 

 

 

 

 

 

MY29-11 (1)

 

 

 

 

1

#8 Weld

5/16

.52

.44

 

.08

 

1.38

W8CRT (1)

W8CRT (1)

U8CRT (1)

Red

49

7/16

10

 

 

Y81KFT (1)

 

 

#8 AWG

 

 

 

 

 

 

 

X8CRT (1)

X8CRT (1)

 

 

 

 

YA8C-L3-BOX

1

 

3/8

.58

.44

 

.08

 

1.51

Y81KFTMBH (1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YA8C-L4-BOX

1

 

 

1/2

.71

.44

 

.08

 

1.76

PAT81KFT-18V (1)

 

 

 

 

 

 

YAV6CL-TC10-FX

1

 

 

8-10

.48

.50

 

.08

1.30

Y1MRTC (1)

 

 

 

 

 

 

YAV6CL-TC12-FX

1

61/24

 

1/2

.75

.50

 

.12

 

1.86

W5CVT (1)

W5CVT (1)

 

 

 

 

 

 

 

MY29-11 (1)

 

 

 

 

YAV6CL-TC14-FX

1

#6 Weld

**

1/4

.48

.50

 

.08

 

1.43

W5CRT (1)

W5CRT (1)

U5CRT (1)

Blue

7

1/2

 

 

Y81KFT (1)

YAV6CL-TC38-FX

1

#6 AWG

16

3/8

.60

.50

 

.06

 

1.61

X5CRT (1)

X5CRT (1)

 

 

 

 

 

 

Y81KFTMBH (1)

 

 

 

 

YAV6CL-TC516-FX

1

 

 

5/16

.60

.50

 

0.07

 

1.49

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MY29-11 (1)

 

 

 

 

 

 

 

 

61/24

**

 

 

 

 

 

 

 

Y644HS (1)

 

 

 

 

 

 

YAV6CL-TC34-FX

1

#6 Weld

16

3/4

1.05

.50

 

.13

 

2.30

Y81KFT (1)

W5CVT (1)

X5CRT (1)

U5CRT (1)

Blue

7

1/2

 

 

#6 AWG

 

 

 

 

 

 

 

 

Y81KFTMBH (1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PAT81KFT-18V (1)

 

 

 

 

 

 

YAV4CL-TC10-FX

1

91/24

 

10-8

.55

.50

 

.09

 

1.32

 

 

 

 

 

 

 

YAV4CL-TC12-FX

1

 

1/2

.71

.50

 

.07

 

1.92

 

W4CVT (1)

W4CVT (1)

 

 

 

 

105/24

 

 

 

 

 

 

 

 

YAV4CL-TC14-FX

1

1/4

.55

.50

 

.09

 

1.44

 

W4CRT (1)

W4CRT (1)

U4CRT (1)

Gray

8

1/2

#4 Weld

 

 

Y1MRTC (2)

YAV4CL-TC38-FX

1

 

3/8

.58

.50

 

.08

 

1.67

X4CRT (1)

X4CRT (1)

 

 

 

 

#4 AWG

 

 

 

MY29-11 (1)

 

 

 

 

YAV4CL-TC516-FX

1

 

5/16

.55

.50

 

.09

 

1.51

 

 

 

 

 

 

 

 

 

 

Y81KFT (1)

 

 

 

 

 

 

YAV2CL-TC10-FX

1

 

 

# 10

.68

.63

 

.10

 

1.50

 

 

 

 

 

 

125/24

 

 

 

Y81KFTMBH (1)

 

 

 

 

 

 

YAV2CL-TC12-FX

1

 

1/2

.77

.63

 

0.09

 

2.12

W2CVT (1)

W2CVT (1)

 

 

 

 

 

 

150/24

 

 

 

 

 

 

 

 

PAT81KFT-18V (1)

 

 

 

 

 

 

YAV2CL-TC14-FX

1

35

1/4

.68

.63

 

.10

 

1.62

W2CRT (1)

W2CRT (1)

U2CRT (1)

Brown

10

11/16

 

 

#2 Weld

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YAV2CL-TC38-FX

1

 

3/8

.68

.63

 

.10

 

1.81

 

X2CRT (1)

X2CRT (1)

 

 

 

 

#2 AWG

 

 

 

 

 

 

 

 

YAV2CL-TC516-FX

1

 

5/16

.68

.63

 

.10

 

1.69

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Use PUADP-1 adapter with U dies in Y46 HYPRESS™.

**The MM2 conductor size listed is for both Class 2 and Class 5 conductors.

***The MM2 conductor sizes listed are the recommendations for Class 5 conductor.

See tooling section of this catalog for complete tool and die listings. Use ONLY color-coded die recommendations for -FX connectors. For nest/indentor system contact factory.

For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instructions.

Note: All dimensions shown are for reference only.

Blue highlighted items are industry standard and most frequently ordered.

BURNDY®

Compression Connections

 

Copper Compression — Flex — Inspection Window

 

 

ONE HOLE HYLUG™ FLEX CONDUCTOR STANDARD BARREL

(Continued)

UL Listed 90° C, 600 Volts to 35 kV

 

B

 

B

 

 

 

 

B

90°

C-45

T

T

T

 

 

 

45°

 

L

L

L

 

Fig. 1

45°

90°

 

45° and 90° angles are available.

Please contact Customer Service to order: 1-800-346-4175

 

 

Conductor

Stud

 

 

 

Figure

 

 

 

Installation Tooling

 

 

Wire

 

 

 

 

 

 

 

 

 

Mechanical

Hydraulic

 

 

 

 

 

***

Hole

Tongue

 

Dimensions

 

Dieless

MD6, OUR840,

BCT500HS,

Y35, Y39, Y750,

Color

Die

Strip

Catalog Number

Fig #

AWG

MM2

Size

Width

(B)

 

(T)

 

(L)

(# of crimps)

MD7-34R

Y500CTHS

Y46*, PAT750

Code

Index

Length

YAV1CL-TC10-FX

1

175/24

 

# 10

.75

.69

 

.12

 

1.59

 

 

 

 

 

 

 

YAV1CL-TC12-FX

1

 

1/2

.75

.69

 

.12

 

2.15

 

W1CVT (1)

W1CVT (1)

 

 

 

 

225/24

 

 

 

 

 

 

 

 

YAV1CL-TC14-FX

1

1/4

75

.69

 

.12

 

1.71

 

W1CRT-1 (1)

W1CRT-1 (1)

U1CRT (1)

Green

11

11/16

#1 Weld

 

 

MY29-11 (1)

YAV1CL-TC38-FX

1

 

3/8

.75

.69

 

.12

 

1.90

X1CRT-1 (1)

X1CRT-1 (1)

 

 

 

 

#1 AWG

 

 

 

Y81KFT (1)

 

 

 

 

YAV1CL-TC516-FX

1

 

5/16

.75

.69

 

.12

 

1.78

 

 

 

 

 

 

 

 

 

 

Y81KFTMBH (1)

 

 

 

 

 

 

YAV25L-TC12-FX

1

 

 

1/2

.83

.69

 

.12

 

2.19

 

 

 

 

 

 

275/24

 

 

 

PAT81KFT-18V (1)

W25VT (2)

W25VT (2)

 

 

 

 

YAV25L-TC14-FX

1

 

1/4

.83

.69

 

.12

 

1.75

 

 

 

 

 

 

1/0 Weld

50

 

 

 

 

 

 

 

 

W25RT (2)

W25RT (2)

U25RT (1)

Pink

12

11/16

YAV25L-TC38-FX

1

3/8

.83

.69

 

.12

 

1.94

 

1/0 AWG

 

 

 

 

X25RT (2)

X25RT (2)

 

 

 

 

YAV25L-TC516-FX

1

 

5/16

.83

.69

 

.12

 

1.77

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YAV26L-TC10-FX

1

 

 

# 10

.93

.81

 

.13

 

1.80

 

 

 

 

 

 

 

YAV26L-TC12-FX

1

 

 

1/2

.93

.81

 

.13

 

2.36

 

 

 

 

 

 

 

YAV26L-TC14-FX

1

325/24

 

1/4

.93

.81

 

.13

 

1.92

 

W26VT (2)

W26VT (2)

 

 

 

 

YAV26L-TC34-FX

1

2/0 Weld

70

3/4

1.10

.81

 

.11

 

2.89

 

W26RT (2)

W26RT (2)

U26RT (1)

Black

13

13/16

YAV26L-TC38-FX

1

2/0 AWG

 

3/8

.93

.81

 

.13

 

2.11

 

X26RT (2)

X26RT (2)

 

 

 

 

YAV26L-TC516-FX

1

 

 

5/16

.93

.81

 

.13

 

1.98

 

 

 

 

 

 

 

YAV26L-TC58-FX

1

 

 

5/8

.93

.81

 

.13

 

2.61

 

 

 

 

 

 

 

YAV27L-TC10-FX

1

 

 

# 10

1.03

1.00

 

.14

 

2.03

 

 

 

 

 

 

 

YAV27L-TC12-FX

1

450/24

 

1/2

1.03

1.00

 

.14

 

2.59

 

W27VT (2)

W27VT (2)

 

 

 

 

YAV27L-TC14-FX

1

3/0 Weld

95

1/4

1.03

1.00

 

.14

 

2.15

 

W27RT (2)

W27RT (2)

U27RT (1)

Orange

14

1

YAV27L-TC38-FX

1

3/0 AWG

 

3/8

1.03

1.00

 

.14

 

2.34

 

X27RT (3)

X27RT (3)

 

 

 

 

YAV27L-TC516-FX

1

 

 

5/16

1.03

1.00

 

.14

 

2.21

 

 

 

 

 

 

 

YAV28L-TC12-FX

1

 

 

1/2

1.14

1.03

 

.15

 

2.67

MY29-11 (1)

 

 

 

 

 

 

YAV28L-TC14-FX

1

550/24

 

1/4

1.14

1.03

 

.15

 

2.23

Y644HS (1)

W28VT (2)

W28VT (2)

 

 

 

 

YAV28L-TC34-FX

1

**

3/4

1.14

1.03

 

.15

 

3.11

Y81KFT (1)

 

 

 

 

4/0 Weld

 

 

W28RT (2)

W28RT (2)

U28RT (1)

Purple

15

1-1/16

YAV28L-TC38-FX

1

120

3/8

1.14

1.03

 

.15

 

2.42

Y81KFTMBH (1)

 

 

4/0 AWG

 

 

 

 

 

 

 

 

 

X28RT (2)

X28RT (3)

 

 

 

 

YAV28L-TC516-FX

1

 

5/16

1.14

1.03

 

.15

 

2.29

PAT81KFT-18V (1)

 

 

 

 

YAV28L-TC58-FX

1

 

 

5/8

1.14

1.03

 

.15

 

2.92

 

 

 

 

 

 

 

YAV29L-TC12-FX

1

 

 

1/2

1.14

1.03

 

.16

 

2.67

 

 

 

 

 

 

 

YAV29L-TC14-FX

1

 

 

1/4

1.14

1.03

 

.16

 

2.23

 

 

 

 

 

 

 

YAV29L-TC34-FX

1

550/24

 

3/4

1.14

1.03

 

.16

 

3.11

 

 

 

 

 

 

 

YAV29L-TC38-FX

1

4/0 Weld

3/8

1.14

1.03

 

.16

 

2.42

 

 

 

 

 

 

 

YAV29L-TC516-FX

1

 

 

5/16

1.14

1.03

 

.16

 

2.29

 

W29VT (2)

W29VT (2)

 

 

 

 

YAV29L-TC58-FX

1

 

 

5/8

1.14

1.03

 

.16

 

2.92

 

W29RT (2)

U29RT (1)

Yellow

16

1-1/16

 

 

 

 

 

X29RT (4)

YA30L-TC516-FX

1

250 Flex

 

5/16

1.20

1.03

 

.16

 

2.31

 

X29RT (4)

 

 

 

 

 

 

 

 

 

 

 

 

 

YA30L-TC38-FX

1

CLASS G

 

3/8

1.20

1.03

 

.16

 

2.44

 

 

 

 

 

 

 

YA30L-TC12-FX

1

259 Str.

1/2

1.20

1.03

 

.16

 

2.69

 

 

 

 

 

 

 

YA30L-TC58-FX

1

CLASS H

 

5/8

1.20

1.03

 

.16

 

2.94

 

 

 

 

 

 

 

YA30L-TC34-FX

1

427 Str.

 

3/4

1.20

1.03

 

.16

 

3.12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Use PUADP-1 adapter with U dies in Y46 HYPRESS™

**The 16 MM2 is for both Class 2 and Class 5 conductors.

***The MM2 conductor sizes listed are the recommendations for Class 5 conductor.

See tooling section of this catalog for complete tool and die listings. Use ONLY color-coded die recommendations for -FX connectors. For nest/indentor system contact factory.

For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instructions.

Note: All dimensions shown are for reference only.

Blue highlighted items are industry standard and most frequently ordered.