Burndy YA-E Catalog Page

E-LINE HYLUG™ EQUIPMENT LINE
TYPE YA-E COPPER AND ALUMINUM COMPRESSION TERMINAL
UL Listed 90° C, 600 V
olts to 35 kV
† Installation Tooling
Conductor Accommodations
Mechanical Hydraulic
Copper Only Bolt Tongue Y35, Y750, Y46*, Wire
Catalog Fig Conventional Expanded Wire Range Bolt Hole Width
Dimensions
Dieless MD6, MD7 PAT750 Color Die Strip
Number No. Wire Size using Y644M Size Spacing (max) B T L (number of crimps) (number of crimps) (number of crimps) Code Index Length
YA25LN50T14E 1 1/4 — 0.50 0.88 0.12 1.84
Y644HS (1)
W25RT (2) U25RT (1) 12
YA25LN64T516E 1
1/0 AWG #6 - 1/0 AWG
5/16 0.64 0.88 0.12 1.96
PAT644HS (1)
W25VT (2) U2CABT (1)
Pink
348
15/16
Y81KFT (1)
YA26LN50T14E 1 2/0 AWG #4 - 2/0 AWG 1/4 0.50 0.94 0.12 1.94
Y81KFTMBH (1)
W26RT (2)
U26RT (1) Black 13 1
PAT81KFT-18V (1)
W26VT (2)
U30RT (2) 17
YA30L24N100T38E 1 300 kcmil 2/0 AWG - 300 kcmil 3/8 1.00 1.03 0.16 2.44
Y644HS (1)
W30RT (2)
U28ART (2)
White
298
1-1/16
YA342LNN119T12E 2 1/2 1.75 1.19 1.27 0.23 5.06
PAT644HS (1) U34RT (2)
YA342LNN131T12E 2 500 kcmil 4/0 AWG - 500 kcmil 1/2 1.75 1.31 1.27 0.23 5.06
Y81KFT (2)
U31ART (2) Brown
20
1-5/16
YA34L6N131T12E 1 1/2 1.31 1.27 0.23 3.31
Y81KFTMBH (2)
P34RT (2)
299
YA39L6N131T12E 1 1/2 1.31 1.42 0.27 3.61
PAT81KFT-18V (2)
YA392LNN131T12E 2
750 kcmil 500 - 750 kcmil
1/2 1.745 1.31 1.42 0.27 5.37
U39RT (2) Black 24 1-1/2
COPPER E-LINE HYLUG™ COMPRESSION TERMINALS
† Installation Tooling
Conductor Accommodations
Mechanical Hydraulic
Aluminum Copper or Aluminum Bolt Tongue Y35, Y750, Y46*, Wire
Catalog Fig Conventional Expanded Wire Range Bolt Hole Width
Dimensions
Dieless MD6, MD7, Y500CT PAT750 Color Die Strip
Number No. Wire Size using Y644M Size Spacing (max) B T L (number of crimps) (number of crimps) (number of crimps) Code Index Length
YA8CA3S56T14E 1 #8 AWG #8 AWG 1/4 0.56 0.62 0.09 1.65
Y644HS (1)
U8CABT (1) Blue 374 11/16
YA2CA5S53T14E 1 1/4 0.53 1.00 0.22 2.25
PAT644HS (1)
YA2CA1S91T516E 1
#2 AWG #6 - #2 AWG
5/16 0.91 1.12 0.16 2.50
Y81KFT (1)
U2CABT (1) Pink 348 1-3/16
YA25A1S60T516E 1 5/16 0.63 1.00 0.21 2.29
Y81KFTMBH (1)
YA25A3N69T38E 1
1/0 AWG #1 - 1/0 AWG
3/8 0.69 1.05 0.21 2.38
PAT81KFT-18V (1)
U25ART (1) Tan 296 1-1/8
YA26A13N100T516E 1 5/16 1.00 1.11 0.24 2.45 YA26A6N100T38E 1
2/0 AWG #1 - 2/0 AWG
3/8 1.00 1.11 0.24 2.53
U26ART (2) Olive 297 1-3/16
YA27A10S76T516E 1 3/0 AWG #1 - 3/0 AWG 5/16 0.76 1.11 0.26 2.58 U27ART (2) Ruby 467 1-3/16 YA28A14N100T516E 1 3/8 1.00 1.39 0.30 2.85
Y644HS (1)
YA28A1N100T38E 1
4/0 AWG 1/0 - 4/0 AWG
5/16 1.00 1.39 0.30 2.94
PAT644HS (1)
U28ART (2) White 298 1-7/16
YA30A9N100T516E 1 5/16 1.00 1.53 0.36 3.12
Y81KFT (2)
YA30A6N100T38E 1 300 kcmil 2/0 AWG - 300 kcmil 3/8 1.00 1.53 0.36 3.20
Y81KFTMBH (2)
U30ART (2) Blue 470 1-5/8
YA30A1N131T12E 1 1/2 1.31 1.53 0.35 3.57
PAT81KFT-18V (2)
YA31A11N100T516E 1 5/16 1.00 1.85 0.39 3.51 YA31A9N100T38E 1
350 kcmil 3/0 AWG - 350 kcmil
3/8 1.00 1.85 0.39 3.59
U31ART (2) Brown 299 1-7/8
YA32A8N106T516E 1 400 kcmil 4/0 AWG - 400 kcmil 5/16 1.06 2.26 0.43 3.92 U32ART (4) Green 472 2-5/16
ALUMINUM E-LINE HYLUG™ COMPRESSION TERMINALS
Fig. 1 Fig. 2
upgrading or replacing, YA-E connectors will provide for any of your cable termination needs. When installed with our dieless tool, these terminals can accommodate a range of conductor sizes.
† A variety of BURNDY®installation tools are available and
not all tools are listed. If you require additional tooling information, please feel free to call our customer service department for other recommendations.
* Use PUADP-1 adapter with U dies in Y46 HYPRESS™,
P-RT die sets for use in Y46 HYPRESS™ only. PUADP-1 adapter not required.
Note: All dimensions shown are for reference only. ** 900 Compact Aluminum Cable not UL Listed. Tested with
Y644HS and PAT644 dieless tools only.
C-80
Compression Connections BURNDY
®
Copper and Aluminum Compression — Narrow Tongue — One and Two Hole
E-LINE HYLUG™ EQUIPMENT LINE
TYPE YA-E COPPER AND ALUMINUM COMPRESSION TERMINAL
(Continued) UL Listed 90° C,
600 V
olts to 35 kV
† Installation Tooling
Conductor Accommodations
Mechanical Hydraulic
Aluminum Copper or Aluminum Bolt Tongue Y35, Y750, Y46*, Wire
Catalog Fig Conventional Expanded Wire Range Bolt Hole Width
Dimensions
Dieless MD6, MD7, Y500CT PAT750 Color Die Strip
Number No. Wire Size using Y644M Size Spacing (max) B T L (number of crimps) (number of crimps) (number of crimps) Code Index Length
YA34A8N131T38E 1 3/8 1.31 1.64 0.35 3.88 YA34A3N131T12E 2 500 kcmil 4/0 AWG - 500 kcmil 1/2 1.75 1.31 1.64 0.35 5.71 YA34A7N131T12E 1 1/2 1.31 1.64 0.35 3.88
Y644HS (2)
YA36A9N131TD12E 1 1/2 1.31 1.64 0.39 3.98
PAT644HS (2)
1-11/16
YA36A3N131TD38E 2 600 kcmil 250 - 600 kcmil 3/8 1.31 1.64 0.39 5.32
Y81KFT (2)
U34ART (4) Pink 300
YA36A3N131TD12E 2 1/2 1.75 1.31 1.64 0.39 5.71
Y81KFTMBH (2)
YA39A5N131TD12E 2 500 - 900** kcmil Aluminum 1/2 1.75 1.31 1.86 0.31 6.09
PAT81KFT-18V (2)
YA39A1N131TD12E 1
750 kcmil
500 kcmil Copper Only 1/2 1.31 1.86 0.31 4.28
1-15/16
ALUMINUM E-LINE HYLUG™ COMPRESSION TERMINALS
† A variety of BURNDY®installation tools are available and
not all tools are listed. If you require additional tooling information, please feel free to call our customer service department for other recommendations.
* Use PUADP-1 adapter with U dies in Y46 HYPRESS™,
P-RT die sets for use in Y46 HYPRESS™ only. PUADP-1 adapter not required.
Note: All dimensions shown are for reference only. ** 900 Compact Aluminum Cable not UL Listed. Tested with
Y644HS and PAT644 dieless tools only.
Fig. 1 Fig. 2
Blue highlighted items are industry standard and most frequently ordered.
C-81
BURNDY
®
Compression Connections
Copper and Aluminum Compression — Narrow Tongue — One and Two Hole