Compression Connections |
BURNDY® |
Aluminum Compression — Tin Plated — For Aluminum & Copper Conductors |
|
|
|
TYPES YA-A
C-114 AND YA-A-TN
HYLUG™
UNINSULATED ALUMINUM COMPRESSION TERMINAL FOR ALUMINUM AND COPPER CONDUCTORS
1-HOLE DESIGN
UL Listed 90° C, 600 Volts to 35 kV
Type YA-A aluminum tin-plated compression HYLUG™ terminals are dual-rated and designed for use on both aluminum and copper conductors from #12 sol. through 2000 kcmil.
They are designed for heavy duty applications to 35KV. YA-A terminals are prefilled with PENETROX®, and assembled with color-coded end caps. Available with one, two, and four-hole NEMA tongues, the aluminum HYLUG™ terminals are designed for a permanent trouble-free electrical termination.
DIE AND CRIMP |
COLOR CODED |
INFORMATION |
END CAP |
CLOSED |
|
BARREL |
|
ELECTRO-TIN |
|
PLATED |
|
CRIMP
CRIMP
CABLE
ACCOMMODATION
Features and Benefits
•Manufactured from high conductivity, wrought aluminum with heavy duty wall thickness.
Provides maximum conductivity, low resistance and ductility for an excellent combination of electrical and crimp forming properties.
•Electro-tin plated.
Provides durable long lasting corrosion resistance.
•Internally bevelled barrel.
Provides easy cable insertion.
•Meets UL486B 90° C requirements.
Provides a quality electrical dual connection.
•Connector is clearly marked with wire size, die index, color-code and the proper number and location of crimps.
Provides easy identification and tooling recommendation for a proper compression which forms a homogeneous mass resulting in an excellent electrical connection.
•Factory prefilled with PENETROX® oxide inhibiting compound.
Oxide inhibiting compound contains homogeneously suspended metallic particles to penetrate the wires’ oxides, establish electrical continuity and forms an airtight connection.
•Color-coded end caps inserted in barrel end.
Prevents foreign materials from entering and contaminating the connector prior to usage plus identifies the proper color-coded die for a reliable connection.
|
|
|
|
|
|
Dimensions |
|
|
|
Installation Tooling ▲ |
|
|
|
|||
|
|
|
No. of |
|
|
|
|
|
|
Dieless (# of crimps) |
Y35, Y39, Y750, Y46* |
▲ |
Wire |
|||
Catalog |
Code |
Stud |
Holes |
|
|
|
|
T |
Z |
Mechanical |
Hydraulic |
Die Number |
Color |
Die |
Strip |
|
Number |
Conductor • |
Size |
in Pad |
C |
D |
L |
N |
Ref. |
Min. |
Tooling |
HYPRESS™ |
(# of crimps) |
Code |
Index |
Length |
|
YA12A-TN ‡ |
12 str. |
10 |
1 |
.41 |
.50 |
1.22 |
.20 |
.08 |
.30 |
MR8-27 (1) |
— |
— |
|
— |
5/8 |
|
YA10A-TN ‡ |
10 str. |
10 |
1 |
.41 |
.50 |
1.22 |
.20 |
.08 |
.30 |
|||||||
|
|
|
|
|
|
|||||||||||
YA8CA1 |
|
10 |
|
.53 |
.60 |
1.50 |
.20 |
.09 |
.40 |
|
Y81KFT (1) |
|
|
|
|
|
YA8CA3 |
8 str. |
1/4 |
1 |
.53 |
.75 |
1.65 |
.25 |
.09 |
.50 |
|
Y81KFTMBH (1) |
U8CABT (1) |
Blue |
374 |
5/8 |
|
|
|
|
PAT81KFT-18V (1) |
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
MY29-3 (1) |
|
|
|
|
||
YA6CA1 |
|
1/4 |
|
.47 |
.75 |
1.84 |
.33 |
.14 |
.42 |
MY644M (1) |
|
|
|
|
||
|
|
MRC840AL (1) |
|
|
|
|
||||||||||
|
6 str. |
|
1 |
|
|
|
|
|
|
Y81KFT (1) |
U6CABT (1) |
Gray |
346 |
3/4 |
||
|
|
|
|
|
|
|
|
|
||||||||
YA6CA3 |
3/8 |
.65 |
1.19 |
2.28 |
.44 |
.09 |
.75 |
|
Y81KFTMBH (1) |
|||||||
|
|
|
|
|
|
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|
PAT81KFT-18V (1) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
•Contact BURNDY® for conductor, stud sizes and hole drillings not shown.
See tooling section of this catalog for complete tool and die listings.
No color code assigned.
‡ UL Listed for Aluminum only.
* Use PUADP-1 adaptor with U dies in Y46 Hypress™.
For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instructions.
Note: All dimensions shown are for reference only.
Blue highlighted items are industry standard and most frequently ordered.
BURNDY® |
Compression Connections |
|
Aluminum Compression — Tin Plated — For Aluminum & Copper Conductors |
|
|
TYPES YA-A
AND YA-A-TN
(Continued)
HYLUG™
UNINSULATED ALUMINUM COMPRESSION TERMINAL FOR ALUMINUM AND COPPER CONDUCTORS
1-HOLE DESIGN
DIE AND CRIMP |
COLOR CODED |
|
|
||
INFORMATION |
END CAP |
C-115 |
CLOSED |
|
|
BARREL |
|
|
ELECTRO-TIN |
|
|
PLATED |
|
|
CRIMP
CRIMP
AL9CU
CABLE
ACCOMMODATION
UL Listed 90° C, 600 Volts to 35 kV
|
|
|
|
|
|
Dimensions |
|
|
|
Installation Tooling ▲ |
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
Dieless (# of crimps) |
Y35, Y39, Y750, Y46* |
▲ |
Wire |
|||
Catalog |
Code |
Stud |
No. of |
|
|
|
|
T |
Z |
Mechanical |
Hydraulic |
Die Number |
Color |
Die |
Strip |
|
Number |
Conductor |
Size |
Holes in Pad |
C |
D |
L |
N |
REF. |
Min. |
Tooling |
HYPRESS™ |
(# of crimps) |
Code |
Index |
Length |
|
YA4CA1 |
|
1/4 |
|
.47 |
.75 |
2.13 |
.33 |
.18 |
.42 |
|
Y81KFT (1) |
|
|
|
|
|
YA4CA3 |
4 str. |
5/16 |
1 |
.80 |
.87 |
2.25 |
.41 |
.12 |
.46 |
MY29-3 (1) |
Y81KFTMBH (1) |
U4CABT (1) |
Green |
375 |
7/8 |
|
YA4CA6 |
3/8 |
.80 |
.94 |
2.32 |
.44 |
.12 |
.50 |
MRC840AL (1) |
PAT81KFT-18V (1) |
|||||||
|
|
|
|
|
|
|||||||||||
|
|
|
Y644HS (1) |
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
YA2CA5 |
|
1/4 |
|
.50 |
.91 |
2.25 |
.32 |
.22 |
.43 |
|
|
|
|
|
|
|
YA2CA1 |
2 str. |
5/16 |
1 |
.88 |
1.03 |
2.50 |
.41 |
.16 |
.47 |
|
|
U2CABT (1) |
Pink |
348 |
1-1/8 |
|
YA2CA3 |
|
3/8 |
|
.88 |
1.03 |
2.56 |
.44 |
.16 |
.50 |
MY29-3 (1) |
|
|
|
|
|
|
YA1CA1 |
1 str. |
3/8 |
1 |
.76 |
1.19 |
2.59 |
.44 |
.19 |
.75 |
|
U1CART (1) |
Gold |
471 |
15/16 |
||
MRC840AL (1) |
|
|||||||||||||||
YA25A1 |
|
5/16 |
|
.60 |
.87 |
2.31 |
.41 |
.21 |
.46 |
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|||||||||
YA25A3 |
1/0 str. |
3/8 |
1 |
.82 |
1.18 |
2.67 |
.63 |
.21 |
.55 |
|
|
U25ART (1) |
Tan |
296 |
1-1/16 |
|
YA25A9 |
|
1/2 |
|
1.03 |
1.34 |
2.67 |
.63 |
.17 |
.71 |
|
Y81KFT (2) |
|
|
|
|
|
YA26A6 |
2/0 str. |
3/8 |
1 |
.67 |
1.18 |
2.79 |
.44 |
.24 |
.74 |
|
Y81KFTMBH (2) |
U26ART (2) |
Olive |
297 |
1-3/8 |
|
YA26A1 |
1/2 |
1.03 |
1.36 |
3.03 |
.63 |
.20 |
.73 |
|
Y644HS (1) |
|||||||
|
|
|
|
|
|
|
||||||||||
YA27A1 |
3/0 str. |
3/8 |
1 |
.73 |
1.18 |
2.88 |
.44 |
.26 |
.74 |
MY29-3 (2) |
PAT81KFT-18V (2) |
U27ART (2) |
Ruby |
467 |
1-1/2 |
|
YA27A3 |
1/2 |
1.04 |
1.37 |
3.27 |
.63 |
.26 |
.74 |
MRC840AL (2) |
|
|||||||
|
|
|
|
|
|
|
||||||||||
YA28A1 |
4/0 str. |
3/8 |
1 |
1.17 |
1.18 |
3.26 |
.44 |
.30 |
.74 |
|
|
U28ART (2) |
White |
298 |
1-5/8 |
|
YA28A3 |
1/2 |
1.17 |
1.36 |
3.44 |
.63 |
.30 |
.73 |
|
|
|||||||
|
|
|
|
|
|
|
|
|||||||||
YA29A1 |
250 kcmil |
1/2 |
1 |
1.26 |
1.36 |
3.53 |
.63 |
.33 |
.73 |
|
|
U29ART (2) |
Red |
324 |
1-5/8 |
|
YA30A6 |
300 kcmil |
3/8 |
1 |
1.38 |
1.37 |
3.90 |
.63 |
.36 |
.74 |
— |
|
U30ART (2) |
Blue |
470 |
1-3/4 |
|
YA30A1 |
1/2 |
1.38 |
1.37 |
3.90 |
.63 |
.36 |
.74 |
|
|
|||||||
|
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
Y644HS (1) |
|
|
|
|
|
YA31A1 |
350 kcmil |
1/2 |
1 |
1.52 |
1.37 |
4.33 |
.63 |
.39 |
.74 |
— |
Y81KFT (3) |
U31ART (2) |
Brown |
299 |
2-1/8 |
|
Y81KFTMBH (3) |
||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
PAT81KFT-18V (3) |
|
|
|
|
|
YA32A1 |
400 kcmil |
5/8 |
1 |
1.62 |
1.88 |
4.92 |
.88 |
.43 |
1.00 |
|
Y644HS (1) |
U32ART (4) |
Green |
472 |
2-1/2 |
|
YA34A1 |
500 kcmil |
5/8 |
1 |
1.80 |
1.91 |
5.56 |
.88 |
.46 |
1.03 |
|
U34ART (4) |
Pink |
300 |
2-5/8 |
||
|
Y81KFT (4) |
|||||||||||||||
YA36A1 |
600 kcmil |
5/8 |
1 |
1.97 |
1.88 |
5.82 |
.88 |
.52 |
1.00 |
— |
U36ART (4) |
Black |
473 |
2-7/8 |
||
Y81KFTMBH (4) |
||||||||||||||||
YA39A1 |
700/750 kcmil |
1/2 |
1 |
2.05 |
1.34 |
5.26 |
.63 |
.43 |
.71 |
|
|
|
|
|
||
|
PAT81KFT-18V (4) |
U39ART-2 (4) |
Yellow |
936 |
2-7/8 |
|||||||||||
YA39A3 |
900 Compact AL + |
5/8 |
2.05 |
1.88 |
5.80 |
.88 |
.43 |
1.00 |
|
|||||||
|
|
|
|
|
|
|
||||||||||
YA44A1 |
1000 kcmil |
5/8 |
1 |
2.50 |
1.89 |
6.50 |
.88 |
.43 |
1.01 |
— |
|
P44ART** (4) |
Brown |
302 |
3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
•Contact BURNDY® for conductor, stud sizes and hole drillings not shown.
See tooling section of this catalog for complete tool and die listings.
Y644HS DIELESS HYPRESS™ RANGE-TAKING CAPABILITIES
The following size HYDENT™ lugs and two way splices, when crimped with the Y644HS DIELESS HYPRESS™ tool, produce the following range taking capabilities:
* |
Use PUADP-1 adaptor with U dies in Y46 Hypress™. |
not UL Listed with any tool on 900 Compact Al. |
** |
P44ART for use with Y46 HYPRESS™ only. PUADP-1 |
For applications greater than 2000 Volts consult cable |
|
adapter not required. |
manufacturer for voltage stress relief instructions. |
+ |
Tested with Y644HS and PAT644 dieless tools only and |
Note: All dimensions shown are for reference only. |
Aluminum Connectors
Standard |
Expanded |
Standard |
Expanded |
Standard |
Expanded |
Wire Size |
Wire Range |
Wire Size |
Wire Range |
Wire Size |
Wire Range |
#6 AWG |
#6 AWG |
1/0 AWG |
1/0 - #1 AWG |
250 kcmil |
250 kcmil - 1/0 AWG |
#4 AWG |
#4 - #6 AWG |
2/0 AWG |
2/0 - #1 AWG |
300 kcmil |
300 kcmil - 2.0 AWG |
#2 AWG |
#2 - #6 AWG |
3/0 AWG |
3/0 - #1 AWG |
350 kcmil |
350 kcmil - 3/0 AWG |
#1 AWG |
#1 - #2 AWG |
4/0 AWG |
4/0 - #1 AWG |
400 kcmil |
400 kcmil - 4/0 AWG |
|
|
|
|
500 kcmil |
500 kcmil - 4/0 AWG |
|
|
|
|
600 kcmil |
600 - 250 kcmil |
|
|
|
|
750 kcmil |
750 - 500 kcmil |
|
|
|
|
|
|