Burndy KS, KS-3, KSU Catalog Page

Burndy KS, KS-3, KSU Catalog Page

BURNDY® EC&M

Mechanical

TYPES KS & KS-3

SERVIT® Split Bolts

For Copper, Copperweld

Compact, high strength, high copper alloy SERVIT® split-bolt has freerunning threads and easy to grip wrench flats. Highly resistant to season cracking and corrosion, the SERVIT® provides maximum pressure and assures a secure connection on all combinations of run and tap conductors. Type KS-3 accommodates 3 maximum size conductors.

 

Copper

 

Recommended

Catalog

Range for Equal

 

Min. Tap with

Tightening

Number

Run and Tap

 

Max. Run

Torque in-lb

 

 

 

 

 

KS90

12 - 10 str.

 

16 str.

80

KS15**

10 - 8 str.

 

14 str.

 

 

KS17**

8 str. - 6 sol.

 

14 str.

 

KS17-3*

8 str. - 6 sol.

 

16 str.

165

KS20**

8 str. - 4 sol.

 

14 str.

 

 

KS20-3*

8 str. - 4 sol.

 

14 str.

 

KS22**

6 str. - 2 sol.

 

14 str.

 

KS22-3*

6 str. - 2 sol.

 

14 str.

275

KS23**

6 - 2 str.

 

14 str.

 

KS25**

4 - 1/0 str.

 

14 str.

385

KS26**

2 - 2/0 str.

 

14 str.

 

 

KS27**

1 - 3/0 str.

 

8 sol.

500

KS29**

1 str. - 250 kcmil

 

8 str.

650

KS31**

1/0 str. - 350 kcmil

 

1/0 str.

 

 

KS34**

2/0 str. - 500 kcmil

 

2/0 str.

825

KS39

4/0 str. - 750 kcmil

 

4/0 str.

1000

KS44

300 - 1000 kcmil

 

4/0 str.

1100

*Not UL Listed or CSA Certified.

**UL Rated for Direct Burial

Listed torque values are for maximum conductor combinations accommodated.

Consult UL486 tables 7-4, 7-5, 7-6 for smaller conductor combinations.

TYPE KSU

Universal SERVIT®

486A Copper only

Tin plated service connector with spacer bar for all combinations of copper, aluminum, ACSR, 6201, 5005, and steel.

 

Run

 

Tap

 

Recommended

Catalog

Copper &

Run ACSR

Copper &

Tap ACSR*

Tightening

Number

Aluminum

AAAC, 5005

Aluminum

AAC, 5005

Torque in-lb

 

 

 

 

 

 

KSU17

12 - 6 sol.

8 (6-1)

12 sol. - 6 sol.

8 (6-1)

165

KSU20

10 - 4 sol.

6 (6-1)

10 sol. - 4 sol.

6 (6-1)

 

KSU22

10 - 2 sol.

6 (6-1) -

10 sol. - 2 sol.

6 (6-1) -

 

4 (7-1)

4 (7-1)

 

 

 

 

275

KSU23

8 - 2 str.

3 (6-1) -

8 sol. - 2 str.

6 (6-1) -

 

2 (6-1)

2 (6-1)

 

 

 

 

 

KSU25

2 - 1/0 str.

3 (6-1) -

10 str. - 1/0 str.

6 (6-1) -

 

1 (6-1)

1 (6-1)

 

 

 

 

385

KSU26

2 - 2/0 str.

2 (6-1) -

8 str. - 2/0 str.

6(6-1) -

 

1/0 ( 6-1)

1/0 (6-1)

 

 

 

 

 

KSU27

1 - 3/0 str.

1 (6-1) -

8 sol. - 3/0 str.

6 (6-1) -

500

2/0 (6-1)

2/0 (6-1)

 

 

 

 

KSU29

1 str. -

2/0 (6-1) -

8 str. - 250

6( 6-1) -

 

250 kcmil

4/0 (6-1)

4/0 (6-1)

 

 

 

650

KSU31

4/0 str. -

3/0 (6-1) -

4 str. - 350

4 (6-1) -

 

350 kcmil

4/0 ( 6-1)

4/0 (6-1)

 

 

 

 

KSU34

400 -

336 (30-7) -

2 str. - 500

2 (6-1) -

825

500 kcmil

477 (18-1)

477 (18-1)

 

 

 

 

 

 

 

 

 

* Accommodates compressed conductors within conductor ranges.