USE & CARE INSTRUCTIONS for ULTRA-1 & 2 COLD DRINK DISPENSERS
NOTICE - This guide is for quick reference only and is not intended to replace the information in the Operation Manual!
DISASSEMBLY & CLEANING
Turn cooling to OFF selection. Empty all product from the hopper(s). Turn auger to OFF selection.
1. Unplug the hopper lamp cord(s)
and remove the hop per lid(s).
NOTE: On Autofill models, remove
the level probe and fill tubes from
the hopper.
6. CAUTION: Faucet valve is under
spring tension. Spread one side of
the handle first, then the other and
disconnect from hopper.
11. Place all parts in a clean sink with mild hot water (120°F) and sanitizer solution. Allow all parts to soak for at least 5 minutes. Carefully wash all components with a clean wash
cloth in the hot water and sanitizer solution. Use a clean, soft bristle brush as needed for the smaller components and tight areas. Do not immerse hopper lids. Use a commercial
sanitizer that has 100 ppm of available chlorine with a concentration level of at least 3% available chlorine (KAY-5 Sanitizer). Follow the sanitizer’s mixing instructions to ensure 100
ppm of available chlorine.
12. Wash the drum(s), hopper drip tray(s), top cover(s), and outer enclosure using a clean wash cloth that has been dampened in the hot water and sanitizer solution. Pay particular
attention to the shaft area and make sure it is thoroughly cleaned and sanitized.
13. Thoroughly rinse all surfaces with a clean wash cloth that has been dampened with hot water. Wipe dry with a clean dry wash cloth before reassembling the dispenser.
NOTE – Although most parts are dishwasher safe, they may be affected by the chemicals in some commercial sanitizing agents. Do not place the hopper nor hopper lids in a dishwasher.
Rinse thoroughly before assembly.
2. Depress the hopper lock plunger,
lift slightly.
7. Carefully slide valve up to remove
spring and faucet seal. Extra care
should be taken when handling the
seal to prevent damage.
3. Pull the hopper assembly forward
and remove.
8. Remove the auger nose bushing
from inside the front of the hopper.
NOTE: Do not scratch this surface
when cleaning. Deep scratches
could cause leakage around the
seal.
4.Pull the auger from the cooling
drum.
9. Remove the drip tray and cover.
5. Remove the hopper seal from the
flange on the cooling drum.
ASSEMBLY
1. Replace the auger nose bushing
inside the front of the hopper.
2. Install the hopper seal over the
flange at the rear of the cooling drum
as shown.
3. Align the auger shafts with the
augers. Push the augers as far as
they will go and rotate them so the
flat face of the auger shaft is aligned
with the flat face of the auger nose.
4. Install the hopper over the auger
and cooling drum and slide it into
place. Push down until the hopper
lock plunger snaps into place.
NOTE: On Autofill models, install
the level probe and fill tubes to the
hopper.
6. Set the hopper lid on the hopper
with lamp cord at the back.
7. Plug in the hopper lid lamp
cord.
12. Turn ON augers and cooling
function to desired settings.
29959.0004A 05/10 ©2010 Bunn-O-Matic Corporation
8. Position the faucet seal and the
return spring in the faucet valve.
13. Whether liquid concentrate or granulated powder, all product must be
thoroughly mixed BEFORE adding it to the hoppers.
9. Slide the faucet valve assembly
into place on the hopper.
10. Press down on the valve to
compress the spring. Position the
faucet handle over the faucet valve
one side at a time and snap into
place on the hopper.
11. Install the drip tray and cover.