To ensure you have the latest revision of the Operating Manual, or to view the Illustrated Parts
Catalog, Programming Manual, or Service Manual, please visit the Bunn-O-Matic website, at
www.bunn.com. This is absolutely FREE, and the quickest way to obtain the latest catalog and
manual updates. For Technical Service, contact Bunn-O-Matic Corporation at 1-800-286-6070.
Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows:
1) All equipment other than as specified below: 2 years parts and 1 year labor.
2) Electronic circuit and/or control boards: parts and labor for 3 years.
3) Compressors on refrigeration equipment: 5 years parts and 1 year labor.
4) Grinding burrs on coffee grinding equipment to grind coffee to meet original factory screen sieve analysis:
parts and labor for 3 years or 30,000 pounds of coffee, whichever comes first.
These warranty periods run from the date of installation BUNN warrants that the equipment manufactured by
it will be commercially free of defects in material and workmanship existing at the time of manufacture and
appearing within the applicable warranty period. This warranty does not apply to any equipment, component or
part that was not manufactured by BUNN or that, in BUNN’s judgment, has been affected by misuse, neglect,
alteration, improper installation or operation, improper maintenance or repair, damage or casualty. This warranty is
conditioned on the Buyer 1) giving BUNN prompt notice of any claim to be made under this warranty by telephone
at (217) 529-6601 or by writing to Post Office Box 3227, Springfield, Illinois 62708-3227; 2) if requested by
BUNN, shipping the defective equipment prepaid to an authorized BUNN service location; and 3) receiving prior
authorization from BUNN that the defective equipment is under warranty.
THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTY, WRITTEN OR
ORAL, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF EITHER
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. The agents, dealers or employees of BUNN
are not authorized to make modifications to this warranty or to make additional warranties that are binding on
BUNN. Accordingly, statements by such individuals, whether oral or written, do not constitute warranties and
should not be relied upon.
If BUNN determines in its sole discretion that the equipment does not conform to the warranty, BUNN, at its
exclusive option while the equipment is under warranty, shall either 1) provide at no charge replacement parts
and/or labor (during the applicable parts and labor warranty periods specified above) to repair the defective
components, provided that this repair is done by a BUNN Authorized Service Representative; or 2) shall replace
the equipment or refund the purchase price for the equipment.
THE BUYER’S REMEDY AGAINST BUNN FOR THE BREACH OF ANY OBLIGATION ARISING OUT OF THE SALE OF
THIS EQUIPMENT, WHETHER DERIVED FROM WARRANTY OR OTHERWISE, SHALL BE LIMITED, AT BUNN’S
SOLE OPTION AS SPECIFIED HEREIN, TO REPAIR, REPLACEMENT OR REFUND.
In no event shall BUNN be liable for any other damage or loss, including, but not limited to, lost profits, lost sales,
loss of use of equipment, claims of Buyer’s customers, cost of capital, cost of down time, cost of substitute
equipment, facilities or services, or any other special, incidental or consequential damages.
AutoPOD, AXIOM, BrewLOGIC, BrewMETER, Brew Better Not Bitter, BrewWISE, BrewWIZARD, BUNN Espress, BUNN
Family Gourmet, BUNN Gourmet, BUNN Pour-O-Matic, BUNN, BUNN with the stylized red line, BUNNlink, Bunn-OMatic,
Bunn-O-Matic, BUNNserve, BUNNSERVE with the stylized wrench design, Cool Froth, DBC, Dr. Brew stylized Dr. design,
Dual, Easy Pour, EasyClear, EasyGard, FlavorGard, Gourmet Ice, Gourmet Juice, High Intensity, iMIX, Infusion Series,
Intellisteam, My Café, PowerLogic, Quality Beverage Equipment Worldwide, Safety-Fresh, savemycoffee.com, Scale-Pro,
Silver Series, Single, Smart Funnel, Smart Hopper, SmartWAVE, Soft Heat, SplashGard, The Mark of Quality in Beverage
Equipment Worldwide, ThermoFresh, 392, A Partner You Can Count On, Air Brew, Air Infusion, Beverage Bar Creator, Beverage Profit Calculator, Brew better, not bitter., BUNNSource, Coffee At Its Best, Cyclonic Heating System, Digital Brewer
Control, Nothing Brews Like a BUNN, Pouring Profits, Respect Earth, Respect Earth with the stylized leaf and coffee cherry
design, Signature Series, Tea At Its Best, Phase Brew, The Horizontal Red Line, Titan, trifecta, Ultra, Velocity Brew are
either trademarks or registered trademarks of Bunn-O-Matic Corporation.
2
40563 041410
INTRODUCTION
This equipment dispenses granita-type and cold liquid drinks on demand from separate hoppers. Operating controls
Introduction
Site Preparation, Electrical Requirements
Initial Setup
Operating Controls
Using the Dispenser for Granita-Type Products
Using the Dispenser for Cold Liquid Products
Programming
Other Recommendations For Your Dispenser
Required Regular Maintenance
Recommended Daily Cleaning
Autofill Cleaning Instructions
User Notices
The dispenser is very heavy. Place it on a sturdy counter or shelf capable of supporting at least 180 lbs. It is
for indoor use only.
The dispenser must have at least six inches of space behind it. This space is needed for airflow, air filter
removal, and cleaning. A clearance of at approximately six inches is recommended between the dispenser sides
and the wall or another appliance. The dispenser performs better if not placed near any heating appliance. Leave
some space so the dispenser can be moved for cleaning.
ELECTRICAL REQUIREMENTS
CAUTION – Improper electrical installation will damage components. An electrician must provide electrical service as
specified below.
Model ULTRA-1 & 2, This dispenser has an attached cordset and requires a 2-wire, grounded, individual branch circuit
rated 120 volts ac, 15 amp, single phase, 60 Hz. The mating connector must be a NEMA 5-15R.
(Refer to the dataplate for exact electrical requirements.)
Model ULTRA-1A & 2A, This dispenser has an attached cordset and requires a 2-wire, grounded, individual branch circuit
rated 230 volts ac, 10 amp, single phase, 50 Hz. (Refer to the dataplate for exact electrical requirements.)Model ULTRA-1B & 2B, This dispenser has an attached cordset and requires a 2-wire, grounded, individual branch circuit
rated 100 volts ac, 10 amp, single phase, 50 Hz. (Refer to the dataplate for exact electrical requirements.)
NOTE – Bunn-O-Matic does not recommend the use of any extension cord with these dispensers.
CE REQUIREMENTS
• This appliance must be installed in locations where it can be overseen by trained personnel.
• For proper operation, this appliance must be installed where the temperature is between 5°C to 35°C.
• Appliance shall not be tilted more than 10° for safe operation.
• An electrician must provide electrical service as specied in conformance with all local and national codes.
• This appliance must not be cleaned by water jet.
• This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabili-
ties, or lack of experience and knowledge, unless they have been given instructions concerning use of this appliance by
a person responsible for its safety.
• Children should be supervised to ensure they do not play with the appliance.
• If the power cord is ever damaged, it must be replaced by the manufacturer or authorized service personnel with a special
cord available from the manufacturer or its authorized service personnel in order to avoid a hazard.
3
40563 040110
INITIAL SETUP
6.0”
MIN.
CAUTION – The dispenser is very heavy! Use care when lifting or moving it. Use at least two people to lift or
move the dispenser.
1. Set the dispenser on a sturdy counter top. The dispenser requires a minimum of 6.0” air clearance at the
rear of the dispenser. For optimum performance, do not let warm air from surrounding machines blow on
the ULTRA dispenser.
NOTE – The dispenser should be level or slightly lower in front for proper operation.
Remove all shipping material, including the compressor support eyebolt, the cooling drum supports, the
2.
“Do Not Lift Here” signs from the cooling drums, and the “Rinse Before Using” signs from the hopper(s).
For models without PAF (Powder Auto-Fill), proceed to step #7.
Remove the rear plastic plug
3.
from the trim strip between the
hopper drip trays and loosen the
auger motor cover screws.
6.
Plug RCA cord into ULTRA base
unit. Proceed with steps 7 thru
12.
4.
Place PAF platform assembly
on top of the motor covers and
install support rod into hole in
trim strip.
7.
Install each hopper seal over
the flange at the rear of the
cooling drums as shown.
4
5.
Tighten support rod from top
of platform. Retighten motor
cover screws.
8. Press the seals firmly into
place.
40563 110207
INITIAL SETUP (CONT.)
9.
Align the auger shaft with the
flat fin of the auger. Push the
augers as far as they will go
and rotate them so the flat fin
is facing up.
10. Install auger nose bushing into
inside front of hopper.
11. Thoroughly rinse the hoppers
and install them over the augers
and cooling drums.
12. Slide the hopper(s) into place
and push down until the hopper lock plunger snaps into
place. For models without PAF,
proceed to step 15.
15.
Set the lid(s) on the hopper(s).
Lift slightly and slide back or
front for filling.
13. For models with PAF, install
level probes into slots at top
rear of PAF hoppers.
16. Plug in the hopper lid lamp
cord(s).
14. Install PAF unit onto platform
and plug power cord into rear
of platform. Plug platform power
cord into proper outlet. (Refer
to PAF manual for water connections)(Proceed to step 17)
17. Assemble the drip tray.
5
40563 110207
OPERATING CONTROLS
ULTRA-1
There are three of these switches that will be used for the operation of the dispenser.
1
2
3
P3932
4
1. switch (upper left corner of the control pad)
This switch is the ON/OFF toggle switch which powers up the dispenser and the LCD display. When ON
the Date and Time toggle back and forth continously except during programming.
2. (upper right corner)
This is used to turn the auger motor to AUGER ON, AUGER OFF or AUGER REFILL ON. (Refill only ap-
plicable when installed)
3. (lower right corner)
This is used to turn the ice control to OFF, ICE or CHILL.
4. Hidden buttons used for Programming.
6
40563 041108
Loading...
+ 11 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.