Bunn-O-Matic 263000000 Installation Manual

Hot Water
Dispensers
Supercedes
10052.0000; 10010.0000; 10267.0000
10420.0000; 10889.0000; 39338.0000
39338.0001; 44306.0000
INSTALLATION & OPERATING GUIDE
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 FAX: (217) 529-6644
To ensure you have the latest revision of the manual or to obtain the illustrated parts catalog, please visit the Bunn-O-Matic website, at www.bunn.com. This is absolutely FREE, and the quickest way to obtain the latest catalog and manual updates. Contact Bunn-O-Matic Corporation at 1-800-286­6070 to obtain a paper copy of the required Illustrated Parts Catalog mailed via U.S. Postal Service.
46819.0001C 09/16 © 2014 BUNN-O-MATIC CORPORATION
BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTY
Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows:
1) Airpots, thermal carafes, decanters, GPR servers, iced tea/coffee dispensers, MCR/MCP/MCA single cup brewers, ther­mal servers and ThermoFresh® servers (mechanical and digital) 1 year parts and 1 year labor.
2) All other equipment - 2 years parts and 1 year labor plus added warranties as specified below: a) Electronic circuit and/or control boards - parts and labor for 3 years. b) Compressors on refrigeration equipment - 5 years parts and 1 year labor. c) Grinding burrs on coffee grinding equipment to grind coffee to meet original factory screen sieve analysis - parts and labor for 4 years or 40,000 pounds of coffee, whichever comes first.
These warranty periods run from the date of installation BUNN warrants that the equipment manufactured by it will be commercially free of defects in material and workmanship existing at the time of manufacture and appearing within the applicable warranty period. This warranty does not apply to any equipment, component or part that was not manufactured by BUNN or that, in BUNN’s judgment, has been affected by misuse, neglect, alteration, improper installation or operation, improper maintenance or repair, non periodic cleaning and descaling, equipment failures related to poor water quality, damage or casualty. In addition, the warranty does not apply to replacement of items subject to normal use including but not limited to user replaceable parts such as seals and gaskets. This warranty is conditioned on the Buyer 1) giving BUNN prompt notice of any claim to be made under this warranty by telephone at (217) 529-6601 or by writing to Post Office Box 3227, Springfield, Illinois 62708-3227; 2) if requested by BUNN, shipping the defective equipment prepaid to an authorized BUNN service location; and 3) receiving prior authorization from BUNN that the defective equipment is under warranty.
THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTY, WRITTEN OR ORAL, EX­PRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF EITHER MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. The agents, dealers or employees of BUNN are not authorized to make
modifications to this warranty or to make additional warranties that are binding on BUNN. Accordingly, statements by such individuals, whether oral or written, do not constitute warranties and should not be relied upon. If BUNN determines in its sole discretion that the equipment does not conform to the warranty, BUNN, at its exclusive op­tion while the equipment is under warranty, shall either 1) provide at no charge replacement parts and/or labor (during the applicable parts and labor warranty periods specified above) to repair the defective components, provided that this repair is done by a BUNN Authorized Service Representative; or 2) shall replace the equipment or refund the purchase price for the equipment.
THE BUYER’S REMEDY AGAINST BUNN FOR THE BREACH OF ANY OBLIGATION ARISING OUT OF THE SALE OF THIS EQUIPMENT, WHETHER DERIVED FROM WARRANTY OR OTHERWISE, SHALL BE LIMITED, AT BUNN’S SOLE OPTION AS SPECIFIED HEREIN, TO REPAIR, REPLACEMENT OR REFUND.
In no event shall BUNN be liable for any other damage or loss, including, but not limited to, lost profits, lost sales, loss of use of equipment, claims of Buyer’s customers, cost of capital, cost of down time, cost of substitute equipment, facilities or services, or any other special, incidental or consequential damages.
392, A Partner You Can Count On, Air Infusion, AutoPOD, AXIOM, BrewLOGIC, BrewMETER, Brew Better Not Bitter, Brew­WISE, BrewWIZARD, BUNN Espress, BUNN Family Gourmet, BUNN Gourmet, BUNN Pour-O-Matic, BUNN, BUNN with the stylized red line, BUNNlink, Bunn-OMatic, Bunn-O-Matic, BUNNserve, BUNNSERVE with the stylized wrench design, Cool Froth, DBC, Dr. Brew stylized Dr. design, Dual, Easy Pour, EasyClear, EasyGard, FlavorGard, Gourmet Ice, Gourmet Juice, High Intensity, iMIX, Infusion Series, Intellisteam, My Café, Phase Brew, PowerLogic, Quality Beverage Equipment Worldwide, Respect Earth, Respect Earth with the stylized leaf and coffee cherry design, Safety-Fresh, savemycoffee.com, Scale-Pro, Silver Series, Single, Smart Funnel, Smart Hopper, SmartWAVE, Soft Heat, SplashGard, The Mark of Quality in Beverage Equipment Worldwide, ThermoFresh, Titan, trifecta, TRIFECTA (sylized logo), Velocity Brew, Air Brew, Beverage Bar Creator, Beverage Profit Calculator, Brew better, not bitter., Build-A-Drink, BUNNSource, Coffee At Its Best, Cyclonic Heating System, Daypart, Digital Brewer Control, Element, Milk Texturing Fusion, Nothing Brews Like a BUNN, Picture Prompted Cleaning, Pouring Profits, Signature Series, Sure Tamp, Tea At Its Best, The Horizontal Red Line, Ultra are either trademarks or registered trademarks of Bunn-O-Matic Corporation. The commercial trifecta® brewer housing configura­tion is a trademark of Bunn-O-Matic Corporation.
2
46819.1 031314
CONTENTS
-1000 213.8 101.0 200 93.3
-500 212.9 100.5 200 93.3 0 212.0 100.0 200 93.3
500 211.1 99.5 200 93.3 1000 210.2 99.0 200 93.3 1500 209.3 98.5 200 93.3 2000 208.4 98.0 200 93.3 2500 207.4 97.4 200 93.3 3000 206.5 96.9 199 92.8 3500 205.6 96.4 198 92.2 4000 204.7 95.9 197 91.7 4500 203.8 95.4 196 91.1 5000 202.9 94.9 195 90.6 5500 201.9 94.4 195 90.6 6000 201.0 93.9 194 90.0 6500 200.1 93.4 193 89.4 7000 199.2 92.9 192 88.9 7500 198.3 92.4 191 88.3 8000 197.4 91.9 190 87.8 8500 196.5 91.4 189 87.2 9000 195.5 90.8 188 86.7 9500 194.6 90.3 187 86.1
10000 193.7 89.8 186 85.6
Brew water temperature is factory set at 200° F (93.3° C) Areas of high altitude will require lowering this tempera­ture to prevent boiling. This chart should be used as a guide when readjusting the brew water temperature.
Altitude
(Feet)
Boiling point
of water
° F ° C
Recommended
water temperature
° F ° C
WARRANTY ........................................................................................................... 2
INTRODUCTION ..................................................................................................... 3
CE & NORTH AMERICA REQUIREMENTS .............................................................. 4
USER NOTICES ...................................................................................................... 5
ELECTRICAL REQUIREMENTS ............................................................................... 6
PLUMBING REQUIREMENTS ................................................................................. 7
INITIAL SET-UP (H5E, H5X, H5-PC, H3/5 ELEMENT, H10X) .................................. 7
INITIAL SET-UP H5M, HW2, OHW ......................................................................... 8
OPERATING CONTROLS (H5-PC ONLY) ................................................................. 9
ADJUST DISPENSE VOLUME (H5-PC ONLY) ......................................................... 9
PROGRAMMING (H5E, H5X, H5-PC, H10X) ........................................................ 10
PROGRAMMING (H5 ELEMENT) ......................................................................... 12
PROGRAMMING (H3E ELEMENT) ....................................................................... 15
DRAINING THE DISPENSER ................................................................................ 18
CLEANING ............................................................................................................ 18
INTRODUCTION
WALL MOUNT & SUPPORT ................................................................................. 18
This equipment heats and dispenses water on demand for beverages and cooking purposes. It has a panel above the faucet that indicates the status of the dispenser. This equipment is for indoor use, either wall-mounted (H5E/X/PC) or on a sturdy counter or shelf.
3
46819.1 070215
CE REQUIREMENTS
• This appliance must be installed in locations where it can be overseen by trained personnel.
• For proper operation, this appliance must be installed where the temperature is between 5°C to 35°C.
• Appliance shall not be tilted more than 10° for safe operation.
• An electrician must provide electrical service as specified in conformance with all local and national codes.
• This appliance must not be cleaned by water jet.
• This appliance can be used by persons aged from 18 years and above if they have been given supervision or instruction concerning use of the appliance in a safe way and if they understand the hazards involved.
• Keep the appliance and its cord out of reach of children aged less than 18 years.
• Appliances can be used by persons 18 years and above with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
• Children under the age of 18 years should be supervised to ensure they do not play with the appliance.
• If the power cord is ever damaged, it must be replaced by the manufacturer or authorized service personnel with a special cord available from the manufacturer or its authorized service personnel in order to avoid a hazard.
• Machine must not be immersed for cleaning.
• Cleaning and user maintenance shall not be made by children unless they are older than 18 years and supervised.
• This appliance is intended to be used in household and similar applications such as: – staff kitchen areas in shops, offices and other working environments; – by clients in hotels, motels and other residential type environments; – bed and breakfast type environments.
• This appliance not intended to be used in applications such as: – farm houses;
• Access to the service areas permitted by Authorized Service personnel only.
• The A-Weighted sound pressure level is below 70 dBA.
NORTH AMERICAN REQUIREMENTS
• This appliance must be installed in locations where it can be overseen by trained personnel.
• For proper operation, this appliance must be installed where the temperature is between 41°F to 95°F (5°C to 35°C).
• Appliance shall not be tilted more than 10° for safe operation.
• An electrician must provide electrical service as specified in conformance with all local and national codes.
• This appliance must not be cleaned by pressure washer.
• This appliance can be used by persons aged from 18 years and above if they have been given supervision or instruction concerning use of the appliance in a safe way and if they understand the hazards involved.
• Keep the appliance and its cord out of reach of children aged less than 18 years.
• Appliances can be used by persons 18 years and above with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
• Children under the age of 18 years should be supervised to ensure they do not play with the appliance.
• If the power cord is ever damaged, it must be replaced by the manufacturer or authorized service personnel with a special cord available from the manufacturer or its authorized service personnel in order to avoid a hazard.
• Machine must not be immersed for cleaning.
• Cleaning and user maintenance shall not be made by children unless they are older than 18 years and supervised.
• This appliance is intended for commercial use in applications such as: – staff kitchen areas in shops, offices and other working environments; – by clients in hotel and motel lobbies and other similar types of environments;
• Access to the service areas permitted by Authorized Service personnel only.
4
46819.1 022015
USER NOTICES
International Code Council and the Food Code
this equipment must be installed with adequate backflow prevention to comply with federal, state and local codes. For models installed outside the
The notices on this dispenser should be kept in good condition. Replace unreadable or damaged labels.
NOTICE
ALL COMPONENTS ARE
200 TO 240 VOLT A.C.
Replace only with
components listed in the
accompaning literature
rated for the same
voltage
12537.0000
00824.0002 00824.0001
00833.0000
As directed in the International Plumbing Code of the
Manual of the Food and Drug Administration (FDA),
00657.0000
NOTICE
ALL COMPONENTS ARE
200 TO 240 VOLT A.C.
Replace only with
components listed in the
accompaning literature
rated for the same
voltage
12537.0000
37881.0000
U.S.A., you must comply with the applicable Plumb­ing /Sanitation Code for your area.
00656.0001
Optional Field Wiring
120 V, 15.4 A, 1850 W
1PH, 2-Wire + GND, 60HZ
29710.0017
Optional Field Wiring
120/208-240 V, 16.9 A, 4050 W
1PH, 3-Wire + GND, 60HZ
29710.0018
44025.0000 H5 Element (shown)
44025.0002 H3 Element
00831.0000
120V
00831.0000
5
120/208-240V
To reduce the risk of electric shock, do not remove or open cover. No user-serviceable parts inside.
37881.0002
12593.0000
Authorized service personnel only. Disconnect power before servicing.
46819.1 040816
ELECTRICAL REQUIREMENTS
POWER CORD
WARNING - The dispenser must be disconnected from the power source until specified in Initial Set-Up.
Refer to Data Plate on the Brewer, and local/national electrical codes to determine circuit requirements.
L1 BLACK
WHITENEUTRAL
N
L1
GREEN
G
POWER CORD
N BLUE NEUTRAL BLUE
L1 BROWN
L1 BROWN
N
L1
GREEN/YELLOW
G
220-240 volt ac (A)models
Note: This electrical service con­sists of 2 current carrying conduc­tors (L1 and Neutral) and a separate conductor for earth ground.
WHITE
NEUTRAL L1 BLACK
120 volt ac models
Note: This electrical service con­sists of 2 current carrying conduc­tors (L1 and Neutral) and a separate conductor for earth ground.
Electrical Hook-Up CAUTION – Improper electrical installation will damage
electronic components.
1. An electrician must provide electrical service as specified.
2. Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.
3. Turn off master switch (if equipped).
4. Remove the upper and lower rear panels.
5. Install the proper electrical wiring to the terminal block.
6. Connect the dispenser to the power source and verify the voltage at the terminal block before proceeding. Reinstall both rear panels.
7. If plumbing is to be hooked-up later be sure the dispenser is disconnected from the power source. If Plumbing has been hooked-up, the dispenser is ready for Initial Set-Up.
POWER CORD
L2 RED L2 RED
L1 BLACK
L1 BLACK
L2
L1
GREEN
G
POWER CORD
208 & 240 volt ac models
Note: This electrical service consists of 2 current carrying conductors (L1 and L2) and a separate conductor for earth ground.
L2 RED L2 RED
WHITE
NEUTRAL L1 BLACK
L1 BLACK
L2
WHITENEUTRAL
N
L1
GREEN
G
120/208 & 120/240V ac
single phase models
Note: This electrical service consists of 3 current carrying conductors (Neutral, L1 and L2) and a separate conductor for earth ground.
DUAL VOLT TOGGLE SWITCH
6
46819.1 090916
Loading...
+ 12 hidden pages