Bunn Coffee Maker ST Installation Manual

BUNN
®
S,SA
STF,STFA
DISCONTINUED VERSION
The information in this manual
is no longer current.
OPERATING & SERVICE MANUAL
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 FAX: (217) 529-6644
29251.0000G 04/01 ©1998 Bunn-O-Matic Corporation
www.bunnomatic.com
WARRANTY
Bunn-O-Matic Corp. (“Bunn”) warrants the equipment manufactured by it to be commercially free from defects in material and workmanship existing at the time of manufacture and appearing within one year from the date of installation. In addition:
1.) Bunn warrants electronic circuit and/or control boards to be commercially free from defects in material and
workmanship for three years from the date of installation.
2.) Bunn warrants the compressor on refrigeration equipment to be commercially free from defects in material
and workmanship for two years from the date of installation.
3.) Bunn warrants that the grinding burrs on coffee grinding equipment will grind coffee to meet original factory
screen sieve analysis for three years from date of installation or for 30,000 pounds of coffee, whichever comes first.
This warranty does not apply to any equipment, component or part that was not manufactured by Bunn or that, in Bunn’s judgement, has been affected by misuse, neglect, alteration, improper installation or operation, improper maintenance or repair, damage or casualty.
THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTY, WRITTEN OR ORAL, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF EITHER MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. The agents, dealers or employees of Bunn are
not authorized to make modifications to this warranty or to make additional warranties that are binding on Bunn. Accordingly, statements by such individuals, whether oral or written, do not constitute warranties and should not be relied upon.
The Buyer shall give Bunn prompt notice of any claim to be made under this warranty by telephone at (217) 529-6601 or by writing to Post Office Box 3227, Springfield, Illinois, 62708-3227. If requested by Bunn, the Buyer shall ship the defective equipment prepaid to an authorized Bunn service location. If Bunn determines, in its sole discretion, that the equipment does not conform to the warranty, Bunn shall repair the equipment with no charge for parts during the warranty period and no charge for labor by a Bunn Authorized Service Representative during the warranty period. If Bunn determines that repair is not feasible, Bunn shall, at its sole option, replace the equipment or refund the purchase price for the equipment.
THE BUYER’S REMEDY AGAINST BUNN FOR THE BREACH OF ANY OBLIGATION ARISING OUT OF THE SALE OF THIS EQUIPMENT, WHETHER DERIVED FROM WARRANTY OR OTHERWISE, SHALL BE LIMITED, AS SPECIFIED HEREIN, TO REPAIR OR, AT BUNN’S SOLE OPTION, REPLACEMENT OR REFUND.
In no event shall Bunn be liable for any other damage or loss, including, but not limited to, lost profits, lost sales, loss of use of equipment, claims of Buyer’s customers, cost of capital, cost of down time, cost of substitute equipment, facilities or services, or any other special, incidental or consequential damages.
#00831.0000
USER NOTICES
Page 2
#00658.0000
29251 042301
USER NOTICES (Continued)
#00656.0000
#00882.0000
#02763.0000
#02765.0000
#02769.0000
Page 3
29251 101598
ELECTRICAL REQUIREMENTS
CAUTION - The brewer must be disconnected from the power source until specified in
Model 15 has an attached cordset and requires 2-wire grounded service rated 120 volts ac, 15 amp, single
phase, 60 Hz.
Initial Set-Up.
WHITE
NEUTRAL L1 BLACK
120V.A.C.
P2185
Model 20 requires 2­wire, grounded service rated 120 volts ac, 20 amp, single phase, 60 Hz. Proceed as follows:
L2 RED
WHITE
NEUTRAL
L1 BLACK
120V A.C.
120V A.C.
208 or
240V.A.C.
P1841
Model 35 requires 3-
wire, grounded service rated 120/208 or 120/240 volts ac, 20 amp, single phase, 60 Hz. Proceed as follows:
P2193
“A" & "B” models re-
quire 2-wire, grounded service rated 200 volts ac or 240 volts ac, 20 amp, single phase, 50 Hz. Pro­ceed as follows:
WHITE
NEUTRAL L1 BLACK
100V.A.C.
P2185
"SDB” model requires
2-wire, grounded service rated 100 volts ac, 20 amp, single phase, 50 Hz. Proceed as follows:
Electrical Hook-Up CAUTION – Improper electrical installation will damage electronic components.
1. An electrician must provide electrical service as specified.
2. Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.
3. Before electrically connecting the brewer, remove the front and rear panel and rotate the thermostat knob fully
counterclockwise to the "OFF" position. Keep this knob in the "OFF" position until performing the "Initial Set-Up"
4. Feed the power cord through the strain relief and connect it to the terminal block.
5. Connect the brewer to the power source and verify the voltage at the terminal block before proceeding.
(Models S and ST-15 have cord attached. Replace all panels.
6. If plumbing is to be hooked-up later be sure the brewer is disconnected from the power source. If plumbing
has been hooked-up, the brewer is ready for "Initial Set-Up".
NOTE: Schematic wiring diagrams are included in this manual.
PLUMBING REQUIREMENTS
Models S & SA:
These models are completely portable and require no attached plumbing.
Models ST, STA, STF & STFA
These brewers must be connected to a cold water system with operating pressure between 20 and 90 psi (138 and 620 kPa) from a 1⁄2" or larger supply line. A shut-off valve should be installed in the line before the brewer. Install a regulator in the line when pressure is greater than 90 psi (620 kPa) to reduce it to 50 psi (345 kPa). The water inlet fitting is 1⁄4" flare.
NOTE - Bunn-O-Matic recommends 1⁄4" copper tubing for installations of less than 25 feet and 3⁄8" for more than 25 feet from the 1⁄2" water supply line. A tight coil of copper tubing in the water line will facilitate moving the brewer to clean the countertop. Bunn-O-Matic does not recommend the use of a saddle valve to install the brewer. The size and shape of the hole made in the supply line by this type of device may restrict water flow.
This equipment must be installed to comply with the Basic Plumbing Code of the Building Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the Food and Drug Administration (FDA).
Page 4
29251 011800
INITIAL SET-UP
CAUTION - The brewer must be disconnected from the power source throughout the initial set-up, except when
specified in the instructions.
1. Insert an empty funnel into the funnel rails.
2. Place an empty dispenser under the funnel.
3. Remove the front or rear panel and turn the thermostat knob to the “OFF” position and connect the brewer to the power source.
4. Fill the tank with water as directed:
4A. Models S & SA:
Pour three pitchers of tap water into the screened area on top of the brewer. Allow approximately two minutes between pitchers for water to flow into the tank. While the third pitcher of water is entering the tank, the tank will fill to capacity and the excess will flow from the sprayhead, out of the funnel, and into the dispenser.
4B. Models ST, STA:
Connect the brewer to the power source, place the "ON/OFF" switch in the "ON" upper position, and momentarily press and release the start switch. Water will begin flowing into the tank. When water stops flowing into the tank, initiate a second and a third brew cycle. During the third brew cycle the tank will fill to its capacity and the excess will flow from the sprayhead, out of the funnel, and into the dispenser.
4C. Models STF & STFA
Brewers will fill automatically when lower ON/OFF switch is placed in the "ON" position and tank will fill to capacity.
5. When the flow of water from the funnel stops, turn the thermostat knob to the “ON” position and wait approximately twenty minutes for the water in the tank to heat to the proper temperature. Some water will drip from the funnel during this time; this is due to expansion and should not occur thereafter.
6. Empty the dispenser and initiate another brew cycle as directed:
6A. Models S & SA:
Pour one pitcher of tap water into the screened area on top of the brewer.
6B. Models ST, STF, STA & STFA:
Place the "ON/OFF" switch in the "ON" upper position, and momentarily press and release the start switch.
7. Place the "ON/OFF" switch in the lower “OFF” position after water has stopped flowing from the funnel, and let the water in the tank reheat to the proper temperature.
8. Empty the dispenser and proceed as directed:
8A. Models S & SA:
The brewer is now ready for use in accordance with the coffee brewing instructions on the next page.
8B. Models ST, STF, STA & STFA:
Place the "ON/OFF" switch in the "ON" upper position, and momentarily press and release the start switch. Check the water volume in the dispenser after water has stopped flowing from the funnel. It should be 64 ounces.
9. If not, disconnect the brewer from the power source. On early models remove the access panel. Adjust the timer as required (see service section). Replace the panel, connect the brewer to the power source, and allow the water to reheat, start, and measure another brew cycle.
10. Repeat step 9 until 64 oz water volume is achieved.
11. The brewer is now ready for use in accordance with the coffee brewing instructions on the next page.
Page 5
29251 052500
OPERATING CONTROLS
Models S & SA:
These models function without operating controls.
Models ST, STF, STA & STFA: ON/OFF SWITCH
Placing the "ON/OFF" switch in the "OFF" lower position stops brewing. Stopping a brew cycle after it has been started will not stop the flow of water into the funnel until the tank syphons down to its proper level. Placing the switch in the "ON" upper position supplies power to the brew station warmer and enables the brew circuit and on Models STF and STFA refills the tank.
START SWITCH
Momentarily pressing and releasing the switch starts a brew cycle when the "ON/OFF" switch is in the "ON" upper position.
NOTE – The "ON/OFF" switch must be in the "ON" upper position to initiate and complete a brew cycle.
COFFEE BREWING
1. Insert a BUNN® filter into the funnel.
2. Pour the fresh coffee into the filter and level the bed of grounds by gently shaking.
3. Slide the funnel into the funnel rails.
4. Place an empty dispenser beneath the funnel.
5. Operate the brewer as directed:
5A. Models S & SA:
Pour one pitcher of tap water into the screened area on top of the brewer.
5B. Models ST, STF, STA & STFA:
Place the "ON/OFF" switch in the "ON" upper position. Momentarily press and release the start switch.
6. When brewing is completed, simply discard the grounds and filter.
CLEANING
1. The use of a damp cloth rinsed in any mild, non-abrasive, liquid detergent is recommended for cleaning all
surfaces on Bunn-O-Matic equipment.
2. Check and clean the sprayhead. The sprayhead holes must always remain open.
3. With the sprayhead removed, insert the deliming spring (provided) all the way into the sprayhead tube. When
inserted properly, no more than two inches of spring should be visible. Saw back and forth five or six times.
NOTE – In hard water areas, this may need to be done daily. It will help prevent liming problems in the brewer and takes less than a minute.
Page 6
29251 101598
TROUBLESHOOTING
A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department.
Inspection, testing, and repair of electrical equipment should be performed only by qualified service personnel.
All electronic components have 120 volt ac and low voltage dc potential on their terminals. Shorting of
terminals or the application of external voltages may result in board failure.
Intermittent operation of electronic circuit boards is unlikely. Board failure will normally be permanent. If an
intermittent condition is encountered, the cause will likely be a switch contact or a loose connection at a
terminal or crimp.
Solenoid removal requires interrupting the water supply to the valve. Damage may result if solenoids are
energized for more than ten minutes without a supply of water.
The use of two wrenches is recommended whenever plumbing fittings are tightened or loosened. This will help
to avoid twists and kinks in the tubing.
Make certain that all plumbing connections are sealed and electrical connections tight and isolated.
This brewer is heated at all times. Keep away from combustibles.
WARNING – • Exercise extreme caution when servicing electrical equipment.
• Unplug the brewer when servicing, except when electrical tests are specified.
• Follow recommended service procedures
• Replace all protective shields or safety notices
PROBLEM
Brew cycle will not start (ST, STF, STA & STFA)
PROBABLE CAUSE
1. No water
2. No power or incorrect voltage to the brewer
REMEDY
Water lines and valves to the brewer must be open.
(A1) Check the terminal block for 120 volts across the black and white terminals on two wire 120 volt brewers. (A2) Check the terminal block for 120 volts across the red and white terminals and the black and white terminal on three wire 120/240 volt brewers. (A3) Check the terminal block for 200 volts on Model STFB brewers or 240 volts on "A Series" brewers across the red and black termi­nals. (A4) Check the terminal block for 100 volts on Model SDB brewers across the white and black termi­nals.
Page 7
(B) Check circuit breakers or fuses.
29251 101598
TROUBLESHOOTING (cont.)
PROBLEM
Brew cycle will not start (cont.) (ST, STF, STA & STFA)
PROBABLE CAUSE
3. ON/OFF switch
4. Start switch
5. Timer
6. Solenoid valve
7. Strainer/flow control (.222 GPM)
REMEDY
Refer to
Service
- ON/OFF Switch
for testing. See page 17
Refer to
Service
- Start Switch for
testing procedures. See page 19
Refer to
Service
- Timer for testing
procedures. See page 22 or 24
Refer to
Service
- Solenoid Valve for testing procedures. See page 18
(A) Direction of flow arrow must be pointing towards brewer.
(B) Remove the strainer/flow con­trol and check for obstructions. Clear or replace.
Water is not hot
Inconsistent beverage level in dis­penser
1. Limit thermostat CAUTION - Do not eliminate or bypass limit thermostat. Use only BOM replacement part #29329.
1000.
2. Control thermostat
3. Tank heater
1. Strainer /flow control (.222 GPM) (ST, STF, STA & STFA)
Refer to
Service
- Limit Thermo­stat for testing procedures. See page 16
Refer to
Service
- Control Ther­mostat for testing procedures. See page 14
Refer to
Service
- Tank Heater for
testing procedures. See page 20
(A) Direction of flow arrow must be pointing towards the brewer.
(B) Remove the strainer/flow con­trol and check for obstruction. Clear or replace.
2. Liquid level board or level probe
Page 8
Refer to
Service
- Liquid Level Board for testing procedures. See page 26
29251 052500
TROUBLESHOOTING (cont.)
PROBLEM
Inconsistent beverage level in dis­penser (cont.)
Consistently low beverage level in the dispenser (ST, STF, STA & STFA)
PROBABLE CAUSE
3. Syphon system
4. Lime build-up CAUTION - Tank and tank compo­nents should be delimed regularly depending on local water condi­tions. Excessive mineral build-up on stainless steel surfaces can ini­tiate corrosive reactions resulting in serious leaks.
5. Water pressure (ST, STF, STA & STFA)
1. Timer
REMEDY
The brewer must be level or slightly lower in front to syphon properly.
Inspect the tank assembly for ex­cessive lime deposits. Delime as required.
The water pressure to the brewer must be at least 20 psi (138 kPa).
(A) Early models-Timer dial must indicate at least two minutes and fifteen seconds.
Spitting or excessive steaming
2. Strainer/flow control (.222 GPM)
1. Lime build-up CAUTION - Tank and tank compo­nents should be delimed regularly depending on local water condi­tions. Excessive mineral build-up on stainless steel surfaces can ini­tiate corrosive reactions resulting in serious leaks.
2. Control thermostat
(B) Refer to
Service
- Digital Timer for testing procedures. See page 24
(A) Direction of flow arrow must be pointing towards brewer.
(B) Remove the strainer/flow con­trol and check for obstructions. Clear or replace.
Inspect tank assembly for exces­sive lime deposits. Delime as re­quired.
Refer to
Service
- Control Ther­mostat for testing procedures. See page 14
Page 9
29251 052500
TROUBLESHOOTING (cont.)
PROBLEM
Dripping from sprayhead
Water flows into tank continuously (ON/OFF Switch "ON")
PROBABLE CAUSE
1. Syphon system
2. Lime build-up CAUTION - Tank and tank compo­nents should be delimed regularly depending on local water condi­tions. Excessive mineral build-up on stainless steel surfaces can ini­tiate corrosive reactions resulting in serious leaks.
3. Solenoid valve (ST, STF, STA & STFA)
1. Timer (ST, STF, STA & STFA)
REMEDY
The brewer must be level or slightly lower in front to syphon properly.
Inspect the tank assembly for ex­cessive lime deposits. Delime as required.
Remove the solenoid valve and clear any obstructions. Rebuild or replace the valve if necessary. See page 18
Refer to
Service -
Timer for testing
procedures. See page 22 or 24
Water flows into tank continuously (ON/OFF Switch "OFF")
Beverage overflows dispenser
2. Start switch
3. Liquid level board
4. Relay
1. Solenoid valve (ST, STF, STA & STFA)
1. Dispenser
2. Timer (ST, STF, STA & STFA)
Refer to
Service
- Start Switch for
testing procedures. See page 19
Refer to
Service
- LiquidLevel Board for testing procedures. See page 26
Refer to
Service
- Relay for testing
procedures. See page 28
Remove the Solenoid Valve and clean any obstruction. Rebuild or replace the valve if necessary. See page 18
The dispenser must be completely empty before starting a brew cycle.
Refer to
Service -
Timer for testing
procedures. See page 22 or 24
Page 10
29251 052500
TROUBLESHOOTING (cont.)
PROBLEM
Beverage overflows dispenser (cont.)
Weak beverage
PROBABLE CAUSE
3. Solenoid valve (ST, STF, STA & STFA)
1. Filter type
2. Coffee grind
3. Sprayhead
4. Funnel loading
REMEDY
Remove the Solenoid Valve and clean any obstruction. Rebuild or replace the valve if necessary. See page 18
The BUNN® paper filter must be used for proper extraction.
A fine or drip grind must be used for proper extraction.
A six-hole stainless steel spray­head must be used for proper extraction.
The BUNN® paper filter must be centered in the funnel and the bed of ground leveled by gentle shak­ing.
Dry coffee grounds remain in the funnel
Brewer is making unusal noises (ST, STF, STA & STFA)
5. Water temperature
1. Funnel loading
1. Solenoid valve
2. Plumbing lines
Place an empty funnel on an empty dispenser beneath the sprayhead. Initiate a brew cycle and check the water temperature immediately below the sprayhead with a ther­mometer. The reading should not
be less than 195°F. Adjust the
control thermostat to increase the water temperature. Replace if nec­essary.
The BUNN® paper filter must be centered in the funnel and the bed of grounds leveled by gently shak­ing.
The nut on the solenoid must be tight or it will vibrate during op­eration.
Plumbing lines should not resting on the counter top.
Page 11
29251 052500
TROUBLESHOOTING (cont.)
PROBLEM
Brewer is making unusal noises (ST, STF, STA & STFA)(cont.)
Automatic refill will not operate
PROBABLE CAUSE
3. Water supply
4. Tank heater
1. No water
2. Strainer/flow control
REMEDY
(A) The brewer must be connected to a cold water line.
(B) Water pressure to the brewer must not exceed 90 psi (620 kPa). Install a regulator if necessary to lower the working pressure to ap­proximately 50 psi (345 kPa).
Remove and clean lime off the tank heater. See page 20
Check plumbing
A. Direction of arrow must be pointing towards brewer.
B. Remove the strainer/flow con­trol and check for obstructions. Clean or replace.
Beverage not staying hot in dis­penser
3. Solenoid valve
4. Liquid level control board or level probe
5. Relay
1. ON/OFF switch
2. Warmer elements
Refer to
Service
- Solenoid Valve for testing procedures. See page 18
Refer to
Service
- Liquid level con­trol board or level probe for test­ing procedures. See page 26
Refer to
Service
- Relay for test-
ing procedures. See page 28
Refer to
Service
- ON/OFF switch for testing procedures. See page 17
Refer to
Service
- Warmer ele­ments for testing procedures. See page 29
Page 12
29251 052500
SERVICE
This section provides procedures for testing and replacing various major components used in this brewer should service become necessary. Refer to
Troubleshooting
cause of any problem.
WARNING - Inspection, testing, and repair of electrical equipment should be performed only by qualified service personnel. The brewer should be unplugged when servicing, except when electrical tests are re­quired and the test procedure specifically states to plug-in the brewer.
COMPONENT ACCESS
WARNING - Disconnect the brewer from the power
source before the removal of any panel or the replace­ment of any component.
All components are accessible by the removal of the top cover or top warmer housing and front and rear inspection panels.
for assistance in determining the
The top cover for Models with no top warmer and the top warmer housing is attached with four #8-32 screws. Unplug upper wiring harness and set housing aside.
The front and rear inspection panels are attached with four #8-32 screws each.
Contents
Control Thermostat............................................. 14
Limit Thermostat ................................................ 16
ON/OFF Switch.................................................... 17
Solenoid ............................................................. 18
Start Switch (Brew) ............................................ 19
Tank Heater ........................................................ 20
Brew Timer (Early Models) ................................. 22
Digital Timer (Late Models) ................................ 24
Liquid Level Board ............................................. 26
Relay.................................................................. 28
Warmer Element ................................................ 29
Thermal Cut-off ................................................. 30
Wiring Diagrams.................................... 31 thru 43
P1584
FIG. 1 COMPONENT ACCESS
Page 13
29251 052500
SERVICE (cont.)
CONTROL THERMOSTAT
O
F
F
B
U N
N
I
H
Test Procedures:
1. Disconnect the brewer from the power source.
2. Locate the blue wire on the control thermostat.
3. Check the voltage across the blue wire on the control thermostat and the white insert on two pole 100 or 120 volt terminal block or three pole 120/240 volt terminal blocks and the red insert on two wire 200 volt or 240 volt terminal block with a voltmeter. Connect the brewer to the power source. The indication must be: a) 120 volts ac for two wire 120 volt models and three wire 120/240 volt models. b) 200 to 240 volts ac for two wire 200 or 240 volt models. c) 100 volts ac for two wire 100 volt models.
4. Disconnect the brewer from the power source.
If voltage is present as described, proceed to #5. If voltage is not present as described, refer to the
Diagrams
and check the brewer wiring harness.
Wiring
FIG. 2 CONTROL THERMOSTAT
Location:
Models S & SA: The control thermostat is mounted on a bracket inside the rear inspection cover on the left side. Models ST, STA, STF & STFA: The control ther­mostat is located inside the front inspection cover on the component mounting bracket.
P1585
Page 14
5. Locate the black wire on the control thermostat.
6. Gently remove the capillary bulb and grommet from the tank.
7. Check the voltage across the black wire of the control thermostat and the white insert on the two pole 100 or 120 volt or three pole 120/240 volt terminal block and the red insert on the two pole 200 volt or 240 volt terminal block with a voltmeter when the control thermostat is turned "ON" (Fully clockwise). Connect the brewer to the power source. The indication must be: a) 120 volts ac for two wire 120 volt models and three wire 120/240 volt models. b) 200 to 240 volts ac for two wire 200 volt or 240 volt models. c) 100 volts ac for two wire 100 volt models.
8. Disconnect the brewer from the power source.
If voltage is present as described, reinstall the capillary tube into the tank to the line 4.5" above the bulb, the control thermostat is operating properly. If voltage is not present as described, replace the thermostat.
29251 052500
SERVICE (cont.)
CONTROL THERMOSTAT (cont.)
Removal and Replacement:
1. Remove wires from control thermostat leads.
2. Remove the thermostat capillary bulb by firmly pulling-up on the capillary at the tank lid. This will disengage the grommet from the tank lid.
3. Models S & SA: Remove the two #8-32 screws securing control thermostat bracket mounted inside the rear inspection panel. Models ST, STA, STF & STFA: Remove the one #8-32 screw securing the control thermostat to the component bracket in the front inspection panel.
4. Slide the grommet to the line 4.5" above the bulb on the new capillary tube.
5. Insert the capillary bulb through the hole in the tank lid and press the grommet firmly and evenly so that the groove in the grommet fits into the tank lid.
6. Carefully bend the capillary tube so that the tube and bulb inside the tank are in the vertical posi­tion.
NOTE - The capillary tube must be clear of any electri-
cal termination and not kinked.
7. Models S & SA: Using two #8-32 screws secure the control thermostat inside the rear inspection panel. Models ST, STA, STF & STFA: Using one #8-32 screw secure the control thermostat to the com­ponent bracket inside the front inspection panel.
8. Refer to FIG. 3 when reconnecting the wires.
9. Adjust the control thermostat as required.
BLU to Limit Thermostat
BLK to Tank Heater
O
F
F
BUNN
HI
P2182
FIG. 3 CONTROL THERMOSTAT TERMINALS
Page 15
29251 052500
SERVICE (cont.) LIMIT THERMOSTAT
Removal and Replacement:
1. Remove all wires from limit thermostat termi­nals.
2. Carefully slide the limit thermostat out from under the retaining clip and remove limit thermo­stat.
3. Carefully slide the new limit thermostat into the retaining clip.
4. Refer to FIG. 5 when reconnecting the wires.
P1586
FIG. 4 LIMIT THERMOSTAT
Location:
The limit thermostat is located on the rear of
tank assembly.
Test Procedures:
1. Disconnect the brewer from the power source.
2. Disconnect the blue and black wires from the limit thermostat.
3. Check for continuity across the limit thermostat terminals with a ohmmeter.
If continuity is present as described, the limit thermo­stat is operating properly. If continuity is not present as described, replace the limit thermostat.
BLK to Tank Heater Switch
BLK to BLU Lead from Control Thermostat
FIG. 5 LIMIT THERMOSTAT TERMINALS
P1800
Page 16
29251 052500
SERVICE (cont.)
ON/OFF SWITCH (Models ST, STA, STF & STFA)
P1589
5. With the black wire removed, remove from the lower terminal the white/red wire for the lower warmer switch, the brown/black wire for the top front warmer switch or the blue/black wire for the top rear switch.
6. Check for continuity across the center and lower terminal with the switch in the "ON" position. Continuity must not be present when the switch is in the "OFF" position.
If continuity is present as described, reconnect the black wire to the center terminal and the white/red to the lower terminal. If continuity is not present as described, replace the switch.
FIG. 6 ON/OFF SWITCH
Location:
The ON/OFF switch is located second from right
on the switch panel.
Test Procedure:
1. Disconnect the brewer from the power source.
2. Viewing the switch from the back remove the white or red wire from the upper terminal and the black wire from the center terminal.
3. Check the voltage across the white or red wire and the black wire with a voltmeter. Connect the brewer to the power source. The indication must be: a) 120 volts ac for two wire 120 volt models and three wire 120/240 volt models. b) 200 to 240 volts ac for two wire 200 or 240 volt models. c) 100 volts ac for two wire 100 volt models.
4. Disconnect the brewer from the power source.
Removal and Replacement:
1. Remove the wires from the switch terminals.
2. Compress the clips inside the switch panel and gently push the switch through the opening.
3. Push the new switch into the opening and spread the clips to hold switch in the switch panel .
4. Refer to FIG. 7 when reconnecting the wires.
BLK to Terminal
Block (Black
Insert)
WHI/VIO to
Lower Warmer
BRN/BLK to Top
Front Warmer
BLU/BLK to Top
Rear Warmer
WHI to Terminal Block
(White Insert on 120/
208V or 120/240V
Models)
RED to Terminal Blck
(Red Insert on 200V
or 240V Models)
P1590
FIG. 7 ON/OFF SWITCH TERMINALS
If voltage is present as described, reconnect the white or red wire and proceed to #5. If voltage is not present as described, refer to the
Wiring Diagrams
and check the brewer wiring har-
ness.
Page 17
29251 052500
SERVICE (cont.)
SOLENOID VALVE (Models ST, STA, STF & STFA)
P1587
FIG. 8 SOLENOID
Location:
The solenoid valve is located inside the front inspection panel on the center lower part of the com­ponent mounting bracket.
Test Procedures:
1. Disconnect the brewer from the power source.
2. Disconnect the wires (FIG. 9) from the solenoid
valve. With the "ON/OFF" switch in the "ON" upper position press the start switch.
3. Check the voltage across the two wires with a
voltmeter. Connect the brewer to the power source. The indication must be: a) 120 volts ac for two wire 120 volt models and three wire 120/240 volt models. b) 200 to 240 volts ac for two wire 200 or 240 volt models. c) 100 volts ac for two wire 100 volt models.
4. Disconnect the brewer from the power source.
6. Check the solenoid valve for coil action. Connect the brewer to the power source. With "ON/OFF" switch in the "ON" upper position press start switch and listen carefully in the vicinity of the solenoid valve for a" clicking" sound as the coil magnet attracts.
7. Disconnect the brewer from the power source.
If the sound is heard as described and water will not pass through the solenoid valve, there may be a blockage in the water line before the solenoid valve or, the solenoid valve may require inspection for wear, and removal of waterborne particles. If the sound is not heard as described, replace the solenoid valve.
Removal and Replacement:
1. Remove the wires from the solenoid valve.
2. Turn-off the water supply to the brewer.
3. Disconnect the water lines to and from the sole­noid valve.
4. Remove the two #8-32 screws securing the so­lenoid mounting bracket to the component bracket. Remove solenoid bracket and solenoid valve as an assembly.
5. Remove the two #10-32 screws and lockwashers securing the solenoid valve to the solenoid bracket.
6. Using two #10-32 screws and lockwashers in­stall new solenoid valve on solenoid mounting bracket.
7. Using two #8-32 screws install solenoid valve and bracket to the component bracket.
8. Securely fasten the water lines to and from the solenoid valve.
9. Refer to FIG. 9 when reconnecting the wires.
If voltage is present as described, proceed to #5. If voltage is not present as described, refer to
Diagrams
and check brewer wiring harness.
Wiring
5. Check for continuity across the solenoid valve coil terminals.
If continuity is present as described, reconnect the wires (FIG. 9) to the solenoid. If continuity is not present as described, replace the solenoid valve.
Page 18
P1588
FIG. 9 SOLENOID TERMINALS
29251 052500
SERVICE (cont.)
START SWITCH (Models ST, STA, STF & STFA)
P1589
FIG. 10 START SWITCH
Removal and Replacement:
1. Remove the WHI/YEL and WHI/ORA wires from the start switch.
2. Compress the clips inside the hood and gently push the switch through the opening.
3. Push new switch into the opening and spread the clips to hold the start switch in the hood.
4. Refer to FIG. 11 when reconnecting the wires.
WHI/YEL to Brew Timer TL3 WHI/ORAto Brew Timer TL5
Location:
The START switch is located far right on the switch
panel.
Test Procedures:
1. Disconnect the brewer from the power supply.
2. Disconnect the WHI/YEL wire from the top switch terminal and the WHI/ORA wire from the bottom switch terminal.
3. Check for continuity across the two terminals on the switch when it is held in the lower position. Continuity must not be present across these terminals in the upper position.
If continuity is present as described, reconnect the WHI/YEL wire to the top terminal and the WHI/ORA wire to the bottom terminal. If continuity is not present as described, replace the switch.
P1591
FIG. 11 START SWITCH TERMINALS
Page 19
29251 052500
SERVICE (cont.) TANK HEATER
P1592
FIG. 12 TANK HEATER
Location:
The tank heater is located inside the tank and
secured to the tank bottom.
Test Procedures:
1. Disconnect the brewer from the power supply.
2. Check the voltage across the black and white wires on 100 or 120 volt models or the black and red wires for 120/240 volt models, 200 volt models and 240 volt models with a voltmeter. Connect the brew to the power source. The indication must be: a) 120 volts ac for two wire 120 volt 15 and 20 amp models . b) 240 volts ac for three wire 120/240 volt models.
c) 200 to 240 volts ac for two wire 200 or 240 volt models. d) 100 volts ac for two wire 100 volt models.
3. Disconnect the brewer from the power source.
If voltage is present as described, proceed to #4 If voltage is not present as described, refer to the
Wiring Diagrams
and check wiring harness.
4. Disconnect the black wire and the white wire or red wire from the tank heater terminals.
5. Check for continuity across the tank heater termi­nals.
If continuity is present as described, reconnect the wires, the tank heater is operating properly. If continuity is not present as described, replace the tank heater.
NOTE- If the tank heater remains unable to heat, remove and inspect heater for cracks in the sheath.
Removal and Replacement:
1. Remove top cover or top warmer housing as prevoiusly described.
2. Disconnect the water supply tube from the sole­noid.
3. On brewers with faucet, disconnect the faucet.
4. Remove sprayhead and the hex nut securing the sprayhead tube to the hood. Set aside for reas­sembly.
5. Disconnect the wire from the tank level probe.
6. Remove the thermostat capillary bulb as de­scribed in section for control thermostat.
7. Disconnect the wires from the limit thermostat.
Page 20
29251 052500
SERVICE (cont.) TANK HEATER (Cont.)
8. Disconnect the black wire and the white or red wire from the tank heater terminals.
9. Remove the three #8-32 nuts and holddown brackets securing the tank lid to the tank.
10. Remove the tank lid with level probe.
11. Remove the switch panel and disconnect the leads to the tank "Keep Warm" heater.
12. On 100 volt models equipped with rear drain, open the shut-off valve and drain water from the tank. Disconnect drain tube and fittings from tank.
13. Direct the pink probe wire, capillary tube and top warmer wiring harness through the nylon bush­ing located on the rear of the basin flange.
14. Lift tank and fill basin assembly from housing and drain water from tank.
15. Remove the two hex nuts securing the tank heater to the bottom of tank. Remove tank heater with gaskets and discard.
16. Install new tank heater with gaskets to the tank and secure with two hex nuts.
17. Install tank with limit thermostat, sprayhead tube and tank heater.
18. Reconnect the inlet and outlet water lines to the solenoid and faucet.
19. Secure spayhead tube to hood using a hex nut.
20. Install sprayhead.
21. Reconnect the wires to the limit thermostat and control thermostat. See limit thermostat and control thermostat sections in this manual when reconnecting wires.
22. Install tank lid with holddown brackets and #8-32 nuts
23. Install the thermostat capillary bulb as described in section for control thermostat.
24. Reconnect the wire to the liquid level probe.
25. Refer to FIG. 13 when reconnecting the tank heater wires.
WHI or RED Wire From Tank Heater
BLK Wire to Limit
Thermostat
P1593
FIG. 13 TANK HEATER TERMINALS
Page 21
29251 052500
SERVICE (cont.) BREW TIMER (Early Models ST, STA, STF & STFA)
OLD STYLE
P1594
FIG. 14 BREW TIMER
Location:
The timer dial is located inside the front inspection panel on the top of component mounting bracket. The timer board is located inside the rear inspection panel on the component mounting bracket.
Test Procedures:
1. Disconnect the brewer from the power source.
2. Rotate the dial fully counterclockwise.
3. With a voltmeter, check the voltage across termi-
nals TL1 and TL2 when the "ON/OFF" switch is in
the "ON" position. Connect the brewer to the power
source. The indication must be:
a.) 120 volts ac for two wire 120 volt models,
three wire 120/208 volt models and three wire
120/240 volt models.
b.) 200 to 240 volts ac for two wire 200 or 240 volt
models.
4. Disconnect the brewer from the power source.
If voltage is present as described, proceed to #5. If voltage is not present as described, refer to the
Wiring Diagrams
and check the brewer wiring har-
ness.
5. Disconnect the white/orange wire from terminal TL3 and the white/yellow wire from terminal TL5. Check for continuity across the two wires when the start switch is pressed to the "START" position.
If continuity is present as described, reconnect the wires and proceed to #6. If continuity is not present as described, refer to the
Wiring Diagrams
and check the brewer wiring har-
ness.
6. With a voltmeter, check the voltage across termi­nals TL1 and TL4 when the "ON/OFF" switch is in the "ON" position. Connect the brewer to the power source. The indication must be zero.
If voltage indications are other than described, discon­nect the brewer from the power source and replace the timer. If voltage is correct, proceed to #7.
7. With a voltmeter, check the voltage across termi­nals TL1 and TL4 when the "ON/OFF" switch is in the "ON" position. Connect the brewer to the power source and press the start switch. The indication must be: a.) 120 volts ac for two wire 120 volt models, three wire 120/208 volt models and three wire 120/240 volt models. b.) 200 to 240 volts ac for two wire 200 or 240 volt models.
If voltage indications are other than described, discon­nect the brewer from the power source and replace the timer. If voltage is correct, readjust the timer as required.
Page 22
29251 082100
SERVICE (cont.)
BREW TIMER (Early Models)(cont.)
Removal and Replacement:
1. Remove all wires from the timer.
2. Remove the circuit board and dial plate from the brackets.
3 Install new timer circuit board as described in
Late Model Timer
section on the following pages.
4. Refer to Fig. 17 when reconnecting the wires.
5. Install the Timer Setting decal provided with the replacement timer kit, on the back side of the front access panel.
6. Adjust the timer as required. Refer to
Timer
section on the following pages.
Late Model
S
.
E
T
IC
T
U
C
A
IN
A
-M
M
V
0
-O
2
N
N
1
-
U
0
B
2
6
2
/N
P
WHI/RED TL1 to ON/OFF Switch
WHI TL2 to Terminal Block and Warmer Element (120V Two Pole, 120/208V or 120/240V Three Pole Terminal Block) RED TL2 to Terminal Block and Warmer Element (200V or 240V Two Pole Termi­nal Block)
WHI/ORA TL3 to Start Switch (top)
WHI/GRN TL4 to Solenoid Valve
or Relay Terminal B
WHI/YEL TL5 to Start Switch (bottom)
OLD STYLE
FIG. 15 BREW TIMER TERMINALS
P1595
Page 23
29251 082100
SERVICE (cont.) DIGITAL BREW TIMER (Late Models)
K C
K
O L
C O
T E
L
S
T E S
2
J
J1
TL1
TL2
TL3
TL4
TL5
P2181
FIG. 16 DIGITAL BREW TIMER
Location:
The timer is located inside the front inspection panel. Some earlier models, with the new timer will have them located inside the rear panel.
Test Procedures: NOTE: Do not remove or install wires while timer board is installed. Pressure applied to one side may cause damage to the board.
1. Disconnect the brewer from the power source and
remove the front panel.
2. With a voltmeter, check the voltage across termi-
nals TL1 and TL2 when the "ON/OFF" switch is in
the "ON" position. Connect the brewer to the power
source. The indication must be:
a.) 120 volts ac for two wire 120 volt models,
three wire 120/208 volt models and three wire
120/240 volt models.
b.) 200 to 240 volts ac for two wire 200 or 240 volt
models.
3. Disconnect the brewer from the power source.
If voltage is present as described, proceed to #4. If voltage is not present as described, refer to the
Wiring Diagrams
and check the brewer wiring har-
ness.
Page 24
4. With a voltmeter, check the voltage across termi­nals TL1 and TL4 when the "ON/OFF" switch is in the "ON" position. Connect the brewer to the power source. The indication must be zero volts.
If voltage is as described, proceed to #5. If voltage is not as described, disconnect the brewer from the power source and replace the timer.
5. With a voltmeter, check the voltage across termi­nals TL1 and TL4 when the "ON/OFF" switch is in the "ON" position. Connect the brewer to the power source and press the start switch. The indication must be: a.) 120 volts ac for two wire 120 volt models, three wire 120/208 volt models and three wire 120/240 volt models. b.) 200 to 240 volts ac for two wire 200 or 240 volt models.
If voltage is as described, the brew timer is operating properly. Reset the timer as required, to obtain the desired brew volume. If voltage is not as described, test the START switch for operation before replacing the timer (see page 19). Test ON/OFF Switch if START Switch is functional (see page 17). If voltage is as described for both switches, disconnect the brewer from the power source and replace the timer.
Removal and Replacement: NOTE: Do not remove or install wires while timer board is installed. Pressure applied to one side may cause damage to the board.
1. Remove the two #6-32 screws securing circuit board to component mounting bracket.
2. Remove circuit board and nylon spacers.
3. Remove all wires from the timer.
4. Attach all wires to the replacement timer board prior to installation to the component mounting bracket. Refer to FIG. 17 when reconnecting the wires.
5. Install new circuit board with nylon spacers to component mounting bracket.
6. Adjust the timer as described below.
29251 011501
SERVICE (cont.)
DIGITAL BREW TIMER (Late Models)(cont.)
Timer Setting: NOTE: Check that the brewer is connected to water supply, the tank is properly filled, and a funnel and server are in place, prior to setting or modifying volumes. NOTE: All volume settings must be done with the sprayhead installed.
1. Modifying brew volumes. To modify a brew vol­ume, first check that the SET/LOCK switch is in the "SET" position on the circuit board.
To increase a brew volume, place the ON/OFF
switch in the "ON" position, press and hold the START switch until three clicks are heard. Release the switch (Failure to release the switch within two seconds after the third click causes the volume setting to be aborted and previous volume setting will remain in memory) and press it again one or more times. Each time the switch is pressed, two seconds are added to the brew time period. Allow the brew cycle to finish in order to verify that the desired volume has been achieved.
To decrease a brew volume, place the ON/OFF
switch in the "ON" position, press and release the START switch once for every two-second interval to be removed from the total brew time period; then imme­diately press and hold down the START switch until three clicks are heard. Release the switch. (Failure to release the switch within two seconds after the third click causes the volume setting to be aborted and previous volume setting will remain in memory). Allow the brew cycle to finish in order to verify that the desired volume has been achieved.
2. Setting brew volumes. To set a brew volume, first check that the SET/LOCK switch is in the "SET" position on the circuit board. Place the ON/OFF switch in the "ON" position, press and hold the START switch until three distinct clicks are heard and then release the switch. (Failure to release the switch within two sec­onds after the third click causes the volume setting to be aborted and previous volume setting will remain in memory). View the level of the liquid being dispensed. When the desired level is reached, turn the ON/OFF switch to "OFF".
NOTE: Several ounces of water will continue to syphon from the tank after turning the switch "OFF". The brewer remembers this volume and will continue to brew batches of this size until the volume setting procedure is repeated. NOTE: When brewing coffee, volumes will decrease due to absorption by the coffee grounds.
3. Setting programming disable feature. If it be­comes necessary to prevent anyone from changing brew time once programmed, you can set the SET/ LOCK switch to the "LOCK" position. This will prevent any further programming.
NOTE: To relocate a rear-mounted digital brew timer to the front of the brewer, order kit number 32005.0000 for 120/240V 3-wire models. Order 32005.0001 for 200V-240V 2-wire models. These kits have the parts necessary to relocate the timer.
TL1 - WHI/RED to ON/OFF Switch TL2 - WHI to Terminal Block and Warmer
element (120V two-pole, 120/208V or 120/240V three pole terminal block) or RED to Terminal Block and Warmer element (200V or 240V two pole ter-
minal block) TL3 - WHI/ORN to Start Switch (Top) TL4 - WHI/GRN to Solenoid Valve or Relay
Terminal B TL5 - WHI/YEL to Start Switch (Bottom)
Page 25
FIG. 17 DIGITAL TIMER WIRING
P2037
29251 011501
SERVICE (cont.)
LIQUID LEVEL CONTROL BOARD (Models STF & STFA)
P1598
FIG. 18 LIQUID LEVEL PROBE
& CONTROL BOARD
Location:
The liquid level probe is located within the tank lid inside the fill basin. The liquid level board is located inside the rear inspection panel on the top left of component mounting bracket.
4. Disconnect the brewer from the power source.
If voltage is present as described, proceed to #5. If voltage is not present as described, refer to the wiring diagrams and check the brewer wiring harness.
5. Reconnect the blue wire to terminal 1.
6. Carefully connect a piece of insulated jumper wire to terminal 4. Keep the other end of this wire away from any metal surface of the brewer.
7. Check the voltage across terminals 1 & 3 with a voltmeter. Connect the brewer to the power source.Turn the "ON/OFF" switch to the "ON" position The indication must be: a.) 120 volts ac for three wire 120/208 volt models and three wire 120/240 volt models after a delay of approximately 5 seconds. b.) 200 to 240 volts ac for two wire 200 or 240 volt models after a delay of approximately 5 seconds.
8. Touch the free end of jumper wire to the brewer housing. The indication must be 0.
9. Move the jumper wire away from the brewer housing. The indication must again be: a.) 120 volts ac for three wire 120/208 volt models and three wire 120/240 volt models after a delay of approximately 5 seconds. b.) 200 to 240 volts ac for two wire 200 or 240volt models after a delay of approximately 5 seonds.
10. Disconnect the brewer from the power source and remove the jumper wire from terminal 4.
Test Procedure.
1. Disconnect the brewer from the power source.
2. Remove the blue wire from terminal 1 and the pink wire from terminal 4 of the circuit board.
3. Check the voltage across terminals 2 and 3 with a voltmeter. Connect the brewer to the power source. Turn the "ON/OFF" switch to the "ON" position.The indication must be: a) 120 volts ac for two wire 120 volt models and three wire 120/240 volt models. b) 200 to 240 volts ac for two wire 200 volt or 240 volt models. c) 100 volts ac for two wire 100 volt models.
Page 26
29251 052500
SERVICE (cont.) LIQUID LEVEL CONTROL BOARD (Models STF & STFA)(Cont,)
If voltage is present as described, the level control board is operating properly, proceed to #11. If voltage is not present as described, replace the level control board.
11. Reconnect the pink wire to terminal 4.
12. Gently pull the probe out of the tank lid and inspect for corrosion. Replace it if necessary.
13. Place the probe so that neither end is in contact with any metal surface of the brewer.
14. Check the voltage across terminals 1 & 3 with a voltmeter. Connect the brewer to the power source. Turn the "ON/OFF" switch to the "ON" position. The indication must be: a.) 120 volts ac for three wire 120/208 volt mod­els and three wire 120/240 volt models after a delay of approximately 5 seconds. b.) 200 to 240 volts ac for two wire 200 or 240 volt models after a delay of approximately 5 seconds.
15. Move the probe's flat end to the brewer housing. The indication must be 0.
16. Move the probe's flat end away from the brewer housing. The indication should again be: a.) 120 volts ac for three wire 120/208 volt models and three wire 120/240 volt models. b.) 200 to 240 volts ac for two wire 200 or 240 volt models.
17. Disconnect the brewer from the power source.
If voltage is present as described, reinstall the probe, the level control board and level probe are operating properly. If voltage is not present as described, check the pink probe wire.
Removal and Replacement:
1. Remove all wires from the level control board.
2. Remove two #8-32 screws and lockwashers holding level control board to component bracket.
3. Install the new level control board to the component bracket. Make certain that the lockwashers are between the level control board and the component bracket.
4. Refer to FIG. 19 when reconnecting the wires.
BLU to Relay 2 WHI/RED to Relay 5 and Timer TL1 WHI to Timer TL2 PNK to Probe
Page 27
P1599
FIG. 19 LIQUID LEVEL CONTROL
BOARD TERMINALS
29251 052500
SERVICE (cont.) TIMER RELAY (Models STF & STFA)
Location:
The relay is located inside the front inspection
panel on the bottom of component mounting bracket.
P1596
If continuity is present as described, reconnect the WHI/RED and WHI/BLU wires to the relay, relay is operating properly. If continuity is not present as described, replace the relay.
6. Remove the BLU wire from terminal 2 and the WHI/BLU wire from terminal 7 on the relay.
7. Check for continuity across terminals 2 and 7 by manually closing the relay contact. Continuity must be present when contact is released.
If continuity is present as described, reconnect the BLU and WHI/BLU wires to the relay, relay is operating properly. If continuity is not present as described, replace the relay.
Removal and Replacement:
1. Remove all wires from the relay terminals.
2. Remove the two #6-32 screws securing the relay
and shield to the mounting bracket.
3. With the two #6-32 screws, secure the new relay
and shield to the mounting bracket.
4. Refer to FIG.21 when reconnecting the relay
wires.
5. Fold the flap of the protective shield over the
relay and tuck the edge inside the housing.
FIG. 20 TIMER RELAY
Test Procedure.
1. Disconnect the brewer from the power source.
2. Remove the WHI/RED wire from the "A" terminal and the WHI/GRN wire from the "B" terminal on the relay.
3. Check for continuity across the "A" and "B" termi nals.
If continuity is present as described, reconnect the WHI/RED and WHI/GRN wires to the relay and pro­ceed to #4. If continuity is not present as described, replace the relay.
4. Remove the WHI/RED wire from terminal 5 and the WHI/BLU wire from terminal 7 on the relay.
5. Check for continuity across terminals 5 and 7 by manually closing the relay contact. Continuity must be present until contact is released.
BLU to L1 Liquid
2-
Level board
WHI/RED to L2 on
5-
Liquid Level Board
WHI/GRN toTL4
B-
on Brew Timer
WHI/BLU to
7-
Solenoid Valve
WHI/RED to TL1
A-
on Brew Timer
FIG. 21 TIMER RELAY TERMINALS
P1597
Page 28
29251 052500
SERVICE (cont.)
WARMER ELEMENTS
Location:
The warmer elements are located under the
warmer plates.
3. Check voltage across the WHI wire from the terminal block and the wire from the "ON/OFF" switch to the warmer element with a voltmeter with the "ON/OFF" switch in the "ON" position. The indication must be: a) 120 volts ac for two wire 120 volt versions. b) 120 volts ac for three wire 120/208 volt versions or 120/240 volt versions.
4. Disconnect the brewer from the power source.
If voltage is present as described, proceed to #5. If voltage is not present as described, refer to wiring diagrams and check brewer wiring harness.
5. Check the continuity across the two terminals on the warmer element.
If continuity is present as described, reconnect the wires on the warmer element. If continuity is not present as described, replace the warmer element.
P1601
FIG. 22 WARMER ELEMENTS
Test Procedures:
1. Disconnect the brewer from the power source.
2. Use the WHI wire to the terminal block and the wire from the warmer element to the "ON/OFF" switch.
BRN/BLK Wire to Top Front Warmer Switch BLU/BLK Wire to Top Rear Warmer Switch
WHI Wire to Terminal Block (White Insert on 120/208V or 120/240V Models) or RED Wire to Terminal Block (Red Insert on 200V or 240V Models)
Removal and Replacement:
1. Remove the three #4-40 screws securing the warmer assembly to the brewer.
2. Lift the warmer assembly from the brewer.
3. Disconnect the two wires from the warmer ele­ment terminals.
4. Remove the two #8-32 nuts securing the warmer element to the warmer plate.
5. Securely install new warmer element.
6. Reconnect the two wires to warmer element terminals.
7. Securely install warmer assembly on the brewer.
8. Refer to FIG. 23 when reconnecting the wires.
WHI/VIO Wire to Lower Warmer/ON Switch
WHI Wire to Terminal Block (White Insert on 120/208V or 120/240V Models) or RED Wire to Terminal Block (Red Insert on 200V or 240V Models)
FIG. 23 WARMER ELEMENT TERMINALS
Page 29
P1602
29251 052500
SERVICE (cont.)
THERMAL CUT-OFF (Models SA, STA & STFA)
Location:
The thermal cutoffs are located on both tank
heater terminals.
Test Procedures:
1. Disconnect the brewer from the power source.
2. Disconnect the thermal cutoff from the tank heater terminal and the limit thermostat or wir­ing harness.
3. Check for continuity across the thermal cutoff terminals using an ohmmeter.
Thermal cutoff to BLK Lead
If continuity is present, the thermal cutoff is operating properly. If continuity is not present as described, replace the thermal fuse.
Removal and Replacement:
1. Disconnect the thermal cutoff from the tank heater terminal and the limit thermostat or wir­ing harness.
2. Remove thermal cutoff and discard.
3. Connect new thermal cutoff to the tank heater terminal and the limit thermostat or wiring har­ness.
4. Refer to FIG. 24 when reconnecting wires.
Thermal cutoff to WHI or RED Lead
FIG. 24 THERMAL CUT-OFF
P1593
Page 30
29251 052500
Page 31
29251 052500
Page 32
29251 052500
Page 33
29251 052500
Page 34
29251 052500
Page 35
29251 052500
Page 36
29251 052500
Page 37
29251 052500
Page 38
29251 052500
Page 39
29251 052500
Page 40
29251 052500
Page 41
29251 052500
Page 42
29251 080400
Page 43
29251 052500
Loading...