Bunn Brewise 39132 User Manual

Page 1
SERVICE SUPPLEMENT
TO 39132.0000
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 FAX: (217) 529-6644
39132.0003A 04/12 ©2010 Bunn-O-Matic Corporation
Page 2
Page 2
BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTY
Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows:
1) Airpots, thermal carafes, decanters, GPR servers, iced tea/coffee dispensers, MCP/MCA pod brewers thermal servers and Thermofresh servers (mechanical and digital)- 1 year parts and 1 year labor.
2) All other equipment - 2 years parts and 1 year labor plus added warranties as specifi ed below: a) Electronic circuit and/or control boards - parts and labor for 3 years. b) Compressors on refrigeration equipment - 5 years parts and 1 year labor. c) Grinding burrs on coffee grinding equipment to grind coffee to meet original factory screen sieve analysis - parts
and labor for 4 years or 40,000 pounds of coffee, whichever comes fi rst.
These warranty periods run from the date of installation BUNN warrants that the equipment manufactured by it will be commercially free of defects in material and workmanship existing at the time of manufacture and appearing within the applicable warranty period. This warranty does not apply to any equipment, component or part that was not manufactured by BUNN or that, in BUNN’s judgment, has been affected by misuse, neglect, alteration, improper installation or operation, improper maintenance or repair, non periodic cleaning and descaling, equipment failures related to poor water quality, damage or casualty. In addition, the warranty does not apply to replacement of items subject to normal use including but not limited to user replaceable parts such as seals and gaskets. This warranty is conditioned on the Buyer 1) giving BUNN prompt notice of any claim to be made under this warranty by telephone at (217) 529-6601 or by writing to Post Offi ce Box 3227, Springfi eld, Illinois 62708-3227; 2) if requested by BUNN, shipping the defective equipment prepaid to an authorized BUNN service location; and 3) receiving prior authorization from BUNN that the defective equipment is under warranty.
THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTY, WRITTEN OR ORAL, EX­PRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF EITHER MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. The agents, dealers or employees of BUNN are not authorized to make
modifi cations to this warranty or to make additional warranties that are binding on BUNN. Accordingly, statements by such individuals, whether oral or written, do not constitute warranties and should not be relied upon. If BUNN determines in its sole discretion that the equipment does not conform to the warranty, BUNN, at its exclusive op­tion while the equipment is under warranty, shall either 1) provide at no charge replacement parts and/or labor (during the applicable parts and labor warranty periods specifi ed above) to repair the defective components, provided that this repair is done by a BUNN Authorized Service Representative; or 2) shall replace the equipment or refund the purchase price for the equipment.
THE BUYER’S REMEDY AGAINST BUNN FOR THE BREACH OF ANY OBLIGATION ARISING OUT OF THE SALE OF THIS EQUIPMENT, WHETHER DERIVED FROM WARRANTY OR OTHERWISE, SHALL BE LIMITED, AT BUNN’S SOLE OPTION AS SPECIFIED HEREIN, TO REPAIR, REPLACEMENT OR REFUND.
In no event shall BUNN be liable for any other damage or loss, including, but not limited to, lost profi ts, lost sales, loss of use of equipment, claims of Buyer’s customers, cost of capital, cost of down time, cost of substitute equipment, facilities or services, or any other special, incidental or consequential damages.
392, AutoPOD, AXIOM, BrewLOGIC, BrewMETER, Brew Better Not Bitter, BrewWISE, BrewWIZARD, BUNN Espress, BUNN Family Gourmet, BUNN Gourmet, BUNN Pour-O-Matic, BUNN, BUNN with the stylized red line, BUNNlink, Bunn-OMatic, Bunn-O-Matic, BUNNserve, BUNNSERVE with the stylized wrench design, Cool Froth, DBC, Dr. Brew stylized Dr. design, Dual, Easy Pour, EasyClear, EasyGard, FlavorGard, Gourmet Ice, Gourmet Juice, High Intensity, iMIX, Infusion Series, In­tellisteam, My Café, Phase Brew, PowerLogic, Quality Beverage Equipment Worldwide, Respect Earth, Respect Earth with the stylized leaf and coffee cherry design, Safety-Fresh, savemycoffee.com, Scale-Pro, Silver Series, Single, Smart Funnel, Smart Hopper, SmartWAVE, Soft Heat, SplashGard, The Mark of Quality in Beverage Equipment Worldwide, ThermoFresh, Titan, trifecta, Velocity Brew, A Partner You Can Count On, Air Brew, Air Infusion, Beverage Bar Creator, Beverage Profi t Calculator, Brew better, not bitter., BUNNSource, Coffee At Its Best, Cyclonic Heating System, Daypart, Digital Brewer Control, Nothing Brews Like a BUNN, Pouring Profi ts, Signature Series, Tea At Its Best, The Horizontal Red Line, Ultra are either trademarks or registered trademarks of Bunn-O-Matic Corporation.
Page 3
Page 3
INTRODUCTION
This equipment will brew a half-gallon batch of coffee into an awaiting dispenser. It can be easily confi gured for 120V 15 amp, 120/208V 20 amp or 120/240V 20 amp. The brewer may have a hot water faucet for allied beverage use. It is only for indoor use on a sturdy counter or shelf.
CONTENTS
Warranty............................................................................................... 2
Contents .............................................................................................. 3
Programming ....................................................................................... 4
Schematic Wiring Diagram ............................................................... 10
Page 4
Page 4
PROGRAMMING
PROGRAMMING THE BREWER
The information in this manual covers only the differences between this model and the standard Axiom. Access to service level 4 is same as standard Axiom. The following function screens are in order of appearance. Each screen will have instructions on how to access, and the procedures to program the various functions of the brewer.
IMPORTANT PROGRAMMING NOTES
- READ CAREFULLY -
To exit the programming mode at any time, press and release "ENABLE BREW ON/OFF" switch located on the front switch panel. The display will return to the MAIN SCREEN. If none of the programming switches are pressed within one minute during the setup of the brewer, the programming of the function screen that is being set will be exited and the display will return to the MAIN SCREEN. Always remember to place an empty server and funnel under the sprayhead when operating the brewer dur­ing the set-up of PULSE BREW, CALIBRATE FLOW and testing the brew valve in TEST OUTPUTS.
Push and hold left "hidden" button to access service program modes.
READY TO BREW
WATER TEMP: 200°
LOCK
SET
PROGRAMMING LOCKOUT SWITCH
(Mounted on main control board)
This switch can be set to prevent access to the programming settings of the brewer. Once all the cor­rect brew settings are programmed, the operator can set the switch to the "LOCK" position to prohibit anyone from changing the settings. With the switch in the "LOCK" position, the programming menus can still be accessed to view the current settings. However, no changes will be saved.
Disconnect brewer from power source before removing any panel!
REVERSE FORWARDREVERSE FORWARD
Page 5
Page 5
SERVICE PROGRAMMING
GLASS FRESH HRS
TEST RFID BOARD
SET DATE/TIME ?
NO YES
ADJUST ALARM
NO VOLUME ? YES
EXPIRATION SECS
(-) 10 (+)
EXPIRATION ALARM
DISABLE ENABLE
FRESHNESS SCAN
NO DONE YES
WARMER MINs PAST
FRESHNESS: 5
ThermalFresh HRS
(-) 2.0 (+)
FRESHNESS TIMEOUT
DISPLAY BREW TIMES
NO YES
Freq&AdjustCaps?
PRE-EXPIRE ALARM
DISABLE ENABLE
NO YES NO YES
(-) .5 (+) NO YES
AXIOM
VERSION xx.xx
Return To Main Screen
Displays Model &
Software Version
Page 6
Page 6
SERVICE PROGRAMMING
MAY 10 2010
MAIN 10:00:00 AM
This allows you to monitor the frequency of the warmer(s) sensing coils.
Also allows you to monitor the adjustment capacitors, which are used to keep the coil frequency at it's nominal value (125.0 khz)
Use the "Brewer" button to toggle between screens.
Press right hidden button to advance to next function.
125.0 0000 * TOP F
125.0 0000 * TOP R
This allows you to read the "age" of any brewed batch in a particular carafe (as long as it is equipped with an RFID chip). The sensor coil will read the chip and brewer will display time of day it was brewed.
DISPLAY BREW TIMES
NO YES
Freq&AdjustCaps?
NO YES
125.0 0000 * MAIN
TEST RFID BOARD
NO YES
This screen will automatically scroll through all warmers.
Press right hidden button to advance to next function.
This allows you to monitor individual sensing coils and RFID board.
RFID CIRCUIT BOARD
VERSION # xx.xx
CONTINUED
Page 7
Page 7
SERVICE PROGRAMMING
If a carafe is placed on a particular warmer, a "box" will appear next to it's indicator. If the box is fi lled (solid) it's not expired yet. If the box is empty, the time is expired. See example: MAIN = expired; Top Front = not expired; Top Rear = expired. Press right hidden button to advance to next function.
10:00:00 AM
M
PRESS ANY SWITCH
TO EXIT
TF TR
WARMER MINs PAST
FRESHNESS: 5
Enables the "FRESHNESS ALERT!" message and sets the expiration time. The expiration time is the amount of time the product is allowed to sit in the glass decanter before an alert message is displayed. DEFAULT: .5 Range: OFF/0.5 - 4.0 hrs
Sets the amount of time the warmers will turn off after an alert message is displayed. DEFAULT: 5 Range: OFF/1 - 30 min
Enables the "FRESHNESS ALERT!" message and sets the expiration time. The expiration time is the amount of time the product is allowed to sit in the thermal server before an alert message is displayed. DEFAULT: 2.0 Range: OFF/0.5 - 4.0 hrs
ThermalFresh HRS
(-) 2.0 (+)
GLASS FRESH HRS
(-) .5 (+)
FRESHNESS SCAN
NO DONE YES
Allows brewer to continually scan the warmer sensor coils and display freshness times.
EXPIRATION ALARM
DISABLE ENABLE
Enable/Disable beeper.
CONTINUED
Page 8
Page 8
ADJUST ALARM 5
ADJUST ALARM
NO VOLUME ? YES
Select "YES" to adjust beeper volume.
Press "+" to increase volume, or "-" to decrease.
- +
Sets the amount of delay between alarm beeps.
EXPIRATION SECS
(-) 10 (+)
SET DATE/TIME ?
NO YES
Select "YES" to set date and/or time.
YEAR 2010
(-) DONE (+)
Press "+" to scroll year forward, or "-" to scroll year back.
MONTH MAY
(-) DONE (+)
Press "+" to scroll month forward, or "-" to scroll month back.
DAY 10
(-) DONE (+)
Press "+" to scroll day forward, or "-" to scroll day back.
CONTINUED
SERVICE PROGRAMMING
Page 9
Page 9
MINUTE 00
(-) DONE (+)
Press "+" to scroll minute forward, or "-" to scroll minute back.
Press "+" to scroll hour forward, or "-" to scroll hour back.
HOUR 10 AM
(-) DONE (+)
SECOND 00
(-) DONE (+)
Press "+" to scroll seconds forward, or "-" to scroll seconds back.
PRE-EXPIRE ALARM
DISABLE ENABLE
Enable/disable the 5 minute warning beep for a carafe about to expire.
EXIT
SERVICE PROGRAMMING
Page 10
Page 10
MAIN ON/OFF SWITCH
(Late Models only)
GRN
Chassis Ground
Earth Ground
OPTIONAL FAUCET HEATER
WHI
WHI
P1, P2, &
P3 ARE
PINS OF A
POLARIZED
THREE-PIN
CONNECTOR.
SOL
SCHEMATIC WIRING DIAGRAM
AXIOM BrewWISE-DV
29077.0021A 06/10 ©2010 BUNN-O-MATIC CORPORATION
P2
P1
P1
FRONT WARMER
P3
BRN/BLK
VIO
WHI
REAR WARMER
BLU-14
BLU-14
BREW STATION WARMER
(CONTROLLED BY ENABLE BREW SW)
LIMIT
THERMOSTAT
BRN/BLK
P2
P3
WHI/RED
WHI/RED
REAR WARMER
FRONT WARMER
WHI
WHI
WHI
WHI
WHI
WHI
WHI
SOL
REFILL
DISPENSE
J1-1
RELAY
J1-5
J1-10
C O N T R O L
P C B
O A R D
BLK
BLK-14
BRN/BLK
BLK-14
BLK-14
WHI/GRN
WHI/GRN
WHI/BLU
WHI/BLU
120V AC 2 WIRE 120/208V AC 3 WIRE 120/240V AC 3 WIRE
SINGLE PHASE
YEL
WHI/VIO
WHI/VIO
VIO
BLK
WHI
YEL
W
H
I
W H
I
CONTROL SWITCH ASSY
J2-1
J2-5
J2-10
B1
STATIC SHIELD
A6
D1
A3 D2 A4 D3 A5 B2 A2 A1
J3-1
J3-3
BRN
BLU
WHI
GRN
LEVEL PROBE (LONG)
LEVEL PROBE (SHORT)
t°
(NOTE – ALL WARMERS ARE NOT
AVAILABLE ON ALL MODELS!)
(LEFT WARMER)
(TOP WARMERS)
J9-1
BLK
CONTROL SWITCH ASSY CODES
2 WARMERS
ON LEFT
2 WARMERS
ON TOP
2 WARMERS
ON RIGHT BREW STATION A3 A3 A3 LEFT FRONT A2 LEFT REAR A1 TOP FRONT A5 TOP REAR A6 RIGHT FRONT A5 RIGHT REAR A6 START BREW A4 A4 A4 LEFT HIDDEN B1 B1 B1 RIGHT HIDDEN B2 B2 B2 “DIGITAL” D1 D1 D1 “BREWER” D2 D2 D2 “CONTROL” D3 D3 D3
L1
L2
BLK
N
RED Model 35
WHI Model 15 & 35
WHI Model 20
J13-1
J13-5
RFID BOARD
TOP REAR WARMER SENSOR
LOWER WARMER SENSOR
GRN BLU
YEL
RED
BRN
ORN
J5-1
J6-1
J7-1
TOP FRONT WARMER SENSOR
J1-5
J1-1
RED
J12-1
BLK
BEEPER
BLK-14
WHI/VIO-14
WHI-14
BLU-14
RED-14
TANK HEATER
1425W
TANK HEATER
2268W
SELECTOR
SWITCH