Buffalo Tools Smoke Alarm User Manual

BUFFALO FILTER
Smoke Evacuation Systems
Operator’s Manual
DELL PlumeSafe®
Smoke Evacuation System
Limited Warranty
For a period of one (1) year following the date of delivery,
BUFFALO FILTER warrants the Dell PlumeSafe®
Evacuation System against any defects in material or
workmanship. For a period of one (1) year following the
date of delivery. BUFFALO FILTER will repair or replace
(at BUFFALO FILTER’S option) the same without charge,
provided that routine maintenance as specified in this
manual has been performed using replacement parts
approved by BUFFALO FILTER. This warranty is void if
the product is used in a manner or for purposes other than
intended.
2004 BUFFALO FILTER
®
595 Commerce Drive
Buffalo, New York USA 14228
(716) 835-7000
Division of Medtek Devices, Inc.
Customer Service: 800-343-2324 (U.S. Only)
The revision level of this manual is specified by the highest revision letter found on either the inside front
cover or enclosed errata pages (if any).
Manual Number DPSEMAN Rev. A
4/2004
Unit Serial Number ______________________
Classified by Underwriters Laboratories, Inc.
with respect to electric shock, fire and mechanical hazards
only in accordance with UL/IEC 60601
9D93
9D93
BUFFALO FILTER® Dell PlumeSafe® Smoke Evacuation System
Table of Contents
Section Title Page
1.0
1.1 Introduction 1.1
1.2 Inspection 1.1
1.3 Operational Information 1.2
1.4 Cautions and Warnings 1.2
SYSTEM DESCRIPTION
& List of Illustrations
1.1
2.0
2.1 System Controls 2.1
2.2
2.3 Set-up and Operation 2.3
2.4 Specifications 2.4
3.0
3.1 General Maintenance Information 3.1
3.2 Cleaning 3.1
3.3 Periodic Inspection 3.1
3.4 Troubleshooting 3.1
4.0
4.1 Equipment Return 4.1
4.2 Ordering Information 4.1
OPERATING INSTRUCTIONS
ViroSafe
MAINTENANCE
CUSTOMER SERVICE
Filter Instructions
2.1
2.2
3.1
4.1
5.0
BUFFALO FILTER® Dell PlumeSafe® Smoke Evacuation System
TERMS & WARRANTY
5.1
n
System Descriptio
Section 1.0
1.1 Introduction
The Dell PlumeSafe® Smoke Evacuation Systems is designed to remove smoke and noxious odors produced by surgical ablation during laser procedures.
The Dell PlumeSafe Smoke Evacuation Systems have been designed with a precision centrifugal action pump. The ultra-quiet motor is used to draw the surgical smoke from the surgical site through the vacuum tubing and into the ViroSafe filter where the surgical smoke is processed by a series of three different filter stages. A single disposable filter is used to simplify the installation and removal during filter changes. The filter is completely enclosed to protect the healthcare personnel from potential contamination during filter changes.
The first stage of filtration is a prefilter whose function is to trap and remove gross particulate and casual fluid.
The second stage of filtration uses the highest grade virgin activated carbon, especially designed for Buffalo Filter for the removal and adsorption of odors and toxic gases produced by burning tissues. These harmful gases may constitute a health hazard to healthcare professionals who are subjected to prolonged exposure. The activated carbon used in the Dell PlumeSafe Smoke Evacuation Systems preferentially removes toxic organic gases rather than water vapor and provides optimal odor removal.
The third stage of filtration is a ULPA (Ultra Low Penetration Air) filter whose high-tech patented design captures particulates and micro-organisms down to 0.12 µm at an efficiency of 99.99995%. Each. ULPA filter is certified before use.
The electronic controls on the face panel of the Dell PlumeSafe smoke evacuation system is designed to be “user friendly” and facilitate easy unit set up and operation. Please refer to Section 2.0 for Operating Instructions.
1.2 Inspection
The Dell PlumeSafe Smoke Evacuator has been thoroughly tested and inspected before shipment from the factory. Please check the unit before using it to insure that no damage has occurred in transit. If damage is evident, please contact BUFFALO FILTER Customer Service at 1-800-343-2324 (US Only) or (716) 835­7000 (International). In addition, if you have ordered kit #DPSWKIT01, please compare the accessories you may have received with the standard accessories list below. If an item is missing, please notify BUFFALO FILTER Customer Service.
Standard Accessories:
Operator’s Manual (1) Power Cord (1)
ViroSafe Dell Filters (2)
Footswitch (1)
Asico Fixation Handpiece (2)
3/8” x 10’ Tubing (2)
Please contact BUFFALO FILTER Customer Service to purchase any additional accessories for your smoke evacuation system.
BUFFALO FILTER® Dell PlumeSafe® Smoke Evacuation System
1.1
BUFFALO FILTER® Dell PlumeSafe® Smoke Evacuation System
1.3 Operational Information
The operational information contained in this section is intended for the customer review of regulatory issues. The information pertains to the use of the products both domestically and internationally:
1. The BUFFALO FILTER Dell PlumeSafe Smoke Evacuation System(s) complies with IEC601.1 electrical specifications in the following systems: 100-120V 50/60Hz,
2. The Dell PlumeSafe Smoke Evacuation System(s) has a classification under the UL2601-1, Clause 5.1 of: CLASS 1 Equipment
3. The Dell PlumeSafe Smoke Evacuation System(s) has an identification under the UL Clause 5.2 according to the degree of protection against electric shock: Type CF Equipment
4. The Dell PlumeSafe Smoke Evacuation System(s) has an identification under the UL Clause 5.3 according to the degree of protection against harmful ingress of water: Ordinary Equipment (enclosed equipment without protection against ingress of water).
5. The Dell PlumeSafe Smoke Evacuation System(s) has a classification under the UL Clause 5.4 according to the method of sterilization or disinfection recommended by BUFFALO FILTER: Unplug Unit. Wipe unit with a damp cloth containing mild disinfectant solution, or soapy water. Wipe dry with a clean cloth. Do not steam sterilize.
6. The Dell PlumeSafe Smoke Evacuation System(s) has a classification under the UL Clause 5.5 according to the degree of safety of application in the presence of flammable anesthetic mixture with air or with oxygen or nitrous oxide: Euipment not suitable for use in the presence of Flammable Anesthetic mixture with air or with oxygen or nitrous oxide.
7. The Dell PlumeSafe Smoke Evacuation System(s) has a classification under the UL Clause 5.6 according to the mode of operation: Continuous Operation.
8. The Dell PlumeSafe is “CE marked”, indicating compliance to the EU Medical Device Directives.
9. Upon request, BUFFALO FILTER will provide the following: Sevice and Repair Instructions, including Circuit Diagrams and Parts List.
10. The fuses on the circuit board are to be serviced by an authorized BUFFALO FILTER technician as follows: 0.0625 Amp 250 Volt fuse
1.4 Cautions and Warnings
Please note that all Cautions and Warnings should be read and understood before any use of this equipment.
This smoke evacuation system should only be operated by personnel who have been properly trained in its operation.
1.2