GEN154 2000 Surge Watts / 1500 Running Watts Portable Generator
FEATURES:
4-Stroke OHV Engine
Recoil Start
2.4 HP Gasoline Engine
Automatic Low Oil Shutdown
1 - 120 Volt A/C Outlet
1 - 12 Volt D/C Outlet
1.8 Gallon Fuel Tank
Engine Run Time: 9 Hours @ 50% Load
2000 Surge Watts / 1500 Running Watts
EPA Approved
GEN154 2000 Surge Watts/1500 Running Watts Portable Generator 2
TABLE OF CONTENTS
RECOGNIZE SAFETY SYMBOLS, WORDS AND LABELS..............................................................................................4
PACKAGE CONTENTS
PACKAGE CONTENTS..........................................................................................................................................9
COMPONENTS.................................................................................................................................................... 10
PREPARING THE GENERATOR FOR USE...................................................................................................................11
Using This Generator For The First Time.............................................................................................................11
Step 1 – Add Oil...........................................................................................................................................11
Step 2 – Add Gasoline.................................................................................................................................12
Step 3 – Ground The Generator...................................................................................................................12
Subsequent Use Of This Generator......................................................................................................................13
Step 1 – Verify Oil Level...............................................................................................................................13
Step 2 – Verify Gas Level ............................................................................................................................13
Step 3 – Ground The Generator...................................................................................................................13
STARTING THE GENERATOR.......................................................................................................................................14
USING THE GENERATOR..............................................................................................................................................15
AC Usage.............................................................................................................................................................15
DC Usage.............................................................................................................................................................17
STOPPING THE GENERATOR......................................................................................................................................18
MAINTENANCE/CARE....................................................................................................................................................18
Recommended Maintenance Schedule................................................................................................................18
Cleaning The Generator.......................................................................................................................................18
Checking The Oil Level.........................................................................................................................................19
Changing/Adding Oil.............................................................................................................................................19
Air Filter Maintenance...........................................................................................................................................20
Spark Plug Maintenance.......................................................................................................................................20
Emptying The Fuel Tank.......................................................................................................................................20
STORAGE/TRANSPORT PROCEDURES......................................................................................................................21
TROUBLESHOOTING.....................................................................................................................................................22
PARTS DIAGRAM...........................................................................................................................................................23
GEN154 2000 Surge Watts/1500 Running Watts Portable Generator 3
RECOGNIZE SAFETY SYMBOLS, WORDS AND LABELS
What You Need to Know About Safety Instructions
Warning and Important Safety Instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur. Common sense, caution and care must be exercised when operating or cleaning tools and equipment.
Always contact your dealer, distributor, service agent or manufacturer about problems or conditions you do not understand.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
CAUTION used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in property damage.
GEN154 2000 Surge Watts/1500 Running Watts Portable Generator 4
Notice Regarding Emissions:
Engines certified to comply with California and U.S. EPA emission regulations for SORE (Small Off Road Equipment) are certified to operate on regular unleaded gasoline and may include the following emission control systems: Three-Way Catalyst (TWC) (if equipped), and Engine Modifications (EM).
Legal Requirements:
Federal and/or State Occupational Safety and Health Administration (OSHA) regulations, local codes, and/or ordinances may apply to the intended use of this generator. Consult a qualified electrician, electrical inspector, and/or the local agency having jurisdiction. Some areas require generators to be registered with local utility companies. Additional regulations may apply if this generator will be used at a construction site.
IMPORTANT SAFETY INSTRUCTIONS
STOP!
Before using this generator and if you have any questions regarding the hazard and safety notices listed in this manual and/or on this generator, call 1-888-287-6981, Monday - Friday, 8 AM - 4 PM Central Time.
Carbon Monoxide Gas: When in operation, the exhaust from this generator contains poisonous carbon monoxide gas. Carbon
monoxide gas is both odorless and colorless AND may be present even if you do not see or smell gas. Breathing this poison gas can lead to headaches, dizziness, drowsiness, loss of consciousness and eventually death.
• USE THIS GENERATOR ONLY OUTDOORS IN NON-CONFINED AREAS. DO NOT SECURE THE GENERATOR WITH A CHAIN OR ROPE, AS THIS WILL MAKE IT DIFFICULT TO MOVE IN AN EMERGENCY.
• Keep at least several feet of clearance on all sides to allow proper ventilation for this generator.
Chemicals: According to the State of California, the exhaust from this generator contains chemicals known to cause cancer, birth
defects, or other reproductive harm.
Flammable Gasoline: This generator may emit highly flammable and explosive gasoline vapors, which can cause severe burns or
even death. A nearby open flame can lead to an explosion even if not directly in contact with gasoline.
• Do not operate this generator near open flame.
• Do not smoke near this generator.
• Always operate this generator on a firm, level surface.
Gasoline is highly flammable and explosive. Handling fuel can result in serious injury or burns.
• Always shut down this generator before refueling. Refuel in a well-ventilated area. Keep heat, sparks and flame away while refueling and away from the location where gasoline is stored. Never refuel indoors where gasoline fumes may reach flames and/or sparks.
• Allow this generator to cool for at least 2 minutes before removing the fuel tank cap. Loosen the cap slowly to relieve pressure in the fuel tank. Avoid spilling fuel.
• Do not fill the fuel tank above the upper limit line. Gasoline may expand during operation. Do not fill to the top of the tank.
• Always check for spilled gasoline and immediately wipe it up before starting this generator.
• Empty the fuel tank before storing or transporting this generator.
• Always handle fuel outdoors.
• Before transporting, turn the fuel valve to the “OFF” position and disconnect the spark plug.
GEN154 2000 Surge Watts/1500 Running Watts Portable Generator 5
Powerful Voltage: This generator produces powerful voltage, which can result in electrocution.
• ALWAYS ground this generator before using it. (See “Ground the Generator” section in this manual).
• Only electrical devices should be plugged into this generator, either directly or with an extension cord. NEVER connect a building electrical system to this generator without a qualified electrician. Such connections must isolate generator power from utility power and comply with local electrical laws and codes. Failure to comply can create a back feed into utility lines creating an electrocution hazard, which may result in serious injury or death to utility workers. Such a back feed may cause this generator to explode, burn and create fires when utility power is restored.
• Use a ground fault circuit interrupter (GFCI) in highly conductive areas such as metal decking or steel work. GFCIs are available in-line with some extension cords.
• Do not use this generator in wet conditions (rain, snow, active sprinkler system, wet hands, etc.). Always keep this generator dry and operate it with dry hands.
• Do not touch bare wires or outlets (receptacles).
• Do not allow children or non-qualified persons to operate this generator.
High Temperatures: This generator produces heat when in operation. Temperatures near the exhaust can exceed 150 Degrees
Fahrenheit (65 Degrees Celsius).
• Do not touch hot surfaces. Observe all warning placards on this generator denoting hot surfaces.
• Allow this generator to cool for several minutes after use before touching the engine, muffler or other areas that are hot during operation and before storing indoors.
• Hot exhaust may ignite some materials. Keep flammable materials away from this generator.
• Keep at least several feet of clearance on all sides of this generator during operation. Do not enclose this generator in any structure.
Usage: Misuse of this generator can damage it or shorten its life.
• Use this generator only for its intended purpose.
• Operate this generator only on a dry, level surface. Do not secure the generator with a chain or rope, which would prevent it from being moved in an emergency.
• Allow this generator to run for several minutes before connecting any electrical devices.
• Promptly turn off any malfunctioning devices and disconnect them.
• Do not operate an excessive number of electrical devices in excess of the wattage capacity of this generator.
• Do not turn on electrical devices until after they are connected to this generator.
• Turn off all connected electrical devices before stopping this generator.
GEN154 2000 Surge Watts/1500 Running Watts Portable Generator 6
GEN154 2000 Surge Watts/1500 Running Watts Portable Generator 7
In addition to the previously described safety information, familiarize yourself with all safety and hazard placards on this generator.
GEN154 2000 Surge Watts/1500 Running Watts Portable Generator 8