Buffalo Forge Type FB Electric Blowers Other

Page 1
y
o
rf\
d
£ u.
<
S3
Electric Blowers
<
a
i
r
66
t\
^
(TYPE "FB")
Variable and Constant Speed
i
{(
UJITAL&
9
No. 2-E Variable Speed Blower
with Regulator
"Buffalo Blowers are more of similar type, and cient small units on of uses.
The variable speed type is made in two sizes only—Nos. 2-E and 2-EH. These cipally for supplying air to forge fires, as well as for other intermittent service. They operate on any
” Variable and Constant Speed Electric
widely used than any other blower
are recognized as the most effi- the market, for a great variety
are used prin
Constant Speed Blower
No.
6-E Constant Speed Blower
Note substantial construction
110 or 220 volt direct current or 25, 40, 50 or 60 cycle single phase alternating current and vided with an
enclosed six speed regulator. Wire and plug are furnished with each outfit, as shown above.
Cf
Buffalo
” Constant Speed Blowers
are made in
eight sizes with capacities ranging above 4000 cubic feet of air per minute and for pressures up to pound. The larger sizes of these blowers ular for blowing oil and gas furnaces and also for cupola work.
Freauently pressures higher than one pound required for gas boosting and other industrial prob lems. We have three additional sizes of direct nected electric blowers for these special problems. Full information furnished on request.
Individual blowers for oil or gas furnaces located some distance apart are more economical than a larger, higher pressure fan, as the pressure required to overcome the friction of a long duct is frequently half the total pressure requirements.
are pro-
are pop-
one
are
con
>
>
21
<T
2
P
UJ
eu
Page 2
The smaller sizes are used for blowing small furnaces, for remov ing scale from power hammers, and chips in metal and woodworking op erations, as well as for exhausting from grinding and buffing wheels.
They are of the moderately high speed, high efficiency type, with nar row blades, heavy cast iron housings and substantial bases. The larger sizes, being d e
s i g n e d
es pecially for use with standard motors,
have
adjustable steel
used with a large oil-burning furnace
No. 6-E Blower
bases motors of any
to
fit
make, and the blower wheel is so constructed that it can be mounted di rectly on the motor shaft of a standard motor without exten
sion.
The housings are reversible and may be readily changed from right to left hand. The multi-rating tables on pages 3 and 4 show the capacities at different speeds, the pressure
at
which the air is delivered,
Eighteen "Buffalo
Blowers on one shipment to a large oil company.
” No. 6-E
\\
and the horsepower requir ed. It is possible to still
further vary the capacity by changing the diameter of the wheel.
No. 5-E Blower with flanged
inlet and outlet for gas booster service
All parts are carried in stock, and shipment on all sizes can be made promptly due to the fact that stand
ard stock motors are used.
"Buffalo
” "E
” Blowers will be
found in every branch of industry.
Railroads in particular use a large number on oil-burning
blacksmith
forges, cupolas, furnaces, etc.
Page 3
S3
id
l
•'Vfc
fl
M
L
Size
2-E
2-EH
3-E
4-E
4 /2-E
5-E
5/2-E
6-E
L -
H.P.
1/30
1/8
1/4
1/2
I
A
3 3
4 4/2
*
5
*
5/2
*
7
*
7/4
B
3
3
4
5 5/2
6/8
7/8
8
C
5/s 5/s
6
7/4 7/4
IO/2
12/4
13/8
* H.P. for the larger sizes depends on
D
l/
1 Vi
1/4
1 Vs
2
2U
3 fs
3
E
6 3
/4
2
6/4
7 Vs
9/s
9 Vs
/a
1
3 Vs
15
13
17/4
/a
F
6
6
7/8
8 Vs
9/2
12
13/4
15
capacities and pressures.
G
6^8
6/s
7/4 9/s
9/s
12/4
14 Vs
16 l
A
Multi-Rating Tables
H
8 Vs
8’k
9/2
107/s
12
15
17/2
19
K
8 Vs
8 Vs
8/4
13
14/4
12
19
19
L
9/s
914
9 Vs
11/2
10
11 Vs
16/4
16/s
M
13
14H
20
21
-I—h
r
Motor
Type "FB" Blowers
Cap.
30 50 70
1 30
No.
0
2-E BLOWER
1750
R.
P. M.
INCHES
Static Total
.9
.9
.S21 .730 .593
0
.843 .790 .720 .422
Capacities and Statistic Pressures at 70° F and 29.92" Bar.
Nos. 2-E, 2-EH, 3-E and 4-E
No.
150 225 2S5
315
360
390
0
45
90
3-E BLOWER
3400 R. P. M.
INCHES
Static Total
4.30
4.30
4.37
4.33
4.37
4.29
4.21
4.01
3.74
3.27
3.22
2.46
2.94
2.05
2.51
1.30
2.20
0.78
H.P.
.075 .092 .121
.172 | 300 .248 .306 I 570
.331 1 .363 | .3 SO !
H.P.
.0065
.0102 .0143 .0180
.0270
No. 2-EH BLOWER
3400 R P. M.
INCHES
Stacie
Cap.
3.40
0
3.25
3.09
2.75
2.07
1.26 .00
100 150 200 250
30 60
Total
3.40
3.30
3.17
2.98
2.64
2.21
1.50
H P Cap.
.045 .058
.075 .104 .136 .163 .201
No. 4-E BLOWER
3400
ISO
450
646
INCHES
4.68
0
4.60
90
4.45
4.00
2.72
1.20
Cap. Static Total
.00
R.
P. M.
H.P.
.153
4.65 .183
4.65 .247
4.57 .356
4.31
.497
3.43 .603
2.40
-67S
1.60
See next page.
Page 4
f
H
y
su
S
rf
z
MULTI-RATING TABLES (Continued)
< <
3400 R. P. M.
Cap. Static Total
200 400 600
800 1000 1 120
INCHES
8.70
50
8.63 8.80
8.12 8.67
6.87 8.03 1.20
4.68
1.93 5.27 1.84 .00 4-18 2 03
8.72 .38
6.83
Cap.
100 300 500 700
1000 1400 1875
H.P.
.56 .88
1.52
3400 R. P. M.
INCHES
Static Total
18.39 18.45
18.80 19.02
18.85 19.40
18.17 19.28
15.73 18.01
10.00 14.51
7.90
.00 965
No. 434-g ELECTRIC BLOWER
1750 R. P. M.
2.30 2.31 .051
25
2.28
100
2.16
200
1.86 2.15 .160
300
1.30 1.85 .202
500
INCHES
.62 1.46 .244 .00 1.1 1 .278
Cap. Static Total
400 240
580
H.P.
2.33 .075
2.30 .1 17
1440 R. P M.
Cap. Static Total
INCHES
20 1.56 1.56 80
1.54 1.57 .041
160
1.47 1.55 .064
240
1.29 1.47 320 400 475
.94 1.28 .1 10 .48 1.02 .133 .00 .75 .155
H.P.
.029
.087
Cap. Static Total
120 180
300 375
No. 5-E ELECTRIC BLOWER
H.P.
1.38 192
2.69
3.42
4.53
6.00
7.78
1750 R. P. M.
Cap.. Static Total H.P.
420 600 780
INCHES
60
4.89 4.92
180
4.99
300
4.93
4.60 5.03 3 66 4.47 .705
2.1 5 .00
5.07
5.1 5 .41 1
3.48
2.09
.199 .295
.530
.881
1.065
1440 R. P. M.
Cap. Static Total
225 325
475
625 790
INCHES
3.28
25
125
3.36 3.42 .149
3.35 3.47 .216
3.22
2.56
1.55
.00
3.29
3 44 .281
3.08 .381
2.44
1 40 .595
15
60
1140 R. P. M.
INCHES
.98 .97 .93 .83 .63 .38 .00
H.P.
.105
.481
H.P
.98 .014 .99 .020
.98 .031 .93 .042 .83 .052 .69 .063 .47 .077
3400 R. P. M.
Cap. Static Total H.P.
1000
1 500 2000 2500 3340
Cap. Static Total
750
1500 2100 3000
3600 4400
INCHES
100 21.25 500 21.95 22 17 3.82
21.80 22.68
20.00
16.90 20 40 10.05
11.90 17.38 12.25 .00 9.75 15.8
3400 R. P M.
INCHES
0
25.0 25.0 3.75
27.3 27.6 6.25
26.6 27.7 9.90
24.3 26.6 12.90
17.3 22.0
10.7 17.4 20.55
0.0 10.1 24.65
21.26
21.97
7.90
17
2.72
5.77
H P
No.
1750 R. P M.
Cap. Static Total H.P.
300
600
800 1000 1 300 1720
INCHES
0
5.55 5.55 .37
5.83 5.91 55 5 68
5.25 5.81 1.10
4 55 5.42 1.33
3.05 4.53 1.68
No. 6-E ELECTRIC BLOWER
1750 R. P. M.
Cap. Static Total H.P.
375
750
1050
50
1500 1 800
2265
INCHES
0
6.63 6.63
7.25 7.32
7.10 7.38 1.32
6.51 7.10 1.73
4.81 6 00 2.33 3 1 5 4.84 2.83
•00 2 73 3.36
5H-E ELECTRIC BLOWER
6.00
00
2.59
.87
2.16
.51 .84
1440 R. P M.
Cap. Static Total
1000 1250 14 15
Cap. Static Total H.P.
300 600 840
1200 1480
1860
INCHES
0
3.76
250
3.95 4.01 .31
500
3.80 4 02 .49
750
3.26 3.75 .68
2.38
1.08 2.45 1.07 .00 1.75 1.20
1440 R. P. M.
INCHES
0
4.50 4 50 .28
4.91 4.95
4.83 4.99 4 47 4.85 .94
3.40 4.16 1.26 2 13 3.28 1.52
.00 1.83 1.87
3.76
3.26 .88
1 140 R. P. M.
H.P.
Cap. Static Total
.193
.47 .72
0
2 35 2.35 .096
200
2 46 2.49 .159
400
2.38 2.52 .249
600
2.05 2.36
800 1000 1 120
Cap. Static Total H.P.
1000 1200 1475
1 48 2.04 .440
1140 R. P M.
0
2.81 2.81
250
3.07 3.1 1
500
3.00 3.12
700
2-73 2.99
1.96 2.48
1.22 1.97
INCHES
.64 1.52 .537 .00 1 10 5.92
INCHES
.00 1 15
Motor side of No. 5-E Blower showing sturdy construction. Note
that motor support is easily shifted to accommodate any stock motor.
Housing is reversible to eight positions of discharge, and may be
changed quickly.
Heavy construction of all parts of the blower, and a balanced
rotor, eliminate vibration.
H.P.
.344
14 .23 .37 .48 .66 .77
.93
Buffalo, N. Y.
In Canada: Canadian Blower & Forgo Co., Ltd., Kitchener, Ont.
BRANCHES IN ALL PRINCIPAL CITIES
Form 2386-A--5m--6-34
> >
*
z
?
o
CL
M
Loading...