Page 1

y
o
rf\
d
£
u.
<
S3
Electric Blowers
<
a
i
r
66
t\
^
(TYPE "FB")
Variable and Constant Speed
i
{(
UJITAL&
9
No. 2-E Variable Speed Blower
with Regulator
"Buffalo
Blowers are more
of similar type, and
cient small units on
of uses.
The variable speed type is made in two sizes
only—Nos. 2-E and 2-EH. These
cipally for supplying air to forge fires, as well as
for other intermittent service. They operate on any
” Variable and Constant Speed Electric
widely used than any other blower
are recognized as the most effi-
the market, for a great variety
are used prin
Constant Speed Blower
No.
6-E Constant Speed Blower
Note substantial construction
110 or 220 volt direct current or 25, 40, 50 or 60
cycle single phase alternating current and
vided with an
enclosed six speed regulator. Wire
and plug are furnished with each outfit, as shown
above.
Cf
Buffalo
” Constant Speed Blowers
are made in
eight sizes with capacities ranging above 4000 cubic
feet of air per minute and for pressures up to
pound. The larger sizes of these blowers
ular for blowing oil and gas furnaces and also for
cupola work.
Freauently pressures higher than one pound
required for gas boosting and other industrial prob
lems. We have three additional sizes of direct
nected electric blowers for these special problems.
Full information furnished on request.
Individual blowers for oil or gas furnaces located
some distance apart are more economical than a
larger, higher pressure fan, as the pressure required
to overcome the friction of a long duct is frequently
half the total pressure requirements.
are pro-
are pop-
one
are
con
>
>
21
<T
2
P
UJ
eu
Page 2

The smaller sizes are used for
blowing small furnaces, for remov
ing scale from power hammers, and
chips in metal and woodworking op
erations, as well as for exhausting
from grinding and buffing wheels.
They are of the moderately high
speed, high efficiency type, with nar
row blades, heavy cast iron housings
and substantial bases. The larger
sizes, being
d e
s i g n e d
es
pecially for use
with standard
motors,
have
adjustable steel
used with a large oil-burning furnace
No. 6-E Blower
bases
motors of any
to
fit
make, and the
blower wheel is so constructed that it can be mounted di
rectly on the motor shaft of a standard motor without exten
sion.
The housings are reversible and may be readily changed
from right to left hand. The multi-rating tables on pages
3 and 4 show the capacities at different speeds, the pressure
at
which the air is delivered,
Eighteen "Buffalo
Blowers on one shipment to
a large oil company.
” No. 6-E
\\
and the horsepower requir
ed. It is possible to still
further vary the capacity
by changing the diameter
of the wheel.
No. 5-E Blower with flanged
inlet and outlet for
gas booster service
All parts are carried in stock, and
shipment on all sizes can be made
promptly due to the fact that stand
ard stock motors are used.
"Buffalo
” "E
” Blowers will be
found in every branch of industry.
Railroads in particular use a large
number on oil-burning
blacksmith
forges, cupolas, furnaces, etc.
Page 3

S3
id
l
•'Vfc
fl
M
L
Size
2-E
2-EH
3-E
4-E
4 /2-E
5-E
5/2-E
6-E
L -
H.P.
1/30
1/8
1/4
1/2
I
A
3
3
4
4/2
*
5
*
5/2
*
7
*
7/4
B
3
3
4
5
5/2
6/8
7/8
8
C
5/s
5/s
6
7/4
7/4
IO/2
12/4
13/8
* H.P. for the larger sizes depends on
D
l/
1 Vi
1/4
1 Vs
2
2U
3 fs
3
E
6 3
/4
2
6/4
7 Vs
9/s
9 Vs
/a
1
3 Vs
15
13
17/4
/a
F
6
6
7/8
8 Vs
9/2
12
13/4
15
capacities and pressures.
G
6^8
6/s
7/4
9/s
9/s
12/4
14 Vs
16 l
A
Multi-Rating Tables
H
8 Vs
8’k
9/2
107/s
12
15
17/2
19
K
8 Vs
8 Vs
8/4
13
14/4
12
19
19
L
9/s
914
9 Vs
11/2
10
11 Vs
16/4
16/s
M
13
14H
20
21
-I—h
r
Motor
Type "FB" Blowers
Cap.
30
50
70
1 30
No.
0
2-E BLOWER
1750
R.
P. M.
INCHES
Static Total
.9
.9
.S21
.730
.593
0
.843
.790
.720
.422
Capacities and Statistic Pressures at 70° F and 29.92" Bar.
Nos. 2-E, 2-EH, 3-E and 4-E
No.
150
225
2S5
315
360
390
0
45
90
3-E BLOWER
3400 R. P. M.
INCHES
Static Total
4.30
4.30
4.37
4.33
4.37
4.29
4.21
4.01
3.74
3.27
3.22
2.46
2.94
2.05
2.51
1.30
2.20
0.78
H.P.
.075
.092
.121
.172 | 300
.248
.306 I 570
.331 1
.363 |
.3 SO !
H.P.
.0065
.0102
.0143
.0180
.0270
No. 2-EH BLOWER
3400 R P. M.
INCHES
Stacie
Cap.
3.40
0
3.25
3.09
2.75
2.07
1.26
.00
100
150
200
250
30
60
Total
3.40
3.30
3.17
2.98
2.64
2.21
1.50
H P Cap.
.045
.058
.075
.104
.136
.163
.201
No. 4-E BLOWER
3400
ISO
450
646
INCHES
4.68
0
4.60
90
4.45
4.00
2.72
1.20
Cap. Static Total
.00
R.
P. M.
H.P.
.153
4.65
.183
4.65
.247
4.57
.356
4.31
.497
3.43
.603
2.40
-67S
1.60
See next page.
Page 4

f
H
y
su
S
rf
z
MULTI-RATING TABLES (Continued)
<
<
3400 R. P. M.
Cap. Static Total
200
400
600
800
1000
1 120
INCHES
8.70
50
8.63 8.80
8.12 8.67
6.87 8.03 1.20
4.68
1.93 5.27 1.84
.00 4-18 2 03
8.72 .38
6.83
Cap.
100
300
500
700
1000
1400
1875
H.P.
.56
.88
1.52
3400 R. P. M.
INCHES
Static Total
18.39 18.45
18.80 19.02
18.85 19.40
18.17 19.28
15.73 18.01
10.00 14.51
7.90
.00 965
No. 434-g ELECTRIC BLOWER
1750 R. P. M.
2.30 2.31 .051
25
2.28
100
2.16
200
1.86 2.15 .160
300
1.30 1.85 .202
500
INCHES
.62 1.46 .244
.00 1.1 1 .278
Cap. Static Total
400 240
580
H.P.
2.33 .075
2.30 .1 17
1440 R. P M.
Cap. Static Total
INCHES
20 1.56 1.56
80
1.54 1.57 .041
160
1.47 1.55 .064
240
1.29 1.47
320
400
475
.94 1.28 .1 10
.48 1.02 .133
.00 .75 .155
H.P.
.029
.087
Cap. Static Total
120
180
300
375
No. 5-E ELECTRIC BLOWER
H.P.
1.38
192
2.69
3.42
4.53
6.00
7.78
1750 R. P. M.
Cap.. Static Total H.P.
420
600
780
INCHES
60
4.89 4.92
180
4.99
300
4.93
4.60 5.03
3 66 4.47 .705
2.1 5
.00
5.07
5.1 5 .41 1
3.48
2.09
.199
.295
.530
.881
1.065
1440 R. P. M.
Cap. Static Total
225
325
475
625
790
INCHES
3.28
25
125
3.36 3.42 .149
3.35 3.47 .216
3.22
2.56
1.55
.00
3.29
3 44 .281
3.08 .381
2.44
1 40 .595
15
60
1140 R. P. M.
INCHES
.98
.97
.93
.83
.63
.38
.00
H.P.
.105
.481
H.P
.98 .014
.99 .020
.98 .031
.93 .042
.83 .052
.69 .063
.47 .077
3400 R. P. M.
Cap. Static Total H.P.
1000
1 500
2000
2500
3340
Cap. Static Total
750
1500
2100
3000
3600
4400
INCHES
100 21.25
500 21.95 22 17 3.82
21.80 22.68
20.00
16.90 20 40 10.05
11.90 17.38 12.25
.00 9.75 15.8
3400 R. P M.
INCHES
0
25.0 25.0 3.75
27.3 27.6 6.25
26.6 27.7 9.90
24.3 26.6 12.90
17.3 22.0
10.7 17.4 20.55
0.0 10.1 24.65
21.26
21.97
7.90
17
2.72
5.77
H P
No.
1750 R. P M.
Cap. Static Total H.P.
300
600
800
1000
1 300
1720
INCHES
0
5.55 5.55 .37
5.83 5.91 55
5 68
5.25 5.81 1.10
4 55 5.42 1.33
3.05 4.53 1.68
No. 6-E ELECTRIC BLOWER
1750 R. P. M.
Cap. Static Total H.P.
375
750
1050
50
1500
1 800
2265
INCHES
0
6.63 6.63
7.25 7.32
7.10 7.38 1.32
6.51 7.10 1.73
4.81 6 00 2.33
3 1 5 4.84 2.83
•00 2 73 3.36
5H-E ELECTRIC BLOWER
6.00
00
2.59
.87
2.16
.51
.84
1440 R. P M.
Cap. Static Total
1000
1250
14 15
Cap. Static Total H.P.
300
600
840
1200
1480
1860
INCHES
0
3.76
250
3.95 4.01 .31
500
3.80 4 02 .49
750
3.26 3.75 .68
2.38
1.08 2.45 1.07
.00 1.75 1.20
1440 R. P. M.
INCHES
0
4.50 4 50 .28
4.91 4.95
4.83 4.99
4 47 4.85 .94
3.40 4.16 1.26
2 13 3.28 1.52
.00 1.83 1.87
3.76
3.26 .88
1 140 R. P. M.
H.P.
Cap. Static Total
.193
.47
.72
0
2 35 2.35 .096
200
2 46 2.49 .159
400
2.38 2.52 .249
600
2.05 2.36
800
1000
1 120
Cap. Static Total H.P.
1000
1200
1475
1 48 2.04 .440
1140 R. P M.
0
2.81 2.81
250
3.07 3.1 1
500
3.00 3.12
700
2-73 2.99
1.96 2.48
1.22 1.97
INCHES
.64 1.52 .537
.00 1 10 5.92
INCHES
.00 1 15
Motor side of No. 5-E Blower showing sturdy construction. Note
that motor support is easily shifted to accommodate any stock motor.
Housing is reversible to eight positions of discharge, and may be
changed quickly.
Heavy construction of all parts of the blower, and a balanced
rotor, eliminate vibration.
H.P.
.344
14
.23
.37
.48
.66
.77
.93
Buffalo, N. Y.
In Canada: Canadian Blower & Forgo Co., Ltd., Kitchener, Ont.
BRANCHES IN ALL PRINCIPAL CITIES
Form 2386-A--5m--6-34
>
>
*
z
?
o
CL
M