Bticino D45 System Quick Start Manual

D45 System
Hands-free colour internal unit
Description
Hands-free colour internal unit with 7” TFT LED (16/9 format), SOS function, door lock release and scrolling EP activation.
Technical data
Voltage 18 Vdc - 30 V Stand-by current absorption 13 mA (30 V) Operating current absorption 90 mA (30 V) Monitor resolution: 800 x 480 dpi
Side and front view
1 2 43
Rear view
322052
5
6 7 8
12 11 10 913
14 15 1716
225 mm 25,5 mm
22 21 20 1819
LegendDimensional data
1. Communication LED
2. Information / Alarm LED
3. Display screen
4. Setup key and Enter key
5. Microphone
6. Sound control knob
7. Brightness control knob
8. Contrast control knob
9. Unlock key
10. Monitor key / Internal call key
11. Management center key / Message key
12. Hands-free talk key and One-stroke Guard key
13. Loudspeaker
14. Alarm sensor anti-removal connector
15. Download connector
16. Doorbell interface (Small Entrance Unit interface)
17. Master and slave pin
18. Bus connector
19. Lock remover interface
20. Emergency alarming interface
21. Sensor connector
22. Anti-removal switch
EN
24/03/2016BT00875-a-
1
Hands-free colour internal unit
Configuration
322052
Intercom
1.1 Internal unit calls management center:
In stand-by status, press the ” management center key” and wait for the answer. Press the “ answer key” to end the call.
1.2 Internal unit calls other internal units: In stand-by status, press and hold the “ monitor key” (1.5 – 2.5 s) and wait for the answer. Press the “ answer key” to end the call.
Configuration setting
2.1 Pushbutton function
Inside the set-up menu the keys have the following functions:
“Hands-free talk key and One-stroke Guard key”: set the lnternal unit address thousands value set the Guard alarm password thousands value
“Management center key / Message key”: set the lnternal unit address hundreds value set the Guard alarm password hundreds value
“Monitor key / Internal call”: set the internal unit address tens value set the number or apartment tens value set the Guard alarm password tens value
“Unlock Key”: sets the Internal unit address units value sets the number of apartments units value sets the Guard alarm password units value
The value is set by the number of presses. Each time the pushbutton is pressed the number increases sequentially and the input range is 0-9 (i.e. no press = 0, 8 presses = 8)
“Setup key and Enter key”:
confirmation of single user setting
If the digit setting is not confirmed by pressing the “ Setup key and Enter key”, it is reset to zero. If the digit setting is more than 9, it is reset to more than 9, it is reset to zero.
E.g: to set address 2014 Press the “ Hands-free talk key and One-stroke Guard key” twice 2014 Do not press the “ Management center key / Message key” 2014 Press the “ Monitor key / Internal call” once 2014 Press the “ Unlock Key” four times 2014 Press the “ setup key and Enter key” once to confirm 2014
Acoustic feedback: 1 Long beep: successful operation 3 Short beep: aborted operation
2.2 Setup menu
2.2.1 Installation setup
- Enter the setup menu: in stand-by and alarm disabled status, press and hold the “ Unlock key”, then input password 1010 or 6868 and press the “ Setup key and Enter key”.
2.2.1.1 Set room number:
- Enter the set room number menu using code 11 (press the “ Monitor key / Internal call” once and the “ Unlock Key” once)
- Confirm (press the “ Setup key and Enter key” once)
- Set the room number (FFII) by pressing the pushbutton and confirm ( “ Setup key and Enter key” once).
2.2.1.2 Set number of apartments per floor:
- Enter the set room number menu using code 12 (press the “ Monitor key / Internal call” + once and the “ Unlock Key” twice)
- Confirm (press the “ setup key and Enter key” once)
- Set the number of apartments (##) by pressing the pushbutton and confirm (press the Setup key and Enter key” once).
2.2.2 End-user setup
- Enter the setup menu: in stand-by status, press and hold the “ Setup key and Enter key”
- Set password: by using pushbuttons (default is 2000)
- Confirmation of single user setting: press the “ Setup key and Enter key” once
- Confirm and quit the setup menu: press and hold the “ Setup key and Enter key”
2.3 Modifying the password:
- Enter the setup menu (press and hold the “ Setup key and Enter key”), then input password 2000 to enter the setup installation menu after a long beep.
- lnput 99 (press the “ Monitor key / lnternal call” nine times and the “ Unlock Key” nine times)
- Confirm (press the “ Setup key and Enter key” once)
- Wait for a long sound and input a new four-digit password
- Re-input the four-digit password to confirm
- Long sound: the change of password was successful
- Three short sounds: the change of password was not successful.
2.3.1 Recovering the default password:
- Press and hold the “ Setup key” and “ Unlock Key” ), simultaneously until a long sound is heard. The default password (2000) is recovered.
- The lnternal Unit will warn the management centre.
1. Alarm function and operation: alarms include the emergency (SOS) alarm, anti-detaching alarm and 4-zone guard alarm.
3.1 Emergency alarm (SOS): press an external SOS alarm switch or a “ Hands-
free talk key and One-stroke Guard key” on the Internal unit.
3.2 Anti-detaching alarm: if the internal unit is removed or the anti-detaching interface is activated, the internal unit automatically informs the management centre.
3.3 Enable the guard alarm:
- Press and hold the “ Hands-free talk key and One-stroke Guard key” until a long tone is heard.
- Insert the password (default 2000) by means of the pushbutton.
- Confirm (press the “ Setup key and Enter key” once) Note: Guard zones 1 and 2 are theft alarm guard zones and guard zones 3 and 4 are fire alarm guard zones.
2. Alarm function and operation specification
4.1 Enable the defence area
4.1.1 Enabled by the shortcut key: in stand-by status, press the “ Setup” key until a long tone is heard, input the correct password (the password is 2000, press “ Thousands” twice) , then press “ OK”. The internal unit enters the main setup menu after a long tone is heard; if any defence areas are enabled, press the “ shor tcut key” to enable all the defence areas which are connected to the alarm sensors. Mean while the enabled defence area “ LED” will be ON and flash once. A long tone will be heard if all the defence areas have been enabled. Otherwise, 3 short tones will be heard.
24/03/2016BT00875-a-EN
2
Loading...
+ 2 hidden pages