BT Home monitor keypad Installation And User Manual

Introduction
The BT Home Monitor Keypad acts as a wireless remote control for your BT Home Monitor VP1000 system.
Carry with you around the home to turn your security system on and off, or change settings, at the touch of a button. The panic button functions allow you to call for help in an emergency, ensuring that nominated contacts receive alerts by telephone, text message and e-mail.*
You can have 2 Keypads registered with the Control Panel. They provide a useful way to turn your system on and off if your Control Panel is located somewhere other than your usual entry and exit point.
Inside The Box
• 1 Wireless Keypad (Battery Included)
• Mounting Equipment
• Installation Guide
Before You Begin
Be sure you have set up your BT Home Monitor VP1000 system according to the instructions shown in the main User Guide.
Before you proceed, check that your Control Panel says BT HOME MONITOR or READY. If it does not, please consult the troubleshooting section of the main User Guide.
Note that only the MASTER CODE owner can add an accessory.
Installation
To add a new Keypad, follow these instructions.
Step 1 – Insert The Battery
1. Remove the wall mounting bracket from the Keypad by pushing downward.
2. Slide down the battery cover.
3. Insert the battery (observing polarity + and –).
4. Replace the battery cover.
Step 2 – Register The Keypad
At the Control Panel, follow these instructions:
PRESS DISPLAY
Until the display shows SYSTEM PROFILE.
Enter your MASTER CODE – if you have not selected a personal PIN number, this will be the default setting – 2580.
Until the display shows ADD / DEL KEYPAD 1.
Display shows 1-WAY KP NO:–
Enter the Keypad number you want e.g. 1, or press NEXT to find the next available Keypad location.
Display shows ACTIVATE NOW.
Press the button (next to
0) on the Keypad
for two seconds. You will hear a confirmation melody.
Display shows KEYPAD NO: (number), e.g. ■. The Keypad is now registered. Choose either:
To move to the next Keypad. Or:
Three times, then <OK> to exit and return to READY.
Please remember to update your personal online account with this information so that your monitoring service can report information accurately.
BT Home Monitor Keypad VP
Installation and User Guide
BT Home Monitor Keypad VP – Edition 08 – 21.03.03
1
NEXT
SHOW / OK
NEXT
SHOW / OK
SHOW / OK
NEXT
HOME
Downloaded from www.ukpanels.com
Step 3 – Wall Mounting The Keypad
If you wish to mount the Keypad on a wall surface, use these instructions.
1. Hold the bracket against the wall and mark the drill points through the two screw holes.
2. Drill two holes where you have marked the wall.
3. Insert the wall plugs.
4. Screw the bracket to the wall with the screws provided.
5. The Keypad slides into the bracket and the clips hold it in place.
Step 4 – Test The Keypad
1. Stand about 3m away from the Control Panel and turn the system ON by pressing the button.
2. Enter your User Code (if you have not selected a personal PIN number this will be the default setting –
2580).
3. Check the Keypad LED lights green with each button press. If the command is successful you will hear a single beep and the LED will turn red.
4. The ON indicator light should appear on the Control Panel. The panel will state aloud, “Switching on house, please exit now” and the exit delay beeps will begin.
5. Switch the system OFF by pressing the button. The ON indicator light on the Control Panel should go out and the display should revert to READY.
Usage
You can now use the Keypad buttons instead of the Control Panel to switch your BT Home Monitor VP1000 on and off. The Keypad is also equipped with panic button functions to allow people at home to send emergency, help and fire alerts.*
Keypad Buttons And Functions
FUNCTION PRESS
Switch House ON Then enter USER PIN
Turns your system on fully when you want to leave your house.
Switch Home ON Then enter USER PIN
Turns on selected sensors so you have protection but can still move around indoors. See Section 3 of the main User Guide for more information.
Switch OFF Then enter USER PIN
Turns your system off, except for 24-hour sensors which will continue to function.
Help Alarm Hold down for 2 seconds
Sends a help message to all your BT Home Monitor contacts.
Fire Alarm Hold down for 2 seconds
Sounds the internal siren and sends a fire message to all your BT Home Monitoring contacts.
Emergency Alarm + Hold down for 2 seconds
Sounds the internal siren and sends an emergency message to all your BT Home Monitoring contacts.
Status Report
Gives a system status report at the Control Panel.
Light
This function is not operational. Reserved for future devices.
BT Home Monitor Keypad VP
Installation and User Guide
BT Home Monitor Keypad VP – Edition 08 – 21.03.03
2
Indicator LED
Fire alarmHelp alarm
Emergency alarm (Press together)
Downloaded from www.ukpanels.com
OFF
ON
HOME
1
4
7
LIGHT
2
3
5
6
8
9
0
#
ON
OFF
ON
HOME
OFF
LIGHT
Keypad Indicator Light
COLOUR FUNCTION
Red Lights during transmission
Amber Lights during programming
Green Lights upon each press of a button
Red and Green Lights upon each press of a Help, alternately Fire or Emergency button
Set/Change Your User Codes
If you have not done so already, you should change your User Code from the default setting – 2580. If you have already selected new codes for your Control Panel you will need to program your Keypad with these same codes.
Please follow the instructions below:
PRESS DISPLAY
Green LED flashes slowly.
Enter the MASTER CODE – if you have not selected a personal PIN number, this will be the default setting – 2580.
Press 1 to set/change a new master User Code
Or
Press a button between 2 and 8 to set/change an additional User Code for other family members.
Enter the new 4-digit code you want. You will hear a confirmation melody and the Amber LED will flash slowly.
To confirm the change.
Using Multiple Keypads
The Keypad acts in the same way as the Control Panel, so only User 1 is able to have full control over the system, including the ability to change the BT Home Monitor VP1000 operational settings. Up to 7 other users can have limited access rights, such as the ability to turn the system on and off, by assigning individual user codes.
Deleting A Keypad
You may at some point decide you do not wish to use one or more of the Keypads.
To delete a Keypad from the Control Panel, follow these instructions.
PRESS DISPLAY
Until the display shows SYSTEM PROFILE.
Enter the MASTER CODE – if you have not selected a personal PIN number, this will be the default setting – 2580.
Until the display shows ADD/DEL KEYPAD.
Display shows KEYPAD NO:–
Enter the number of the Keypad you wish to delete, e.g. 1 or press NEXT to scroll through the list.
Display shows <OFF> TO DELETE.
Display shows KEYPAD NO: (number). Choose either:
To move to the next Keypad. Or:
Three times, then <OK> to exit and return to READY.
To test that the Keypad has successfully been deleted, press the button, followed by your User Code, to see whether the Control Panel responds. You may also wish to remove the battery.
Please remember to update your personal online account with this information so that your monitoring service can report information accurately.
#
4
1
#
BT Home Monitor Keypad VP
Installation and User Guide
BT Home Monitor Keypad VP – Edition 08 – 21.03.03
3
eg.
OFF
SHOW / OK
NEXT
NEXT
SHOW / OK
SHOW / OK
NEXT
HOME
Downloaded from www.ukpanels.com
ON
Maintenance
Low Battery Warning
The Keypad is powered by a 3V lithium battery which will last for up to 3 years. When the Keypad battery is running low, the Control Panel will display the message KEYPAD LOW BATTERY and the CHECK indicator light will be illuminated.
Replacing The Battery
1. Remove the wall-mounting bracket by pushing downward.
2. Slide down the battery cover and remove the old battery.
3. Insert the new battery (observing polarity + and –).
4. Replace the battery cover.
Cleaning
Clean with a soft cloth or damp sponge with a mild detergent. Wipe dry immediately. Do not submerge in water and do not use abrasives or solvents.
Support
For further assistance
If you need further information, please refer in the first instance to the main BT Home Monitor VP1000 User Guide.
Alternatively, BT advisors are on hand to assist – 24 hours a day, 7 days a week.
Telephone: 0870 240 1979. Call charges will apply.
Or email: bthomemonitoring-support@bt.com
Important Information
Product Information
Wireless systems are reliable and tested to high standards. However, due to their transmitting power and range, there are some limitations to be considered:
• Receivers may be blocked by radio signals occurring on or near operating frequencies, regardless of the code selected.
• A receiver can only respond to one transmitted signal at a time.
• Wireless equipment should be tested regularly to determine whether there are sources of interference and to protect against faults.
Specifications
Transmitted Powercode (Help, Fire and ID Type: Emergency) and CodeSecure
(Switching On and Off)
Frequency (MHz): 868.95
Battery: 3VDC Lithium Type CR123A
Current 10µA (during standby), 95mA Consumption: (during transmission including LED
and back light currents)
Battery Life 3 years (for typical use) Expectancy:
Operating 0ºC – 49ºC (32ºF – 120ºF) Temperature:
Dimensions: 127 x 70 x 24mm (5 x 2
3
4 x 31/32in)
Colour: Ivory
BT Home Monitor Keypad VP
Installation and User Guide
BT Home Monitor Keypad VP – Edition 08 – 21.03.03
4
Downloaded from www.ukpanels.com
BT Guarantee
Your BT Home Monitor Keypad VP is guaranteed for a period of 12 months from the date of purchase. Subject to the terms listed below, the guarantee will provide for the repair of, or at BT’s or its agent’s discretion the option to replace the BT Home Monitor Keypad VP, or any component thereof, which is identified as faulty or below standard, as a result of inferior workmanship of materials. Products over 28 days old from the date of purchase may be replaced with a refurbished product.
The conditions of this guarantee are:
• The guarantee shall only apply to defects that occur within the 12 month guarantee period.
• Proof of purchase is required.
• The equipment is returned to BT or its agent as instructed.
• This guarantee does not cover any faults or defects caused by accidents, misuse, fair wear and tear, neglect, tampering with the equipment, or any attempt at adjustment or repair other than through approved agents.
• This guarantee does not affect your statutory rights.
Within the 12 month guarantee period:
If you experience difficulty using the product, prior to returning it, please contact BT Home Monitor Support for assistance on 0870 240 1979 – 24 hours, 7 days a week (call charges will apply).
In the unlikely event of a defect occurring, please follow the helpdesk’s instructions for replacement or repair.
Outside of the 12 month guarantee period:
If your product needs repair after the guarantee period has ended, we recommend that you call the helpdesk for information.
Instructions for returning the product:
If the helpdesk is unable to remedy your problem they may ask you to return the product to the original point of purchase. Where possible, pack the product in its original packaging. Please remember to include all parts. (Please note that we cannot take responsibility for goods damaged in transit.) Please obtain and keep proof of posting.
Terms and Conditions
For full Terms and Conditions for BT Home Monitoring, please visit www.bt.com/homemonitoring
Declaration of Conformity with European Community Directive 1999/5/EC.
This product is intended for use within the UK for connection to the public telephone network and compatible switchboards. This equipment complies with the essential requirements for the Radio Equipment and Telecommunications Terminal Equipment Directive 1999/5/EC.
The Declaration of Conformity for the BT Home Monitor VP1000 is published on the website:
http://www.visonic.com/bthomemonitor
BT Home Monitor Keypad VP
Installation and User Guide
BT Home Monitor Keypad VP – Edition 08 – 21.03.03
5
* You must have an active subscription to the
BT Home Monitoring System to receive alerts.
Downloaded from www.ukpanels.com
BT Home Monitor Keypad VP
Installation and User Guide
BT Home Monitor Keypad VP – Edition 08 – 21.03.03
Offices worldwide
The telecommunications services described in this publication are subject to availability and may be modified from time to time. Services and equipment are provided subject to British Telecommunications plc’s respective standard conditions of contract. Nothing in this publication forms any part of any contract.
© British Telecommunications plc 2003 Registered office: 81 Newgate Street, London EC1A 7AJ Registered in England No: 1800000
BT Home Monitor Keypad VP (03/03) 7
Printed in Israel
Downloaded from www.ukpanels.com
Loading...