The Bryant electronic thermostat product line consists of programmable and non-programmable air conditioner, heat pump,
and 2-speed models; a programmable dual fuel model; and a
programmable/non-programmab le Thermidistat
also offers builder’s and standard programmable thermostats in
both air conditioner and heat pump models. These units feature
non-mercury based electronic controls built into a subtle, slim
plastic enclosure. They require no battery back-up.
FEATURES/BENEFITS
BUILDER’S THERMOST A TS
COMPLETE OFFERING —Non-programmable air conditioner
and heat pump models available.
EASY TO USE —Rubber push buttons provide easy changes to
heating/cooling mode operation, fan operation, and desired temperature setting.
MANUAL CHANGEOVER —Allows manual switches in system
operation when both heating and cooling are needed on the
same day.
TM
Control. Bryant
* Models (AC, HP)
NON-PROGRAMMABLE THERMOST A T
* Models (AC, HP, 2S)
PROGRAMMABLE THERMOSTAT, DUAL FUEL,
AND THERMIDIST A T
TM
CONTROL
STANDARD PROGRAMMABLE THERMOSTATS
Bryant Standard Programmable Thermostats posess the same
features as the Builder’ s Thermostats plus:
COMFORT AND ENERGY SAVINGS —5-2 Day Programming
with four temperature changes per day means comfort for the
family.
EASY TO READ —Large LCD with clock.
NON-PROGRAMMABLE THERMOSTATS
CLEAN DESIGN —Features soft, responsive buttons and an
Bryant programmable thermostats possess the same features as
non-programmable thermostats plus:
Form No. PDS TSTAT.0.4
Page 2
COMFORT AND ENERGY SAVINGS —
Seven day programming, with 4 temperature changes provided per day, means
comfort when the family is at home and
savings through reduced energy usage
when the family is away or asleep.
EASY TO USE —Simple instructions are
located inside the thermostat’s door .
DUPLICATE PROGRAMMING —Copy
the comfort schedule from one day to the
next using the copy previous day function.
OVERRIDE CAPABILITY —Hold function
allows the regular schedule to be bypassed with a temporary setting.
BATTERY-FREE —Non-volatile RAM chip
requires no battery backup. Program is retained in memory so reprogramming is not
required after power loss.
SMART RECOVERY —Provides consis-
tent heating right on time as it gradually
adjusts indoor temperatures before a
scheduled change.
TIMEGUARD —Equipment protection.
DUAL FUEL MODEL
The dual fuel thermostat can be used to
control a gas furnace and a heat pump.
This thermostat eliminates the need for
an interface control kit. The outdoor temperature sensor is included.
THERMIDISTAT
TM
CONTROL
Bryant’s Thermidistat Control can be used
to control any equipment application except zoning. It possesses all the features
and benefits of Bryant’s non-programmable and programmable thermostats plus:
ENHANCED COMFORT —Allows the
homeowner to accurately maintain the
desired temperature and humidity settings in the home. By combining the
functions of a programmable/nonprogrammable thermostat and a humidistat, the Thermidistat Control provides
temperature control, humidity control,
and dehumidification.
HUMIDITY CONTROL —The Thermidi-
stat Control accurately controls humidity.
It controls humidification during heating
and dehumidification during cooling.
AUTOMATIC HUMIDITY ADJUSTMENT —When used with the outdoor
temperature sensor, the Thermidistat
Control automatically adjusts the humidify setting, reducing excess condensation from forming on the windows.
VACATION MODE —With a single touch
of a button, vacation mode adjusts all
comfort levels for optimum efficiency
while the home is unoccupied—or restores the settings to normal upon return.
SMART RECOVERY —Provides consis-
tent heating and cooling right on time as it
gradually adjusts indoor temperatures before a scheduled change.
EQUIPMENT ON INDICATOR —When
the cooling system is operating, the word
COOL preceded by a small triangle is displayed below the cooling set point. When
the heating equipment is operating, the
word HEAT preceded by a small triangle
is displayed below the heating set point. If
the equipment turn on is being delayed,
the triangle and the word will flash.
NON-PROGRAMMABLE OPTION —Offers
the same popular humidity control benefits to consumers who do not need the
added benefits of programming. Nine
functional buttons, along with the UP and
DOWN buttons, mak e it easy to enter the
temperature and humidity set points. The
LCD is the largest display on the market
for a non-programmable thermostat.
T STAT
THERMOSTAT
BB
BB – BRYANT BRAND
MODEL NUMBER NOMENCLATURE
ELECTRONIC THERMOST A TS
ACN
AC – AIR CONDITIONING
HP – HEAT PUMP
2S – TWO SPEED/TWO STAGE
DF – DUAL FUEL
RH – RELATIVE HUMIDITY (THERMIDISTAT CONTROL)
B – BUILDER'S MODEL
S – STANDARD PROGRAMMABLE
P – PROGRAMMABLE
N – NON-PROGRAMMABLE
01
QUANTITY
–B
SERIES
A99046
As an ENERGY STAR® Partner,
Bryant Heating & Cooling Systems has
determined that the programmable
thermostats and programmable
Thermidistat Control meet the
ENERGY STAR® guidelines for
energy efficiency .
—2—
Page 3
DIMENSIONS
2 3⁄4″
Builder's Model Thermostat
31⁄2"
4 1⁄4″
3
⁄4″
3
⁄4″
3 1⁄2″
4 3⁄8″
51⁄2"
Standard Programmable Thermostat
1 3⁄8″
5 13⁄16″
Non-Programmable Thermostat
1 3⁄8″
7 3⁄8″
Programmable Thermostat and Thermidistat Control
A99224
—3—
Page 4
PRODUCT DATA INFORMATION
PHYSICAL CHARACTERISTICS
Builder’s/Standard Programmable Models:
Dimensions: See drawing
Appearance: Plastic, designer white, textured, white rubber push buttons
Non-Programmable/Programmable Models:
Dimensions: See drawing
Appearance: Plastic, eggshell color, textured
ELECTRICAL CHARACTERISTICS
Builder’s/Standard Programmable Models:
Input Volts/Amps: 24vac, 1 VA
Non-Programmable/Programmable Models:
Furnace model numbers 355MAV, 373LAD, 383KAD, 394HAD, 396HAD, 361A, 362A, 363A, 367A, 369A, and 349MAV; and the Thermostat Conversion Kit are not compatible with these thermostats.
† Do not use in zoning applications.
PART NO.DESCRIPTION
TST ATBBSAC01*Thermostat, Air Conditioner, 5-2 Day Programmab le, 1-Stage Heat/1-Stage Cool, Man ual Changeov er , °F/°C
TSTATBBSHP01†Thermostat, Heat Pump, 5-2 Day Programmable, 2-Stage Heat/1-Stage Cool, Manual Changeover, °F/°C
Thermostat Conversion Kit is not compatible with these thermostats.
TSTATBBNAC01-BThermostat, Auto Changeover, Non-Programmable, °F/°C, 1-Stage Heat/1-Stage Cool
TSTATBBNHP01-BThermostat, Auto Changeover, Non-Programmable, °F/°C, 2-Stage Heat/1-Stage Cool
TSTATBBN2S01-BThermostat, Auto Changeover, Non-Programmable, °F/°C, 2-Stage Heat/2-Stage Cool
in AC Mode, 3-Stage Heat/2-Stage Cool in HP Mode
PROGRAMMABLE ELECTRONIC THERMOSTATS
PART NO.DESCRIPTION
TSTATBBPAC01-BThermostat, Auto Changeover, 7-Day Programmable, °F/°C, 1-Stage Heat/1-Stage Cool
TSTATBBPHP01-BThermostat, Auto Changeover, 7-Day Programmable, °F/°C, 2-Stage Heat/1-Stage Cool
TSTATBBP2S01-BThermostat, Auto Changeover, 7-Day Programmable, °F/°C, 2-Stage Heat/2-Stage Cool
TSTATBBPDF01-B*Dual Fuel Thermostat, Includes Outdoor Air Temperature Sensor
TSTATBBPRH01-B*Thermidistat Control — Non-Programmable/Programmable Thermostat with Humidity Control
* Do not use in zoning applications.
in AC Mode, 3-Stage Heat/2-Stage Cool in HP Mode
(For use in Dual Fuel, AC, HP, and 2S applications. Includes Outdoor Air Temperature Sensor.)
THERMOSTAT ACCESSORIES
PART NO.DESCRIPTION
TSTATXXSEN01-B*Outdoor Air Temperature Sensor
TSTATXXNBP01†Backplate for Non-Programmable Thermostat
TSTATXXPBP01†Backplate for Programmable Thermostat and Thermidistat Control
TSTATXXBBP01†Backplate for Builder’s Thermostat
TSTATXXSBP01†Backplate for Standard Programmable Thermostat
TSTATXXCNV10‡Thermostat Conversion Kit (4 to 5 wire) — 10 pack
* Outdoor air temperature sensor is an accessory for all Bryant electronic thermostats, except the non-programmable air conditioner version and builder’s
and standard programmable thermostats. It allows the temperature at a remote location (outdoors) to be displayed on the thermostat.
The outdoor air temperature sensor
The outdoor air temperature sensor is included with the Thermidistat Control and dual fuel thermostat.
† This plate is designed to cover surrounding wall area located behind thermostat.
‡ Thermostat conversion kit is a 24-vac accessory that can turn a 4-wire thermostat application into a 5-wire application. This kit can also be used to replace
a broken thermostat wire, or add an extra wire when needed. Do not use this kit with the AC model of the Builder’s or Standard Programmable thermostat.
must be
used with the dual fuel thermostat.
—5—
Page 6
THERMOSTAT AND THERMIDISTAT CONTROL APPLICATION
NON-PROGRAMMABLE THERMOST A T USAGE
OUTDOOR UNIT
Air ConditionerHeat Pump
INDOOR UNIT
1-Stage FurnaceModel AC or HP*Model 2S†Model 2S‡
2-Stage FurnaceModel AC or HP*Model 2S†Model 2S‡
Typical Fan CoilModel AC or HP*Model 2SModel HPModel 2S
FK, FV Series Fan CoilModel AC or HP*Model 2SModel HPModel 2S
* Model HP thermostat must be field converted to air conditioner operation.
† Must use Programmable Dual Fuel Thermostat or Thermidistat Control in this application.
‡ Dual Fuel operation controlled by heat pump when using Model 2S Thermostat.
The TSTATBBNAC01-B Thermostat provides single-stage, non-programmable heat/cool temperature control for 24-vac heatingcooling systems with auto changeover. Temperature display can be selected to read °F or °C.
The TSTATBBNHP01-B Thermostat provides versatile 2-stage heating and single-stage cooling, non-programmable temperature
control for 24-vac heating-cooling systems with auto changeover. Temperature display can be selected to read °F or °C. Thermostat
comes factory set to operate as a heat pump model with second-stage controlling auxiliary electric heat. This model can easily be
converted from heat pump operation to air conditioning operation requiring 2 stages of gas or electric heat.
The TSTATBBN2S01-B Thermostat provides versatile multiple stage, non-programmable heat/cool temperature control for 24-vac
heating-cooling systems with auto changeover. Temperature display can be selected to read °F or °C. Thermostat is designed for
2-speed compressor bearing units. Ther mostat comes factory set to operate as a heat pump model with 2-stage cooling and
3 stages of heat (third-stage controlling auxiliary electric heat). This model can easily be converted from heat pump operation
to air conditioning operation requiring 2 stages of cooling and 2 stages of heating.
1 Speed2 Speed1 Speed2 Speed
Non-Programmable Models
PROGRAMMABLE THERMOST A T USAGE
OUTDOOR UNIT
Air ConditionerHeat Pump
INDOOR UNIT
1-Stage FurnaceModel AC or HP*Model 2SModel DFModel DF or 2S‡
2-Stage FurnaceModel AC or HP*Model 2SModel DFModel DF or 2S‡
Typical Fan CoilModel AC or HP*Model 2SModel HPModel 2S
FK, FV Series Fan CoilModel AC or HP*Model 2SModel HP or 2S†Model 2S
* Model HP thermostat must be field converted to AC operation.
† For use with special 3-stage electric heat setup.
‡ Dual Fuel operation controlled by heat pump when using Model 2S thermostat.
1 Speed2 Speed1 Speed2 Speed
Programmable Models
The TSTATBBPAC01-B Thermostat provides single-stage, 7-day programmable heat/cool temperature control for 24-vac heatingcooling systems with auto changeover. Temperature display can be selected to read °F or °C.
The TSTATBBPHP01-B Thermostat provides versatile 2-stage heating and single-stage cooling, 7-day programmable temperature
control for 24-vac heating-cooling systems with auto changeover. Temperature display can be selected to read °F or °C. Thermostat
comes factory set to operate as a heat pump model with second-stage controlling auxiliary electric heat. This model can easily be
converted from heat pump operation to air conditioning operation requiring 2 stages of gas or electric heat.
The TSTATBBP2S01-B Thermostat provides versatile multiple stage, 7-day programmable heat/cool temperature control for 24-vac
heating-cooling systems with auto changeover. Temperature display can be selected to read °F or °C. Thermostat is designed primarily for 2-speed compressor bearing units. Ther mostat comes factory set to operate as a heat pump model with 2-stage
cooling and 3-stages of heat (third-stage controlling auxiliary electric heat). This model can also perform intelligent heatstaging with FK & FV fan coils (special heaters and setup required) using a single-speed heat pump with 3-stages auxiliary
electric heat. In addition, this model can easily be converted from heat pump operation to air conditioning operation requiring 2
stages of cooling and 2 stages of heating (e.g. gas or electric heat).
—6—
Page 7
Programmable Dual Fuel Model
The TSTATBBPDF01-B Thermostat provides single-stage or multiple-stage dual fuel operation, 7-day programmable heat/cool temperature control for 24-vac systems with auto changeover. Temperature display can be selected to read °F or °C. The Dual Fuel
Thermostat is designed with separate lockout temperatures for the furnace and the heat pump. The furnace is prevented from operating above its lock out temperature and the heat pump is prevented from operating below its loc k out temper ature . Thermostat comes
factory set to operate single-speed equipment, but is easily configured to match multiple stage equipment combinations. This model
requires use of the Outdoor Air Temperature Sensor accessory, which is included with the Dual Fuel Thermostat. Using the dual fuel
thermostat eliminates the need for an interface control.
THERMIDISTAT CONTROL USAGE
OUTDOOR UNIT
Air ConditionerHeat Pump
INDOOR UNIT
1-Stage Furnace
2-Stage Furnace
Typical Fan Coil
FK, FV Series Fan Coil
* The Thermidistat Control may be used in all applications but must be field configured for specific application.
1 Speed2 Speed1 Speed2 Speed
Model RH*
Thermidistat Control
The TSTATBBPRH01-B Thermidistat Control provides single-stage or multiple-stage equipment operation, 7-day programmable
heat/cool temperature control for 24-vac systems with auto changeover. It controls both humidification and dehumidification and can
be used to control heat pumps, air conditioners, or dual fuel applications. Temperature display can be selected to read °F or °C. The
Thermidistat Control is designed primarily as an extension of the programmable thermostat line to provide humidify and dehumidify
outputs in controlling humidity. It can also be field configured to be non-programmable. Humidify outputs connect directly to 24-v
humidifiers. Dehumidify outputs connect directly to variable-speed furnaces or fan coils that have dehumidification capabilities. To
achieve full benefits, this model requires use of the Outdoor Air Temperature Sensor accessory, which is included with the Thermidistat Control. The Thermidistat Control will deliver Perfect Heat Plus mode when matched with variable-speed equipment.
—7—
Page 8
OPERATIONAL INFORMATION
FIVE-MINUTE COMPRESSOR TIMEGUARD
This timer prevents the compressor from starting unless it has been off for at least 5 minutes. It can be defeated for 1 cycle by simultaneously pressing the F AN mode button and INCREASE TEMPERATURE (UP) button.
FIFTEEN-MINUTE CYCLE TIMER
This timer prevents the start of a heating or cooling cycle until at least 15 minutes after the last start of the same cycle. Its function is to
assure that equipment is not cycled more than 4 times per hr. This timer is defeated for 1 cycle when the desired temper ature is man ually
changed. It can also be defeated for 1 cycle by simultaneously pressing the FAN button and the INCREASE TEMPERATURE button.
FIFTEEN-MINUTE STAGING TIMER
In multistage heating or cooling, this timer prevents any higher stage from turning on until preceding stage has been on for 15 minutes.
This timer is defeated if temperature error is greater than 5°F (usually due to a large change in desired temperature).
MINIMUM ON TIME
In normal operation, when a stage turns on, it will not turn off for a minimum of 3 minutes (2 minutes on Builder’s model).
HEAT/COOL SET POINTS (DESIRED TEMPERATURE)
A minimum difference of 2°F is enforced between heating and cooling desired temperatures. This is done by allowing one setting to
“push” the other , to maintain this difference. (Thermidistat Control is adjustable.) Builder’ s thermostats are controlled by a single set point.
EQUIPMENT ON INDICATORS (NON-PROGRAMMABLE MODELS)
When cooling equipment is ON, a COOL ON icon is displayed above the room temperature display. When heating equipment is ON, a
HEAT ON icon is displayed above the room temperature displa y.
EQUIPMENT ON INDICATORS (THERMIDISTAT CONTROL)
When cooling equipment is ON, a COOL icon preceded by a small triangle is displayed below the cool set point. While cooling equipment turn on is delayed by a staging or cycle timer, the triangle and the word COOL will flash. The same is true for the HEAT icon and
its preceding triangle located under the heat set point. The 2 triangles are also used to indicate the state of the humidify and dehumidify
outputs. See next section.
HUMIDIFY/DEHUMIDIFY OUTPUT ON INDICATORS (THERMIDISTAT CONTROL)
Within humidity select screen (selected by Humidity button and indicated by “hu” or “dhu” on clock display), the triangle under humidity
set point will be on while humidify output is on. The tr iangle under dehumidify set point will be on while dehumidify output is active
(turned off, because this output is reverse logic).
AUTO CHANGEOVER
When auto changeover mode is selected, a change from heat to cool (or vice versa) will not occur until an opposite mode demand has
existed for 20 minutes. If set point is changed, the 20 minute requirement is deleted. Auto changeover mode can be disabled. Builder’s
and Standard Programmable thermostats are manual changeover.
EMERGENCY HEAT MODE
When thermostat is controlling as a heat pump and emergency heat is selected, all Y signals are loc k ed out, and W becomes energized
upon a call for heat.
SMART RECOVERY (PROGRAMMABLE MODELS)
With Smart Recovery selected, transition out of setback begins a fixed time period before selected recovery time and gradually adjusts
room temperature so that the desired temperature will be achiev ed at selected recovery time.
ROOM TEMPERATURE OFFSET (ALL MODELS)
Room temperature may be deliberately offset by up to 5°F in either direction.
MAXIMUM ON/OFF DEADBAND
Maximum sensed temperature difference between ON and OFF is 0.8°F for Builder’s thermostats and 0.6°F for all other models.