The Bryant electronic thermostat product line consists of programmable and non-programmable air conditioner, heat pump,
and 2-speed models; a programmable dual fuel model; and a
programmable/non-programmab le Thermidistat
also offers builder’s thermostats in both air conditioner and heat
pump models. These units feature non-mercury based electronic
controls built into a subtle, slim plastic enclosure. They require no
battery back-up and the programmable/non-programmable models are not power stealing.
COMPLETE OFFERING —Non-programmable air conditioner
and heat pump models available.
EASY TO USE —Rubber push buttons provide easy changes to
heating/cooling mode operation, fan operation, and desired temperature setting.
MANUAL CHANGEOVER —Allows manual switches in system
operation when both heating and cooling are needed on the
same day.
FEATURES/BENEFITS
BUILDER’S THERMOST A TS
MODEL
TSTAT
TM
Control. Bryant
* Standard Model (AC, HP, 2S)
PROGRAMMABLE THERMOSTAT, DUAL FUEL,
AND THERMIDIST A T
TM
CONTROL
®
NON-PROGRAMMABLE THERMOSTATS
CLEAN DESIGN —Features soft, responsive buttons and an
shows current room temperature at all times, and desired temperature prompts upon demand.
AUTO CHANGEOVER —Switches system operation automati-
cally when both heating and cooling are needed on the same
day. It can be disabled if not necessary in certain areas of the
country.
OUTDOOR TEMPERATURE DISPLAY —Allows a check of the
temperature outside before leaving home. (Optional on heat
pump and 2-speed models.)
CLEAN FILTER INDICATOR —Tells when it is time to clean the
system’s filter.
BATTERY FREE —Non-volatile RAM chip requires no battery
backup.
EQUIPMENT ON INDICATOR —On all non-programmable mod-
els, HEAT ON or COOL ON indicator is displayed when the
heating or cooling equipment is operating.
PERFECT COMPLEMENT —Completes your Bryant total com-
fort system needs.
LIMITED WARRANTY —Standard 1-year warranty available on
all parts.
ROOM TEMPERATURE OFFSET —Room temperature may be
deliberately offset by up to 5°F in either direction to accommodate end user’s needs.
* Standard Model (AC, HP, 2S)
* Dual Fuel Model (DF)
* Thermidistat
TM
Control Model (RH)
PROGRAMMABLE THERMOSTATS
Bryant programmable thermostats possess the same features as
non-programmable thermostats plus:
COMFORT AND ENERGY SAVINGS —Seven day program-
ming, with 4 temperature changes provided per day, means
comfort when the family is at home and savings through reduced
energy usage when the family is away or asleep.
Form No. PDS TSTAT.0.3
EASY TO USE —Simple instructions are
located inside the thermostat’s door .
DUPLICATE PROGRAMMING —Copy
the comfort schedule from one day to the
next using the copy previous day
function.
OVERRIDE CAPABILITY —Hold function
allows the regular schedule to be bypassed with a temporary setting.
BATTERY-FREE —Non-volatile RAM chip
requires no battery backup. Program is retained in memory so reprogramming is not
required after power loss.
SMART RECOVERY —Provides consis-
tent heating right on time as it gradually
adjusts indoor temperatures before a
scheduled change.
TIMEGUARD —Equipment protection.
DUAL FUEL MODEL
The dual fuel thermostat can be used to
control a gas furnace and a heat pump.
This thermostat eliminates the need for
an interface control kit. The outdoor temperature sensor is included.
THERMIDISTAT
Bryant’s Thermidistat Control can be used
to control any equipment application except zoning. It possesses all the features
and benefits of Bryant’s non-programmable and programmable thermostats plus:
ENHANCED COMFORT —Allows the
homeowner to accurately maintain the
desired temperature and humidity settings in the home. By combining the
functions of a programmable thermostat
and a humidistat, the Thermidistat Control
provides temperature control, humidity
control, and dehumidification.
HUMIDITY CONTROL —The Thermidi-
stat Control accurately controls humidity.
It humidifies during heating and dehumidifies during cooling.
AUTOMATIC HUMIDITY ADJUSTMENT —When used with the outdoor
temperature sensor, the Thermidistat
Control automatically adjusts the humidity setting, reducing excess condensation from forming on the windows.
VACATION MODE —With a single touch
of a button, vacation mode adjusts all
TM
CONTROL
comfort levels for optimum efficiency
while the home is unoccupied—or restores the settings to normal upon return.
SMART RECOVERY —Provides consis-
tent heating and cooling right on time as it
gradually adjusts indoor temperatures before a scheduled change.
EQUIPMENT ON INDICATOR —When
the cooling system is operating, the word
COOL preceded by a small triangle is displayed below the cooling set point. When
the heating equipment is operating, the
word HEAT preceded by a small triangle
is displayed below the heating set point. If
the equipment turn on is being delayed,
the triangle and the word will flash.
NON-PROGRAMMABLE OPTION —Offers
the same popular humidity control benefits to consumers who do not need the
added benefits of programming. Nine
functional buttons, along with the UP and
DOWN buttons, mak e it easy to enter the
temperature and humidity set points. The
LCD is the largest display on the market
for a non-programmable thermostat.
T STAT
THERMOSTAT
BB
BB – BRYANT BRAND
MODEL NUMBER NOMENCLATURE
ELECTRONIC THERMOST A TS
ACN
AC – AIR CONDITIONING
HP – HEAT PUMP
2S – TWO SPEED/TWO STAGE
DF – DUAL FUEL
RH – RELATIVE HUMIDITY (THERMIDISTAT CONTROL)
B – BUILDER'S MODEL
P – PROGRAMMABLE
N – NON-PROGRAMMABLE
01
QUANTITY
–B
SERIES
A99046
As an ENERGY STAR
Bryant Heating & Cooling Systems has
determined that the programmable
thermostats and programmable
Thermidistat Control meet the
ENERGY STAR guidelines for energy
efficiency .
SM
Partner,
—2—
DIMENSIONS
3
2
⁄4″
1
4
⁄4″
Builder's Model Thermostat
3
⁄4″
3
⁄8″
1
3 1⁄2″
4 3⁄8″
®
5 13⁄16″
Non-Programmable Thermostat
1 3⁄8″
7 3⁄8″
Programmable Thermostat and Thermidistat Control
—3—
A99045
PRODUCT DATA INFORMATION
PHYSICAL CHARACTERISTICS
Builder’s Models:
Dimensions: See drawing
Appearance: Plastic, designer white, textured, white rubber push buttons
Non-Programmable/Programmable Models:
Dimensions: See drawing
Appearance: Plastic, eggshell color, textured
ELECTRICAL CHARACTERISTICS
Builder’s Models:
Input Volts/Amps: 24vac, 1 VA
Non-Programmable/Programmable Models:
Input Volts/Amps: 24vac, 5 VA
ENVIRONMENTAL REQUIREMENTS:
Operating Temperature/Relative Humidity: 32°F (0°C) to 104°F (40°C)/95% rh non-condensing
Storage Temperature/Relative Humidity: –40°F (–40°C) to 134°F (56°C)/95% rh non-condensing
PROGRAM SPECIFICATIONS:
Builder’s Models:
Temperature set point range: 50°F (10°C) to 90°F (32°C)
Manual changeover
Non-volatile memory
Fahrenheit or Celsius selectable
Power-stealing option on AC model only
Selectable fan ON or OFF with auxiliary heating (HP model)
Five-minute compressor timeguard
Four cycles per hour maximum
Auxiliary heat LED on heat pump models
Non-Programmable Models:
Temperature setpoint range: 40°F (4°C) to 90°F (32°C)
Separate heat and cool setpoints
Auto changeover—can be disabled
Clean filter reminder: installer adjustable
Permanent memory
Equipment On indicator
Programmable Models:
Temperature setpoint range: 40°F (4°C) to 90°F (32°C)
Separate heat and cool setpoints
Auto changeover—can be disabled
Clean filter reminder: installer adjustable
Permanent memory
Programming days: 7 day
Programming periods: 4—Wake, Day, Eve, Sleep
Hold function
Copy previous day function
Humidity display and control (Thermidistat Control only)
Equipment On indicator (Thermidistat Control only)
WIRING REQUIREMENTS:
Power: 24vac nominal, 18- to 30-vac, 50/60 Hz
Wiring: Standard thermostat wire 18 to 22 gage.
* Variable-speed furnaces (355MAV) are not compatible with power stealing thermostat applications (i.e. no common wire connection). In order to
use this thermostat with variable-speed furnaces, a common wire MUST be applied.
** Do not use in zoning applications.
NON-PROGRAMMABLE ELECTRONIC THERMOSTATS
PART NO.DESCRIPTION
TSTATBBNAC01-BThermostat, Auto Changeover, Non-Programmable, °F/°C, 1-Stage Heat/1-Stage Cool
TSTATBBNHP01-BThermostat, Auto Changeover, Non-Programmable, °F/°C, 2-Stage Heat/1-Stage Cool
TSTATBBN2S01-BThermostat, Auto Changeover, Non-Programmable, °F/°C, 2-Stage Heat/2-Stage Cool
in AC Mode, 3-Stage Heat/2-Stage Cool in HP Mode
PROGRAMMABLE ELECTRONIC THERMOSTATS
PART NO.DESCRIPTION
TSTATBBPAC01-BThermostat, Auto Changeover, 7-Day Programmable, °F/°C, 1-Stage Heat/1-Stage Cool
TSTATBBPHP01-BThermostat, Auto Changeover, 7-Day Programmable, °F/°C, 2-Stage Heat/1-Stage Cool
TSTATBBP2S01-BThermostat, Auto Changeover, 7-Day Programmable, °F/°C, 2-Stage Heat/2-Stage Cool
TSTATBBPDF01-B*Dual Fuel Thermostat, Includes Outdoor Air Temperature Sensor
TSTATBBPRH01-B*Thermidistat Control — Non-Programmable/Programmable Thermostat with Humidity Control
* Do not use in zoning applications.
in AC Mode, 3-Stage Heat/2-Stage Cool in HP Mode
(For use in Dual Fuel, AC, HP, and 2S applications. Includes Outdoor Air Temperature Sensor.)
THERMOSTAT ACCESSORIES
PART NO.DESCRIPTION
TSTATXXSEN01-B*Outdoor Air Temperature Sensor
TSTATXXNBP01†Backplate for Non-Programmable Thermostat
TSTATXXPBP01†Backplate for Programmable Thermostat and Thermidistat Control
TSTATXXBBP01†Backplate for Builder’s Model Thermostat
TSTATXXCNV10‡Thermostat Conversion Kit (4 to 5 wire) — 10 pack
* Outdoor air temperature sensor is an accessory for all Bryant electronic thermostats, except the non-programmable air conditioner version and builder’s
model thermostats. It allows the temperature at a remote location (outdoors) to be displayed on the thermostat.
The outdoor air temperature sensor
The outdoor air temperature sensor is included with the Thermidistat Control and dual fuel thermostat.
† This plate is designed to cover surrounding wall area located behind thermostat.
‡ Thermostat conv ersion kit is a 24-v ac accessory that can turn a 4-wire thermostat application into a 5-wire application. This kit can also be used to replace
a broken thermostat wire, or add an extra wire when needed.
must be
used with the dual fuel thermostat.
—5—
THERMOSTAT AND THERMIDISTAT CONTROL APPLICATION
NON-PROGRAMMABLE THERMOST A T USAGE
OUTDOOR UNIT
Air ConditionerHeat Pump
INDOOR UNIT
1-Stage FurnaceModel AC or HP*Model 2S†Model 2S‡
2-Stage FurnaceModel AC or HP*Model 2S†Model 2S‡
Typical Fan CoilModel AC or HP*Model 2SModel HPModel 2S
FK, FV Series Fan CoilModel AC or HP*Model 2SModel HPModel 2S
* Model HP thermostat must be field converted to air conditioner operation.
† Must use Programmable Dual Fuel Thermostat or Thermidistat Control in this application.
‡ Dual Fuel operation controlled by heat pump when using Model 2S Thermostat.
The TSTATBBNAC01-B Thermostat provides single-stage, non-programmable heat/cool temperature control for 24-vac heatingcooling systems with auto changeover. Temperature display can be selected to read °F or °C.
The TSTATBBNHP01-B Thermostat provides versatile 2-stage heating and single-stage cooling, non-programmable temperature
control for 24-vac heating-cooling systems with auto changeover. Temperature display can be selected to read °F or °C. Thermostat
comes factory set to operate as a heat pump model with second-stage controlling auxiliary electric heat. This model can easily be
converted from heat pump operation to air conditioning operation requiring 2 stages of gas or electric heat.
The TSTATBBN2S01-B Thermostat provides versatile multiple stage, non-programmable heat/cool temperature control for 24-vac
heating-cooling systems with auto changeover. Temperature display can be selected to read °F or °C. Thermostat is designed for
2-speed compressor bearing units. Ther mostat comes factory set to operate as a heat pump model with 2-stage cooling and
3 stages of heat (third-stage controlling auxiliary electric heat). This model can easily be converted from heat pump operation
to air conditioning operation requiring 2 stages of cooling and 2 stages of heating.
1 Speed2 Speed1 Speed2 Speed
Non-Programmable Models
PROGRAMMABLE THERMOST A T USAGE
OUTDOOR UNIT
Air ConditionerHeat Pump
INDOOR UNIT
1-Stage FurnaceModel AC or HP*Model 2SModel DFModel DF or 2S‡
2-Stage FurnaceModel AC or HP*Model 2SModel DFModel DF or 2S‡
Typical Fan CoilModel AC or HP*Model 2SModel HPModel 2S
FK, FV Series Fan CoilModel AC or HP*Model 2SModel HP or 2S†Model 2S
* Model HP thermostat must be field converted to AC operation.
† For use with special 3-stage electric heat setup.
‡ Dual Fuel operation controlled by heat pump when using Model 2S thermostat.
1 Speed2 Speed1 Speed2 Speed
Programmable Models
The TSTATBBPAC01-B Thermostat provides single-stage, 7-day programmable heat/cool temperature control for 24-vac heatingcooling systems with auto changeover. Temperature display can be selected to read °F or °C.
The TSTATBBPHP01-B Thermostat provides versatile 2-stage heating and single-stage cooling, 7-day programmable temperature
control for 24-vac heating-cooling systems with auto changeover. Temperature display can be selected to read °F or °C. Thermostat
comes factory set to operate as a heat pump model with second-stage controlling auxiliary electric heat. This model can easily be
converted from heat pump operation to air conditioning operation requiring 2 stages of gas or electric heat.
The TSTATBBP2S01-B Thermostat provides versatile multiple stage, 7-day programmable heat/cool temperature control for 24-vac
heating-cooling systems with auto changeover. Temperature display can be selected to read °F or °C. Thermostat is designed primarily for 2-speed compressor bearing units. Ther mostat comes factory set to operate as a heat pump model with 2-stage
cooling and 3-stages of heat (third-stage controlling auxiliary electric heat). This model can also perform Intelligent-Heat
staging with FK and FV fan coils (special heaters and setup required) using a single-speed heat pump with 3-stages auxiliary
electric heat. In addition, this model can easily be converted from heat pump operation to air conditioning operation requiring 2
stages of cooling and 2 stages of heating (e.g. gas or electric heat).
—6—
Programmable Dual Fuel Model
The TSTATBBPDF01-B Thermostat provides single-stage or multiple-stage dual fuel operation, 7-day programmable heat/cool temperature control for 24-vac systems with auto changeover. Temperature display can be selected to read °F or °C. The Dual Fuel
Thermostat is designed with separate lockout temperatures for the furnace and the heat pump. The furnace is prevented from operating above its lock out temperature and the heat pump is prevented from operating below its loc k out temper ature . Thermostat comes
factory set to operate single-speed equipment, but is easily configured to match multiple stage equipment combinations. This model
requires use of the Outdoor Air Temperature Sensor accessory, which is included with the Dual Fuel Thermostat. Using the dual fuel
thermostat eliminates the need for an interface control.
THERMIDISTAT CONTROL USAGE
OUTDOOR UNIT
Air ConditionerHeat Pump
INDOOR UNIT
1-Stage Furnace
2-Stage Furnace
Typical Fan Coil
FK, FV Series Fan Coil
* The Thermidistat Control may be used in all applications but must be field configured for specific application.
1 Speed2 Speed1 Speed2 Speed
Model RH*
Thermidistat Control
The TSTATBBPRH01-B Thermidistat Control provides single-stage or multiple-stage equipment operation, 7-day programmable
heat/cool temperature control for 24-vac systems with auto changeover. It controls both humidification and dehumidification and can
be used to control heat pumps, air conditioners, or dual fuel applications. Temperature display can be selected to read °F or °C. The
Thermidistat Control is designed primarily as an extension of the programmable thermostat line to provide humidify and dehumidify
outputs in controlling humidity. It can also be field configured to be non-programmable. Humidify outputs connect directly to 24-v
humidifiers. Dehumidify outputs connect directly to variable-speed furnaces or fan coils that have dehumidification capabilities. To
achieve full benefits, this model requires use of the Outdoor Air Temperature Sensor accessory, which is included with the Thermidistat Control.
—7—
OPERATIONAL INFORMATION
FIVE-MINUTE COMPRESSOR TIMEGUARD
This timer prevents the compressor from starting unless it has been off for at least 5 minutes. It can be defeated for 1 cycle by simultaneously pressing the F AN mode button and INCREASE TEMPERATURE (UP) button.
FIFTEEN-MINUTE CYCLE TIMER
This timer prevents the start of a heating or cooling cycle until at least 15 minutes after the last start of the same cycle. Its function is to
assure that equipment is not cycled more than 4 times per hr. This timer is defeated for 1 cycle when the desired temper ature is man ually
changed. It can also be defeated for 1 cycle by simultaneously pressing the FAN button and the INCREASE TEMPERATURE button.
FIFTEEN-MINUTE STAGING TIMER
In multistage heating or cooling, this timer prevents any higher stage from turning on until preceding stage has been on for 15 minutes.
This timer is defeated if temperature error is greater than 5°F (usually due to a large change in desired temperature).
MINIMUM ON TIME
In normal operation, when a stage turns on, it will not turn off for a minimum of 3 minutes (2 minutes on Builder’s model).
HEAT/COOL SET POINTS (DESIRED TEMPERATURE)
A minimum difference of 2° is enf orced betw een heating and cooling desired temper atures . This is done by allowing one setting to “push”
the other, to maintain this difference. (Thermidistat Control is adjustable.) Builder’ s thermostats are controlled b y a single set point.
EQUIPMENT ON INDICATORS (NON-PROGRAMMABLE MODELS)
When cooling equipment is ON, a COOL ON icon is displayed above the room temperature display. When heating equipment is ON, a
HEAT ON icon is displayed above the room temperature displa y.
EQUIPMENT ON INDICATORS (THERMIDISTAT CONTROL)
When cooling equipment is ON, a COOL icon preceded by a small triangle is displayed below the cool set point. While cooling equipment turn on is delayed by a staging or cycle timer, the triangle and the word COOL will flash. The same is true for the HEAT icon and
its preceding triangle located under the heat set point. The 2 triangles are also used to indicate the state of the humidify and dehumidify
outputs. See next section.
HUMIDIFY/DEHUMIDIFY OUTPUT ON INDICATORS (THERMIDISTAT CONTROL)
Within humidity select screen (selected by Humidity button and indicated by “hu” or “dhu” on clock display), the triangle under humidity
set point will be on while humidify output is on. The tr iangle under dehumidify set point will be on while dehumidify output is active
(turned off, because this output is reverse logic).
AUTO CHANGEOVER
When auto changeover mode is selected, a change from heat to cool (or vice versa) will not occur until an opposite mode demand has
existed for 20 minutes. If set point is changed, the 20 minute requirement is deleted. Auto changeover mode can be disabled. Builder’s
thermostats are manual changeover .
EMERGENCY HEAT MODE
When thermostat is controlling as a heat pump and emergency heat is selected, all Y signals are loc k ed out, and W becomes energized
upon a call for heat.
SMART RECOVERY (PROGRAMMABLE MODELS)
With Smart Recovery selected, transition out of setback begins a fixed time period before selected recovery time and gradually adjusts
room temperature so that the desired temperature will be achiev ed at selected recovery time.
ROOM TEMPERATURE OFFSET (ALL MODELS)
Room temperature may be deliberately offset by up to 5°F in either direction.
MAXIMUM ON/OFF DEADBAND
Maximum sensed temperature difference between ON and OFF is 0.8°F for Builder’s thermostats and 0.6°F for all other models.